Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biosensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

ABF DFO with Technology Holding, Inc.

This Agile BioFoundry Directed Funding Opportunity project with Technology Holding and partners focuses on the development of both a strain of Pseudomonas putida KT2440 and a corresponding bioprocess to convert cellulosic sugars to beta-ketoadipic acid, which can be used in performance nylons and polyesters. Our approach follows the Design-Build-Test-Learn cycle wherein we have transferred learnings from muconic acid production in P. putida to develop a glucose and xylose-utilizing beta-ketoadipic acid production strain. This strain achieves 65 g/L of beta-ketoadipic acid at 0.7 g/L/hr and a C-mol yield of 0.40. We are currently on-boarding arabinose utilization as well. To identify non-intuitive strain modifications as well, we are deploying a beta-ketoadipic acid biosensor and building randomly barcoded transposon insertion sequencing (RB-TnSeq) libraries and gene over-expression libraries in beta-ketoadipic acid production strains. Moreover, we are using global metabolomics and other systems biology tools to identify off-target pathways. Lastly, we are scaling up beta-ketoadipic acid production to kg-scale production for Technology Holding to evaluate in performance polymers with their partners.

beta-ketoadipic acid↗

Photoluminescence-enhanced biocompatible quantum dots by phospholipid functionalization

A simple two-step strategy using phospholipid (PPL) to functionalize core/shell CdSe/ZnS quantum dots (QDs) has been described. The experimental data show that the use of S-H terminated PPL results not only in the high colloidal stability of core/shell CdSe/ZnS QDs in the aqueous phase, but also in the significant enhancement of photoluminescence. The degree of the enhancement is a function of the PPL-CdSe/ZnS QDs sample concentration. These results might be promising for future biological platform in new devices ranging from photovoltaic cells to biosensors and other devices.

36 MATERIALS SCIENCE↗

ROS and NF-{kappa}B are involved in upregulation of IL-8 in A549 cells exposed to multi-walled carbon nanotubes

Carbon nanotubes (CNTs) have potential applications in biosensors, tissue engineering, and biomedical devices because of their unique physico-chemical, electronic and mechanical properties. However, there is limited literature data available concerning the biological properties and toxicity of CNTs. This study aimed to assess the toxicity exhibited by multi-walled CNTs (MWCNTs) and to elucidate possible molecular mechanisms underlying the biological effects of MWCNTs in A549 cells. Exposing A549 cells to MWCNTs led to cell death, changes in cell size and complexity, reactive oxygen species (ROS) production, interleukin-8 (IL-8) gene expression and nuclear factor (NF)-{kappa}B activation. Treatment of A549 cells with antioxidants prior to adding MWCNTs decreased ROS production and abrogated expression of IL-8 mRNA. Pretreatment of A549 cells with NF-{kappa}B inhibitors suppressed MWCNTs-induced IL-8 mRNA expression. These results indicate that MWCNTs are able to induce expression of IL-8 in A549 cells, at least in part, mediated by oxidative stress and NF-{kappa}B activation.

60 APPLIED LIFE SCIENCES↗

Aptamer Microarrays

In vitro selection can yield specific, high-affinity aptamers. We and others have devised methods for the automated selection of aptamers, and have begun to use these reagents for the construction of arrays. Arrayed aptamers have proven to be almost as sensitive as their solution phase counterparts, and when ganged together can provide both specific and general diagnostic signals for proteins and other analytes. We describe here technical details regarding the production and processing of aptamer microarrays, including blocking, washing, drying, and scanning. We will also discuss the challenges involved in developing standardized and reproducible methods for binding and quantitating protein targets. While signals from fluorescent analytes or sandwiches are typically captured, it has proven possible for immobilized aptamers to be uniquely coupled to amplification methods not available to protein reagents, thus allowing for protein-binding signals to be greatly amplified. Into the future, many of the biosensor methods described in this book can potentially be adapted to array formats, thus further expanding the utility of and applications for aptamer arrays.

59 BASIC BIOLOGICAL SCIENCES↗

Chemical, Biological, and Explosive Sensors for Field Measurements

Special Technologies Laboratory (STL) is developing handheld chemical, biological, and explosive (CBE) detection systems and sensor motes for wireless networked field operations. The CBE sensors are capable of detecting and identifying multiple targeted toxic industrial chemicals (TICs) and high-explosive vapor components. The CBE devices are based on differential mobility spectrometry (DMS) coupled with fast gas chromatography (GC) or mass spectrometry. The systems all include the concepts of: 1. Direct air/particulate “smart” sampling 2. Selective, continuous real-time (~1 sec) alert monitoring using DMS 3. Highly selective, rapid dual technology separation/verification analysis The biosensor technology is based on Raman aerosol particle flow cytometry for target detection and identification. Monitoring and identifying trace level chemical vapors directly from ambient air will allow First Responders to quickly adapt situational response strategies and personal protective equipment needs to the specific response scenario being encountered. First Responders require great confidence in the measurements and ability of a given system to detect CBE below threshold levels without interferences. The concept of determining the background matrix in near real-time to allow subsequent automated field-programmable method selection and cueing of high-value assets in a wide range of environs will be presented. This provides CBE information for decisions prior to First Responders entering the response site or sending a portable mobile unit for a remote site survey of the hazards. The focus is on real-time information needed by those responsible for emergency response and national security.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multichannel waveguides for the simultaneous detection of disease biomarkers

