Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Comparison of mega-voltage cone-beam computed tomography prostate localization with online ultrasound and fiducial markers methods

The online image-guided localization data from 696 ultrasound (United States), 598 mega-voltage cone-beam computed tomography (MV-CBCT), and 393 seed markers (SMs) couch alignments for patients undergoing intensity modulation radiotherapy of the prostate were analyzed. Daily US, MV-CBCT and SM images were acquired for 19, 17 and 12 patients, respectively, after each patient was immobilized in a vacuum cradle and setup to skin markers as the center of mass. The couch shifts applied in the lateral (left-right/LR), vertical (anterior-posterior/AP), and longitudinal (superior-inferior/SI) directions, along with the magnitude of the three-dimensional (3D) shift vector, were analyzed and compared for all three methods. The percentage of shifts larger than 5 mm in all directions was also compared. Clinical target volume-planning target volume (CTV-to-PTV) expansion margins were estimated based on the localization data with US, CB, and SM image guidance. Results show the US data have greater variability. Systematic and random shifts were -1.2{+-}6.8 mm (LR), -2.8{+-}5.1 mm (SI) and -1.0{+-}5.9 mm (AP) for US, 1.0{+-}3.9 mm (LR), -1.3{+-}2.5 mm (SI) and -0.3{+-}3.9 mm (AP) for CB, and -1.0{+-}3.4 mm (LR), 0.0{+-}3.4 mm (SI) and 0.5{+-}4.1 mm (AP) for SM. The mean 3D shift distance was larger using US (8.8{+-}6.2 mm) compared to CB and SM (5.3{+-}3.4 mm and 5.2{+-}3.7 mm, respectively). The percentage of US shifts larger than 5 mm were 34%, 31%, and 38% in the LR, SI, and AP directions, respectively, compared to 18%, 6%, and 16% for CB and 14%, 10%, and 20% for SM. MV-CBCT and SM localization data suggest a different distribution of prostate center-of-mass shifts with smaller variability, compared to US. The online MV-CBCT and SM image-guidance data show that for treatments that do not include daily prostate localization, one can use a CTV-to-PTV margin that is 4 mm smaller than the one suggested by US data, hence allowing more rectum and bladder sparing and potentially improving the therapeutic ratio.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Respiratory-Gated Helical Computed Tomography of Lung: Reproducibility of Small Volumes in an Ex Vivo Model

Purpose: Motion-adapted radiotherapy with gated irradiation or tracking of tumor positions requires dedicated imaging techniques such as four-dimensional (4D) helical computed tomography (CT) for patient selection and treatment planning. The objective was to evaluate the reproducibility of spatial information for small objects on respiratory-gated 4D helical CT using computer-assisted volumetry of lung nodules in a ventilated ex vivo system. Methods and Materials: Five porcine lungs were inflated inside a chest phantom and prepared with 55 artificial nodules (mean diameter, 8.4 mm {+-} 1.8). The lungs were respirated by a flexible diaphragm and scanned with 40-row detector CT (collimation, 24 x 1.2 mm; pitch, 0.1; rotation time, 1 s; slice thickness, 1.5 mm; increment, 0.8 mm). The 4D-CT scans acquired during respiration (eight per minute) and reconstructed at 0-100% inspiration and equivalent static scans were scored for motion-related artifacts (0 or absent to 3 or relevant). The reproducibility of nodule volumetry (three readers) was assessed using the variation coefficient (VC). Results: The mean volumes from the static and dynamic inspiratory scans were equal (364.9 and 360.8 mm{sup 3}, respectively, p = 0.24). The static and dynamic end-expiratory volumes were slightly greater (371.9 and 369.7 mm{sup 3}, respectively, p = 0.019). The VC for volumetry (static) was 3.1%, with no significant difference between 20 apical and 20 caudal nodules (2.6% and 3.5%, p = 0.25). In dynamic scans, the VC was greater (3.9%, p = 0.004; apical and caudal, 2.6% and 4.9%; p = 0.004), with a significant difference between static and dynamic in the 20 caudal nodules (3.5% and 4.9%, p = 0.015). This was consistent with greater motion-related artifacts and image noise at the diaphragm (p <0.05). The VC for interobserver variability was 0.6%. Conclusion: Residual motion-related artifacts had only minimal influence on volumetry of small solid lesions. This indicates a high reproducibility of spatial information for small objects in low pitch helical 4D-CT reconstructions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Computer Tomography System for the Soft X-ray Microscope at Ritsumeikan University

