Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Wide bandgap semiconductor materials and devices

The technological and societal impacts of electronic devices based on Ge, Si, and compound semiconductors like GaAs have been profound, fueling the decades long quest in identifying ever-larger bandgap semiconductors to untap new applications and possibilities. Specifically, an increase in the bandgap leads to shorter wavelength emission and an increased breakdown electric field, which has direct consequences for solid-state lighting like light-emitting diodes (LEDs) and laser diodes (LDs) from the visible (blue-green, blue, and violet) and beyond (UV and deep-UV) spectral range and for radically improved power devices supported by a higher intrinsic breakdown strength. Wide bandgap (WBG) semiconductors represent the frontier of materials that satisfy these criteria and include group IV, III–V, and II–VI material families like SiC (3.2 eV), GaN (3.4 eV), and ZnO (3.4 eV), respectively. With even larger bandgaps exceeding 4 eV, ultrawide bandgap (UWBG) semiconductors include diamond, III-nitrides incorporating Al and B (e.g., AlN, BN, and AlGaN), and sesquioxides like Ga 2 O 3 and (Al,Ga) 2 O 3 . These materials span widely varying stages of technological maturity, with SiC and GaN platforms among the most mature with commercially available devices in RF and high-power electronics, while other platforms such as Ga 2 O 3 rapidly advancing and poised to enable new UV and deep-UV optoelectronic devices. This Special Topic on Wide Bandgap Semiconductor Materials and Devices covers broad research subtopics on WBG and UWBG materials that span bulk crystals, epitaxy and substrate technologies, fundamental defect science, and doping, as well as electronic and optoelectronic device fabrication and characterization. Here, we highlight works from the collection, which we categorize by material platform of SiC, III-nitrides, and Ga 2 O 3 and related alloys.

36 MATERIALS SCIENCE↗

Dependence of alpha-particle-driven Alfvén eigenmode linear stability on device magnetic field strength and consequences for next-generation tokamaks

Recently-proposed tokamak concepts use magnetic fields up to 12 T, far higher than in conventional devices, to reduce size and cost. Theoretical and computational study of trends in plasma behavior with increasing field strength is critical to such proposed devices. This paper considers trends in Alfvén eigenmode (AE) stability. Energetic particles, including alphas from deuterium–tritium fusion, can destabilize AEs, possibly causing loss of alpha heat and damage to the device. AEs are sensitive to device magnetic field via the field dependence of resonances, alpha particle beta, and alpha orbit width. We describe the origin and effect of these dependences analytically and by using recently-developed numerical techniques (Rodrigues et al 2015 Nucl. Fusion 55 083003). The work suggests high-field machines where fusion-born alphas are sub-Alfvénic or nearly sub-Alfvénic may partially cut off AE resonances, reducing growth rates of AEs and the energy of alphas interacting with them. High-field burning plasma regimes have non-negligible alpha particle beta and AE drive, but faster slowing down time, provided by high electron density, and higher field strength reduces this drive relative to low-field machines with similar power densities. The toroidal mode number of the most unstable modes will tend to be higher in high magnetic field devices. Finally, the work suggests that high magnetic field devices have unique, and potentially advantageous, AE instability properties at both low and high densities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intercomparison of Commercially Available Active Radon Measurement Devices in a Discovered Radon Chamber

An unventilated 70 m 3 underground space, with 2.1 m high ceilings and an inner set of concrete walls to damp vibrations, was discovered to have relatively stable radon levels of ~1,080 Bq m -3 over a 1-y period. The addition of radium sources was not required to achieve high and somewhat variable radon levels, as these arise naturally in the space. Several active radon monitoring devices designed for homeowners, radon screeners, radon mitigation professionals, and researchers were tested in the space. These devices were variable in both cost and intended user sophistication. Data were collected at specific time intervals that varied for each device. A cellphone was deployed with an available camera application to periodically capture photographs of the displays of devices not enabled for automatic temporal recording. Attempts were made to alter the radon concentration using fans, radium-laden objects, and radon impermeable sheets. Statistical methods were employed to compare the device's performance under the minor radon transients produced by the addition of 226 Ra sources during the test period. The evaluation of the overall accuracy, noise, and response to transients revealed highly affordable devices that may be useful for future research applications.While unsuitable for precise calibrations at stable radon levels, the space was determined to be adequate as a radon chamber for general research purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrostatic modulation of the lateral carrier density profile in field effect devices with nonlinear dielectrics

