Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coupled system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Magnetically tuned metal-insulator transition in LaAlO 3 /SrTiO 3 nanowire arrays

A wide family of two-dimensional (2D) systems, including stripe-phase superconductors, sliding Luttinger liquids, and anisotropic 2D materials, can be modeled by an array of coupled one-dimensional (1D) electron channels or nanowire arrays. Here we report experiments in arrays of conducting nanowires with gate and field tunable interwire coupling, that are programmed at the LaAlO 3 /SrTiO 3 interface. We find a magnetically tuned metal-to-insulator transition in which the transverse resistance of the nanowire array increases by up to four orders of magnitude, which can be further tuned with a gate voltage. To explain this behavior, we develop a minimal model of a coupled two-wire system where a Wenzel-Kramers-Brillouin-based approach is used to estimate the transverse tunneling conductance. We demonstrate the existence of distinct conductance features and highlight the crucial role played by the field dependence of the interwire potential barrier on transport properties. Since our model makes minimal assumptions, we expect our predictions to hold for a wide class of coupled 1D systems. The nanowire arrays can serve as model systems to understand the origin of exotic behavior in correlated materials via analog quantum simulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spin pumping driven by magnon-polaritons in a ferromagnet–coplanar superconducting resonator hybrid system

We demonstrate spin pumping driven by a strongly coupled magnon-photon system using a ferromagnet-coplanar superconducting resonator hybrid system at 1.4 K. Electrical readout via the inverse spin-Hall effect reveals characteristic coupling features, including mode splitting and linewidth broadening, demonstrating the electrical detection of strongly coupled microwave photons and magnons. The microwave magnon-photon coupling strength obtained by combined spin pumping and inverse spin-Hall effect measurements is compared to microwave transmission experiments. Here, microwave power-dependent measurements reveal a decrease in the coupling strength with increasing microwave power alongside the onset of nonlinearities of the superconducting resonator above a critical microwave power threshold.

Wagle, Dinesh [University of Delaware, Newark, DE ↗

Performance and Accuracy Implications of Parallel Split Physics-Dynamics Coupling in the Energy Exascale Earth System Atmosphere Model

Simultaneous calculation of atmospheric processes is faster than calculating processes one at a time. This type of parallelism is beneficial or perhaps even necessary to provide good performance on modern supercomputers, which achieve faster performance through increased processor count rather than improved clock speed. The scalability of the Energy Exascale Earth System Model (E3SM) Atmosphere Model (EAM) is limited by the fluid dynamics which scales up to the number of mesh cells in the global mesh. In contrast, the suite of physics parameterizations in EAM is scalable up to the total number of physics columns, which is an order of magnitude greater than the number of mesh cells. A proposed solution to unlocking the greater potential performance from the physics suite is to solve the physics and dynamics in parallel. This work represents a first attempt at parallel splitting of the grid-scale fluid dynamics model and the subgrid-scale physics parameterizations in a global atmosphere model. We will demonstrate that switching to parallel physics-dynamics coupling extends the scalability of the EAM to up to 3 times the previous peak scalability limit and is up to 20% faster than the sequentially split coupling at the highest core counts and the same time step. Decadal simulations of both coupling approaches show very little impact to the model climate. This improved performance does not come without drawbacks, however. Parallel splitting requires a shorter time step and other modifications which largely offset performance gains. A mass fixer is required for conservation. Techniques for mitigating these issues are also discussed.

97 MATHEMATICS AND COMPUTING↗

Contributions of Solar + Storage to Future Power Needs

The costs of solar photovoltaics (PV) have been dropping in recent years, leading to increasing installations of solar PV systems and growing interest in how the technology will impact the electric grid. Additionally, as battery costs decline, there is increasing interest in understanding the benefits and limitations of battery storage for the grid as well as potential co-benefits of coupling battery storage and photovoltaics. This paper presents recent methodological developments to more accurately represent the value and limitations of coupled PV and battery systems in capacity expansion models. These are demonstrated using the Resource Planning Model (RPM), which co-optimizes capacity investments, transmission investments, and reduced-order dispatch through 2045. We simulate the evolution of the generation and transmission system in the Western Interconnection both with and without a coupled PV and battery technology option under two core scenarios - a baseline scenario and a high renewable penetration scenario - coupled with sensitivities assuming low and mid PV and battery cost projections. We analyze the degree to which a variety of configurations of coupled PV + Battery systems are able to meet future electricity needs, under which system conditions this coupled technology becomes beneficial to the electric grid and identify the displaced technologies when coupled solar and storage is introduced into the model. We find that capturing the benefits of co-locating these systems becomes increasingly important as the penetration of solar PV rises, and that in particular it is important to accurately capture the ability of these technologies to shift energy, provide firm capacity, and reduce expected curtailment.

