Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Next-to-leading order QCD corrections to the single top quark production via model-independent tqg flavor-changing neutral-current couplings at hadron colliders

We present the calculations of the complete next-to-leading order (NLO) QCD effects on the single top productions induced by model-independent tqg flavor-changing neutral-current couplings at hadron colliders. Our results show that, for the tcg coupling, the NLO QCD corrections can enhance the total cross sections by about 60% and 30%, and for the tug coupling by about 50% and 20% at the Tevatron and LHC, respectively, which means that the NLO corrections can increase the experimental sensitivity to the flavor-changing neutral-current couplings by about 10%-30%. Moreover, the NLO corrections reduce the dependence of the total cross sections on the renormalization or factorization scale significantly, which lead to increased confidence on the theoretical predictions. Besides, we also evaluate the NLO corrections to several important kinematic distributions, and find that for most of them the NLO corrections are almost the same and do not change the shape of the distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Potentially large one-loop corrections to WIMP annihilation

We compute one-loop corrections to the annihilation of nonrelativistic particles {chi} due to the exchange of a (gauge or Higgs) boson {phi} with mass {mu} in the initial state. In the limit m{sub {chi}>}>{mu} this leads to the 'Sommerfeld enhancement' of the annihilation cross section. However, here we are interested in the case {mu} < or approx. m{sub {chi},} where the one-loop corrections are well behaved, but can still be sizable. We find simple and accurate expressions for annihilation from both S- and P-wave initial states; they differ from each other if {mu}{ne}0. In order to apply our results to the calculation of the relic density of weakly interacting massive particles (WIMPs), we describe how to compute the thermal average of the corrected cross sections. We apply this formalism to scalar and Dirac fermion singlet WIMPs, and show that the corrections are always very small in the former case, but can be very large in the latter. Moreover, in the context of the minimal supersymmetric standard model, these corrections can decrease the relic density of neutralinos by more than 1%, if the lightest neutralino is a strongly mixed state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

One-loop corrections to the Nielsen-Olesen vortex: Finite length

We consider the one-loop quantum corrections to the Nielsen-Olesen flux tube of finite length L, by imposing periodic boundary conditions. The calculations are based on a recent evaluation of these quantum corrections to the string tension of an infinite vortex. The finite length corrections are finite from the outset. If the computation is restricted to the zero modes we obtain the standard Luescher term {pi}/3L for a closed string. The inclusion of the other fluctuation modes of Higgs and gauge fields, using the numerically computed trace of the Euclidian Green's function, leads to corrections that decrease exponentially with L. We present numerical results for these corrections, and discuss their possible relevance and the limitations of the approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relativistic corrections to the exclusive decays of C-even bottomonia into S-wave charmonium pairs

Within the nonrelativistic quantum chromodynamics (NRQCD) factorization formalism, we compute the relativistic corrections to the exclusive decays of bottomonia with even charge conjugation parity into S-wave charmonium pairs at leading order in the strong coupling constant. Relativistic corrections are resummed for a class of color-singlet contributions to all orders in the charm-quark velocity v{sub c} in the charmonium rest frame. Almost every process that we consider in this work has negative relativistic corrections ranging from -20 to -35%. Among the various processes, the relativistic corrections of the next-to-leading order in v{sub c} to the decay rate for {chi}{sub b2}{yields}{eta}{sub c}(mS)+{eta}{sub c}(nS) with m, n=1 or 2 are very large. In every case, the resummation of the relativistic corrections enhances the rate in comparison with the next-to-leading-order results. We compare our results with available predictions based on the NRQCD factorization formalism. The NRQCD predictions are significantly smaller than those based on the light-cone formalism by 1 or 2 orders of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Specimen-displacement correction for powder X-ray diffraction in Debye–Scherrer geometry with a flat area detector

The effect of small changes in the specimen-to-detector distance on the unit-cell parameters is examined for synchrotron powder diffraction in Debye–Scherrer (transmission) geometry with a flat area detector. An analytical correction equation is proposed to fix the shift in 2θ values due to specimen capillary displacement. This equation does not require the use of an internal reference material, is applied during the Rietveld refinement step, and is analogous to the specimen-displacement correction equations for Bragg–Brentano and curved-detector Debye–Scherrer geometry experiments, but has a different functional form. The 2θ correction equation is compared with another specimen-displacement correction based on the use of an internal reference material in which new integration and calibration parameters of area-detector images are determined. Example data sets showing the effect of a 3.3 mm specimen displacement on the unit-cell parameters for 25°C CeO 2 , including both types of displacement correction, are described. These experiments were performed at powder X-ray diffraction beamlines at the National Synchrotron Light Source II at Brookhaven National Laboratory and the Advanced Photon Source at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

