Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building energy efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Urban Combined Heat and Power with Integrated Renewables and Energy Storage

District energy systems efficiently provide thermal energy to multiple buildings and facilities through a network of shared infrastructure. Frequently, district energy systems are centered around combined heat and power (CHP) plants that generate electricity as well as heating and cooling to the local buildings. By providing both electricity and thermal energy from a single fuel source and central location, these systems use less fuel, decrease energy and operational costs, and reduce the need for heating and cooling equipment in individual buildings.

EMS, CHP, GWU↗

A Simplified Tool for Rapidly Deploying Feasibility Analytics for the Non-Technical User

District energy systems efficiently provide thermal energy to multiple buildings and facilities through a network of shared infrastructure. Frequently, district energy systems are centered around combined heat and power (CHP) plants that generate electricity, as well as heating and cooling, to the local buildings. By providing both electricity and thermal energy from a single fuel source and central location, these systems use less fuel, decrease energy and operational costs, and reduce the need for heating and cooling equipment in individual buildings.

CHP, RCDC↗

Flexible Natural Gas/Hydrogen Combined Heat and Power System

District energy systems efficiently provide thermal energy to multiple buildings and facilities through a network of shared infrastructure. Frequently, district energy systems are centered around combined heat and power (CHP) plants that generate electricity as well as heating and cooling to the local buildings. By providing both electricity and thermal energy from a single fuel source and central location, these systems use less fuel, decrease energy and operational costs, and reduce the need for heating and cooling equipment in individual buildings.

CHP, ID/3D↗

Decarbonizing the Building Sector: A Human-Centered Study Focused on Small/Light Commercial Building Energy Equity

Decarbonization of the building sector is no small feat; buildings account for 40% of primary energy consumption, and fossil-fuel combustion in buildings leads to roughly 30% of total greenhouse gas emissions. Energy efficiency, electrification and smart technologies are fundamental strategies to reduce consumption and shift away from fossil-fuel use in buildings. This energy transition carries significant societal risks unless the shift is carried out with equity and justice as a top priority. Low-income, vulnerable and communities of color have higher energy burdens compared to affluent populations. Furthermore, systemic racism and historic exclusionary policies have resulted in increased risks (environmental, climatic, economic, and social) to low-income and communities of color, and underserved communities often do not have financial resources for, or access to, advanced building technologies. The U.S. Department of Energy is funding research to characterize and develop solutions to the challenges of equity and justice that complicate the ability of communities to contribute to goals for decarbonization. Our project has a specific focus on small commercial buildings and the businesses that occupy them. Significantly less is known about the burdens and risks these businesses experience or the challenges they face in pursuing decarbonization, or how those are affected by income and race, in comparison to research on energy equity and justice for diverse households. The project team includes the Pacific Northwest National Laboratory, Arizona State University and Clark Atlanta University. Researchers are conducting semi-structured interviews with small business owners in underserved communities in Phoenix and Atlanta, followed by a survey distributed to the larger community to learn more about the equity and justice issues that communities with different racial, economic, and cultural backgrounds face. Results will help inform an actionable and replicable framework for engaging small commercial building owners/operators to catalyze the reduction of energy burdens and increase equity.

Antonopoulos, Chrissi A.↗

Integration of Ag-CBRAM crossbars and Mott ReLU neurons for efficient implementation of deep neural networks in hardware

In-memory computing with emerging non-volatile memory devices (eNVMs) has shown promising results in accelerating matrix-vector multiplications. However, activation function calculations are still being implemented with general processors or large and complex neuron peripheral circuits. Here, we present the integration of Ag-based conductive bridge random access memory (Ag-CBRAM) crossbar arrays with Mott rectified linear unit (ReLU) activation neurons for scalable, energy and area-efficient hardware (HW) implementation of deep neural networks. We develop Ag-CBRAM devices that can achieve a high ON/OFF ratio and multi-level programmability. Compact and energy-efficient Mott ReLU neuron devices implementing ReLU activation function are directly connected to the columns of Ag-CBRAM crossbars to compute the output from the weighted sum current. We implement convolution filters and activations for VGG-16 using our integrated HW and demonstrate the successful generation of feature maps for CIFAR-10 images in HW. Our approach paves a new way toward building a highly compact and energy-efficient eNVMs-based in-memory computing system.

