Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “confidence intervals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pronghorn Porous Media Model Validation with Pressure Drop Measurements

The verification and validation (V&V) of Pronghorn is imperative to assert its accuracy when predicting the fluid velocity, temperature, and pressure in high temperature gas-cooled reactors. Pronghorn is a coarse-mesh, intermediate-fidelity, and multidimensional thermal-hydraulics (TH) code developed by the Idaho National Laboratory (INL). New pebble bed experiments are used to observe the details of the fluid motion and pressure drop in the porous bed under the reactor normal operation. This paper focuses on the validation of the Pronghorn compressible and incompressible Navier-Stokes equations using the pressure drop measurements performed at the engineering-scale pebble bed facility at the Texas A&M university (TAMU). Various pressure drop correlations and porosity functions are implemented in both Pronghorn and STAR-CCM+ to compare the pressure drop due to the combined viscous and inertial resistances in the porous bed. The correlations accounting for the near-wall effect are also utilized to observe if the pressure drop estimates can be improved. Pronghorn porous media models predict the pressure drop well relative to the STAR-CCM+ simulation results and 1D correlations, and both the finite element method (FEM) and finite volume method (FVM) perform accurately. Pronghorn models are also validated with the experimental measurements given the different Reynolds number ranges and specific aspect ratios. The likelihood of the statistical significance between the pressure drop measurements and specific correlations or simulations is low provided that the overlap of their confidence intervals is more than the half of a single arm. Several validation metrics are reasonable in regard to the similar studies from other literature. The precise average pebble bed porosity estimation has much impact on the pressure drop, and the Foumeny and Montillet (dense packing) models carry out the accurate pressure drop prediction by considering the near-wall effect.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Searching for Neutrino Tridents in the NOvA Near Detector

This dissertation presents a search for neutrino trident production in the NOvA near detector through the coherent ``dimuon" channel: $\nu_\mu +\hspace{1pt}\text{X} \rightarrow \nu_\mu + \mu^- + \mu^+ +\hspace{1pt}\text{X}$. Trident production is a rare, purely electroweak process with sensitivity to physics beyond the Standard Model. The theoretical background, motivation for studying the process, and previous experimental measurements are reviewed. The analysis uses data collected by the NOvA near detector (ND) from Fermilab's Neutrinos at the Main Injector (NuMI) beam between November 2014 and February 2024, corresponding to an exposure of $25.5\times 10^{20}$ protons on target. The ND is a segmented tracking calorimeter located 800~m from the beam target, receiving neutrinos with a mean energy of 2~GeV. A multi-pass background reduction strategy is implemented, including the development of a novel dimuon-specific tracking technique. Trident candidates are identified using a boost ed decision tree classifier trained on simulated signal and background events. Limited background Monte Carlo statistics necessitate the use of functional fits to sideband data, which are extrapolated to estimate backgrounds in the signal region. The unblinded data contain 9 trident-like events, with an estimated background of 5.66 $\pm$ 5.15 events. This yields a best fit estimate of 3.34 tridents compared to the Standard Model prediction of 4.66. A profiled Feldman-Cousins method is used to determine a 90\% confidence interval of [0,9.1] on the number of signal events, corresponding to an upper limit of 1.95$\times$ the Standard Model prediction. This result represents the lowest energy search for trident events to date, and the first experimental contribution to the process in 27 years.

Bowles, Reed Scott [Indiana U.]↗

Precision Interval Estimation of the Response Surface by Means of an Integrated Algorithm of Neural Network and Linear Regression

The integration of Radial Basis Function Networks and Back Propagation Neural Networks with the Multiple Linear Regression has been accomplished to map nonlinear response surfaces over a wide range of independent variables in the process of the Modem Design of Experiments. The integrated method is capable to estimate the precision intervals including confidence and predicted intervals. The power of the innovative method has been demonstrated by applying to a set of wind tunnel test data in construction of response surface and estimation of precision interval.

