Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analyzed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

A Second-Generation Volatile Organic Analyzer for the International Space Station

Early in the development of the Crew Health Care System (CHECS) for the International Space Station (ISS), it was recognized that detection of target volatile organic compounds would be a key component of the air monitoring strategy. Experiences during the NASA/Mir program supported the decision to include a real-time volatile organic analyzer (VOA) aboard ISS to help assess the impact of air quality events on crew health and determine the effectiveness of decontamination efforts. Toward this end, a joint development by the Toxicology Laboratory at Johnson Space Center and Graseby Dynamics produced a VOA that has been delivered and is ready for the first 5 years of ISS operation. The first-generation VOA selection criteria included minimizing size, weight, and power consumption while maintaining analytical performance. Measuring available technologies against these criteria, a VOA system based upon gas chromatography/ion mobility spectrometry (GC/IMS) was selected in the mid-90's. However, as NASA looks forward to later-stage ISS operations and to new frontiers such as human exploration of Mars, the ISS VOA (weighing 43 kg and consuming 160 watts) must be replaced by a smaller, less resource-intensive device. This paper will present a possible second-gene ration VOA based upon the same technology as the first-generation unit. Utilizing GC/IMS technology again will permit the instrumental data and experience gained during the initial phase of ISS to be applied to later ISS phases and advanced spacecraft missions. During the past 3 years, efforts to reduce the size of ion mobility spectrometers have been pursued by Graseby Dynamics, the manufacturer of the first-generation VOA. The concept of operation, expected analytical performance, and estimated size of a fully functional second-generation VOA based upon GC/mini-IMS technology will be presented. Furthermore, results of initial laboratory evaluations will be shown.

Limero, Thomas↗

Analyzing The Effect of Skin Postbuckling on General Stresses, Strains and Stability of Composite Structures

The present paper is a final technical report within the NCCW-1-233 research program (dated June 1, 1997) accomplished as a part of co-operation between United States' NASA and Russia's Goskomoboronprom in aeronautics, and continues similar NCCW-73 and NCC-1-233 programs accomplished in 1996 and 1997, respectively. The report concludes studies in two domains, "Analyzing the effect of skin postbuckling on general stresses and strains in a composite structure" and "Evaluating the effect of skin postbuckling behavior on general stability of a composite structure"; the work was fulfilled in compliance with NCC-1-233 requirements (as of June 1, 1997). Also, the present studies may be regarded as a partial generalization of efforts in [1, 2] conducted within the above programs in what concerns postbuckling behavior of composite structures.

Zamula, G. N.↗

Regolith Evolved Gas Analyzer

The Regolith Evolved Gas Analyzer (REGA) is a high-temperature furnace and mass spectrometer instrument for determining the mineralogical composition and reactivity of soil samples. REGA provides key mineralogical and reactivity data that is needed to understand the soil chemistry of an asteroid, which then aids in determining in-situ which materials should be selected for return to earth. REGA is capable of conducting a number of direct soil measurements that are unique to this instrument. These experimental measurements include: (1) Mass spectrum analysis of evolved gases from soil samples as they are heated from ambient temperature to 900 C; and (2) Identification of liberated chemicals, e.g., water, oxygen, sulfur, chlorine, and fluorine. REGA would be placed on the surface of a near earth asteroid. It is an autonomous instrument that is controlled from earth but does the analysis of regolith materials automatically. The REGA instrument consists of four primary components: (1) a flight-proven mass spectrometer, (2) a high-temperature furnace, (3) a soil handling system, and (4) a microcontroller. An external arm containing a scoop or drill gathers regolith samples. A sample is placed in the inlet orifice where the finest-grained particles are sifted into a metering volume and subsequently moved into a crucible. A movable arm then places the crucible in the furnace. The furnace is closed, thereby sealing the inner volume to collect the evolved gases for analysis. Owing to the very low g forces on an asteroid compared to Mars or the moon, the sample must be moved from inlet to crucible by mechanical means rather than by gravity. As the soil sample is heated through a programmed pattern, the gases evolved at each temperature are passed through a transfer tube to the mass spectrometer for analysis and identification. Return data from the instrument will lead to new insights and discoveries including: (1) Identification of the molecular masses of all of the gases liberated from heated soil samples; (2) Identification of the asteroid soil mineralogy to aid in the selection process for returned samples; (3) Existence of oxygen in the asteroid soil and the potential for in-situ resource utilization (ISRU); and (4) Existence of water and other volatiles in the asteroid soil. Additional information is contained in the original extended abstract.