Bunch mode specific rate corrections for PILATUS3 detectors

PILATUS X-ray detectors are in operation at many synchrotron beamlines around the world. This article reports on the characterization of the new PILATUS3 detector generation at high count rates. As for all counting detectors, the measured intensities have to be corrected for the dead-time of the counting mechanism at high photon fluxes. The large number of different bunch modes at these synchrotrons as well as the wide range of detector settings presents a challenge for providing accurate corrections. To avoid the intricate measurement of the count rate behaviour for every bunch mode, a Monte Carlo simulation of the counting mechanism has been implemented, which is able to predict the corrections for arbitrary bunch modes and a wide range of detector settings. This article compares the simulated results with experimental data acquired at different synchrotrons. It is found that the usage of bunch mode specific corrections based on this simulation improves the accuracy of the measured intensities by up to 40% for high photon rates and highly structured bunch modes. For less structured bunch modes, the instant retrigger technology of PILATUS3 detectors substantially reduces the dependency of the rate correction on the bunch mode. The acquired data also demonstrate that the instant retrigger technology allows for data acquisition up to 15 million photons per second per pixel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of online IGRT techniques for prostate IMRT treatment: Adaptive vs repositioning correction

This study compares three online image guidance techniques (IGRT) for prostate IMRT treatment: bony-anatomy matching, soft-tissue matching, and online replanning. Six prostate IMRT patients were studied. Five daily CBCT scans from the first week were acquired for each patient to provide representative ''snapshots'' of anatomical variations during the course of treatment. Initial IMRT plans were designed for each patient with seven coplanar 15 MV beams on a Eclipse treatment planning system. Two plans were created, one with a PTV margin of 10 mm and another with a 5 mm PTV margin. Based on these plans, the delivered dose distributions to each CBCT anatomy was evaluated to compare bony-anatomy matching, soft-tissue matching, and online replanning. Matching based on bony anatomy was evaluated using the 10 mm PTV margin (''bone10''). Soft-tissue matching was evaluated using both the 10 mm (''soft10'') and 5 mm (''soft5'') PTV margins. Online reoptimization was evaluated using the 5 mm PTV margin (''adapt''). The replanning process utilized the original dose distribution as the basis and linear goal programming techniques for reoptimization. The reoptimized plans were finished in less than 2 min for all cases. Using each IGRT technique, the delivered dose distribution was evaluated on all 30 CBCT scans (6 patientsx5CBCT/patient). The mean minimum dose (in percentage of prescription dose) to the CTV over five treatment fractions were in the ranges of 99%-100%(SD=0.1%-0.8%), 65%-98%(SD=0.4%-19.5%), 87%-99%(SD=0.7%-23.3%), and 95%-99%(SD=0.4%-10.4%) for the adapt, bone10, soft5, and soft10 techniques, respectively. Compared to patient position correction techniques, the online reoptimization technique also showed improvement in OAR sparing when organ motion/deformations were large. For bladder, the adapt technique had the best (minimum) D90, D50, and D30 values for 24, 17, and 15 fractions out of 30 total fractions, while it also had the best D90, D50, and D30 values for the rectum for 25, 16, and 19 fractions, respectively. For cases where the adapt plans did not score the best for OAR sparing, the gains of the OAR sparing in the repositioning-based plans were accompanied by an underdosage in the target volume. To further evaluate the fast online replanning technique, a gold-standard plan (''new'' plan) was generated for each CBCT anatomy on the Eclipse treatment planning system. The OAR sparing from the online replanning technique was compared to the new plan. The differences in D90, D50, and D30 of the OARs between the adapt and the new plans were less than 5% in 3 patients and were between 5% and 10% for the remaining three. In summary, all IGRT techniques could be sufficient to correct simple geometrical variations. However, when a high degree of deformation or differential organ position displacement occurs, the online reoptimization technique is feasible with less than 2 min optimization time and provides improvements in both CTV coverage and OAR sparing over the position correction techniques. For these cases, the reoptimization technique can be a highly valuable online IGRT tool to correct daily treatment uncertainties, especially when hypofractionation scheme is applied and daily correction, rather than averaging over many fractions, is required to match the original plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Beam-centric algorithm for pretreatment patient position correction in external beam radiation therapy