Lo, Ching F.↗

Constraining off-shell Higgs boson production and the Higgs boson total width using WW → ℓνℓν final states with the ATLAS detector

A measurement of off-shell Higgs boson production is performed in the H* → WW channel. The measurement uses a proton–proton collision dataset with an integrated luminosity of 140 fb -1 collected at a centre-of-mass energy of 13 TeV by the ATLAS detector at the Large Hadron Collider. Final states in which both W bosons decay leptonically are targeted, and events are categorised based on the flavour of the final-state leptons, the jet multiplicity, and the output of neural network-based classifiers. The data are found to be compatible with the Standard Model expectation. An observed (expected) upper bound on the 95 % symmetric confidence level interval is set on the rate of off-shell Higgs boson production at a value of 3.4 (4.4) times the Standard Model prediction. These results are combined with the results from the measurement of on-shell Higgs boson production in the same final states to obtain an observed (expected) upper bound at 95 % confidence level on the Higgs boson total width of 13.1 (17.3) MeV.

Aad, G. [Aix-Marseille Univ., Marseille (France)] ↗

Measurement and interpretation of same-sign W boson pair production in association with two jets in $pp$ collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

This paper presents the measurement of fiducial and differential cross sections for both the inclusive and electroweak production of a same-sign W-boson pair in association with two jets (W ± W ± jj) using 139 fb –1 of proton-proton collision data recorded at a centre-of-mass energy of $\sqrt{s}$ = 13 TeV by the ATLAS detector at the Large Hadron Collider. The analysis is performed by selecting two same-charge leptons, electron or muon, and at least two jets with large invariant mass and a large rapidity difference. The measured fiducial cross sections for electroweak and inclusive W ± W ± jj production are 2.92 ± 0.22 (stat.) ± 0.19 (syst.) fb and 3.38 ± 0.22 (stat.) ± 0.19 (syst.) fb, respectively, in agreement with Standard Model predictions. The measurements are used to constrain anomalous quartic gauge couplings by extracting 95% confidence level intervals on dimension-8 operators. A search for doubly charged Higgs bosons H ±± that are produced in vector-boson fusion processes and decay into a same-sign W boson pair is performed. The largest deviation from the Standard Model occurs for an H ±± mass near 450 GeV, with a global significance of 2.5 standard deviations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Zγ production cross section and search for anomalous neutral triple gauge couplings in pp collisions at $ \sqrt{s}=13 $ TeV

A measurement of the fiducial cross section of the associated production of a Z boson and a high-p$_{T}$ photon, where the Z decays to two neutrinos, and a search for anomalous triple gauge couplings are reported. The results are based on data collected by the CMS experiment at the LHC in proton-proton collisions at $ \sqrt{s}=13 $ TeV during 2016-2018, corresponding to an integrated luminosity of 138 fb$^{−1}$. The fiducial Zγ cross section, where a photon with a p$_{T}$ greater than 225 GeV is produced in association with a Z, and the Z decays to a $ \upnu \overline{\upnu} $ pair $ \left(\mathrm{Z}\left(\upnu \overline{\upnu}\right)\upgamma \right) $, is measured to be $ {23.3}_{-1.3}^{+1.4} $ fb, in agreement, within uncertainties, with the standard model prediction. The differential cross section as a function of the photon p$_{T}$ has been measured and compared with standard model predictions computed at next-to-leading and at next-to-next-to-leading order in perturbative quantum chromodynamics. Constraints have been placed on the presence of anomalous couplings that affect the ZZγ and Zγγ vertex using the p$_{T}$ spectrum of the photons. The observed 95% confidence level intervals for CP-conserving $ {h}_3^{\upgamma} $ and $ {h}_4^{\upgamma} $ are determined to be (−3.4, 3.5)×10$^{−4}$ and (−6.8, 6.8)×10$^{−7}$, and for $ {h}_3^{\mathrm{Z}} $ and $ {h}_4^{\mathrm{Z}} $ they are (−2.2, 2.2)×10$^{−4}$ and (−4.1, 4.2)×10$^{−7}$, respectively. These are the strictest limits to date on $ {h}_3^{\upgamma} $, $ {h}_3^{\mathrm{Z}} $ and $ {h}_4^{\mathrm{Z}} $.[graphic not available: see fulltext]