Hoffman, John H.↗

The Search for Water and Other Volatiles in Martian Surface Materials: The Thermal Evolved Gas Analyzer (TEGA)

Volatile-bearing minerals and phases (e.g., Fe-oxyhydroxides, phyllosilicates, carbonates, sulfates, palagonites, glasses) may be important components of the Martian regolith. However, essentially no information exists on the mineralogical composition of volatile-bearing phases in the regolith. The Thermal Evolved Gas Analyzer (TEGA), which was part of the Mars Polar Lander payload, was to determine the abundances of two of the most important volatile compounds (i.e., water and carbon dioxide) in the martian soil and to identify the minerals or phases that harbor these volatiles. The TEGA instrument was composed of a differential scanning calorimeter (DSC) interfaced with evolved gas analysis (EGA). The EGA consisted of a Herriott cell of a tunable-diode laser (TDL) spectrometer that determines CO2 and H2O abundances. The sample chamber was to operate at about 100 mbar (-76 torr) with a N2 carrier gas flow of 0.4 sccm. Specifications of TEGA are described in detail elsewhere in this volume.

Ming, D. W.↗

Regolith Evolved Gas Analyzer (REGA): An Instrument to Characterize the Martian Soil Mineralogy and Atmosphere Composition

This abstract describes an instrument and experiment to be proposed for a future Mars surface mission to conduct basic research on environmental characterization. The Regolith Evolved Gas Analyzer (REGA) experiment is designed to provide information on Mars surface material properties in preparation for human missions of exploration. The goals of the investigation are: 1) Define and determine surface mineralogy of soil and dust and their effects on humans and machines; and 2) Conduct in-situ investigations aimed at identifying possible evidence of past or present life on Mars.

Hoffman, John H.↗

Laboratory Experimentation Model of the 270 Degree Electron Tophat Analyzer

One of the most important space plasma measurements is that of a well-resolved low-energy (approximately 1 eV to 1 keV) electron spectrum. This range includes the regime where photoelectron and Auger processes are important as well as the very low energy range (down to 1 eV) where electron distributions of temperature 11,000 K are measurable. Knowledge of the structure (approx. eV scale) of the photoelectron spectrum can provide information on the composition of a planetary or cometary atmosphere. As evidence, scientists developing the Analyzer of Space Plasma and Energetic Atoms (ASPERA-3) Electron Spectrometer (ELS) flying on the European Space Agency (ESA) Mars Express Mission have adapted their electron instrument to increase energy resolution in the photoelectron energy region as a means of remotely sensing the Martian atmosphere; the idea being that the Martian magnetic field is so weak that electron interaction between the source and point of detection is nonexistent; the measured electrons are therefore reflective of the processes occurring in the Martian atmosphere.

Frahm, R. A.↗

Evaluating Mass Analyzers as Candidates for Small, Portable, Rugged Single Point Mass Spectrometers for Analysis of Permanent Gases

For Space Shuttle launch safety, there is a need to monitor the concentration Of H2, He, O2, and Ar around the launch vehicle. Currently a large mass spectrometry system performs this task, using long transport lines to draw in samples. There is great interest in replacing this stationary system with several miniature, portable, rugged mass spectrometers which act as point sensors which can be placed at the sampling point. Five commercial and two non-commercial analyzers are evaluated. The five commercial systems include the Leybold Inficon XPR-2 linear quadrupole, the Stanford Research (SRS-100) linear quadrupole, the Ferran linear quadrupole array, the ThermoQuest Polaris-Q quadrupole ion trap, and the IonWerks Time-of-Flight (TOF). The non-commercial systems include a compact double focusing sector (CDFMS) developed at the University of Minnesota, and a quadrupole ion trap (UF-IT) developed at the University of Florida.

Arkin, C. Richard↗

A High-Precision, Fast-Response Airborne CO2 Analyzer for In Situ Sampling From the Surface to the Middle Stratosphere

Two in situ CO2 analyzers have been developed for deployment on the NASA ER-2 aircraft and on stratospheric balloons. The ER-2 instrument has had more than 150 flights during 21 deployments from 1992 to 2000, resulting in a dataset with nearly pole-to-pole coverage that includes data from all seasons in both hemispheres except austral summer. In-flight calibrations show that the typical long-term (i.e. flight-to-flight) precision of the instruments is better than plus or minus 0.1 ppmv. The flight standards are traceable to standards held by the Scripps Institute of Oceanography and the National Oceanic and Atmospheric Administration's Climate Monitoring and Diagnostics Laboratory. The balloon instrument has had 8 balloon flights since September 1996, providing the first in situ observations of CO2 above approx. 21 km. In addition, the balloon instrument has been flown onboard a Cessna Citation II aircraft for sampling between the surface and 10 km. In this paper, the instrumentation and calibration procedures for both instruments are described in detail. An intercomparison of the two instruments during the Photochemistry of Ozone Loss in the Arctic Region In Summer (POLARIS) project showed that, on average, the instruments agreed to within 0.05 ppmv.

