Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biomedical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Gravity Sensors and the Role of 3-D Visualization and Simulation in Biomedical Research

Ross 3.0 software was developed in the Biocomputation Center for semi-automated reconstruction of objects from serial thin sections. Data are captured directly from a transmission electron microscope via a video camera to a graphics workstation where the sections are mosaicked and contours are traced, registered and displayed by semi-automated methods. For the first time, macular type II cells are described completely for their innervation patterns. The purposes are to learn more about the fundamental circuitry of the macula and to demonstrate whether the terminals are altered morphologically by space flight. Current examples, from the medial part of the macula, are from maculas collected in-flight on the Space Life Sciences-2 mission, 4.5 hrs post-flight, and from a ground control. Results show that the typical type 11 cell receives processes from up to six nearby calyces or afferents. Nearly all the processes are elongated; some have bouton-like swellings and numerous vesicles. Multiple (2 to 4) processes from a single calyx to a type II cell are common, and approx. 1/3 of the processes innervate 2 type II cells of a neighboring cluster of 3 cells. About 2% of type II cells resemble type I cells morphologically and are surrounded by demicalyces. Differences in size or shape of the terminals under flight conditions could not be determined because the sample size is still too small; but it is clear that reconstruction methods provide insights into macular circuitry not obtainable by other techniques. The results demonstrate a morphological basis for interactions between adjacent receptive fields, through feedback-feedforward connections, during preprocessing of linear acceleratory information by the maculas. While the methods are currently being tested using vestibular maculas as the model system, it is clear that the technology is applicable to any tissue that can be physically or optically sectioned. ROSS software has already been implemented for reconstructing objects from tissues studied by confocal and by transmitted light microscopy, and research into magnetic resonance imaging-computational tomography combined visualization are underway.

Ross, Muriel D.↗

Biomedical Application of Aerospace Personal Cooling Systems

Personal thermoregulatory systems which are used by astronauts to alleviate thermal stress during extravehicular activity have been applied to the therapeutic management of multiple sclerosis. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 10 male and female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.22C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. In general, the male and female subjects' oral and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx. 0.2 - 0.5C, for both men and women wearing any of the four different garments. The corresponding ear temperatures were significantly (P<0.05) decreased approx.0.2 - 0.4C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods.

Ku, Yu-Tsuan E.↗

Electrospraying and Electrospinning of Polymers for Biomedical Applications. Poly(Lactic-Co-Glycolic Acid) and Poly(Ethylene-Co-Vinylacetate)

Significant opportunities exist for the processing of polymers (homopolymers and blends) using electric fields. Specific attention is given here to electrospinning, but we note that electroaerosol formation and field-modulated film casting represent additional processing options. Of particular interest is the ability to generate polymer fibers of sub-micron dimensions using electrospinning, down to about 0.05 microns (50 nm), a size range that has been traditionally difficult to access. In our work, poly(lactic-co-glycolic acid), PLA/PGA, poly(lactic acid) PLA, and poly(ethylene-co-vinylacetate) (PEVA) have been deposited from solutions in methylene chloride or chloroform by electrospraying or electrospinning to afford morphologically tailored materials for tissue engineering and related applications. Low solution concentrations tend to favor electrostatic spraying ('electro-aerosolization') while higher concentrations lead to spinning on fibrous mats. Preliminary observations of muscle cell growth on PLA electrospun mats are reported.

Stitzel, Joel D.↗

Applications of SPICE for modeling miniaturized biomedical sensor systems

This paper proposes a model for a miniaturized signal conditioning system for biopotential and ion-selective electrode arrays. The system consists of three main components: sensors, interconnections, and signal conditioning chip. The model for this system is based on SPICE. Transmission-line based equivalent circuits are used to represent the sensors, lumped resistance-capacitance circuits describe the interconnections, and a model for the signal conditioning chip is extracted from its layout. A system for measurements of biopotentials and ionic activities can be miniaturized and optimized for cardiovascular applications based on the development of an integrated SPICE system model of its electrochemical, interconnection, and electronic components.