Hayrapetyan, Aram [Yerevan Phys. Inst.]↗

Probing effective field theory operators in the associated production of top quarks with a Z boson in multilepton final states at $\sqrt{s}$ = 13 TeV

A search for new top quark interactions is performed within the framework of an effective field theory using the associated production of either one or two top quarks with a Z boson in multilepton final states. The data sample corresponds to an integrated luminosity of 138 fb -1 of proton-proton collisions at √s = 13 TeV collected by the CMS experiment at the LHC. Five dimension-six operators modifying the electroweak interactions of the top quark are considered. Novel machine-learning techniques are used to enhance the sensitivity to effects arising from these operators. Distributions used for the signal extraction are parameterized in terms of Wilson coefficients describing the interaction strengths of the operators. All five Wilson coefficients are simultaneously fit to data and 95% confidence level intervals are computed. All results are consistent with the SM expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Statistical Uncertainty in Paleoclimate Proxy Reconstructions

A quantitative analysis of any environment older than the instrumental record relies on proxies. Uncertainties associated with proxy reconstructions are often underestimated, which can lead to artificial conflict between different proxies, and between data and models. In this paper, using ordinary least squares linear regression as a common example, we describe a simple, robust and generalizable method for quantifying uncertainty in proxy reconstructions. We highlight the primary controls on the magnitude of uncertainty, and compare this simple estimate to equivalent estimates from Bayesian, nonparametric and fiducial statistical frameworks. We discuss when it may be possible to reduce uncertainties, and conclude that the unexplained variance in the calibration must always feature in the uncertainty in the reconstruction. This directs future research toward explaining as much of the variance in the calibration data as possible. We also advocate for a “data-forward” approach, that clearly decouples the presentation of proxy data from plausible environmental inferences.

58 GEOSCIENCES↗

Observation of the $γγ → ττ$ Process in $\mathrm{Pb + Pb}$ Collisions and Constraints on the $\tau$-Lepton Anomalous Magnetic Moment with the ATLAS Detector

This Letter reports the observation of τ-lepton pair production in ultraperipheral lead-lead collisions, Pb+Pb→Pb(γγ→ττ)Pb, and constraints on the τ-lepton anomalous magnetic moment, a τ . The dataset corresponds to an integrated luminosity of 1.44 nb -1 of LHC Pb+Pb collisions at $\sqrt{s_{NN}}$ =5.02 TeV recorded by the ATLAS experiment in 2018. Selected events contain one muon from a τ-lepton decay, an electron or charged-particle track(s) from the other τ-lepton decay, little additional central-detector activity, and no forward neutrons. The γγ→ττ process is observed in Pb+Pb collisions with a significance exceeding 5 standard deviations, and a signal strength of μ ττ =1.03$^{+0.06}_{-0.05}$ assuming the Standard Model value for a τ . To measure a τ , a template fit to the muon transverse-momentum distribution from τ-lepton candidates is performed, using a dimuon (γγ→μμ) control sample to constrain systematic uncertainties. The observed 95% confidence-level interval for aτ is -0.057 < a τ < 0.024.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

My Virtual Cancer

Since each cancer has its own unique characteristics, each one can respond differently to the same treatments. Therefore, the creation of a digital twin (DT) of cancer can assist us in predicting the evolution of an individual's cancer through modeling each tumor's characteristics and response to treatment. Hence, we propose to take advantage of new advances in computational approaches and combine mechanistic, machine learning, and stochastic modeling approaches to create “My Virtual Cancer", a DT platform. To establish a personalized DT, we use patient-specific data for parameter estimations, sensitivity analysis, and uncertainty quantification. For each patient, we will estimate the values of parameters of their QSP model using the patient's data. We perform a multi-dimensional sensitivity analysis and uncertainty quantification on the mechanistic model to find a set of critical interactions and predict the intervals of confidence. Since this QSP model includes the data-driven mechanistic model of cells and molecules' interaction networks, one of the ultimate results of this DT would be the prediction of evolution of tumors.