Purpose: In current image guided pretreatment patient position adjustment methods, image registration is used to determine alignment parameters. Since most positioning hardware lacks the full six degrees of freedom (DOF), accuracy is compromised. The authors show that such compromises are often unnecessary when one models the planned treatment beams as part of the adjustment calculation process. The authors present a flexible algorithm for determining optimal realizable adjustments for both step-and-shoot and arc delivery methods. Methods: The beam shape model is based on the polygonal intersection of each beam segment with the plane in pretreatment image volume that passes through machine isocenter perpendicular to the central axis of the beam. Under a virtual six-DOF correction, ideal positions of these polygon vertices are computed. The proposed method determines the couch, gantry, and collimator adjustments that minimize the total mismatch of all vertices over all segments with respect to their ideal positions. Using this geometric error metric as a function of the number of available DOF, the user may select the most desirable correction regime. Results: For a simulated treatment plan consisting of three equally weighted coplanar fixed beams, the authors achieve a 7% residual geometric error (with respect to the ideal correction, considered 0% error) by applying gantry rotation as well as translation and isocentric rotation of the couch. For a clinical head-and-neck intensity modulated radiotherapy plan with seven beams and five segments per beam, the corresponding error is 6%. Correction involving only couch translation (typical clinical practice) leads to a much larger 18% mismatch. Clinically significant consequences of more accurate adjustment are apparent in the dose volume histograms of target and critical structures. Conclusions: The algorithm achieves improvements in delivery accuracy using standard delivery hardware without significantly increasing total treatment session duration. It encourages parsimonious utilization of all available DOF. Finally, in certain cases, it obviates the need of a robotic couch having six DOF for the correction of patient displacement and rotations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technical Note: Modification of the standard gain correction algorithm to compensate for the number of used reference flat frames in detector performance studies

Purpose: The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (FPN) to avoid contamination from nonstochastic processes. The ''gold standard'' method used for the reduction of the FPN (i.e., the different gain between pixels) in linear x-ray detectors is based on normalization with an average reference flat-field. However, the noise in the corrected image depends on the number of flat frames used for the average flat image. The aim of this study is to modify the standard gain correction algorithm to make it independent on the used reference flat frames. Methods: Many publications suggest the use of 10-16 reference flat frames, while other studies use higher numbers (e.g., 48 frames) to reduce the propagated noise from the average flat image. This study quantifies experimentally the effect of the number of used reference flat frames on the NPS and DQE values and appropriately modifies the gain correction algorithm to compensate for this effect. Results: It is shown that using the suggested gain correction algorithm a minimum number of reference flat frames (i.e., down to one frame) can be used to eliminate the FPN from the raw flat image. This saves computer memory and time during the x-ray performance evaluation. Conclusions: The authors show that the method presented in the study (a) leads to the maximum DQE value that one would have by using the conventional method and very large number of frames and (b) has been compared to an independent gain correction method based on the subtraction of flat-field images, leading to identical DQE values. They believe this provides robust validation of the proposed method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection and correction for EPID and gantry sag during arc delivery using cine EPID imaging