The properties of two-dimensional (2D) electronic systems are often effectively controlled using electrostatic gating. The geometry of such field effect devices influences the effectiveness of the gate and the carrier density profile in the 2D device. Here, in this work, we analyze the gate-induced spatial variations in the lateral carrier density in patterned LaAlO 3 /SrTiO 3 devices. We model the electrostatics of the 2D interface using the Thomas-Fermi approximation and compute the gate-induced charge distribution at the interface. We show that the electric field lines generated by the gate are focused at the edges of the device, causing an increased depletion near its edges. This effect is accentuated in LaAlO 3 /SrTiO 3 due to the large, nonlinear dielectric constant of the substrate, and the large distance between the gate electrode and the interface. We experimentally demonstrate one consequence of this effect by directly imaging current distributions in gated heterostructures, finding that insulating regions nucleate at the edges of the device due to the gate. Our results suggest that device geometry and choice of dielectric materials control the charge distribution in 2D systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Device Feasibility Analysis of Multi-level FeFETs for Neuromorphic Computing

As an emerging non-volatile memory device technology, Ferroelectric Field-Effect Transistors (FeFETs) can enable low-power, adaptive intelligent system design. However, device dimension and operating voltage dependent reliability issues of scaled FeFETs can ultimately lead to degraded performance in solving machine learning tasks. In this article, detailed experimental characterization of FeFET devices of different dimensions have been carried out to explicitly evaluate the non-ideal behavior in device conductance programming properties like number of programming states, cycle-to-cycle (C2C) variations, device-to-device (D2D) variations, and state retention. A hardware-aware software simulation approach has been adopted to capture the adversarial effects of the non-idealities on recognition accuracy through algorithm-level performance assessment by including them in NeuroSim, a popular neural network hardware simulator, to execute a neural network model considering all other hardware constraints. With the added non-idealities, significant accuracy degradation has been observed compared to the ideal scenarios where D2D variations play the most critical role. Thereafter, feasibility of a variation-aware training method has been evaluated to tackle the accuracy drop.

42 ENGINEERING↗

Avoiding Divergent Oscillation of Cascode GaN Device under High Current Turn-off Condition

Cascode structure is widely used for high voltage normally-on GaN devices. However, the capacitance mismatch between the high voltage GaN device and the low voltage normally- off Si MOSFET may induce several undesired features, such as Si MOSFET reaches avalanche during turn-off, and high voltage GaN device loses ZVS turn-on condition internally during soft-switching turn-on process in every switching cycle. This paper presents another issue associated with the capacitance mismatch in the cascode GaN devices. Divergent oscillation could occur at high current turn-off condition, and eventually destroy the device. The intrinsic reason of this phenomenon is analyzed in detail in this paper. A simple solution is proposed by adding an additional capacitor whose position is critical and should be optimized. Experimental results validate the theoretical analysis, and show that the proposed method improves device performance significantly under high current turn-off condition.

Du, Weijing↗

Thermal Stress Reduction in Power Switching Devices Using Distributed Loss PWM Concept for Current Source Inverters

A new modulation scheme is proposed for current source inverters (CSIs) that reduces the variation and peak junction temperature in the CSIs' power devices. The distributed loss pulse-width modulation (DLM) concept is introduced and applied to traditional space vector modulation methods to develop modified modulation schemes that reduce the thermal stress on power devices. The device junction temperatures resulting from conventional and DLM schemes are compared. Simulation and experimental results confirm that the proposed DLM concept reduces thermal stress on the devices while maintaining the same high output current waveform quality compared to traditional CSI modulation schemes. The CSI power device lifetime (i.e., the number of cycles to failure) are estimated using the simulation and experimental results. The proposed DLM significantly increases the device lifetime (by 5 to 6 times) by reducing the junction temperature variation compared to the conventional modulations.