The sensor team at the Los Alamos National Laboratory has developed a waveguide-based optical biosensor that has previously been used for the detection of biomarkers associated with diseases such as tuberculosis, breast cancer, anthrax and influenza in complex biological samples (e.g., serum and urine). However, no single biomarker can accurately predict disease. To address this issue, we developed a multiplex assay for the detection of components of the Bacillus anthracis lethal toxin on single mode planar optical waveguides with tunable quantum dots as the fluorescence reporter. This limited ability to multiplex is still insufficient for accurate detection of disease or for monitoring prognosis. In this manuscript, we demonstrate for the first time, the design, fabrication and successful evaluation of a multichannel planar optical waveguide for the simultaneous detection of at least three unknown samples in quadruplicate. We demonstrate the simultaneous, rapid (30 min), quantitative (with internal standard) and sensitive (limit of detection of 1 pM) detection of protective antigen and lethal factor of Bacillus anthracis in complex biological samples (serum) using specific monoclonal antibodies labeled with quantum dots as the fluorescence reporter.

59 BASIC BIOLOGICAL SCIENCES↗

Lipid nanotube or nanowire sensor

A sensor apparatus comprising a nanotube or nanowire, a lipid bilayer around the nanotube or nanowire, and a sensing element connected to the lipid bilayer. Also a biosensor apparatus comprising a gate electrode; a source electrode; a drain electrode; a nanotube or nanowire operatively connected to the gate electrode, the source electrode, and the drain electrode; a lipid bilayer around the nanotube or nanowire, and a sensing element connected to the lipid bilayer.

47 OTHER INSTRUMENTATION↗

Controlled microfluidic production of alginate beads for in situ encapsulation of microbes

The development and refinement of a microfluidic-based alginate bead generator system for bacterial encapsulation is presented. The resulting microgels have application for the encapsulation of single cells, and can allow for small scale, clonal expansion of thousands of isolated cells in parallel. PDMS based microfluidic chips were fabricated using conventional lithography techniques to produce both externally gelled and directly gelled alginate microspheres using a controlled, water-in-oil emulsion system. The production of directly gelled beads, formed by the in-chip mixing of aqueous alginate and calcium chloride solutions dispersed within an organic carrier flowstream is qualitatively compared to a system, which produces beads and relies on diffusion of a crosslinking agent from the carrier fluid to cause gelation (external gelation). While the direct gelation scheme allows the use of biocompatible oils as the organic carrier, it also has a detrimental effect on device stability often resulting in clogging and gel-streaming at the microfluidic interface of these solutions. A design for the continuous production of directly gelled beads was evaluated in terms of the threshold flow conditions and reagent concentrations that did not result in clogging or streaming. Monodisperse alginate microgels of 30 mum diameter were produced at frequencies of over 500 beads per second. The beads could be completely dispersed into aqueous media using an off-chip washing protocol to remove the organic phase. The microgels effectively encapsulated individual or small numbers of GFP-expressing Escherichia. coli, which could be subsequently clonally expanded. The described microfluidic platform is a robust front-end sample preparation technology that shows strong potential for use in drug delivery systems, biosensors, and other cell-based microcompartmentalization applications. The co-culturing of microbial colonies in a large population of alginate beads will allow for functional - sorting and genetic analyses at the single cell level.

59 BASIC BIOLOGICAL SCIENCES↗

Reactive Surfaces and Interfaces utilizing 2-Vinyl-4,4-Dimethylazlactone (VDMA): An Example of ??Click?? Chemistry