Purpose: Electronic portal imaging devices (EPIDs) have been studied and used for pretreatment and in-vivo dosimetry applications for many years. The application of EPIDs for dosimetry in arc treatments requires accurate characterization of the mechanical sag of the EPID and gantry during rotation. Several studies have investigated the effects of gravity on the sag of these systems but each have limitations. In this study, an easy experiment setup and accurate algorithm have been introduced to characterize and correct for the effect of EPID and gantry sag during arc delivery. Methods: Three metallic ball bearings were used as markers in the beam: two of them fixed to the gantry head and the third positioned at the isocenter. EPID images were acquired during a 360 deg. gantry rotation in cine imaging mode. The markers were tracked in EPID images and a robust in-house developed MATLAB code was used to analyse the images and find the EPID sag in three directions as well as the EPID + gantry sag by comparison to the reference gantry zero image. The algorithm results were then tested against independent methods. The method was applied to compare the effect in clockwise and counter clockwise gantry rotations and different source-to-detector distances (SDDs). The results were monitored for one linear accelerator over a course of 15 months and six other linear-accelerators from two treatment centers were also investigated using this method. The generalized shift patterns were derived from the data and used in an image registration algorithm to correct for the effect of the mechanical sag in the system. The Gamma evaluation (3%, 3 mm) technique was used to investigate the improvement in alignment of cine EPID images of a fixed field, by comparing both individual images and the sum of images in a series with the reference gantry zero image. Results: The mechanical sag during gantry rotation was dependent on the gantry angle and was larger in the in-plane direction, although the patterns were not identical for various linear-accelerators. The reproducibility of measurements was within 0.2 mm over a period of 15 months. The direction of gantry rotation and SDD did not affect the results by more than 0.3 mm. Results of independent tests agreed with the algorithm within the accuracy of the measurement tools. When comparing summed images, the percentage of points with Gamma index <1 increased from 85.4% to 94.1% after correcting for the EPID sag, and to 99.3% after correction for gantry + EPID sag. Conclusions: The measurement method and algorithms introduced in this study use cine-images, are highly accurate, simple, fast, and reproducible. It tests all gantry angles and provides a suitable automatic analysis and correction tool to improve EPID dosimetry and perform comprehensive linac QA for arc treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of a free-running synchronization artifact correction for MV-imaging with aSi:H flat panels

Purpose: Solid state flat panel electronic portal imaging devices (EPIDs) are widely used for megavolt (MV) photon imaging applications in radiotherapy. In addition to their original purpose in patient position verification, they are convenient to use in quality assurance and dosimetry to verify beam geometry and dose deposition or to perform linear accelerator (linac) calibration procedures. However, native image frames from amorphous silicon (aSi:H) detectors show a range of artifacts which have to be eliminated by proper correction algorithms. When a panel is operated in free-running frame acquisition mode, moving vertical stripes (periodic synchronization artifacts) are a disturbing feature in image frames. Especially for applications in volumetric intensity modulated arc therapy (VMAT) or motion tracking, the synchronization (sync) artifacts are the limiting factor for potential and accuracy since they become even worse at higher frame rates and at lower dose rates, i.e., linac pulse repetition frequencies (PRFs). Methods: The authors introduced a synchronization correction method which is based on a theoretical model describing the interferences of the panel's readout clocking with the linac's dose pulsing. Depending on the applied PRF, a certain number of dose pulses is captured per frame which is readout columnwise, sequentially. The interference of the PRF with the panel readout is responsible for the period and the different gray value levels of the sync stripes, which can be calculated analytically. Sync artifacts can then be eliminated multiplicatively in precorrected frames without additional information about radiation pulse timing. Results: For the analysis, three aSi:H EPIDs of various types were investigated with 6 and 15 MV photon beams at varying PRFs of 25, 50, 100, 200, and 400 pulses per second. Applying the sync correction at panels with gadolinium oxysulfide scintillators improved single frame flood field image quality drastically [improvement of the signal-to-noise ratio (SNR) up to 66.1 dB for 6 MV and 66.0 dB for 15 MV]. Also for the EPID with a caesium iodide scintillator, the noise for the lower PRFs could be reduced (SNR at 6 MV of up to 56.3 dB and at 15 MV up to 46.7 dB). However, the simplistic readout interference model fails at higher PRFs, where image lag and ghosting effects due to trapped charges in the thin film transistor and scintillator postglowing require additional corrections. Conclusions: The presented free-running sync correction method improves SNR of single frames and enables imaging applications, like low-dose rate imaging at increased image frame rates (e.g., to track moving gold fiducials in the lung). Adaptive image guided radiotherapy protocols become even feasible in VMAT plans. Also simultaneous kilovolt and MV imaging applications can benefit from new possibilities of MV scatter removal in x-ray images.