60 APPLIED LIFE SCIENCES↗

Determination of Neutrino Oscillation Parameters through the Feldman-Cousins Method by the NOvA Experiment

The NOvA experiment presents new measurements of the neutrino oscillation parameters obtained through a fit to data from the one megawatt NuMI neutrino beam in the NOvA detectors. The analysis uses muon-neutrino disappearance and electron-neutrino appearance in both neutrino and antineutrino beam polarities. With the addition of $\sim$ 100%\) more neutrino-mode beam exposure over the previously reported results, this analysis employs the unified approach of Feldman and Cousins to determine the confidence level intervals for the oscillation parameters $\theta_{23}, \delta_{CP}$, and $\Delta m_{32}^2$ for both neutrino mass orderings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Saskatoon M. F. Radar System: (52 Deg N, 107 Deg W), Canada

The system runs continuously, producing 1-h profiles approx. 75 to 110 km, 1978 to 1983: in particular for the 30-d (Nov. 9 to Dec. 7), 10-d (Nov. 16 to 26), 4-d core periods (Nov. 19 to 23). The means (EW, NS) and fourier components (24-, 12-h) fitted for the 4-d are shown. s.d. are shown, as derived from four 24-h fits in the interval. Comparisons with the 10-, 30-d intervals confirm confidence in these data and the lack of major variability in November. The 1-h profiles are means of 12 profiles so intrinsic errors are minimal. The 4-, 10-d fourier fits are compared and also the 30-d means from 48-h fits; in these amplitudes are N2+E2 as N/E approx. 1. Means differ slightly due to planetary wave activity; 24-h tides are variable in Novembers; and the 12-h variation is small less than 80 km. The final figure is a high resolution spectra for the November month: the 12-, 24-h dominate; the 8-h appears less than 100 km; and up to 90 km there is a 4-d oscillation.

Manson, A. H.↗

Gender not a factor for altitude decompression sickness risk

INTRODUCTION: Early, retrospective reports of the incidence of altitude decompression sickness (DCS) during altitude chamber training exposures indicated that women were more susceptible than men. We hypothesized that a controlled, prospective study would show no significant difference. METHODS: We conducted 25 altitude chamber decompression exposure profiles. A total of 291 human subjects, 197 men and 94 women, underwent 961 exposures to simulated altitude for up to 8 h, using zero to 4 h of preoxygenation. Throughout the exposures, subjects breathed 100% oxygen, rested or performed mild or strenuous exercise, and were monitored for precordial venous gas emboli (VGE) and DCS symptoms. RESULTS: No significant differences in DCS incidence were observed between men (49.5%) and women (45.3%). However, VGE occurred at significantly higher rates among men than women under the same exposure conditions, 69.3% and 55.0% respectively. Women using hormonal contraception showed significantly greater susceptibility to DCS than those not using hormonal contraception during the latter two weeks of the menstrual cycle. Significantly higher DCS incidence was observed in the heaviest men, in women with the highest body fat, and in subjects with the highest body mass indices and lowest levels of fitness. CONCLUSION: No differences in altitude DCS incidence were observed between the sexes under our test conditions, although men developed VGE more often than women. Age and height showed no significant influence on DCS incidence, but persons of either sex with higher body mass index and lower physical fitness developed DCS more frequently.