14 SOLAR ENERGY↗

Impacts of hybridization and forecast errors on the probabilistic capacity credit of batteries

Battery storage is increasingly identified as being among the least-cost mix of technologies in the evolving U.S. electricity mix. This study explores the marginal capacity credit of batteries using a probabilistic, reliability-based, effective firm capacity method, which we apply for multiple battery power ratings, durations, coupling types, deployment locations, and dispatch profiles within a test system that is based on the Texas Interconnection in the year 2024. We find that the capacity credits for all battery durations depend on their ability to predict the timing of reliability events. Even 1-2 h forecast errors - resulting in early or delayed battery discharging relative to the onset of a reliability event - lead pronounced capacity credit reductions, especially for 4-h duration batteries. Coupling batteries with solar mitigates the uncertainty associated with a shorter-duration battery's availability during reliability events, primarily due to the relatively high solar capacity credit in our test system. Coupled (or hybrid) system designs with oversized solar arrays, the ability to charge the coupled battery with grid energy, and larger batteries lead to the greatest capacity credit benefits of hybridization. We do not see evidence that the hybrid capacity credit exceeds the sum of the separate battery and solar capacity credits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On-Chip Cavity Electroacoustics Using Lithium Niobate Phononic Crystal Resonators

Mechanical systems are pivotal in quantum technologies because of their long coherent time and versatile coupling to qubit systems. So far, the coherent and dynamic control of gigahertz-frequency mechanical modes mostly relies on optomechanical coupling and piezoelectric coupling to superconducting qubits. Here, we demonstrate on-chip cavity electroacoustic dynamics using our microwave-frequency electrically modulated phononic crystal resonators on lithium niobate. Leveraging the high dispersion of phononic crystal, our acoustic modes space unevenly in the frequency spectrum, emulating atomic energy levels. Atomiclike transitions between different acoustic modes are selectively achieved by applying electrical fields to modulate acoustic modes via the nonlinear piezoelectricity of lithium niobate. Among two modes, we demonstrate Autler-Townes splitting, ac Stark shift, and Rabi oscillation with a maximum cooperativity of 4.18. Extending to three modes, we achieve nonreciprocal frequency conversions with an isolation up to 20 dB. Nonreciprocity can be tuned by the time delay between the two modulating pulses. Finally, our cavity electroacoustic platform could find broad applications in sensing, microwave signal processing, acoustic computing, and quantum acoustics.

Rabi model↗

Resonant inelastic x-ray scattering investigation of Hund's and spin-orbit coupling in 5 d 2 double perovskites

