Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLTAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Vertical GaN Superjunction Diode on Sapphire with Kilovolt Dynamic Breakdown Voltage

The development of superjunction structures for use in vertical wide bandgap power devices promise to break the 1-D material limits. Additionally, the possibility of utilizing heteroepitaxial GaN-on-Sapphire wafer for vertical devices can significantly trim the material and device cost. This work introduces a quasi-vertical GaN-on-Sapphire superjunction PN diode design utilizing sputtered p-NiO on the etched GaN fins for superjunction formation. DC breakdown voltage is shown to vary with superjunction charge imbalance and significantly exceed the expected 1-D planar limit of 350V given the epilayer design used. A maximum breakdown voltage of 840 V is extracted for near charge balance conditions limited by leakage current. Dynamic breakdown of the device is characterized as a function of reverse voltage slew rate. A maximum dynamic breakdown voltage of 1160 V under a reverse voltage slew rate of 2000 V/μs is found.

Porter, Matthew↗

Adaptive Voltage Regulation for Solar Power Inverters on Distribution Systems

The most recent version of IEEE 1547 has incorporated four reactive power control modes, including constant power factor, voltage-reactive power (Volt-Var), active power-reactive power and constant reactive power. These modes are specified to be mutually exclusive, and they don’t include every smart inverter function proposed by industry collaboration. In earlier work, we found that Volt-Var settings could be optimized but were sensitive to changes in the normal grid voltage. This sensitivity can be mitigated by combining Volt-Var with dynamic reactive current (DRC), but neither DRC nor combined modes appear in IEEE 1547. One problem with Volt-Var is the default dead-band; it mitigates the sensitivity to setpoint, but also limits the effectiveness in managing voltage fluctuations. There has been continued interest in tuning smart inverter functions locally, and in combining central with local control, but this process still requires extensive simulations. The goal is to find a default inverter setting that will effectively mitigate voltage fluctuations even as grid conditions change. It must be compatible with the current version of IEEE 1547. It should also be compatible with advanced control methods when available. Otherwise, it should not require communications, detailed engineering studies or field commissioning of custom settings. This would facilitate the integration of distributed solar in larger amounts. Adaptive voltage regulation (AVR) is a Volt-Var implementation, but with “autonomously adjusting” setpoint as described below Table 8 in IEEE 1547. Through simulation of a test system in OpenDSS, it was shown that AVR having a high gain and a time constant of 300 seconds could work well in any location. This mode and setting should be considered for a new universal default setting on smart inverters.

McDermott, Thomas E.↗

Topology-Aware Reinforcement Learning for Voltage Control: Centralized and Decentralized Strategies

Volt-VAR control (VVC) methods based on deep reinforcement learning (DRL) can effectively control distribution grid voltage and minimize power loss by implementing corrective and preventive control measures on the reactive power output of inverter-based distributed energy resources (DERs). However, model-free DRL-based VVC approaches usually cannot capture the important topological feature of the power system since they use a fully-connected network (FCN) to deliver the action. Therefore, this paper proposes a graph convolutional network (GCN)-based DRL approach that can employ the topological information of the network to take better control action for regulating the voltage. Our implementation allows for both centralized and decentralized configurations, utilizing a single agent and multiple agents respectively. Although the centralized GCN-based DRL approach has its advantages of minimizing voltage fluctuation and power loss, it is not suitable for large scale power systems due to its challenges in terms of scalability, computation speed and potential single points of failure. Therefore, these problems can be resolved using the decentralized GCN-based DRL approach. Moreover, to ensure the safe operation of the model, our proposed approach incorporates an exponential barrier function while formulating the reward function for each agent. To validate performance of the proposed approaches, the proposed model is tested on modified IEEE test systems and the performances are measured in terms on voltage fluctuation reduction, minimization of power loss and computational speed. Finally, the results show that the proposed topology-aware approach outperforms the FCN-based DRL approach in terms of reducing voltage fluctuation and minimizing power loss of the network. Moreover, it is shown that the decentralized GCN-based DRL has faster computational speed than other approaches.

42 ENGINEERING↗

Bounded Universal Droop Control to Enable the Operation of Power Inverters Under Some Abnormal Conditions and Maintain Voltage and Frequency Within Predetermined Ranges

The universal droop control (UDC) can be applied to power inverters having an impedance angle between -pi/2 rad and pi/2 rad to achieve voltage and frequency regulation and accurate proportional power sharing without the need of knowing the type or value of impedance. However, there is an increasing need for voltage and frequency regulation within predetermined ranges even under some abnormal conditions, such as overloading, sensor faults, and large set-point changes, etc. In this paper, a bounded nonlinear dynamics is introduced into the UDC to ensure that the voltage and frequency can always stay within predetermined ranges under normal and some abnormal conditions, up to hardware limits when current protection needs to be triggered. As a result, the proposed controller can extend the operational range of power inverters in terms of voltage and frequency regulation to cover different scenarios. More importantly, the ranges for both voltage and frequency can be chosen independently from each other. Since the original structure of the UDC is kept in the proposed controller, the properties of the UDC, such as without the need of knowing the type or value of impedance, are well maintained. Furthermore, the closed-loop stability of the system is established via the Lyapunov method. Extensive simulation and experimental results are presented to validate the effectiveness of the proposed controller.