42 ENGINEERING↗

Quantifying Dynamic On-State Resistance of GaN HEMTs for Power Converter Design via a Survey of Low and High Voltage Devices

Designing and optimizing high switching frequency, ultra-efficient converters requires detailed knowledge of the behavior and parasitic parameters for both active and passive components. Recently, wide bandgap transistors have enabled simultaneous increases in both switching frequency and efficiency due to higher maximum operating junction temperature limits, lower dc on-state resistances, and reduced parasitic inductances and capacitances. Yet, the early acceptance of gallium-nitride (GaN) switches was plagued by detrimental dynamic on-state resistance effects. This complex phenomenon for GaN devices is characterized by deviations in on-state resistance from dc operating characteristics based on design choices such as the magnitude and duration of both voltage and current stress, switching mode, and junction temperature. While device manufacturers have made improvements compared to early generation devices, experimental evidence from a survey of commercial GaN transistors highlight measurable change in on-state resistance still exists due to variations in voltage stress during hard-switching operation. After sharing insights for obtaining low noise measurements, an analysis method along with two metrics are proposed to characterize dynamic on-state resistance measurements for power electronics designers. Furthermore, quantifying the performance of GaN devices with standardized metrics facilitates a fair comparison between different GaN device technologies during converter development, enables manufacturing qualification for GaN switches, and provides a benchmark to catalyze improvement for the next generation of GaN device development.

14 SOLAR ENERGY↗

Intelligent Gate Drive for Fast Switching and Crosstalk Suppression of SiC Devices

This study presents an intelligent gate drive for silicon carbide (SiC) devices to fully utilize their potential of high switching-speed capability in a phase-leg configuration. Based on the SiC device's intrinsic properties, a gate assist circuit consisting of two auxiliary transistors with two diodes is introduced to actively control gate voltages and gate loop impedances of both devices in a phase-leg configuration during different switching transients. Compared to conventional gate drives, the proposed circuit has the capability of accelerating the switching speed of the phase-leg power devices and suppressing the crosstalk to below device limits. Based on Wolfspeed 1200-V SiC MOSFETs, the test results demonstrate the effectiveness of this intelligent gate drive under varying operating conditions. More importantly, the proposed intelligent gate assist circuitry is embedded into a gate drive integrated circuit, offering a simple, compact, and reliable solution for end-users to maximize benefits of SiC devices in actual power electronics applications.

30 DIRECT ENERGY CONVERSION↗

The effect of blood viscosity on shear‐induced hemolysis using a magnetically levitated shearing device

Abstract Introduction Blood contacting medical devices, including rotary blood pumps, can cause shear‐induced blood damage that may lead to adverse effects in patients. Due in part to an inadequate understanding of how cell‐scale fluid mechanics impact red blood cell membrane deformation and damage, there is currently not a uniformly accepted engineering model for predicting blood damage caused by complex flow fields within ventricular assist devices (VADs). Methods We empirically investigated hemolysis in a magnetically levitated axial Couette flow device typical of a rotary VAD. The device is able to accurately control the shear rate and exposure time experienced by blood and to minimize the effects of other uncharacterized stresses. Using this device, we explored the effects of both hematocrit and plasma viscosity on shear‐induced hemolysis to characterize blood damage based on the viscosity‐independent shear rate, rather than on shear stress. Results Over a shear rate range of 20 000 – 80 000 1/s, the Index of Hemolysis (IH) was found to be dependent upon and well‐predicted by the shear rate alone. IH was independent of hematocrit, bulk viscosity, or the suspension media viscosity and less correlated to shear stress (MSE = 0.46–0.75) than to shear rate (MSE = 0.06–0.09). Conclusion This study recommends that future investigations of shear‐induced blood damage report findings with respect to the viscosity‐neutral term of shear rate, in addition to the bulk whole blood viscosity measured at an appropriate shear rate relevant to the flow conditions of the device.

Krisher, James A.↗

Comparative operando XPS studies of quasi-Fermi level splitting and open-circuit voltage in CZTSe/CdS and CIGS/CdS junctions and device structures

This contribution describes operando x-ray photoelectron spectroscopy (opXPS) studies of Cu(In,Ga)Se 2 (CIGS) and Cu 2 ZnSnSe 4 (CZTSe) absorber layers and device structures. X-ray-excited valence-band and core-level spectra were acquired on bare absorber surfaces and after CdS and ZnO:Al depositions in standard absorber/CdS/ZnO/ZnO:Al device stacks. OpXPS data sets were acquired at various x-ray fluxes, with and without white-light illumination. From these measurements, quasi-Fermi level splitting (ΔE F ) values in the absorber/CdS junctions were measured directly as a function of excitation conditions. For both CIGS and CZTSe, results show that ..delta..EF proportional to the full open-circuit voltage (V OC ) of the completed devices is present after the deposition of the CdS layer - i.e., E F = qV OC - demonstrating that the so-called V OC deficit in CZTSe solar cells is also present at this stage of processing. The authors find that photoexcitation due to x-rays or stray visible light during XPS or similar measurements can produce measurable photovoltages in materials, absorber/CdS junctions, and finished devices. In situ current density versus voltage measurements on a typical CIGS device reveal that x-ray-induced photoexcitation associated with typical XPS measurement conditions is equivalent to ~3 x 10 -3 suns, which in this study produced V OC = 440 mV. These findings demonstrate that accounting for photoexcitation conditions during XPS or similar measurements can improve band-offset determinations and produce more reliable values for the junction built-in voltage. The implications of the study findings on the CZTSe V OC deficit and device performance are discussed.

