Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “builders”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

DOE Zero Energy Ready Home Case Study: Palo Duro Homes — Palo Duro Homes, Albuquerque, NM

This builder was honored for Most DOE Zero Energy Ready Homes Built in the 2014 Housing Innovation Awards. By July 2014, Palo Duro had completed 152 homes since the program began in 2013 (under the original program title DOE Challenge Home), all of them certified to the stringent efficiency requirements of DOE’s Zero Energy Ready Home program.

2014 housing innovation awards↗

DOE Zero Energy Ready Home Case Study: TC Legend Homes — Cedarwood, Bellingham, WA

This house was the Grand Winner in the Affordable Builder category of the 2014 Housing Innovation Awards, and has 6-inch SIP walls, a 10-inch structural insulated panel roof, and insulating concrete forms foundation walls with R-20 high-density rigid EPS foam under the slab.A single ductless heat pump heats and cools the home, which also gets passive solar heating from south-facing triple-pane windows that heat a concrete slab floor plus a connected greenhouse.

2014 housing innovation awards↗

Technology Solutions Case Study: Initial and Long-Term MOvement of Cladding Installed Over Exterior Rigid Insulation

Changes in the International Energy Conservation Code (IECC) from 2009 to 2012 have resulted in the use of exterior rigid insulation becoming part of the prescriptive code requirements. With more jurisdictions adopting the 2012 IECC, builders will be required to incorporate exterior insulation in the construction of their exterior wall assemblies. For thick layers of exterior insulation (levels greater than 1.5 inches), the use of wood of furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location. However, there has been resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved and potential creep effects of the assembly under the sustained dead load of a cladding. This research conducted by Building Science Corporation evaluated the system mechanics and long-term performance of this technique.

BSC↗

Technology Solutions Case Study: Guidance on Taped Insulating Sheathing Drainage Planes

The energy efficiency-based financial benefits of adding exterior insulation are well accepted by the building industry, and using exterior insulation as the drainage plane is the next logical step. This case study focuses on the field implementation of taped board insulation as the drainage plane in both new and retrofit residential applications, and provides information and recommendations for insulation contractors, general contractors, builders, remodelers, mechanical contractors, and homeowners. The order of work completed during home construction and retrofit improvements is important. Health and safety issues must be addressed first and are more important than durability issues, and durability issues are more important than saving energy. Three significant items are required to make taped insulating sheathing a simple, long term, and durable drainage plane: first, horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists, use superior materials; and, frequent installation inspection and regular trade training are required to maintain proper installation.

BSC↗

Technology Solutions Case Study: Field Testing of Compartmentalization Methods for Multifamily Construction

Fire-resistance rated (or area separation) wall assemblies present a great difficulty in air sealing/compartmentalization, particularly in townhouse construction. To address this challenge, Building Science Corporation partnered with builder K. Hovnanian Homes to determine whether taping exterior sheathing details improves air sealing in townhouse and multifamily construction, and to better understand air leakage pathways.

air leakage↗

Technology Solutions Case Study: Monitoring of Double Stud Wall Moisture Conditions in the Northeast, Devens, Massachusetts

Double stud walls have a higher risk of interior-sourced condensation moisture damage when compared with high-R approaches using exterior insulating sheathing. In this project, Building Science Corporation monitored moisture conditions in double-stud walls from 2011 through 2014 at a new production house located in Devens, Massachusetts. The builder, Transformations, Inc., has been using double-stud walls insulated with 12 in. of open cell polyurethane spray foam (ocSPF); however, the company has been considering a change to netted and blown cellulose insulation for cost reasons. Cellulose is a common choice for double-stud walls because of its lower cost (in most markets). However, cellulose is an air-permeable insulation, unlike spray foams, which increases interior moisture risks. The team compared three double-stud assemblies: 12 in. of ocSPF, 12 in. of cellulose, and 5-½ in. of ocSPF at the exterior of a double-stud wall (to approximate conventional 2 × 6 wall construction and insulation levels, acting as a control wall). These assemblies were repeated on the north and south orientations, for a total of six assemblies.

BSC↗

New Whole-House Solutions Case Study: Singer Village - A Cold Climate Zero Energy Ready Home, Derby, Connecticut

After progressively incorporating ENERGY STAR for Homes Versions 1, 2, and 3 into its standard practices over the years, builder Brookside Development was seeking to build an even more sustainable product that would further increase energy efficiency, while also addressing indoor air quality, water conservation, renewable-ready, and resiliency. These objectives align with the framework of the U.S. Department of Energy Zero Energy Ready Home program, which builds upon the comprehensive building science requirements of ENERGY STAR for Homes Version 3 and proven Building America innovations and best practices. To meet this goal, Consortium for Advanced Residential Buildings partnered with Brookside Development to design and construct the first zero energy ready home in a development of seven new homes on the old Singer Estate in Derby, Connecticut.

