Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Coherent Frequency Reference System for the NASA Deep Space Network

The NASA Deep Space Network (DSN) requires state-of-the-art frequency references that are derived and distributed from very stable atomic frequency standards. A new Frequency Reference System (FRS) and Frequency Reference Distribution System (FRD) have been developed, which together replace the previous Coherent Reference Generator System (CRG). The FRS and FRD each provide new capabilities that significantly improve operability and reliability. The FRS allows for selection and switching between frequency standards, a flywheel capability (to avoid interruptions when switching frequency standards), and a frequency synthesis system (to generate standardized 5-, 10-, and 100-MHz reference signals). The FRS is powered by redundant, specially filtered, and sustainable power systems and includes a monitor and control capability for station operations to interact and control the frequency-standard selection process. The FRD receives the standardized 5-, 10-, and 100-MHz reference signals and distributes signals to distribution amplifiers in a fan out fashion to dozens of DSN users that require the highly stable reference signals. The FRD is also powered by redundant, specially filtered, and sustainable power systems. The new DSN Frequency Distribution System, which consists of the FRS and FRD systems described here, is central to all operational activities of the NASA DSN. The frequency generation and distribution system provides ultra-stable, coherent, and very low phase-noise references at 5, l0, and 100 MHz to between 60 and 100 separate users at each Deep Space Communications Complex.

Tucker, Blake C.↗

Soft x-ray array system with variable filters for the DIII-D tokamak

Recent upgrades to the soft x-ray (SXR) array system on the DIII-D tokamak are described. The system consists of two 32-channel arrays at one toroidal location and three toroidally distributed 12-channel arrays. The 32-channel arrays have been completely rebuilt to allow the switching of SXR filters without breaking vacuum. The 12-channel arrays have had upgrades performed to detectors, view slits, and data acquisition. Absolute extreme ultraviolet (AXUV) photodiodes are used as detectors in all arrays, allowing detection of photons ranging in energy from 2 eV to 10 keV. In the fixed-filter arrays, 127 {mu}m Be filters are used. In the variable-filter arrays, filter wheels are used to switch between five different possible pinhole/filter combinations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chebyshev-filtered subspace iteration method free of sparse diagonalization for solving the Kohn–Sham equation

First-principles density functional theory (DFT) calculations for the electronic structure problem require a solution of the Kohn–Sham equation, which requires one to solve a nonlinear eigenvalue problem. Solving the eigenvalue problem is usually the most expensive part in DFT calculations. Sparse iterative diagonalization methods that compute explicit eigenvectors can quickly become prohibitive for large scale problems. The Chebyshev-filtered subspace iteration (CheFSI) method avoids most of the explicit computation of eigenvectors and results in a significant speedup over iterative diagonalization methods for the DFT self-consistent field (SCF) calculations. However, the original formulation of the CheFSI method utilizes a sparse iterative diagonalization at the first SCF step to provide initial vectors for subspace filtering at latter SCF steps. This diagonalization is expensive for large scale problems. We develop a new initial filtering step to avoid completely this diagonalization, thus making the CheFSI method free of sparse iterative diagonalizations at all SCF steps. Our new approach saves memory usage and can be two to three times faster than the original CheFSI method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fluidized-bed atomic layer deposition reactor for the synthesis of core-shell nanoparticles

The design of a fluidized bed atomic layer deposition (ALD) reactor is described in detail. The reactor consists of three parts that have all been placed in one protective cabinet: precursor dosing, reactor, and residual gas treatment section. In the precursor dosing section, the chemicals needed for the ALD reaction are injected into the carrier gas using different methods for different precursors. The reactor section is designed in such a way that a homogeneous fluidized bed can be obtained with a constant, actively controlled, reactor pressure. Furthermore, no filters are required inside the reactor chamber, minimizing the risk of pressure increase due to fouling. The residual gas treatment section consists of a decomposition furnace to remove residual precursor and a particle filter and is installed to protect the pump. In order to demonstrate the performance of the reactor, SiO{sub 2} particles have been coated with TiO{sub 2} using tetrakis-dimethylamino titanium (TDMAT) and H{sub 2}O as precursors. Experiments with varying pulse times show that saturated growth can be obtained with TDMAT pulse times larger than 600 s. Analysis of the powder with High-Angle Annular Dark-Field Scanning Transmission Electron Microscopy (HAADF-STEM) and energy dispersive X-ray spectroscopy confirmed that after 50 cycles, all SiO{sub 2} particles were coated with a 1.6 nm homogenous shell of TiO{sub 2}.