Microelectrodes↗

Biomedical Risk Mitigation: 1994-2004

This custom bibliography from the NASA Scientific and Technical Information Program lists a sampling of records found in the NASA Aeronautics and Space Database. The scope of this topic includes space medicine, remote monitoring, diagnosis, and treatment. This area of focus is one of the enabling technologies as defined by NASA s Report of the President s Commission on Implementation of United States Space Exploration Policy, published in June 2004.

Source record↗

Parallel line analysis: multifunctional software for the biomedical sciences

An easy to use, interactive FORTRAN program for analyzing the results of parallel line assays is described. The program is menu driven and consists of five major components: data entry, data editing, manual analysis, manual plotting, and automatic analysis and plotting. Data can be entered from the terminal or from previously created data files. The data editing portion of the program is used to inspect and modify data and to statistically identify outliers. The manual analysis component is used to test the assumptions necessary for parallel line assays using analysis of covariance techniques and to determine potency ratios with confidence limits. The manual plotting component provides a graphic display of the data on the terminal screen or on a standard line printer. The automatic portion runs through multiple analyses without operator input. Data may be saved in a special file to expedite input at a future time.

NASA Discipline Cell Biology↗

Biomedical Aspects of Lunar and Mars Exploration Missions

Recent long-range planning for exploration-class missions has emphasized the need for anticipating the medical and human factors aspects of such expeditions. Missions returning Americans to the moon for stays of up to 6 months at a time will provide the opportunity to demonstrate the means to function safely and efficiently on another planet. Details of mission architectures are still under study, but a typical Mars design reference mission comprises a six-month transit from Earth to Mars, eighteen months in residence on Mars, and a six-month transit back to Earth. Physiological stresses will come from environmental factors such as prolonged exposure to radiation, weightlessness en route to Mars and then back to Earth, and low gravity and a toxic atmosphere while on Mars. Psychological stressors will include remoteness from Earth, confinement, and potential interpersonal conflicts, all complicated by circadian alterations. Medical risks including trauma must be considered. The role of such risk-modifying influences as artificial gravity and improved propulsion technologies to shorten round-trip time will also be discussed. Results of planning for assuring human health and performance will be presented.

Charles, John B.↗

Coherent inductive communications link for biomedical applications

A two-way coherent inductive communications link between an external transceiver and an internal transceiver located in a biologically implanted programmable medical device. Digitally formatted command data and programming data is transmitted to the implanted medical device by frequency shift keying the inductive communications link. Internal transceiver is powered by the inductive field between internal and external transceivers. Digitally formatted data is transmitted to external transceiver by internal transceiver amplitude modulating inductive field. Immediate verification of the establishment of a reliable communications link is provided by determining existence of frequency lock and bit phase lock between internal and external transceivers.

Hogrefe, Arthur F.↗

Carbon-Nanotube-Based Electrodes for Biomedical Applications

A nanotube array based on vertically aligned nanotubes or carbon nanofibers has been invented for use in localized electrical stimulation and recording of electrical responses in selected regions of an animal body, especially including the brain. There are numerous established, emerging, and potential applications for localized electrical stimulation and/or recording, including treatment of Parkinson s disease, Tourette s syndrome, and chronic pain, and research on electrochemical effects involved in neurotransmission. Carbon-nanotube-based electrodes offer potential advantages over metal macroelectrodes (having diameters of the order of a millimeter) and microelectrodes (having various diameters ranging down to tens of microns) heretofore used in such applications. These advantages include the following: a) Stimuli and responses could be localized at finer scales of spatial and temporal resolution, which is at subcellular level, with fewer disturbances to, and less interference from, adjacent regions. b) There would be less risk of hemorrhage on implantation because nano-electrode-based probe tips could be configured to be less traumatic. c) Being more biocompatible than are metal electrodes, carbon-nanotube-based electrodes and arrays would be more suitable for long-term or permanent implantation. d) Unlike macro- and microelectrodes, a nano-electrode could penetrate a cell membrane with minimal disruption. Thus, for example, a nanoelectrode could be used to generate an action potential inside a neuron or in proximity of an active neuron zone. Such stimulation may be much more effective than is extra- or intracellular stimulation via a macro- or microelectrode. e) The large surface area of an array at a micron-scale footprint of non-insulated nanoelectrodes coated with a suitable electrochemically active material containing redox ingredients would make it possible to obtain a pseudocapacitance large enough to dissipate a relatively large amount of electric charge, so that a large stimulation current could be applied at a micron-scale region without exhausting the redox ingredients. f) Carbon nanotube array is more compatible with the three-dimensional network of tissues. Particularly, a better electrical-neural interface can be formed. g) A carbon nanotube array inlaid in insulating materials with only the ends exposed is an extremely sensitive electro-analysis tool that can measure the local neurotransmitter signal at extremely high sensitivity and temporal resolution.