36 MATERIALS SCIENCE↗

Structural breakdown in high power GaN-on-GaN p-n diode devices stressed to failure

The morphology of GaN-on-GaN vertical p-i-n diode devices after reverse-bias electrical stressing to breakdown has been investigated. All failed devices had irreversible structural damage, showing large surface craters that were ∼15–35 μm deep with lengthy surface cracks. Cross-sectional electron micrographs of failed devices showed substantial concentrations of threading dislocations around the cracks and near the crater surfaces. Progressive ion-milling across damaged devices revealed high densities of threading dislocations and the presence of voids beneath the surface cracks; these features were not observed in any unstressed devices. These results should serve as a useful reference for future reliability studies of vertical high-power GaN devices.

Peri, Prudhvi (ORCID:000000022338441X)↗

Dosimetric effects caused by couch tops and immobilization devices: Report of AAPM Task Group 176

The dosimetric impact from devices external to the patient is a complex combination of increased skin dose, reduced tumor dose, and altered dose distribution. Although small monitor unit or dose corrections are routinely made for blocking trays, ion chamber correction factors, e.g., accounting for temperature and pressure, or tissue inhomogeneities, the dose perturbation of the treatment couch top or immobilization devices is often overlooked. These devices also increase skin dose, an effect which is also often ignored or underestimated. These concerns have grown recently due to the increased use of monolithic carbon fiber couch tops which are optimal for imaging for patient position verification but cause attenuation and increased skin dose compared to the “tennis racket” style couch top they often replace. Also, arc delivery techniques have replaced stationary gantry techniques which cause a greater fraction of the dose to be delivered from posterior angles. A host of immobilization devices are available and used to increase patient positioning reproducibility, and these also have attenuation and skin dose implications which are often ignored. This report of Task Group 176 serves to present a survey of published data that illustrates the magnitude of the dosimetric effects of a wide range of devices external to the patient. The report also provides methods for modeling couch tops in treatment planning systems so the physicist can accurately compute the dosimetric effects for indexed patient treatments. Both photon and proton beams are considered. A discussion on avoidance of high density structures during beam planning is also provided. An important aspect of this report are the recommendations the authors make to clinical physicists, treatment planning system vendors, and device vendors on how to make measurements of surface dose and attenuation and how to report these values. For the vendors, an appeal is made to work together to provide accurate couch top models in planning systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-16: A Comparison of Expected Dwell Times and Dose Variations for NAMD Patients Treated with An Episcleral Brachytherapy Device

Purpose: To evaluate the variations in dwell times and doses expected when using an episcleral brachytherapy device for treatment of neovascular agerelated macular degeneration (n-AMD) based on accurate imaging modalities Methods: Data from 40 eyes from 40 subjects with known n- AMD acquired through the Distance of Choroid Study (DOCS) conducted at Moorfields Eye Hospital was used to determine the target depth; the distance from the outer scleral surface of the eye, through the choroid, to the apex of the choroidal neovascularization (CNV). Each subject underwent, in triplicate, enhanced-depth Spectral Domain Optical Coherence Tomography (SD-OCT), Swept Source Optical Coherence Tomography, (SS-OCT) and Ocular Ultrasound (O-US). These data are the most comprehensive and accurate measurements of the dimensions of the CNV and adjacent layers of the eye for this cohort of patients. During treatment of n-AMD, patients receive a dose of 24Gy to the apex at the target depth. Using the percentage depth dose for a Sr-90 episcleral brachytherapy device, dwell times and doses to the apex were computed to determine the expected variations. Results: The mean target depth and the 95% confidence interval (CI) determined by combining O-US with SD-OCT were 1326 (956,1696)µm and with SS-OCT were 1332 (970,1693)µm. The calculated corresponding mean dwell times and 95% (CI) were 334 (223,445)s and 335 (226,445)s for SD-OCT and SS-OCT determined depths, respectively. The corresponding mean apex dose and 95% (CI) were 24 (35.9,18.0)Gy (SD-OCT) and 24 (35.6,18.1)Gy (SS-OCT). Conclusion: For episcleral brachytherapy treatment of n-AMD, using a patient population average target depth for treatment planning is inadequate, resulting in dose variations of a factor of approximately two over the 95% CI and larger variations for a nontrivial segment of the population. Each patient should have individualized imaging studies to determine the target depth for use in the dwell time calculation. Study was sponsored by Salutaris Medical Devices, Ltd., a subsidiary of Salutaris Medical Devices, Inc. Hamilton and Marsteller are founders of Salutaris Medical Devices, Inc. Drew, McGovern and Vitali are minor equity holders in Salutaris Medical Devices, Inc.