60 APPLIED LIFE SCIENCES↗

Correcting radiation survey data to account for increased leakage during intensity modulated radiotherapy treatments

Purpose: Intensity modulated radiotherapy (IMRT) treatments require more beam-on time and produce more linac head leakage to deliver similar doses to conventional, unmodulated, radiotherapy treatments. It is necessary to take this increased leakage into account when evaluating the results of radiation surveys around bunkers that are, or will be, used for IMRT. The recommended procedure of applying a monitor-unit based workload correction factor to secondary barrier survey measurements, to account for this increased leakage when evaluating radiation survey measurements around IMRT bunkers, can lead to potentially costly overestimation of the required barrier thickness. This study aims to provide initial guidance on the validity of reducing the value of the correction factor when applied to different radiation barriers (primary barriers, doors, maze walls, and other walls) by evaluating three different bunker designs.Methods: Radiation survey measurements of primary, scattered, and leakage radiation were obtained at each of five survey points around each of three different radiotherapy bunkers and the contribution of leakage to the total measured radiation dose at each point was evaluated. Measurements at each survey point were made with the linac gantry set to 12 equidistant positions from 0° to 330°, to assess the effects of radiation beam direction on the results.Results: For all three bunker designs, less than 0.5% of dose measured at and alongside the primary barriers, less than 25% of the dose measured outside the bunker doors and up to 100% of the dose measured outside other secondary barriers was found to be caused by linac head leakage.Conclusions: Results of this study suggest that IMRT workload corrections are unnecessary, for survey measurements made at and alongside primary barriers. Use of reduced IMRT workload correction factors is recommended when evaluating survey measurements around a bunker door, provided that a subset of the measurements used in this study are repeated for the bunker in question. Reduction of the correction factor for other secondary barrier survey measurements is not recommended unless the contribution from leakage is separately evaluated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new correction method serving to eliminate the parabola effect of flatbed scanners used in radiochromic film dosimetry

Purpose: The purpose of this study is the correction of the lateral scanner artifact, i.e., the effect that, on a large homogeneously exposed EBT3 film, a flatbed scanner measures different optical densities at different positions along thex axis, the axis parallel to the elongated light source. At constant dose, the measured optical densitiy profiles along this axis have a parabolic shape with significant dose dependent curvature. Therefore, the effect is shortly called the parabola effect. The objective of the algorithm developed in this study is to correct for the parabola effect. Any optical density measured at given position x is transformed into the equivalent optical density c at the apex of the parabola and then converted into the corresponding dose via the calibration of c versus dose. Methods: For the present study EBT3 films and an Epson 10000XL scanner including transparency unit were used for the analysis of the parabola effect. The films were irradiated with 6 MV photons from an Elekta Synergy accelerator in a RW3 slab phantom. In order to quantify the effect, ten film pieces with doses graded from 0 to 20.9 Gy were sequentially scanned at eight positions along thex axis and at six positions along the z axis (the movement direction of the light source) both for the portrait and landscape film orientations. In order to test the effectiveness of the new correction algorithm, the dose profiles of an open square field and an IMRT plan were measured by EBT3 films and compared with ionization chamber and ionization chamber array measurement. Results: The parabola effect has been numerically studied over the whole measuring field of the Epson 10000XL scanner for doses up to 20.9 Gy and for both film orientations. The presented algorithm transforms any optical density at positionx into the equivalent optical density that would be measured at the same dose at the apex of the parabola. This correction method has been validated up to doses of 5.2 Gy all over the scanner bed with 2D dose distributions of an open square photon field and an IMRT distribution. Conclusions: The algorithm presented in this study quantifies and corrects the parabola effect of EBT3 films scanned in commonly used commercial flatbed scanners at doses up to 5.2 Gy. It is easy to implement, and no additional work steps are necessary in daily routine film dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-10: A Moving-Blocker-Based Strategy for Simultaneous Megavoltage and Kilovoltage Scatter Correction in Cone-Beam Computed Tomography Image Acquired During Volumetric Modulated Arc Therapy