A synchrotron-based full-field imaging soft x-ray microscope was tuned appropriately to perform computer tomography. The contrast and focal depth of the optical system were evaluated by using a Fresnel zone plate as a test object of variable spatial frequency. A focal depth of 15 {mu}m was obtained at the spatial frequency of 4.3 {mu}m{sup -1} according to Rayleigh's criterion. As a first trial of three-dimensional observation using this system, the cerebral cortex of the brain of a mouse, trimmed to a columnar shape by focused ion beam milling, was studied using a wavelength of 1.87-nm.

43 PARTICLE ACCELERATORS↗

Evaluation of the setup margins for cone beam computed tomography–guided cranial radiosurgery: A phantom study

The aim of this study is to evaluate the setup margins from the clinical target volume (CTV) to planning target volume (PTV) for cranial stereotactic radiosurgery (SRS) treatments guided by cone beam computed tomography (CBCT). We designed an end-to-end (E2E) test using a skull phantom with an embedded 6mm tungsten ball (target). A noncoplanar plan was computed (E2E plan) to irradiate the target. The CBCT-guided positioning of the skull phantom on the linac was performed. Megavoltage portal images were acquired after 15 independent deliveries of the E2E plan. The displacement 2-dimensional (2D) vector between the centers of the square field and the ball target on each portal image was used to quantify the isocenter accuracy. Geometrical margins on each patient's direction (left-right or LR, anterior-posterior or AP, superior-inferior or SI) were calculated. Dosimetric validation of the margins was performed in 5 real SRS cases: 3-dimesional (3D) isocenter deviations were mimicked, and changes in CTV dose coverage and organs-at-risk (OARs) dosage were analyzed. The CTV-PTV margins of 1.1 mm in LR direction, and 0.7 mm in AP and SI directions were derived from the E2E tests. The dosimetric analysis revealed that a 1-mm uniform margin was sufficient to ensure the CTV dose coverage, without compromising the OAR dose tolerances. The effect of isocenter uncertainty has been estimated to be 1 mm in our CBCT-guided SRS approach.

61 RADIATION PROTECTION AND DOSIMETRY↗

Artifacts in Conventional Computed Tomography (CT) and Free Breathing Four-Dimensional CT Induce Uncertainty in Gross Tumor Volume Determination

Purpose: Artifacts impacting the imaged tumor volume can be seen in conventional three-dimensional CT (3DCT) scans for planning of lung cancer radiotherapy but can be reduced with the use of respiration-correlated imaging, i.e., 4DCT or breathhold CT (BHCT) scans. The aim of this study was to compare delineated gross tumor volume (GTV) sizes in 3DCT, 4DCT, and BHCT scans of patients with lung tumors. Methods and Materials: A total of 36 patients with 46 tumors referred for stereotactic radiotherapy of lung tumors were included. All patients underwent positron emission tomography (PET)/CT, 4DCT, and BHCT scans. GTVs in all CT scans of individual patients were delineated during one session by a single physician to minimize systematic delineation uncertainty. The GTV size from the BHCT was considered the closest to true tumor volume and was chosen as the reference. The reference GTV size was compared to GTV sizes in 3DCT, at midventilation (MidV), at end-inspiration (Insp), and at end-expiration (Exp) bins from the 4DCT scan. Results: The median BHCT GTV size was 4.9 cm{sup 3} (0.1-53.3 cm{sup 3}). Median deviation between 3DCT and BHCT GTV size was 0.3 cm{sup 3} (-3.3 to 30.0 cm{sup 3}), between MidV and BHCT size was 0.2 cm{sup 3} (-5.7 to 19.7 cm{sup 3}), between Insp and BHCT size was 0.3 cm{sup 3} (-4.7 to 24.8 cm{sup 3}), and between Exp and BHCT size was 0.3 cm{sup 3} (-4.8 to 25.5 cm{sup 3}). The 3DCT, MidV, Insp, and Exp median GTV sizes were all significantly larger than the BHCT median GTV size. Conclusions: In the present study, the choice of CT method significantly influenced the delineated GTV size, on average, leading to an increase in GTV size compared to the reference BHCT. The uncertainty caused by artifacts is estimated to be in the same magnitude as delineation uncertainty and should be considered in the design of margins for radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multihead Attention U‐Net for Magnetic Particle Imaging–Computed Tomography Image Segmentation