36 MATERIALS SCIENCE↗

Efficient spin filter and spin valve in a single-molecule magnet Fe{sub 4} between two graphene electrodes

We propose a magnetic molecular junction consisting of a single-molecule magnet Fe{sub 4} connected two graphene electrodes and investigate transport properties, using the nonequilibrium Green's function method in combination with spin-polarized density-functional theory. The results show that the device can be used as a nearly perfect spin filter with efficiency approaching 100%. Our calculations provide crucial microscopic information how the four iron cores of the chemical structure are responsible for the spin-resolved transmissions. Moreover, it is also found that the device behaves as a highly efficient spin valve, which is an excellent candidate for spintronics of molecular devices. The idea of combining single-molecule magnets with graphene provides a direction in designing a new class of molecular spintronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Between-Simulator Comparison of Motion Filter Order and Break Frequency Interaction Effects on Pilot Control Behavior

This paper investigates the interaction effects of motion filter order and break frequency on pilots' manual control behavior and control performance using two simulators. Eighteen pilots performed the experiment in the Vertical Motion Simulator (VMS) at NASA Ames Research Center and twenty pilots in the SIMONA Research Simulator at Delft University of Technology. The experiment used a full-factorial design with three motion filter orders (first-, second-, and third-order) and two filter break frequencies (0.5 and 2.0 rad/s), in addition to reference no-motion and full-motion conditions. Key task variables, such as the quality of the motion and visual cues and the characteristics of the sidestick, were matched across both simulators. Overall, the expected effects of filter order and break frequency variations were found, with both increasing order and increasing break frequency causing pilots to use less motion feedback in their control strategy, resulting in lower tracking performance. Furthermore, across the wide range of filter orders tested in the experiment, the existing Sinacori-Schroeder motion fidelity criterion was found to be a good predictor of the interaction effects of both filter settings on pilot control behavior. For the same motion condition, there was a consistent offset in the results between simulators, due to the more high-gain control strategy adopted by a number of the VMS pilots. Still, the observed relative trends in pilot control behavior and performance between motion conditions were equivalent in both simulators and thus accurately replicated.

manual control↗

Temporal Variations in Jupiter's Atmosphere

In recent years, Jupiter has undergone many atmospheric changes from storms turning red to global. cloud upheavals, and most recently, a cornet or asteroid impact. Yet, on top of these seemingly random changes events there are also periodic phenomena, analogous to observed Earth and Saturn atmospheric oscillations. We will present 15 years of Hubble data, from 1994 to 2009, to show how the equatorial tropospheric cloud deck and winds have varied over that time, focusing on the F953N, F41 ON and F255W filters. These filters give leverage on wind speeds plus cloud opacity, cloud height and tropospheric haze thickness, and stratospheric haze, respectively. The wind data consistently show a periodic oscillation near 7-8 S latitude. We will discuss the potential for variations with longitude and cloud height, within the calibration limits of those filters. Finally, we will discuss the role that large atmospheric events, such as the impacts in 1994 and 2009, and the global upheaval of 2007, have on temporal studies, This work was supported by a grant from the NASA Planetary Atmospheres Program. HST observational support was provided by NASA through grants from Space Telescope Science Institute, which is operated by the Association of Universities for Research in Astronomy, Inc., under contract NAS5-26555.

Simon-Miller, Amy A.↗

Evaluation of alternative filter media for particulate matter emission testing of residential wood heating devices