Purpose: To evaluate a moving-blocker-based approach in estimating and correcting megavoltage (MV) and kilovoltage (kV) scatter contamination in kV cone-beam computed tomography (CBCT) acquired during volumetric modulated arc therapy (VMAT). Methods: XML code was generated to enable concurrent CBCT acquisition and VMAT delivery in Varian TrueBeam developer mode. A physical attenuator (i.e., “blocker”) consisting of equal spaced lead strips (3.2mm strip width and 3.2mm gap in between) was mounted between the x-ray source and patient at a source to blocker distance of 232mm. The blocker was simulated to be moving back and forth along the gantry rotation axis during the CBCT acquisition. Both MV and kV scatter signal were estimated simultaneously from the blocked regions of the imaging panel, and interpolated into the un-blocked regions. Scatter corrected CBCT was then reconstructed from un-blocked projections after scatter subtraction using an iterative image reconstruction algorithm based on constraint optimization. Experimental studies were performed on a Catphan 600 phantom and an anthropomorphic pelvis phantom to demonstrate the feasibility of using moving blocker for MV-kV scatter correction. Results: MV scatter greatly degrades the CBCT image quality by increasing the CT number inaccuracy and decreasing the image contrast, in addition to the shading artifacts caused by kV scatter. The artifacts were substantially reduced in the moving blocker corrected CBCT images in both Catphan and pelvis phantoms. Quantitatively, CT number error in selected regions of interest reduced from 377 in the kV-MV contaminated CBCT image to 38 for the Catphan phantom. Conclusions: The moving-blockerbased strategy can successfully correct MV and kV scatter simultaneously in CBCT projection data acquired with concurrent VMAT delivery. This work was supported in part by a grant from the Cancer Prevention and Research Institute of Texas (RP130109) and a grant from the American Cancer Society (RSG-13-326-01-CCE)

60 APPLIED LIFE SCIENCES↗

SU-E-J-175: Proton Dose Calculation On Scatter-Corrected CBCT Image: Feasibility Study for Adaptive Proton Therapy

Purpose: To demonstrate feasibility of proton dose calculation on scattercorrected CBCT images for the purpose of adaptive proton therapy. Methods: Two CBCT image sets were acquired from a prostate cancer patient and a thorax phantom using an on-board imaging system of an Elekta infinity linear accelerator. 2-D scatter maps were estimated using a previously introduced CT-based technique, and were subtracted from each raw projection image. A CBCT image set was then reconstructed with an open source reconstruction toolkit (RTK). Conversion from the CBCT number to HU was performed by soft tissue-based shifting with reference to the plan CT. Passively scattered proton plans were simulated on the plan CT and corrected/uncorrected CBCT images using the XiO treatment planning system. For quantitative evaluation, water equivalent path length (WEPL) was compared in those treatment plans. Results: The scatter correction method significantly improved image quality and HU accuracy in the prostate case where large scatter artifacts were obvious. However, the correction technique showed limited effects on the thorax case that was associated with fewer scatter artifacts. Mean absolute WEPL errors from the plans with the uncorrected and corrected images were 1.3 mm and 5.1 mm in the thorax case and 13.5 mm and 3.1 mm in the prostate case. The prostate plan dose distribution of the corrected image demonstrated better agreement with the reference one than that of the uncorrected image. Conclusion: A priori CT-based CBCT scatter correction can reduce the proton dose calculation error when large scatter artifacts are involved. If scatter artifacts are low, an uncorrected CBCT image is also promising for proton dose calculation when it is calibrated with the soft-tissue based shifting.

60 APPLIED LIFE SCIENCES↗

SU-E-T-96: Demonstration of a Consistent Method for Correcting Surface Dose Measurements Using Both Solid State and Ionization Chamber Detectors

Purpose: To compare the surface dose (SD) measured using a PTW 30-360 extrapolation chamber with different commonly used dosimeters (Ds): parallel plate ion chambers (ICs): RMI-449 (Attix), Capintec PS-033, PTW 30-329 (Markus) and Memorial; TLD chips (cTLD), TLD powder (pTLD), optically stimulated (OSLs), radiochromic (EXR2) and radiographic (EDR2) films, and to provide an intercomparison correction to Ds for each of them. Methods: Investigations were performed for a 6 MV x-ray beam (Varian Clinac 2300, 10x10 cm{sup 2} open field, SSD = 100 cm). The Ds were placed at the surface of the solid water phantom and at the reference depth dref=1.7cm. The measurements for cTLD, OSLs, EDR2 and EXR2 were corrected to SD using an extrapolation method (EM) indexed to the baseline PTW 30-360 measurements. A consistent use of the EM involved: 1) irradiation of three Ds stacked on top of each other on the surface of the phantom; 2) measurement of the relative dose value for each layer; and, 3) extrapolation of these values to zero thickness. An additional measurement was performed with externally exposed OSLs (eOSLs), that were rotated out of their protective housing. Results: All single Ds measurements overestimated the SD compared with the extrapolation chamber, except for Attix IC. The closest match to the true SD was measured with the Attix IC (− 0.1%), followed by pTLD (0.5%), Capintec (4.5%), Memorial (7.3%), Markus (10%), cTLD (11.8%), eOSL (12.8%), EXR2 (14%), EDR2 (14.8%) and OSL (26%). The EM method of correction for SD worked well for all Ds, except the unexposed OSLs. Conclusion: This EM cross calibration of solid state detectors with an extrapolation or Attix chamber can provide thickness corrections for cTLD, eOSLs, EXR2, and EDR2. Standard packaged OSLs were not found to be simply corrected.