Magnetic particle imaging (MPI) is an emerging noninvasive molecular imaging modality with high sensitivity and specificity, exceptional linear quantitative ability, and potential for successful applications in clinical settings. Computed tomography (CT) is typically combined with the MPI image to obtain more anatomical information. Herein, a deep learning‐based approach for MPI‐CT image segmentation is presented. The dataset utilized in training the proposed deep learning model is obtained from a transgenic mouse model of breast cancer following administration of indocyanine green (ICG)‐conjugated superparamagnetic iron oxide nanoworms (NWs‐ICG) as the tracer. The NWs‐ICG particles progressively accumulate in tumors due to the enhanced permeability and retention (EPR) effect. The proposed deep learning model exploits the advantages of the multihead attention mechanism and the U‐Net model to perform segmentation on the MPI‐CT images, showing superb results. In addition, the model is characterized with a different number of attention heads to explore the optimal number for our custom MPI‐CT dataset.

Juhong, Aniwat↗

Daily Image Guidance With Cone-Beam Computed Tomography for Head-and-Neck Cancer Intensity-Modulated Radiotherapy: A Prospective Study

Purpose: To report on a prospective clinical trial of the use of daily kilovoltage cone-beam computed tomography (CBCT) to evaluate the interfraction and residual error motion of patients undergoing intensity-modulated radiotherapy for head-and-neck cancer. Methods and Materials: Patients were treated with intensity-modulated radiotherapy with an Elekta linear accelerator using a mounted CBCT scanner. CBCT was performed before every treatment, and translational (but not rotational) corrections were performed. At least once per week, a CBCT scan was obtained after intensity-modulated radiotherapy. Variations were measured in the medial-lateral, superoinferior, and anteroposterior dimensions, as well as in the rotation around these axes. Results: A total of 28 consecutive patients (1,013 CBCT scans) were studied. The average interfraction shift was 1.4 +- 1.4, 1.7 +- 1.9, and 1.8 +- 2.1 mm in the medial-lateral, superoinferior, and anteroposterior dimensions, respectively. The corresponding average residual error shifts were 0.7 +- 0.8, 0.9 +- 0.9, and 0.9 +- 0.9 mm. These data indicate that in the absence of daily CBCT image-guided radiotherapy, a clinical target volume to planning target volume margin of 3.9, 4.1, and 4.9 mm is needed in the medial-lateral, superoinferior, and anteroposterior dimensions, respectively. With daily CBCT, corresponding margins of 1.6, 2.5, and 1.9 mm should be acceptable. Subgroup analyses showed that larynx cancers and/or intratreatment weight loss indicate a need for slightly larger clinical target volume to planning target volume margins. Conclusion: The results of our study have shown that image-guided radiotherapy using CBCT for head-and-neck cancer is effective. These data suggest it allows a reduction in the clinical target volume to planning target volume margins by about 50%, which could facilitate future studies of dose escalation and/or improved toxicity reduction. Caution is particularly warranted for cases in which the targets are mobile (e.g., the tongue).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Four-Dimensional Computed Tomography Analysis of Multiorgan Abdominal Motion

Purpose: To characterize and quantify multiorgan respiration-induced motion in the abdomen in liver and pancreatic cancer patients. Methods and Materials: Four-dimensional computed tomography scans were acquired for 18 patients treated for abdominal tumors. Contours of multiple abdominal organs were drawn by the radiation oncologist at one respiratory phase; these contours were propagated to other respiratory phases by deformable registration. Three-dimensional organ models were generated from the resulting contours at each phase. Motions of the bounding box and center of mass were extracted and analyzed for the clinical target volume and organs at risk. Results: On average, the center of mass motion for liver clinical target volumes was 9.7 mm (SD 5 mm) in the superior-inferior direction, with a range of 3 to 18 mm; for pancreatic tumors, the average was 5 mm (SD 1 mm) m with a range of 3 to 7 mm. Abdominal organs move in unison, but with varying amplitudes. Gating near exhale (T40-T60) reduces the range of motion by a factor of {approx}10. Conclusion: We have used deformable registration to calculate the trajectories of abdominal organs in four dimensions, based on center of mass and bounding box motion metrics. Our results are compared with previously reported studies. Possible reasons for differences are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dual-Energy Micro-Computed Tomography Imaging of Radiation-Induced Vascular Changes in Primary Mouse Sarcomas