Creating polymer-modified interfaces decorated with biologically-relevant materials V so-called bio-interfaces V with precise control over the nanoscale structure and properties is of increasing technological importance for a large number of advanced materials applications, including adaptive and/or lubricious biomaterial coatings, electro-actuators (synthetic muscles), biosensors with amplified response, coatings for stealth drug delivery, supports for enzymatic catalysts, protein or antibody arrays, and high affinity separation agents. The ability to design and decorate interfaces with biologically-relevant molecules and understand synthesis-structure-function relationships remains a significant challenge. The overarching objective of this research program is to investigate the polymerization and functionalization of a new class of polymeric materials that are capable of serving as a versatile platform from which bio-interfaces for specific applications can be created and evaluated. Stimuli-responsive (co)polymers containing vinyl dimethyl azlactone (VDMA) have been prepared using free radical polymerization techniques (controlled and conventional). Subsequent immobilization of biomolecules (e.g., dansylcadaverine, N ,N -bis(carboxymethyl)-L-lysine hydrate) on PVDMA-containing surface scaffolds affords bio-interfaces. Reaction of nucleophiles with the azlactone moiety proceeds rapidly, quantitatively, and in the absence of byproducts, which are essential criteria governing the click-type nature of this procedure. The conversion of these materials into polyelectrolytes and bioconjugates can be monitored in real-time using infrared spectroscopy. Additionally, pVDMA polymers prepared using reversible addition fragmentation chain transfer (RAFT) polymerization are the basis for creating polymer brushes by a grafting to approach. We will describe how compositional differences and changes in molecular weight affect the solubility and responsiveness of pVDMA-based polymers and surface layers when functionalized with various biomolecules.

36 MATERIALS SCIENCE↗

Process for preparing multilayer enzyme coating on a fiber

A process for preparing high stability, high activity biocatalytic materials is disclosed and processes for using the same. The process involves coating of a material or fiber with enzymes and enzyme aggregate providing a material or fiber with high biocatalytic activity and stability useful in heterogeneous environments. In one illustrative approach, enzyme "seeds" are covalently attached to polymer nanofibers followed by treatment with a reagent that crosslinks additional enzyme molecules to the seed enzymes forming enzyme aggregates thereby improving biocatalytic activity due to increased enzyme loading and enzyme stability. This approach creates a useful new biocatalytic immobilized enzyme system with potential applications in bioconversion, bioremediation, biosensors, and biofuel cells.

36 MATERIALS SCIENCE↗

Lipid nanotube or nanowire sensor

A sensor apparatus comprising a nanotube or nanowire, a lipid bilayer around the nanotube or nanowire, and a sensing element connected to the lipid bilayer. Also a biosensor apparatus comprising a gate electrode; a source electrode; a drain electrode; a nanotube or nanowire operatively connected to the gate electrode, the source electrode, and the drain electrode; a lipid bilayer around the nanotube or nanowire, and a sensing element connected to the lipid bilayer.

47 OTHER INSTRUMENTATION↗

Nitrogen Metabolism in Pseudomonas putida : Functional Analysis Using Random Barcode Transposon Sequencing

Pseudomonas putida KT2440 has long been studied for its diverse and robust metabolisms, yet many genes and proteins imparting these growth capacities remain uncharacterized. Using pooled mutant fitness assays, we identified genes and proteins involved in the assimilation of 52 different nitrogen containing compounds. To assay amino acid biosynthesis, 19 amino acid drop-out conditions were also tested. From these 71 conditions, significant fitness phenotypes were elicited in 672 different genes including 100 transcriptional regulators and 112 transport-related proteins. We divide these conditions into 6 classes, and propose assimilatory pathways for the compounds based on this wealth of genetic data. To complement these data, we characterize the substrate range of three promiscuous aminotransferases relevant to metabolic engineering efforts in vitro. So we examine the specificity of five transcriptional regulators, explaining some fitness data results and exploring their potential to be developed into useful synthetic biology tools. In addition, we use manifold learning to create an interactive visualization tool for interpreting our BarSeq data, which will improve the accessibility and utility of this work to other researchers.

59 BASIC BIOLOGICAL SCIENCES↗

Methylxanthine Drug Monitoring with Wearable Sweat Sensors

Drug monitoring plays crucial roles in doping control and precision medicine. It helps physicians tailor drug dosage for optimal benefits, track patients' compliance to prescriptions, and understand the complex pharmacokinetics of drugs. Conventional drug tests rely on invasive blood draws. While urine and sweat are attractive alternative biofluids, the state-of-the-art methods require separate sample collection and processing steps and fail to provide real-time information. In this paper, a wearable platform equipped with an electrochemical differential pulse voltammetry sensing module for drug monitoring is presented. A methylxanthine drug, caffeine, is selected to demonstrate the platform's functionalities. Sweat caffeine levels are monitored under various conditions, such as drug doses and measurement time after drug intake. Elevated sweat caffeine levels upon increasing dosage and confirmable caffeine physiological trends are observed. This work leverages a wearable sweat sensing platform toward noninvasive and continuous point-of-care drug monitoring and management.