60 APPLIED LIFE SCIENCES↗

SU-F-T-526: A Comparative Study On Gating Efficiency of Varian RPM Device and Calypso System

Purpose: In general, the linear accelerator is gated using respiratory signal obtained by way of external sensors to account for the breathing motion during radiotherapy. One of the commonly used gating devices is the Varian RPM device. Calypso system that uses electromagnetic tracking of implanted or surface transponders could also be used for gating. The aim of this study is to compare the gating efficiency of RPM device and the calypso system by phantom studies. Methods: An ArcCheck insert was used as the phantom with a Gafchromic film placed in its holder. The ArcCheck insert was placed on a Motion Sim platform and moved in the longitudinal direction simulating a respiratory motion with a period of 5 seconds and amplitude of ±6mm. The Gafchromic film was exposed to a 2 × 2cm{sup 2} field, i) with the phantom static, ii) phantom moving but ungated iii) gated with gating window of 2mm and 3mm. This was repeated with Calypso system using surface transponders with the same gating window. The Gafchromic films were read with an EPSON 11000 flatbed scanner and analysed with ‘Medphysto’ software. Results: The full width at half maximum (FWHM) as measured with film at the level of the film holder was 1.65cm when the phantom was static. FWHM measured with phantom moving and without gating was 1.16 cm and penumbra was 7 mm (80–20%) on both sides. When the beam was gated with 2 mm gating window the FWHM was 1.8 cm with RPM device and 1.9 cm with Calypso. Similarly, when the beam was gated with 3 mm window, the FWHM was 1.9cm with RPM device and 2cm with Calypso. Conclusion: This work suggests that the gating efficiency of RPM device is better than that of the Calypso with surface transponder, with reference to the latency in gating.

60 APPLIED LIFE SCIENCES↗

MO-A-BRC-00: TG167: Clinical Recommendations for Innovative Brachytherapy Devices and Applicators

Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used to evaluate innovative radiotherapy devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining equivalence of the innovative device to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of an innovative brachytherapy device or application is a critical part in which physicists are actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative products or applications and includes evaluation of 1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, 2) risks and benefits from regulatory and safety perspectives, and 3) resource assessment and preparedness. Further, calibration methods should be traceable to a primary standards dosimetry laboratory such as NIST in the U.S. or to other primary standards dosimetry laboratory located elsewhere. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the ADCLs is encouraged before a source is introduced into widespread routine clinical use. The AAPM and GEC-ESTRO have developed guidelines for the safe and consistent application of brachytherapy using innovative brachytherapy devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. NRC, FDA, Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, European Commission for CE Marking, and institutional review boards and radiation safety committees. Learning Objectives: Understand the necessary dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use. Evaluate risks and benefits from regulatory and safety perspectives. Identify necessary resources and create a plan for clinical introduction of innovative brachytherapy device or applications. Consultant for Theragenics Corp.; R. Nath, Consultant to Theragenics Corp.