Purpose: To evaluate the effects of radiation therapy on primary tumor vasculature using dual-energy (DE) micro-computed tomography (micro-CT). Methods and Materials: Primary sarcomas were generated with mutant Kras and p53. Unirradiated tumors were compared with tumors irradiated with 20 Gy. A liposomal-iodinated contrast agent was administered 1 day after treatment, and mice were imaged immediately after injection (day 1) and 3 days later (day 4) with DE micro-CT. CT-derived tumor sizes were used to assess tumor growth. After DE decomposition, iodine maps were used to assess tumor fractional blood volume (FBV) at day 1 and tumor vascular permeability at day 4. For comparison, tumor vascularity and vascular permeability were also evaluated histologically by use of CD31 immunofluorescence and fluorescently-labeled dextrans. Results: Radiation treatment significantly decreased tumor growth from day 1 to day 4 (P<.05). There was a positive correlation between CT measurement of tumor FBV on day 1 and extravasated iodine on day 4 with microvascular density (MVD) on day 4 (R{sup 2}=0.53) and dextran accumulation (R{sup 2}=0.63) on day 4, respectively. Despite no change in MVD measured by histology, tumor FBV significantly increased after irradiation as measured by DE micro-CT (0.070 vs 0.091, P<.05). Both dextran and liposomal-iodine accumulation in tumors increased significantly after irradiation, with dextran fractional area increasing 5.2-fold and liposomal-iodine concentration increasing 4.0-fold. Conclusions: DE micro-CT is an effective tool for noninvasive assessment of vascular changes in primary tumors. Tumor blood volume and vascular permeability increased after a single therapeutic dose of radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of Diffusion Profiles in Altered Wellbore Cement Using X-ray Computed Tomography Methods

The development of accurate, predictive models for use in determining wellbore integrity requires detailed information about the chemical and mechanical changes occurring in hardened Portland cements. X-ray computed tomography (XRCT) provides a method that can nondestructively probe these changes in three dimensions. Here, we describe a method for extracting subvoxel mineralogical and chemical information from synchrotron XRCT images by combining advanced image segmentation with geochemical models of cement alteration. The method relies on determining “effective linear activity coefficients” (ELAC) for the white light source to generate calibration curves that relate the image grayscales to material composition. The resulting data set supports the modeling of cement alteration by CO 2 -rich brine with discrete increases in calcium concentration at reaction boundaries. The results of these XRCT analyses can be used to further improve coupled geochemical and mechanical models of cement alteration in the wellbore environment.

15 GEOTHERMAL ENERGY↗

Use of Constrained Gamma Emission Computed Tomography to Evaluate Fission Product Distributions in High-Temperature Materials from a TRISO Fuel Irradiation

An image reconstruction technique was developed to overcome problems with earlier methods of gamma emission computed tomography of graphite rings surrounding the AGR-3/4 TRISO fission product transport experiment. The profiles obtained from the tomography are compared with sampling done via radially resolved destructive sampling techniques. Generally, there is good agreement between profiles measured via destructive sampling of the rings and the tomographic profiles, though at low signal strengths, the tomographic profiles appear elevated.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Core Characterization: Computer Tomography, Geochemical, and Core Petrophysical Workflows for Emerging Critical Mineral Plays

The National Energy Technology Laboratory’s geoimaging lab in Morgantown, WV has been performing core characterization using multi-resolution Computed Tomography (CT) imaging and multisensor corelogger which allows for cm-resolution elemental and petrophysical measurements along whole core. This workflow has historically been used in unconventional gas plays and potential carbon storage locations. This rapid core characterization leads itself well as a first phase process in CM/REE evaluation efforts allowing for high-resolution, non-destructive investigation of elemental concentration using X-Ray Fluorescence and examination of core features through CT imaging.