The performance of Teflon-coated glass fiber filter media (Pallflex Emfab TX40) is evaluated for particulate matter (PM) sampling of residential wood heating devices in a dilution tunnel. Thirty samples of varying duration and PM loading and concentration were collected from an U.S. Environmental Protection Agency (EPA) Method 28 dilution tunnel using dual Method 5G sample trains with untreated glass fiber and Emfab filters. Filters were weighed soon after the end of sampling and again the next day after equilibration at 35% relative humidity (RH). PM concentrations from both types of filters agreed very well with 1-day equilibration, demonstrating that Emfab filters are appropriate for use in measuring PM from residential wood burning appliances in a dilution tunnel and have performance equal to or better than the glass fiber filter media. Agreement between filter media without equilibration was erratic, with PM from glass fiber filter samples varying from slightly less than the Emfab samples to as much as 2.8 times higher. Some of the glass fiber filters lost substantial mass with equilibration, with the highest percent loss at lower filter mass loadings. Mass loss for Emfab samples was a small percentage of the mass and very consistent across the range of mass loadings. Taken together, these results may indicate water uptake on the glass fiber media that is readily removed with 1-day equilibration at moderate RH conditions. Implications: EPA regulations now allow the use of either glass fiber or Teflon filter media for wood appliance PM emission testing. Teflon filter media minimizes the potential for acid-gas PM artifacts on glass fiber filters; this is important as EPA moves toward the use of locally sourced cordwood for testing that may have higher sulfur content. This work demonstrates that the use of Teflon-coated glass fiber filters can give similar PM measurement results to glass fiber filters after 1 day of equilibration. With no equilibration, measured PM from glass fiber filters was usually higher than from Teflon-coated glass fiber filters.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Long term variability of transmission of thin In-Sn and Sn-C films for EUV instrumentation

The transmission variability is reported for two filters in the EUV, where the filters were supported on an 80% transmission nickel mesh and fabricated by means of a vacuum deposition technique. The first film consisted of 2500 A-thick indium, deposited on 500 A-thick tin, and had its primary bandpass in the 740-960 A range. The second consisted of 1800 A-thick tin and 2000 A-thick carbon, with a bandpass of 500-750 A. At the end of 10 months, the transmission of both filters was measured to check variations. It is demonstrated that the EUV transmission of such filters can change over the typical lifetime of satellite missions, and that such variation depends on the storage environment. The use of vacuum, rather than dry nitrogen storage is recommended.

Chakrabarti, S.↗

A Kalman Filter for Mass Property and Thrust Identification of the Spin-Stabilized Magnetospheric Multiscale Formation

The Magnetospheric Multiscale (MMS) mission consists of four identically instrumented, spin-stabilized observatories, elliptically orbiting the Earth in a tetrahedron formation. For the operational success of the mission, on-board systems must be able to deliver high-precision orbital adjustment maneuvers. On MMS, this is accomplished using feedback from on-board star sensors in tandem with accelerometers whose measurements are dynamically corrected for errors associated with a spinning platform. In order to determine the required corrections to the measured acceleration, precise estimates of attitude, rate, and mass-properties are necessary. To this end, both an on-board and ground-based Multiplicative Extended Kalman Filter (MEKF) were formulated and implemented in order to estimate the dynamic and quasi-static properties of the spacecraft.

Formation Flying↗

Legacy Survey of Space and Time Data Preview 2: Visit searchable catalog

We present Rubin Data Preview 2 (DP2), the second data preview from the NDF-DOE Vera C. Rubin Observatory. Data Preview 2 (DP2) comprises coadds, detection catalogs, and ancillary data products; and when fully released will also include single-epoch images and difference images. DP2 is derived from observations acquired by the LSST Science Camera (LSSTCam) on the Simonyi Survey Telescope at the Summit Facility on Cerro Pachón, Chile, primarily during the on-sky commissioning campaign between 2025-04-16 and 2025-09-21, supplemented by observations taken between 2025-10-25 and 2026-01-06 that overlap the commissioning footprint. The DP2 footprint comprises the Science Validation wide-area survey, five Deep Drilling Fields, and a number of targeted small-field regions, including Trifid and Lagoon, Prawn, M49, and New Horizons, all observed as part of the Rubin First Look campaign. Each field was imaged in up to six broad photometric bands, ugrizy, and coadded to produce deep imaging covering an estimated 3,000 deg2. The addition of single-visit-only areas expands the total DP2 footprint to an estimated 15,000 deg2, with coverage in at least one filter. The median per-visit PSF FWHM across the wide-area survey ranges from 1.17 arcsec in the z band to 1.26 arcsec in g and r bands. The deepest field, reaches estimated coadded 5σ depths of u=26 mag, g=26.8 mag, r=26.3 mag, i=26.1 mag, z=25.3 mag, y=23.9 mag. Based on a roughly five-month primary observing baseline and covering only part of the eventual LSST footprint, DP2's area, depth, and multiband coverage nonetheless support a broad range of early science investigations ahead of LSST Data Release This dataset is a subset of the full data release consisting of a searchable catalog named Visit. This catalog contains metadata, including dates and filters for every visit. This catalog contains 28,698 rows with 15 columns.