𝐵 site ordered 5⁢𝑑 2 double perovskites (𝐴 2 ⁢𝐵⁢𝐵′⁢O 6 , 𝐵′ = 5⁢𝑑 2 ) display a remarkable range of physical properties upon variation of the chosen 𝐵 and 𝐵′ site ions. This sensitivity to chemical substitution reflects the delicate balance and profound impact of strong electronic correlation and spin-orbit coupling in such systems. Here, we present rhenium 𝐿 2 and 𝐿 3 resonant inelastic x-ray scattering (RIXS) measurements of two such physically dissimilar materials, Mott-insultating Ba 2⁢ Y⁢Re⁢O 6 and semiconducting Sr 2⁢ Cr⁢Re⁢O 6 . Despite these differences, our RIXS results reveal similar energy scales of Hund's (𝐽 𝐻 ) and spin-orbit coupling (𝜁) in the two materials, with both systems firmly in the intermediate Hund's coupling regime where 𝐽 𝐻 /𝜁∼1. However, there are clear differences in their RIXS spectra. The conductive character of Sr 2⁢ Cr⁢Re⁢O 6 broadens and obfuscates the atomic transitions within an electron-hole continuum, while the insulating character of Ba 2 ⁢Y⁢Re⁢O 6 results in sharp atomic excitations. This contrast in their RIXS spectra despite their similar energy scales reflects a difference in the itinerancy-promoting hopping integral and illustrates the impact of the local crystal environment in double perovskites. Finally, 𝐿 2 and 𝐿 3 edge analyses of the atomic excitations in Ba 2 ⁢Y⁢Re⁢O 6 reveal that the ordering of the low lying excited states is inverted compared to previous reports, such that the appropriate energy scales of Hund's and spin-orbit coupling are significantly modified. We present exact diagonalization calculations of the RIXS spectra at both edges which show good agreement with our results for new energy scales of 𝜁 = 0.290⁢(5)⁢eV and 𝐽 𝐻 = 0.38⁢(2)⁢eV [𝐽 𝐻 /𝜁 = 1.30⁢(5)].

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Are coupled renewable-battery power plants more valuable than independently sited installations?

Coupled renewable-battery powerplants differ from the traditional concept of independent siting of electricity resources within transmission networks. Prior research on the value proposition and cost savings from coupling did not consider the geographic constraint of co-location. This paper fills the gap by assessing how pricing volatility differences between nodes within electricity markets impact the system value of coupled renewable-battery projects as compared to independent VRE and battery installations. We use wholesale power market prices from 2012–2019 across the seven main U.S. independent system operators (ISOs) with a linear optimization program to compare the electricity market value of coupled projects to the value of the same underlying sub-components, deployed separately. We find that additional value from adding a 4-hour battery sized to 50% of renewable-plant nameplate capacity is $\$$10/MWh across ISOs on average. The highest boost occurs in California ($\$$15/MWh), where the value of adding storage to solar rises over time in tandem with increased solar penetration in the region. If renewables and batteries are deployed independently, we estimate that $\$$12.5/MWh of additional value could be achieved because of more flexibility on battery siting and operation. The $\$$12.5/MWh coupling penalty is reduced to $\$$1.6/MWh when considering alternative approaches to integrating battery storage. This result implies that renewable-battery power plants will play an increasing role in electricity systems if they can be built for $\$$2–$\$$13/MWh less than independent projects of comparable size. However, the wide regional variation in coupling penalties, along with the importance of conditions captured in our sensitivity cases, suggests the tradeoff between coupling penalties and savings will vary by situation. Therefore, roles exist for independent and coupled projects from a system optimization perspective.

14 SOLAR ENERGY↗

Keep it short: Exploring the impacts of configuration choices on the recent economics of solar-plus-battery and wind-plus-battery hybrid energy plants

Coupled renewable-battery powerplants differ from the traditional concept of independent siting of electricity resources within transmission networks. Prior research on the value proposition and cost savings from coupling did not consider the geographic constraint of co-location. This paper fills the gap by assessing how pricing volatility differences between nodes within electricity markets impact the system value of coupled renewable-battery projects as compared to independent VRE and battery installations. We use wholesale power market prices from 2012–2019 across the seven main U.S. independent system operators (ISOs) with a linear optimization program to compare the electricity market value of coupled projects to the value of the same underlying sub-components, deployed separately. We find that additional value from adding a 4-hour battery sized to 50% of renewable-plant nameplate capacity is $\$10$/MWh across ISOs on average. The highest boost occurs in California ($\$15$/MWh), where the value of adding storage to solar rises over time in tandem with increased solar penetration in the region. If renewables and batteries are deployed independently, we estimate that $\$12.5$/MWh of additional value could be achieved because of more flexibility on battery siting and operation. The $\$12.5$/MWh coupling penalty is reduced to $\$1.6$/MWh when considering alternative approaches to integrating battery storage. This result implies that renewable-battery power plants will play an increasing role in electricity systems if they can be built for $\$2$–$\$13$/MWh less than independent projects of comparable size. However, the wide regional variation in coupling penalties, along with the importance of conditions captured in our sensitivity cases, suggests the tradeoff between coupling penalties and savings will vary by situation. Therefore, roles exist for independent and coupled projects from a system optimization perspective.