Paronish, Thomas J.↗

Computer tomography imaging of fast plasmachemical processes

Results are presented from experimental studies of the interaction of a high-enthalpy methane plasma bunch with gaseous methane in a plasmachemical reactor. The interaction of the plasma flow with the rest gas was visualized by using streak imaging and computer tomography. Tomography was applied for the first time to reconstruct the spatial structure and dynamics of the reagent zones in the microsecond range by the maximum entropy method. The reagent zones were identified from the emission of atomic hydrogen (the H{sub {alpha}} line) and molecular carbon (the Swan bands). The spatiotemporal behavior of the reagent zones was determined, and their relation to the shock-wave structure of the plasma flow was examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-CD-206-12: Image-Based Motion Estimation for Plaque Visualization in Coronary Computed Tomography Angiography

Purpose: Visualization and quantification of coronary artery calcification and atherosclerotic plaque benefits from coronary artery motion (CAM) artifact elimination. This work applies a rigid linear motion model to a Volume of Interest (VoI) for estimating motion estimation and compensation of image degradation in Coronary Computed Tomography Angiography (CCTA). Methods: In both simulation and testbench experiments, translational CAM was generated by displacement of the imaging object (i.e. simulated coronary artery and explanted human heart) by ∼8 mm, approximating the motion of a main coronary branch. Rotation was assumed to be negligible. A motion degraded region containing a calcification was selected as the VoI. Local residual motion was assumed to be rigid and linear over the acquisition window, simulating motion observed during diastasis. The (negative) magnitude of the image gradient of the reconstructed VoI was chosen as the motion estimation objective and was minimized with Covariance Matrix Adaptation Evolution Strategy (CMAES). Results: Reconstruction incorporated the estimated CAM yielded signification recovery of fine calcification structures as well as reduced motion artifacts within the selected local region. The compensated reconstruction was further evaluated using two image similarity metrics, the structural similarity index (SSIM) and Root Mean Square Error (RMSE). At the calcification site, the compensated data achieved a 3% increase in SSIM and a 91.2% decrease in RMSE in comparison with the uncompensated reconstruction. Conclusion: Results demonstrate the feasibility of our image-based motion estimation method exploiting a local rigid linear model for CAM compensation. The method shows promising preliminary results for the application of such estimation in CCTA. Further work will involve motion estimation of complex motion corrupted patient data acquired from clinical CT scanner.

60 APPLIED LIFE SCIENCES↗

Implications of Respiratory Motion as Measured by Four-Dimensional Computed Tomography for Radiation Treatment Planning of Esophageal Cancer

Purpose: To evaluate the respiratory motion of primary esophageal cancers and pathologic celiac-region lymph nodes using time-resolved four-dimensional computed tomography (4D CT). Methods and Materials: Respiration-synchronized 4D CT scans were obtained to quantify the motion of primary tumors located in the proximal, mid-, or distal thoracic esophagus, as well as any involved celiac-region lymph nodes. Respiratory motion was measured in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions and was analyzed for correlation with anatomic location. Recommended margin expansions were determined for both primary and nodal targets. Results: Thirty patients underwent 4D CT scans at Massachusetts General Hospital for planned curative treatment of esophageal cancer. Measurements of respiratory tumor motion were obtained for 1 proximal, 4 mid-, and 25 distal esophageal tumors, as well as 12 involved celiac-region lymph nodes. The mean (SD) peak-to-peak displacements of all primary tumors in the SI, AP, and LR dimensions were 0.80 (0.45) cm, 0.28 (0.20) cm, and 0.22 (0.23) cm, respectively. Distal tumors were found to have significantly greater SI and AP motion than proximal or mid-esophageal tumors. The mean (SD) SI, AP, and LR peak-to-peak displacements of the celiac-region lymph nodes were 0.92 (0.56) cm, 0.46 (0.27) cm, and 0.19 (0.26) cm, respectively. Conclusions: Margins of 1.5 cm SI, 0.75 cm AP, and 0.75 cm LR would account for respiratory tumor motion of >95% of esophageal primary tumors in the dataset. All celiac-region lymph nodes would be adequately covered with SI, AP, and LR margins of 2.25 cm, 1.0 cm, and 0.75 cm, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Immobilization on Intrafraction Motion for Spine Stereotactic Body Radiotherapy Using Cone Beam Computed Tomography