79 ASTRONOMY AND ASTROPHYSICS↗

KIPM Detector Characterization in QUIET

Kinetic Inductance Phonon‑Mediated (KIPM) detectors are superconducting microwave resonators that sense energy depositions in the substrate through a transient shift in their resonant frequency. In this work, I installed new devices in the QUIET cryogenic facility and used a network analyzer to drive them across a range of power levels. At each setting, I measured the transmitted signal and fit it to a simple notch‑filter model, allowing us to extract key performance metrics. Despite the increased noise at low power, the model consistently captured the resonance behavior. I first measured the resonance parameters as a function of RF drive power, then repeated the measurement across a range of temperatures to test whether the device behaved like an MKID. While the notch-filter fits captured the resonance reliably, the observed temperature dependence did not match the expected MKID signature — indicating that these first in-house fabricated chips are not yet functioning as true MKIDs. Overall, this reframes our work as a study of resonance parameter extraction and identification, pointing towards future iterations of device design and fabrication to get the true MKID response.

Savitala, Akash [U. Washington, Seattle (main); Fe↗

Signal-Preserving Erratic Noise Attenuation via Iterative Robust Sparsity-Promoting Filter

Sparse domain thresholding filters operating in a sparse domain are highly effective in removing Gaussian random noise under Gaussian distribution assumption. Erratic noise, which designates non-Gaussian noise that consists of large isolated events with known or unknown distribution, also needs to be explicitly taken into account. However, conventional sparse domain thresholding filters based on the least-squares (LS) criterion are severely sensitive to data with high-amplitude and non-Gaussian noise, i.e., the erratic noise, which makes the suppression of this type of noise extremely challenging. Here, in this paper, we present a robust sparsity-promoting denoising model, in which the LS criterion is replaced by the Huber criterion to weaken the effects of erratic noise. The random and erratic noise is distinguished by using a data-adaptive parameter in the presented method, where random noise is described by mean square, while the erratic noise is downweighted through a damped weight. Different from conventional sparse domain thresholding filters, definition of the misfit between noisy data and recovered signal via the Huber criterion results in a nonlinear optimization problem. With the help of theoretical pseudoseismic data, an iterative robust sparsity-promoting filter is proposed to transform the nonlinear optimization problem into a linear LS problem through an iterative procedure. The main advantage of this transformation is that the nonlinear denoising filter can be solved by conventional LS solvers. Lastly, tests with several data sets demonstrate that the proposed denoising filter can successfully attenuate the erratic noise without damaging useful signal when compared with conventional denoising approaches based on the LS criterion.

97 MATHEMATICS AND COMPUTING↗

Bases of Bacterial Sodium Channel Selectivity Among Organic Cations

Hille’s (1971) seminal study of organic cation selectivity of eukaryotic voltage-gated sodium channels showed a sharp size cut-off for ion permeation, such that no ion possessing a methyl group was permeant. Using the prokaryotic channel, NaChBac, we found some similarity and two peculiar differences in the selectivity profiles for small polyatomic cations. First, we identified a diverse group of minimally permeant cations for wildtype NaChBac, ranging in sizes from ammonium to guanidinium and tetramethylammonium; and second, for both ammonium and hydrazinium, the charge-conserving selectivity filter mutation (E191D) yielded substantial increases in relative permeability (P X /P Na ). The relative permeabilities varied inversely with relative Kd calculated from 1D Potential of Mean Force profiles (PMFs) for the single cations traversing the channel. Several of the cations bound more strongly than Na + , and hence appear to act as blockers, as well as charge carriers. Consistent with experimental observations, the E191D mutation had little impact on Na+ binding to the selectivity filter, but disrupted the binding of ammonium and hydrazinium, consequently facilitating ion permeation across the NaChBac-like filter. We concluded that for prokaryotic sodium channels, a fine balance among filter size, binding affinity, occupancy, and flexibility seems to contribute to observed functional differences.