60 APPLIED LIFE SCIENCES↗

SU-E-T-464: On the Equivalence of the Quality Correction Factor for Pencil Beam Scanning Proton Therapy

Purpose: In current practice, most proton therapy centers apply IAEA TRS-398 reference dosimetry protocol. Quality correction factors (kQ) take into account in the dose determination process the differences in beam qualities used for calibration unit and for treatment unit. These quality correction factors are valid for specific reference conditions. TRS-398 reference conditions should be achievable in both scattered proton beams (i.e. DS) and scanned proton beams (i.e. PBS). However, it is not a priori clear if TRS-398 kQ data, which are based on Monte Carlo (MC) calculations in scattered beams, can be used for scanned beams. Using TOPAS-Geant4 MC simulations, the study aims to determine whether broad beam quality correction factors calculated in TRS-398 can be directly applied to PBS delivery modality. Methods: As reference conditions, we consider a 10×10×10 cm{sup 3} homogeneous dose distribution delivered by PBS system in a water phantom (32/10 cm range/modulation) and an air cavity placed at the center of the spread-out-Bragg-peak. In order to isolate beam differences, a hypothetical broad beam is simulated. This hypothetical beam reproduces exactly the same range modulation, and uses the same energy layers than the PBS field. Ion chamber responses are computed for the PBS and hypothetical beams and then compared. Results: For an air cavity of 2×2×0.2 cm{sup 3}, the ratio of ion chamber responses for the PBS and hypothetical beam qualities is 0.9991 ± 0.0016. Conclusion: Quality correction factors are insensitive to the delivery pattern of the beam (broad beam or PBS), as long as similar dose distributions are achieved. This investigation, for an air cavity, suggests that broad beam quality correction factors published in TRS-398 can be applied for scanned beams. J. Sorriaux is financially supported by a public-private partnership involving the company Ion Beam Applications (IBA)

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-536: Inhomogeneity Correction in Planning of Gamma Knife Treatments for Acoustic Schwannoma

Purpose: To find out the dose difference on targets and organs at risk for the treatment of acoustic schwannoma if the inhomogeneity correction (Convolution algorithm) is applied. Methods: Images of patients treated for acoustic schwannoma with Gamma Knife using TMR 10 algorithm were retrieved from database and replanned with Convolution and TMR 10 algorithm respectively. These patients were treated using a preplan scheme in following: (1) Before the actual treatment day, using the MRI image that was taken without a head frame on the patient's skull, a pre-treatment plan was made based on the default skull coordinates in the Gamma Knife treatment planning system (LGP); (2) then on treatment day, a head frame was placed on the patient's skull, and a CT image was taken. The CT image with head frame was registered and fused with the completed preplan; (3) the treatment plan was finalized and the treatment was delivered. To find out the dosimetry impact of inhomogeneity correction, we used the retrieved CT images to replan the treatment using Convolution algorithm in LGP software version 10.1.1. The dose distributions and the dose volume histograms for targets and OARs were compared for these two dose calculation algorithms. Results: The dose calculated with the Convolution algorithm in general is slightly lower than the one from TMR 10 around the boney area. The effect from the inhomogeneity correction is observable but not significant, and varies with the location of the tumor. Conclusion: Inhomogeneity correction slightly improve the dose accuracy for acoustic schwannoma Gamma Knife treatments although the correction may not be very significant. Our Result provides evidence for dose prescription adjustment to treat acoustic schwannoma. The actual clinical outcome of switching from using TMR10 to using Convolution needs to be further investigated.

60 APPLIED LIFE SCIENCES↗