Daube, B. C., Jr.↗

Laboratory Experimentation Model of the 270 Degree Electron Tophat Analyzer

One of the most important space plasma measurements is that of a well-resolved low-energy (approx.1 eV to 1 keV) electron spectrum. This range includes the regime where photoelectron and Auger processes are important [Winningham et at., 1989] as well as the very low-energy range (down to 1 eV) where electron distributions of temperature 11,000 K are measurable. Knowledge of the structure (approx. eV scale) of the photoelectron spectrum can provide information on the composition of a planetary or cometary atmosphere. As evidence, scientists developing the Analyzer of Space Plasma and Energetic Atoms (ASPERA-3) Electron Spectrometer (ELS) flying on the European Space Agency (ESA) Mars Express Mission have adapted their electron instrument to increase energy resolution in the photoelectron energy region as a means of remotely sensing the Martian atmosphere; the idea being that the Martian magnetic field is so weak that electron interaction between the source and point of detection is nonexistent; the measured electrons are therefore reflective of the processes occurring in the Martian atmosphere.

Frahm, R. A.↗

Contamination Analyzer

Measurement of the total organic carbon content in water is important in assessing contamination levels in high purity water for power generation, pharmaceutical production and electronics manufacture. Even trace levels of organic compounds can cause defects in manufactured products. The Sievers Model 800 Total Organic Carbon (TOC) Analyzer, based on technology developed for the Space Station, uses a strong chemical oxidizing agent and ultraviolet light to convert organic compounds in water to carbon dioxide. After ionizing the carbon dioxide, the amount of ions is determined by measuring the conductivity of the deionized water. The new technique is highly sensitive, does not require compressed gas, and maintenance is minimal.

Source record↗

Analyzing Water's Optical Absorption

A cooperative agreement between World Precision Instruments (WPI), Inc., and Stennis Space Center has led the UltraPath(TM) device, which provides a more efficient method for analyzing the optical absorption of water samples at sea. UltraPath is a unique, high-performance absorbance spectrophotometer with user-selectable light path lengths. It is an ideal tool for any study requiring precise and highly sensitive spectroscopic determination of analytes, either in the laboratory or the field. As a low-cost, rugged, and portable system capable of high- sensitivity measurements in widely divergent waters, UltraPath will help scientists examine the role that coastal ocean environments play in the global carbon cycle. UltraPath(TM) is a trademark of World Precision Instruments, Inc. LWCC(TM) is a trademark of World Precision Instruments, Inc.

Source record↗

Stress Analyzer

SPATE 900 Dynamic Stress Analyzer is an acronym for Stress Pattern Analysis by Thermal Emission. It detects stress-induced temperature changes in a structure and indicates the degree of stress. Ometron, Inc.'s SPATE 9000 consists of a scan unit and a data display. The scan unit contains an infrared channel focused on the test structure to collect thermal radiation, and a visual channel used to set up the scan area and interrogate the stress display. Stress data is produced by detecting minute temperature changes, down to one-thousandth of a degree Centigrade, resulting from the application to the structure of dynamic loading. The electronic data processing system correlates the temperature changes with a reference signal to determine stress level.

Source record↗

Portable Gas Analyzer

The Michromonitor M500 universal gas analyzer contains a series of miniature modules, each of which is a complete gas chromatograph, an instrument which separates a gaseous mixture into its components and measures the concentrations of each gas in the mixture. The system is manufactured by Microsensor Technology, and is used for environmental analysis, monitoring for gas leaks and chemical spills, compliance with pollution laws, etc. The technology is based on a Viking attempt to detect life on Mars. Ames/Stanford miniaturized the system and NIOSH funded further development. Three Stanford researchers commercialized the technology, which can be operated by unskilled personnel.