14 SOLAR ENERGY↗

Assessment of MQXF Quench Heater Insulation Strength and Test of Modified Design

The HL-LHC interaction region magnet triplets (Q1,Q2, and Q3) will be composed of superconducting Nb 3 Sn quadrupoles. The MQXF quadrupole protection system is based on CLIQ (Coupling-Loss Induced Quench system) and outer layer quench heaters. Furthermore, this paper reports a summary of quench heaters to coil high voltage tests performed on MQXF short and long coils in air after fabrication, and in air and He gas after magnet training. Breakdown voltage values demonstrate good margin with respect to the Electrical design criteria for the HL-LHC inner triplet mag-nets. A modification in the quench heater installation-with an extra layer of fiber glass between the coil and the quench heater trace-has been proposed and tested in a mirror magnet to further increase electrical margins. Results demonstrated improvements of high voltage margin at the expense of a clear increase of hot spot temperature.The baseline heater to coil insulation was assessed to be able to guarantee safe operation for the Nb 3 Sn quadrupole magnets for the interaction regions of HL-LHC.

43 PARTICLE ACCELERATORS↗

DECOVALEX-2019: An international collaboration for advancing the understanding and modeling of coupled thermo-hydro-mechanical-chemical (THMC) processes in geological systems

The DECOVALEX Project is an international research collaboration for advancing the understanding and modeling of coupled thermo-hydro-mechanical-chemical (THMC) processes in geological systems. DECOVALEX stands for “DEvelopment of COupled Models and VALidation against EXperiments”. The creation of this international initiative, now running for almost 30 years, was motivated by the recognition that prediction of these coupled effects is an essential part of the performance and safety assessment of geologic disposal systems for radioactive waste and spent nuclear fuel, and also for a range of other sub-surface engineering activities. DECOVALEX emphasizes joint analysis and comparative modeling of state-of-the-art field and laboratory experiments, across a range of host rock options and repository designs. Participating research teams are from radioactive waste management organizations, national research institutes, regulatory agencies, universities, and consulting groups, providing a wide range of perspectives and solutions to these complex problems. The most recent phase of the DECOVALEX Project, here referred to as DECOVALEX-2019, started in 2016 and ended in 2019. Modeling teams from 13 international partner organizations participated in the comparative evaluation of seven modeling tasks involving complex field and/or laboratory experiments. Furthermore, this Virtual Special Issue on DECOVALEX-2019 provides an in-depth overview of these collaborative research efforts and how these have advanced the state-of-the-art of understanding and modeling coupled THMC processes.

58 GEOSCIENCES↗

Robust multi‐loop control of a floating wind turbine

Abstract A principal challenge facing the control of floating offshore wind turbines (FOWTs) is the problem of instability, or “negative damping,” when using blade pitch feedback to control generator speed. This closed‐loop instability can be attributed to non‐minimum phase zeros in the transfer function from blade pitch to generator speed. Standard approaches to improving stability and performance include robust tuning of control gains and introducing multiple feedback loops to respond to platform motion. Combining these approaches is nontrivial because multiple control loops complicate the impact of coupling in the system dynamics. The single‐loop approach to analyzing stability robustness neglects inter‐loop coupling, while a simplistic multi‐loop approach is highly sensitive to dimensional scaling and overestimates the robustness of the single‐loop controller. This work proposes a sensitivity representation that separates some of the natural FOWT dynamic coupling into a parallel feedback loop in the sensitivity function loop to address both of these concerns. The modified robustness measure is used with a simplified linear FOWT model to optimize scheduled multi‐loop control parameters in an automated tuning procedure. This controller is implemented for the 10‐MW Ultraflexible Smart FLoating Offshore Wind Turbine (USFLOWT) and compared against conventional single‐ and multi‐loop controllers tuned using frequency‐domain analysis and high‐fidelity OpenFAST simulations. The multi‐loop robust controller shows the highest overall performance in generator speed regulation and tower load reduction, though consideration of power quality, actuator usage, and other structural loading leads to additional trade‐offs.

Stockhouse, David↗