47 OTHER INSTRUMENTATION↗

Flexible Electrochemical Bioelectronics: The Rise of In Situ Bioanalysis

The amalgamation of flexible electronics in biological systems has shaped the way health and medicine are administered. The growing field of flexible electrochemical bioelectronics enables the in situ quantification of a variety of chemical constituents present in the human body and holds great promise for personalized health monitoring owing to its unique advantages such as inherent wearability, high sensitivity, high selectivity, and low cost. It represents a promising alternative to probe biomarkers in the human body in a simpler method compared to conventional instrumental analytical techniques. Various bioanalytical technologies are employed in flexible electrochemical bioelectronics, including ion-selective potentiometry, enzymatic amperometry, potential sweep voltammetry, field-effect transistors, affinity-based biosensing, as well as biofuel cells. Recent key innovations in flexible electrochemical bioelectronics from electrochemical sensing modalities, materials, systems, fabrication, to applications are summarized and highlighted. The challenges and opportunities in this field moving forward toward future preventive and personalized medicine devices are also discussed here.

47 OTHER INSTRUMENTATION↗

Flexible Electronics: Flexible Electrochemical Bioelectronics: The Rise of In Situ Bioanalysis (Adv. Mater. 15/2020)

Flexible electrochemical bioelectronics enables in situ quantification of a variety of chemical constituents present in the human body. It holds great promise for personalized health monitoring owing to its inherent wearability, high performance, and low cost. In article number 1902083, Wei Gao, Ali Javey, and co-authors summarize recent key innovations in flexible electrochemical bioelectronics from electrochemical sensing modalities, materials, systems, fabrication, to applications and discuss the challenges and opportunities in this field moving forward toward future preventive and personalized medicine devices.

36 MATERIALS SCIENCE↗

Photocaged DNAzymes as a general method for sensing metal ions in living cells

DNAzymes, which are sequences of DNA with catalytic activity, have been demonstrated as a potential platform for sensing a wide range of metal ions. Despite their significant promise, cellular sensing using DNAzymes has however been difficult, mainly because of the “always-on” mode of first-generation DNAzyme sensors. In this paper, to overcome this limitation, a photoactivatable (or photocaged) DNAzyme was designed and synthesized, and its application in sensing Zn lI in living cells was demonstrated. In this design, the adenosine ribonucleotide at the scissile position of the 8–17 DNAzyme was replaced by 2'-O-nitrobenzyl adenosine, rendering the DNAzyme inactive and thus allowing its delivery into cells intact, protected from nonspecific degradation within cells. Irradiation at 365 nm restored DNAzyme activity, thus allowing the temporal control over the sensing activity of the DNAzyme for metal ions. Finally, the same strategy was also applied to the GR-5 DNAzyme for the detection of PbII, thus demonstrating the possible scope of the method.

59 BASIC BIOLOGICAL SCIENCES↗

Programming A Molecular Relay for Ultrasensitive Biodetection through 129 Xe NMR

We reported a supramolecular strategy for detecting specific proteins in complex media by using hyperpolarized 129 Xe NMR. A cucurbit[6]uril (CB[6])-based molecular relay was programmed for three sequential equilibrium conditions by designing a two-faced guest (TFG) that initially binds CB[6] and blocks the CB[6]–Xe interaction. Moreover, the protein analyte recruits the TFG and frees CB[6] for Xe binding. TFGs containing CB[6]- and carbonic anhydrase II (CAII)-binding domains were synthesized in one or two steps. X-ray crystallography confirmed TFG binding to Zn 2+ in the deep CAII active-site cleft, which precludes simultaneous CB[6] binding. The molecular relay was reprogrammed to detect avidin by using a different TFG. Finally, Xe binding by CB[6] was detected in buffer and in E. coli cultures expressing CAII through ultrasensitive 129 Xe NMR spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polyoxometalate-Graphene Nanocomposite Modified Electrode for Electrocatalytic Detection of Ascorbic Acid

Phosphomolybdate functionalized graphene nanocomposite (PMo 12 -GS) has been successfully formed on a glassy carbon electrode (GCE) for the detection of ascorbic acid (AA). The obtained PMo 12 -GS modified GCE, was characterized by cyclic voltammetry, electrochemical impedance spectroscopy, scanning electron microscopy (SEM) and Fourier transform infrared (FT-IR) spectroscopy and compared with GCE, GS modified GCE, and PMo 12 modified GCE. It shows an increased current and a decrease in over-potential of ~210 mV. The amperometric signals are linearly proportional to the AA concentration in a wide concentration range from 1×10 -6 M to 8×10 -3 M, with a detection limit of 0.5×10 -6 M. Finally, the PMo 12 -GS modified electrode was employed for the determination of the AA level in vitamin C tablets, with recoveries between 96.3 and 100.8 %.

Ascorbic Acid↗