NASA Discipline Environmental Health↗

Impact of lossy compression on diagnostic accuracy of radiographs for periapical lesions

OBJECTIVES: The purpose of this study was to evaluate the lossy Joint Photographic Experts Group compression for endodontic pretreatment digital radiographs. STUDY DESIGN: Fifty clinical charge-coupled device-based, digital radiographs depicting periapical areas were selected. Each image was compressed at 2, 4, 8, 16, 32, 48, and 64 compression ratios. One root per image was marked for examination. Images were randomized and viewed by four clinical observers under standardized viewing conditions. Each observer read the image set three times, with at least two weeks between each reading. Three pre-selected sites per image (mesial, distal, apical) were scored on a five-scale score confidence scale. A panel of three examiners scored the uncompressed images, with a consensus score for each site. The consensus score was used as the baseline for assessing the impact of lossy compression on the diagnostic values of images. The mean absolute error between consensus and observer scores was computed for each observer, site, and reading session. RESULTS: Balanced one-way analysis of variance for all observers indicated that for compression ratios 48 and 64, there was significant difference between mean absolute error of uncompressed and compressed images (P <.05). After converting the five-scale score to two-level diagnostic values, the diagnostic accuracy was strongly correlated (R (2) = 0.91) with the compression ratio. CONCLUSION: The results of this study suggest that high compression ratios can have a severe impact on the diagnostic quality of the digital radiographs for detection of periapical lesions.

NASA Discipline Space Human Factors↗

Evaluation of three portable samplers for monitoring airborne fungi

Airborne fungi were monitored at five sample sites with the Burkard portable, the RCS Plus, and the SAS Super 90 air samplers; the Andersen 2-stage impactor was used for comparison. All samplers were calibrated before being used simultaneously to collect 100-liter samples at each site. The Andersen and Burkard samplers retrieved equivalent volumes of airborne fungi; the SAS Super 90 and RCS Plus measurements did not differ from each other but were significantly lower than those obtained with the Andersen or Burkard samplers. Total fungal counts correlated linearly with Cladosporium and Penicillium counts. Alternaria species, although present at all sites, did not correlate with total count or with amounts of any other fungal genera. Sampler and location significantly influenced fungal counts, but no interactions between samplers and locations were found.

NASA Center JSC↗

Efficacy of anticoagulation in resolving left atrial and left atrial appendage thrombi: A transesophageal echocardiographic study

BACKGROUND: Transesophageal echocardiography (TEE) is the gold standard for evaluation of the left atrium and the left atrial appendage (LAA) for the presence of thrombi. Anticoagulation is conventionally used for patients with atrial fibrillation to prevent embolization of atrial thrombi. The mechanism of benefit and effectiveness of thrombi resolution with anticoagulation is not well defined. METHODS AND RESULTS: We used a TEE database of 9058 consecutive studies performed between January 1996 and November 1998 to identify all patients with thrombi reported in the left atrium and/or LAA. One hundred seventy-four patients with thrombi in the left atrial cavity (LAC) and LAA were identified (1.9% of transesophageal studies performed). The incidence of LAA thrombi was 6.6 times higher than LAC thrombi (151 vs 23, respectively). Almost all LAC thrombi were visualized on transthoracic echocardiography (90.5%). Mitral valve pathology was associated with LAC location of thrombi (P <.0001), whereas atrial fibrillation or flutter was present in most patients with LAA location of thrombi. Anticoagulation of 47 +/- 18 days was associated with thrombus resolution in 80.1% of the patients on follow-up TEE. Further anticoagulation resulted in limited additional benefit. CONCLUSIONS: LAC thrombi are rare and are usually associated with mitral valve pathology. Transthoracic echocardiography is effective in identifying these thrombi. LAA thrombi occur predominantly in patients with atrial fibrillation or flutter. Short-term anticoagulation achieves a high rate of resolution of LAA and LAC thrombi but does not obviate the need for follow-up TEE.

NASA Discipline Cardiopulmonary↗