Li, Jun↗

Statistical Challenges in Biomedical Research

Potentially debilitating effects of spaceflight environment include: a) Bone Demineralization - Osteoporosis. b)Impaired Fracture Healing - Non-Union. c) Renal Stone Formation & Soft Tissue Calcification. d) Orthostatic Intolerance (on return to gravity). e) Cardiac Arrhythmias. f) Dehydration (on return to gravity). g) Decreased Aerobic Capacity. h) Impaired Coordination. i) Muscle Atrophy (Loss of Strength). j) Radiation Sickness. k) Increased Cancer Risk. l) Impaired Immune Function. m) Behavioral Changes & Performance Decrements n) Altitude Decompression Sickness during EVA.

Feiveson, Alan H.↗

The Value of Biomedical Simulation Environments to Future Human Space Flight Missions

Mars and NEO missions will expose astronaut to extended durations of reduced reduced gravity, isolation and higher radiation. These new operation conditions pose health risks that are not well understood and perhaps unanticipated. Advanced computational simulation environments can beneficially augment research to predict, assess and mitigate potential hazards to astronaut health. The NASA Digital Astronaut Project (DAP), within the NASA Human Research Program, strives to achieve this goal.

Mulugeta,Lealem↗

Biomedical Monitoring By A Novel Noncontact Radio Frequency Technology Project

The area of Space Health and Medicine is one of the NASA's Space Technology Grand Challenges. Space is an extreme environment which is not conducive to human life. The extraterrestrial environment can result in the deconditioning of various human physiological systems and thus require easy to use physiological monitoring technologies in order to better monitor space crews for appropriate health management and successful space missions and space operations. Furthermore, the Space Technology Roadmap's Technology Area Breakdown Structure calls for improvements in research to support human health and performance (Technology Area 06). To address these needs, this project investigated a potential noncontact and noninvasive radio frequency-based technique of monitoring central hemodynamic function in human research subjects in response to orthostatic stress.

Portfolio↗

Low Profile Tunable Dipole Antenna Using BST Varactors for Biomedical Applications

In this paper a 2.4 GHz low profile (lambda/47) tunable dipole antenna is evaluated in the presence of a human core model (HCM) body phantom. The antenna uses a frequency selective surface (FSS) with interdigital barium strontium titanate (BST) varactor-tuned unit cells and its performance is compared to a similar low profile antenna that uses an FSS with semiconductor varactor diodes. The measured data of the antenna demonstrate tunability from 2.2 GHz to 2.55 GHz in free space and impedance match improvement in the presence of a HCM at different distances. This antenna has smaller size, lower cost and less weight compared to the semiconductor varactor diode counterpart.

frequency selective surfaces↗

National Space Biomedical Research Institute (NSBRI) JSC Summer Projects

This project optimized the calorie content in a breakfast meal replacement bar for the Advanced Food Technology group. Use of multivariable optimization yielded the highest weight savings possible while simultaneously matching NASA Human Standards nutritional guidelines. The scope of this research included the study of shelf-life indicators such as water activity, moisture content, and texture analysis. Key metrics indicate higher protein content, higher caloric density, and greater mass savings as a result of the reformulation process. The optimization performed for this study demonstrated wide application to other food bars in the Advanced Food Technology portfolio. Recommendations for future work include shelf life studies on bar hardening and overall acceptability data over increased time frames and temperature fluctuation scenarios.

Dowdy, Forrest Ryan↗