Purpose: Spine stereotactic body radiotherapy (SBRT) involves tight planning margins and steep dose gradients to the surrounding organs at risk (OAR). This study aimed to assess intrafraction motion using cone beam computed tomography (CBCT) for spine SBRT patients treated using three immobilization devices. Methods and Materials: Setup accuracy using CBCT was retrospectively analyzed for 102 treated spinal metastases in 84 patients. Thoracic and lumbar spine patients were immobilized with either an evacuated cushion (EC, n = 24) or a semirigid vacuum body fixation (BF, n = 60). For cases treated at cervical/upper thoracic (thoracic [T]1-T3) vertebrae, a thermoplastic S-frame (SF) mask (n = 18) was used. Patient setup was corrected by using bony anatomy image registration and couch translations only (no rotation corrections) with shifts confirmed on verification CBCTs. Repeat imaging was performed mid- and post-treatment. Patient translational and rotational positioning data were recorded to calculate means, standard deviations (SD), and corresponding margins {+-} 2 SD for residual setup errors and intrafraction motion. Results: A total of 355 localizations, 333 verifications, and 248 mid- and 280 post-treatment CBCTs were analyzed. Residual translations and rotations after couch corrections (verification scans) were similar for all immobilization systems, with SDs of 0.6 to 0.9 mm in any direction and 0.9 Degree-Sign to 1.6 Degree-Sign , respectively. Margins to encompass residual setup errors after couch corrections were within 2 mm. Including intrafraction motion, as measured on post-treatment CBCTs, SDs for total setup error in the left-right, cranial-caudal, and anterior-posterior directions were 1.3, 1.2, and 1.0 mm for EC; 0.9, 0.7, and 0.9 mm for BF; and 1.3, 0.9, and 1.1 mm for SF, respectively. The calculated margins required to encompass total setup error increased to 3 mm for EC and SF and remained within 2 mm for BF. Conclusion: Following image guidance, residual setup errors for spine SBRT were similar across three immobilization systems. The BF device resulted in the least amount of intrafraction motion, and based on this device, we justify a 2-mm margin for the planning OAR and target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low tube voltage dual source computed tomography to reduce contrast media doses in adult abdomen examinations: A phantom study

Purpose: To evaluate the potential of low tube voltage dual source (DS) single energy (SE) and dual energy (DE) computed tomography (CT) to reduce contrast media (CM) dose in adult abdominal examinations of various sizes while maintaining soft tissue and iodine contrast-to-noise ratio (CNR). Methods: Four abdominal phantoms simulating a body mass index of 16 to 35 kg/m{sup 2} with four inserted syringes of 0, 2, 4, and 8 mgI/ml CM were scanned using a 64-slice DS-CT scanner. Six imaging protocols were used; one single source (SS) reference protocol (120 kV, 180 reference mAs), four low kV SE protocols (70 and 80 kV using both SS and DS), and one DE protocol at 80/140 kV. Potential CM reduction with unchanged CNRs relative to the 120 kV protocol was calculated along with the corresponding increase in radiation dose. Results: The potential contrast media reductions were determined to be approximately 53% for DS 70 kV, 51% for SS 70 kV, 44% for DS 80 kV, 40% for SS 80 kV, and 20% for DE (all differences were significant, P < 0.05). Constant CNR could be achieved by using DS 70 kV for small to medium phantom sizes (16–26 kg/m{sup 2}) and for all sizes (16–35 kg/m{sup 2}) when using DS 80 kV and DE. Corresponding radiation doses increased by 60%–107%, 23%–83%, and 6%–12%, respectively. Conclusions: DS single energy CT can be used to reduce CM dose by 44%–53% with maintained CNR in adult abdominal examinations at the cost of an increased radiation dose. DS dual-energy CT allows reduction of CM dose by 20% at similar radiation dose as compared to a standard 120 kV single source.

60 APPLIED LIFE SCIENCES↗