Mott insulators↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy dataset of Frontier supercomputer for waste heat recovery

The Hewlett Packard Enterprise–Cray EX Frontier is the world’s first and fastest exascale supercomputer, hosted at the Oak Ridge Leadership Computing Facility in Tennessee, United States. Frontier is a significant electricity consumer, drawing 8–30 MW; this massive energy demand produces significant waste heat, requiring extensive cooling measures. Although harnessing this waste heat for campus heating is a sustainability goal at Oak Ridge National Laboratory (ORNL), the 30 °C–38 °C waste heat temperature poses compatibility issues with standard HVAC systems. Heat pump systems, prevalent in residential settings and some industries, can efficiently upgrade low-quality heat to usable energy for buildings. Thus, heat pump technology powered by renewable electricity offers an efficient, cost-effective solution for substantial waste heat recovery. However, a major challenge is the absence of benchmark data on high-performance computing (HPC) heat generation and waste heat profiles. This paper reports power demand and waste heat measurements from an ORNL HPC data centre, aiming to guide future research on optimizing waste heat recovery in large-scale data centres, especially those of HPC calibre.

97 MATHEMATICS AND COMPUTING↗

Impacts of Electric Space Heating in Multifamily Apartments in Juneau, Alaska [Slides]

The study objective was to understand the change in electrical consumption and cost after the addition of a ductless mini-split air-source heat pump (ASHP) across rental apartments heated by electrical resistance heating systems in multifamily buildings in Juneau, Alaska. Alaska Electric Light and Power Company (AELP), the utility in Juneau, Alaska, funded installation of 19 heat pumps across four buildings. Using electrical meter interval data, including the total apartment consumption and submeter data for each heating appliance (electric resistance baseboard and heat pump), the National Laboratory of the Rockies (NLR) calculated energy use metrics before and after heat pump installation and visualized results. Through this research, NLR compares electrical use (total and specific to heating appliances), adjusted for weather and apartment size, and electrical demand in the year before and after installation of an ASHP across study units. The results will inform the utility and residents of documented energy and cost savings from transitioning building heating systems to a higher-efficiency electricity-based appliance, deliver a basis for building energy modeling across other multifamily housing dwellings, and enable estimates of potential electricity savings to AELP grid under widespread adoption scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GT Flex: A Coordinated Multi-Building Pilot Study

Buildings are a significant and untapped resource for providing utility electric grid services. Recent studies have estimated that buildings could reduce the peak demand on the electric grid in the U.S. by almost 25% through effective combinations of energy efficiency (EE) measures and load flexibility strategies (Langevin et al. 2021). The U.S. Department of Energy (DOE) has established a goal to triple energy efficiency and demand flexibility in both residential and commercial sections by 2030 compared to 2020 levels (Satchwell et al. 2021). Such findings place buildings alongside electric vehicles, photovoltaics, electric batteries, and other distributed energy resources (DERs) as primary technologies needed for supporting high renewable energy generation grids. Coordinating and optimizing multiple buildings and other DERs is more beneficial and valuable when compared with individual buildings and DERs operating as siloed resources, uncoordinated with others (Olgyay et al. 2020). A pilot study at the Georgia Institute of Technology (GIT) was conducted to evaluate value propositions of a multi-building scale project seeking carbon reduction, energy efficiency and grid-interactive capabilities, by demonstrating the means by which stakeholders can determine the technical and financial merits of grid-interactivity and energy efficiency technologies coordinated across multiple assets. The study focused on analyzing technical feasibility of deploying thermal load flexibility strategies at the multi-building scale, coordinated to not exceed existing infrastructure constraints at the pilot site. Results show that campus can provide 3-3.5 MW of potential load shed over a 4-hour event window through coordinated dispatch of thermal cooling load flexibility without exceeding existing infrastructure capacities. Under future high renewable scenarios, this thermal flexibility resource is also valuable when coordinated to reduce curtailment of intermittent renewables. Economic analyses were performed to effectively communicate various value propositions of grid-interactive and efficient building (GEB) thermal flexibility strategies. Load flexibility presents a financial value proposition to the campus today. By conducting rationalized, coordinated dispatch in response to real time price (RTP) fluctuations, the campus can benefit materially from daily price arbitrage. The RTP signal acts as an aggregating mechanism between the utility and customer to call on demand flexibility resources, with a large portion of the benefit deriving from a relatively small number of days. Realizing and maximizing this benefit with thermal load flexibility requires careful attention to the timing of pricing signals and parameterization of dispatch to overcome efficiency penalties. Grid value and signals are expected to evolve over time, and thermal load flexibility shows potential to adapt dispatch logic to support intermittent renewable generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EUI Benchmarks for Net-Zero Energy Buildings in India