Source record↗

Gas Analyzer

A miniature gas chromatograph, a system which separates a gaseous mixture into its components and measures the concentration of the individual gases, was designed for the Viking Lander. The technology was further developed under National Institute for Occupational Safety and Health (NIOSH) and funded by Ames Research Center/Stanford as a toxic gas leak detection device. Three researchers on the project later formed Microsensor Technology, Inc. to commercialize the product. It is a battery-powered system consisting of a sensing wand connected to a computerized analyzer. Marketed as the Michromonitor 500, it has a wide range of applications.

Source record↗

Mineral/Water Analyzer

An x-ray fluorescence spectrometer developed for the Viking Landers by Martin Marietta was modified for geological exploration, water quality monitoring, and aircraft engine maintenance. The aerospace system was highly miniaturized and used very little power. It irradiates the sample causing it to emit x-rays at various energies, then measures the energy levels for sample composition analysis. It was used in oceanographic applications and modified to identify element concentrations in ore samples, on site. The instrument can also analyze the chemical content of water, and detect the sudden development of excessive engine wear.

Source record↗

Modeling, Analyzing, and Mitigating Dissonance Between Alerting Systems

Alerting systems are becoming pervasive in process operations, which may result in the potential for dissonance or conflict in information from different alerting systems that suggests different threat levels and/or actions to resolve hazards. Little is currently available to help in predicting or solving the dissonance problem. This thesis presents a methodology to model and analyze dissonance between alerting systems, providing both a theoretical foundation for understanding dissonance and a practical basis from which specific problems can be addressed. A state-space representation of multiple alerting system operation is generalized that can be tailored across a variety of applications. Based on the representation, two major causes of dissonance are identified: logic differences and sensor error. Additionally, several possible types of dissonance are identified. A mathematical analysis method is developed to identify the conditions for dissonance originating from logic differences. A probabilistic analysis methodology is developed to estimate the probability of dissonance originating from sensor error, and to compare the relative contribution to dissonance of sensor error against the contribution from logic differences. A hybrid model, which describes the dynamic behavior of the process with multiple alerting systems, is developed to identify dangerous dissonance space, from which the process can lead to disaster. Methodologies to avoid or mitigate dissonance are outlined. Two examples are used to demonstrate the application of the methodology. First, a conceptual In-Trail Spacing example is presented. The methodology is applied to identify the conditions for possible dissonance, to identify relative contribution of logic difference and sensor error, and to identify dangerous dissonance space. Several proposed mitigation methods are demonstrated in this example. In the second example, the methodology is applied to address the dissonance problem between two air traffic alert and avoidance systems: the existing Traffic Alert and Collision Avoidance System (TCAS) vs. the proposed Airborne Conflict Management system (ACM). Conditions on ACM resolution maneuvers are identified to avoid dynamic dissonance between TCAS and ACM. Also included in this report is an Appendix written by Lee Winder about recent and continuing work on alerting systems design. The application of Markov Decision Process (MDP) theory to complex alerting problems is discussed and illustrated with an abstract example system.

Song, Lixia↗

Investigating and Analyzing Applied Loads Higher Than Limit Loads

The results of the analysis for Balance 1621 indicate that the stresses are high near sharp corners. It is important to increase the size of the fillets to relieve some of the high stresses for the balances that will be designed. For the existing balances, the stresses are high and do not satisfy the established criteria. Two options are considered here. One is a possible modification of the existing balances, and two is to consider other load options. Redesigning a balance can be done in order to enhance the structural integrity of the balance. Because an existing balance needs to be modified, it is not possible to increase the fillet sizes without some further modifications to the balance. It is required that some materials be extracted from the balance in order to have larger fillet sizes. Researchers are interested in being able to apply some components of the load on the balance above the limit loads assigned. Is it possible to enhance the load on the same balance and maintain the factor of safety required? Some loads were increased above their limit loads and analyzed here.

Karkehabadi, R.↗

Accelerated Testing of Polymeric Composites Using the Dynamic Mechanical Analyzer

Creep properties of IM7/K3B composite material were obtained using three accelerated test methods at elevated temperatures. Results of flexural creep tests using the dynamic mechanical analyzer (DMA) were compared with results of conventional tensile and compression creep tests. The procedures of the three test methods are described and the results are presented. Despite minor differences in the time shift factor of the creep compliance curves, the DMA results compared favorably with the results from the tensile and compressive creep tests. Some insight is given into establishing correlations between creep compliance in flexure and creep compliance in tension and compression. It is shown that with careful consideration of the limitations of flexure creep, a viable and reliable accelerated test procedure can be developed using the DMA to obtain the viscoelastic properties of composites in extreme environments.

Abdel-Magid, Becky M.↗