AIR SEALING CEILING PLANE↗

New Whole-House Solutions Case Study: EcoVillage: A Net Zero Energy Ready Community, Ithaca, New York

The Consortium for Advanced Residential Buildings is working with the EcoVillage co-housing community and builder AquaZephyr in Ithaca, New York, on their third neighborhood called the Third Residential EcoVillage Experience (TREE). This community-scale project consists of 40 housing units—15 apartments, and 25 single family residences that range in size from 1,250 ft2–1,664 ft2 and cost from $80,000 to $235,000. The community is pursing DOE Zero Energy Ready Home (ZERH), US Green Building Council Leadership in Energy and Environmental Design (LEED) Gold, and ENERGY STAR certifications for the entire project.

BUILDING AMERICA↗

DOE Zero Energy Ready Home Case Study: Amaris Custom Homes, St. Paul, Minnesota

For this project, Amaris worked with U.S. Department of Energy (DOE) team, NorthernSTAR Building America Partnership, to develop the first Zero Energy Ready Home (ZERH) in Minnesota's cold climate using reasonable, cost-effective, and replicable construction materials and practices. The result is a passive solar, super-efficient 3542-ft2 walkout ranch-style home with all the creature comforts. Along with meeting ZERH standards, Amaris also achieved certifications for Leadership in Energy & Environmental Design for Homes v4, MN Green Path Emerald, and a Builders Association of the Twin Cities Reggie Award of Excellence. The home achieves a HERS score of 41 without photovoltaics; with PV, the home achieves a HERS score of 5.

Building America↗

Technology Solutions Case Study: Hygrothermal Performance of a Double-Stud Cellulose Wall

Moisture problems within the building shell can be caused by a number of factors including excess interior moisture that is transported into the wall through air leakage and vapor drive, bulk water intrusion from leaks and wind-driven rain, capillary action from concrete to wood connections, and through wetted building materials such as siding wetted from rain splash back. With the increasing thickness of walls, moisture issues could increase. Several builders have successfully used “double-wall” systems to more practically achieve higher R-values in thicker framed walls. A double wall typically consists of a load-bearing external frame wall constructed with 2 × 4 framing at 16 in. on center using conventional methods. After the building is enclosed, an additional frame wall is constructed several inches inside the load-bearing wall. Several researchers have used moisture modeling software to conduct extensive analysis of these assemblies; however, little field research has been conducted to validate the results. In this project, the Building America research team Consortium for Advanced Residential Buildings monitored a double-stud assembly in climate zone 5A to determine the accu¬racy of moisture modeling and make recommendations to ensure durable and efficient assemblies.

Building America↗

New Whole-House Solutions Case Study: Zero Energy Ready Home Multifamily Project: Mutual Housing at Spring Lake

Building cost effective, high performance homes that provide superior comfort, health, and durability is the goal of the Department of Energy's (DOE's) Zero Energy Ready Homes (ZERH) program. This case study describes the development of a 62-unit multifamily community constructed by nonprofit developer Mutual Housing at the Spring Lake subdivision in Woodland, California. The Spring Lake project is expected to be the first ZERH-certified multifamily project nationwide. Building America team Alliance for Residential Building Innovation worked with Mutual Housing throughout the project. An objective of this project was to gain a highly visible foothold for residential buildings built to the DOE ZERH specification that can be used to encourage participation by other California builders.

ARBI↗

DOE Zero Energy Ready Home Case Study: Clifton View Homes, Coupeville, Washington

Ted Clifton, founder of Clifton View Homes, achieved an impressive Home Energy Rating System (HERS) score of 34 (without solar panels) on a two-story home completed in July 2011 that also earned him his first Challenge Home certification from the U.S. Department of Energy (DOE). This home also garnered a 2013 Housing Innovation Award in the "systems builder" category.

Challenge Home↗

DOE Zero Energy Ready Home Case Study, Weiss Building & Development, LLC., System Home, River Forest, Illinois

The Passive House Challenge Home located in River Forest, Illinois, is a 5-bedroom, 4.5-bath, 3,600 ft2 two-story home (plus basement) that costs about $237 less per month to operate than a similar sized home built to the 2009 IECC. For a home with no solar photovoltaic panels installed, it scored an amazingly low 27 on the Home Energy Rating System (HERS) score.An ENERGY STAR-rated dishwasher, clothes washer, and refrigerator; an induction cooktop, condensing clothes dryer, and LED lighting are among the energy-saving devices inside the home. All plumbing fixtures comply with EPA WaterSense criteria. The home was awarded a 2013 Housing Innovation Award in the "systems builder" category.

Building America↗