In our study we present EUI benchmarks for NZEBs for six building types across residential and non-residential typologies and for India's five climate zones. This approach is similar to the simulation-based benchmarks used by the B3 program in Minnesota, the Cal-Arch methodology in California, and the US Solar Decathlon approach, which combine simulations with actual building data. Of the six building types we explore one in detail with a range of operation scenarios, specifically narrowing down the EUI benchmarks for mixed-mode building operation and for variable temperature set-points as prescribed in the National Building Code of India.The contribution of this work is to provide rigorous end-use level EUI benchmarks for six building types, and to describe a method for simulation-based EUI benchmarks for mixed-mode operation with variable setpoints to highlight the difference between the standard approach used for the five building types and the On-Site Construction Worker Housing which additionally has the mixed-mode variable setpoint approach.On-Site Construction Worker Housings are typically poorly constructed temporary structures, without adequate thermal comfort, It is critical to provide adequate thermal comfort to protect people from the warming effects of climate change, and to discover super efficient and cost-effective ways to do so.The methodology used for the On-Site Construction Worker Housing (CWH) results in an 80% acceptability according to the India Model for Adaptive Comfort in the National Building Code of India. EUIs of all six buildings are 60% lower than the minimum compliance with India's Energy Conservation Building Codes, providing benchmarks for efficiency levels. The end-use level EUI benchmarks are now provided to over 1800 Solar Decathlon India participants so that they can compare the performance of their NZEB designs.In particular, the CWH results provide an insight into the importance of the mixed-mode operation with variable temperature set-points. The results from the simulation study show that for an NZEB target, the EUI with standard thermal comfort model and without mixed operation is 58.26 kWh/m2*year, while that with the variable set-points of the adaptive model with mixed mode operation is 24.23 kWh/m2*year. This is a 58% reduction in EUI. Given that many building types including residential, and non-residential operate in mixed mode, it is important to take this work further to develop mixed-mode operation NZEB benchmarks so that the carbon intensity of these buildings could be lower than the standard thermal comfort model approach.

benchmarking↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Usage of NASA's Near Real-Time Solar and Meteorological Data for Monitoring Building Energy Systems Using RETScreen International's Performance Analysis Module

This paper describes building energy system production and usage monitoring using examples from the new RETScreen Performance Analysis Module, called RETScreen Plus. The module uses daily meteorological (i.e., temperature, humidity, wind and solar, etc.) over a period of time to derive a building system function that is used to monitor building performance. The new module can also be used to target building systems with enhanced technologies. If daily ambient meteorological and solar information are not available, these are obtained over the internet from NASA's near-term data products that provide global meteorological and solar information within 3-6 days of real-time. The accuracy of the NASA data are shown to be excellent for this purpose enabling RETScreen Plus to easily detect changes in the system function and efficiency. This is shown by several examples, one of which is a new building at the NASA Langley Research Center that uses solar panels to provide electrical energy for building energy and excess energy for other uses. The system shows steady performance within the uncertainties of the input data. The other example involves assessing the reduction in energy usage by an apartment building in Sweden before and after an energy efficiency upgrade. In this case, savings up to 16% are shown.

Paul W Stackhouse, Jr.↗

Reinforcement Learning Control for Buildings Co-Optimizing Energy, Comfort, and Indoor Air Quality: An Annual Assessment

Efficient control of Heating, Ventilation, and Air Conditioning (HVAC) systems is crucial for optimizing energy use and maintaining indoor comfort in buildings. Traditional control methods, such as PID control, cannot handle energy use trade-offs among multiple components in the building energy system at a supervisory level. Reinforcement learning (RL) presents a promising solution, offering adaptive and data-driven control strategies that optimize performance over time. However, RL also faces several challenges, including the conflicts encountered in co-optimizing energy savings, occupant comfort, and indoor air quality, and the requirement for extensive interactions with the environment in training. We proposed a flexible simulation platform that integrates a hybrid model for RL training and designed an RL agent to control the entire central HVAC system, focusing on co-optimizing energy consumption, thermal comfort, and indoor air quality ($\text{CO}_{2}$ and PM2.5 concentrations). Finally, we evaluated the RL agent's performance over an annual cycle. Our findings indicate that the RL agent can effectively manage the HVAC system with 14.7 % energy savings annually and balance multiple objectives, which demonstrates significant potential for improving HVAC system control and sustainability in buildings.

Guo, Fangzhou↗

Aniak Energy Efficiency Retrofit Project

The Native Village of Aniak (NVA) is a remote Yup’ik community in western Alaska. NVA is proposing to install energy efficiency measures in the Tribal Office, Community Center, Association of Village Council Presidents (AVCP) Office, and Duplex. The goal of the project is to reduce the overall energy use of the NVA by implementing energy efficiency measures in four high-use tribal buildings. This project expects to have the following outcomes: projected annual energy savings of approximately $24,238; projected annual reduction in fuel oil of roughly 1,802 gallons and electricity of around 24,537 kWh; and annual reduction in carbon dioxide emissions of approximately 84,594 pounds/year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ventilating Air-Conditioner

Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

Dinh, Khanh↗