60 APPLIED LIFE SCIENCES↗

Pilot Scale Water Gas Shift - Membrane Device for Hydrogen from Coal

The objectives of the project were to build pilot scale hydrogen separation systems for use in a gasification product stream. This device would demonstrate fabrication and manufacturing techniques for producing commercially ready facilities. The design was a 2 lb/day hydrogen device which included composite hydrogen separation membranes, a water gas shift monolith catalyst, and stainless steel structural components. Synkera Technologies was to prepare hydrogen separation membranes with metallic rims, and to adjust the alloy composition in their membranes to a palladium-gold composition which is sulfur resistant. Chart was to confirm their brazing technology for bonding the metallic rims of the composite membranes to their structural components and design and build the 2 lbs/day device incorporating membranes and catalysts. WRI prepared the catalysts and completed the testing of the membranes and devices on coal derived syngas. The reactor incorporated eighteen 2'' by 7'' composite palladium alloy membranes. These membranes were assembled with three stacks of three paired membranes. Initial vacuum testing and visual inspection indicated that some membranes were cracked, either in transportation or in testing. During replacement of the failed membranes, while pulling a vacuum on the back side of the membranes, folds were formed in the flexible composite membranes. In some instances these folds led to cracks, primarily at the interface between the alumina and the aluminum rim. The design of the 2 lb/day device was compromised by the lack of any membrane isolation. A leak in any membrane failed the entire device. A large number of tests were undertaken to bring the full 2 lb per day hydrogen capacity on line, but no single test lasted more than 48 hours. Subsequent tests to replace the mechanical seals with brazing have been promising, but the technology remains promising but not proven.

01 COAL, LIGNITE, AND PEAT↗

High Temperature, High Pressure Devices for Zonal Isolation in Geothermal Wells

The U.S. Department of Energy is leading the development of alternative energy sources that will ensure the long-term energy independence of our nation. One key renewable resource being advanced is geothermal energy which offers an environmentally benign, reliable source of energy for the nation. To utilize this resource, water will be introduced into wells 3 to 10 km deep to create a geothermal reservoir. This approach is known as an Enhanced Geothermal System (EGS). The high temperatures and pressures at these depths have become a limiting factor in the development of this energy source. For example, reliable zonal isolation for high-temperature applications at high differential pressures is needed to conduct mini-fracs and other stress state diagnostics. Zonal isolation is essential for many EGS reservoir development activities. To date, the capability has not been sufficiently demonstrated to isolate sections of the wellbore to: 1) enable stimulation; and 2) seal off unwanted flow regions in unknown EGS completion schemes and high-temperature (>200°C) environments. In addition, packers and other zonal isolation tools are required to eliminate fluid loss, to help identify and mitigate short circuiting of flow from injectors to producers, and to target individual fractures or fracture networks for testing and validating reservoir models. General-purpose open-hole packers do not exist for geothermal environments, with the primary barrier being the poor stability of elastomeric seals at high temperature above 175°C. Experimental packer systems have been developed for geothermal environments but they currently only operate at low pressure, they are not retrievable, and they are not commercially available. The development of the high-temperature, high-pressure (HTHP) zonal isolation device would provide the geothermal community with the capability to conduct mini-fracs, eliminate fluid loss, to help identify and mitigate short circuiting of flow from injectors to producers, and to target individual fractures or fracture networks for testing and validating reservoir models. The goal of this program, therefore, was to develop and demonstrate reliable high-temperature high-pressure zonal isolation devices that are compatible with the high-temperature downhole environment anticipated for Enhanced Geothermal Systems. Over the course of this 3 year program, CTD designed and demonstrated a high temperature high pressure zonal isolation device. CTD has utilized its expertise in high-temperature materials, shape memory composites and foams, and deployment mechanisms for spacecraft and oil tools to develop a new class of HTHP zonal isolation devices for use in EGS. Specifically, the objective was to demonstrate the ability to isolate sections of an EGS wellbore to: 1) enable stimulation; and 2) seal off unwanted flow regions in unknown EGS completion schemes and high-temperature (>200°C) environments at temperatures upwards of 300°C. A concept for a high-temperature, high-pressure zonal isolation device was designed for use in creating circulation paths in environments where temperatures are in excess of 300°C and differential pressures of up to 10,000 psi are required to stimulate solid granite. This new zonal isolation device distributes the high-pressure differential through a significant length of high temperature, shape memory polymer composite material. The development of differential pressure is initiated by a thermally triggered actuation of a ‘structural seal’ that fills the cross section of the bore with the shape memory material. After this preliminary seal is made, differential pressure begins to build through the material as the seal forces the flow to pass through pores in the shape memory material. The shape memory material is compressed into place to react the force of the internal

58 GEOSCIENCES↗