59 BASIC BIOLOGICAL SCIENCES↗

The multi-spectral line-polarization MSE system on Alcator C-Mod

A multi-spectral line-polarization motional Stark effect (MSE-MSLP) diagnostic has been developed for the Alcator C-Mod tokamak wherein the Stokes vector is measured in multiple wavelength bands simultaneously on the same sightline to enable better polarized background subtraction. A ten-sightline, four wavelength MSE-MSLP detector system was designed, constructed, and qualified. This system consists of a high-throughput polychromator for each sightline designed to provide large étendue and precise spectral filtering in a cost-effective manner. Each polychromator utilizes four narrow bandpass interference filters and four custom large diameter avalanche photodiode detectors. Two filters collect light to the red and blue of the MSE emission spectrum while the remaining two filters collect the beam pi and sigma emission generated at the same viewing volume. The filter wavelengths are temperature tuned using custom ovens in an automated manner. All system functions are remote controllable and the system can be easily retrofitted to existing single-wavelength line-polarization MSE systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NIRCam: The JWST Near-IR Camera and Slitless Spectrograph

NIRCam is the primary near-infrared camera for JWST. It is well-suited for a wide variety of star formation and other scientific studies and will also be used for aligning the JWST primary mirror segments and telescope. NIRCam will provide high sensitivity, high spatial resolution images in a variety of filters over the 0.6 - 5 μm wavelength region including coronagraphic modes and slitless spectroscopic capabilities. NIRCam consists of two identical optical modules that have adjacent 2.2' x 2.2' fields of view on the sky. Each module is composed of two channels that observe the same field at short (< 2.4 μm) or long (> 2.4 μm) wavelengths simultaneously, with optimized spatial sampling in each channel. NIRCam optical elements include narrow (R = 100), medium (R = 10), and wide (R <= 4) filters, coronagraphic imaging spot and bar masks, and grisms that provide wide-field or time-series slitless spectroscopy. These major NIRCam features will be introduced, and some applications to galactic star formation will be briefly presented.

Greene, Thomas↗

Hyper Spectral Anomaly Detection

The HSA is a statistics based anomaly detection model. The model performs unsupervised anomaly detection, based on a datapoint's density and similarity within a dataset. Density and similarity data are encoded into an affinity matrix. The affinity matrix is evolved to summarize the data's structure on greater topographical scales within the data's function space. The set of evolved affinity matrices and an anomaly score vector are passed to a user defined penalized objective function. The penalized objective function of anomaly scores is then minimized. Data points where the absolute value of the z-scores of anomaly scores greater than a specified threshold are predicted as anomalies. A novel multi-filter feature has also been implemented. To reduce false positive rates, the multi-filter records the indexes of the HSA predictions. A new dataset and data loader are instantiated consisting of all the initial HSA predictions and non-anomalous data points in a 10% and 90% split respectively. The HSA is then run through this data set and a count of number of times a data point is predicted is kept. In this way the initial predictions may be compared with data spanning the entire dataset. After the multi-filter is complete, all datapoints will have an associated anomaly score, as well as a multi-filter prediction count to further filter the anomalous predictions.

Rogers, DempseyD [Idaho National Laboratory (INL),↗

Dark Energy Survey Year 1 Results: Photometric Data Set for Cosmology

Here, we describe the creation, content, and validation of the Dark Energy Survey (DES) internal year-one cosmology data set, Y1A1 GOLD, in support of upcoming cosmological analyses. The Y1A1 GOLD data set is assembled from multiple epochs of DES imaging and consists of calibrated photometric zeropoints, object catalogs, and ancillary data products -e.g., maps of survey depth and observing conditions, star-galaxy classification, and photometric redshift estimates|that are necessary for accurate cosmological analyses. The Y1A1 GOLD wide-area object catalog consists of 137 million objects detected in coadded images covering 1800 deg 2 in the DES grizY filters. The 10 limiting magnitude for galaxies is g = 23.4, r = 23.2, i = 22.5, z = 21.8, and Y = 20.1. We also performed photometric calibration of Y1A1 GOLD by combining nightly zeropoint solutions with stellar-locus regression, and the absolute calibration accuracy is better than 2% over the survey area. DES Y1A1 GOLD is the largest photometric data set at the achieved depth to date, enabling precise measurements of cosmic acceleration at z ≲1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