14 SOLAR ENERGY↗

Reduced Common-Mode Voltage PWM Scheme for Full-SiC Three-Level Uninterruptible Power Supply With Small DC-Link Capacitors

In this article, a pulsewidth modulation (PWM) scheme for three-level full-SiC uninterruptible power supplies is developed to achieve a high power density. Two key passive components are selected for size reduction of the ac-ac stage: common-mode (CM) EMI filter, and dc-link capacitors. To reduce the CM noise, a new vector combination is proposed based on synchronous switching among three-phases. The proposed combinations align CM voltage (CMV) to be a single pulse per switching period. Owing to the simple shape, CMV cancellation between a three-level rectifier and inverter can be maximally utilized. A transition between the three combinations can control the drift of neutral point voltage. An equivalent carrier-based implementation is developed. Second, a simple algorithm to compensate neutral point voltage fluctuation is proposed both for differential mode (DM) and CM output voltage. Low-order harmonics on three-phase currents and an additional high-frequency CM noise by misaligned switching instant can be eliminated. The proposed compensation can be implemented by a simple correction on carrier slopes and injected zero-sequence voltage. The proposed PWM scheme is verified with 20-kW full-SiC UPS switching at 60 kHz with 140 μF dc-link capacitors.

42 ENGINEERING↗

An Investigation into High Voltage Spiral Generators Utilizing Thyristor Input Switches

High voltage nanosecond pulses are widely used in scientific research, but their wider adoption in industry requires compact, cost effective and easy to use generators to be developed. This paper presents modelling and experimental investigations into one method of producing such pulses – a spiral generator with a solid-state, thyristor-based input switch. It includes how the pulses are formed within the spiral, why a high speed input switch is required, how the geometry of the spiral dictates its output characteristics, and the effects of different loads. Using thyristors, often connected in series to increase the operating voltage of the spiral, enables the spiral generators to have low jitter, high repetition rate, and long lifetime. Modelling of the circuit used a combination of telegraph equations to account for the wave propagation along the spiral and a lumped circuit exchanging charge between the spiral, the input switch, and the load. The model is verified by detailed experimental results with the relative error being < 10% in most cases. Here, the output voltage pulse was often observed to have an initial peak of much lower magnitude than the subsequent peak(s) – which can only be fully explained by considering wave propagation effects. Lower input switch inductance, shorter switching time, larger mean diameter of the spiral, and increasing the width of the copper tape that makes up the spiral can all increase the voltage multiplication efficiency. Though increasing the number of turns that make up the spiral can increase the output voltage, it can also lower the multiplication efficiency. By understanding the effects of different geometries the spiral can be optimized to drive different loads - three applications of such spiral generators are then presented: pulses with 10 kV amplitude and 10 kHz repetition rate for driving DBD plasma, pulses with amplitude of 10 kV and 10 kV/ns rising rate for triggering of advanced solid state switches, and pulses with -50 kV amplitude and 50 ns rising time for triggering high current gas switches through field distortion.1 Index Terms—spiral generator, nanosecond pulses, telegraph equations, series-connected thyristor module, pulse forming process

42 ENGINEERING↗

Bi-Level Volt-VAR Optimization to Coordinate Smart Inverters with Voltage Control Devices

Conservation voltage reduction (CVR) uses voltage control to reduce customer power demand and help improve the operational efficiency of the electric power distribution system. With the advent of advanced distribution management systems (ADMS), the underlying data and control-rich platform can be utilized to enable a centralized Volt-VAR optimization (VVO) scheme that includes smart inverter controls along with legacy voltage control devices such as voltage regulators and capacitor banks to ensure a maximum CVR benefit. The objective of this paper to present a VVO approach that controls system’s legacy voltage control devices and coordinates their operation with smart inverter control. An optimal power flow (OPF) formulation is proposed by developing linear and nonlinear power flow approximations for a three-phase unbalanced electric power distribution system. A bi-level VVO approach is proposed where, Level-1 optimizes the control of legacy devices and smart inverters using a linear approximate three-phase power flow. In Level-2, the control parameters for smart inverters are adjusted to obtain an optimal and feasible solution by solving the approximate nonlinear OPF model. Level-1 is modeled as a Mixed Integer Linear Program (MILP) while Level-2 as a Quadratically Constrained Quadratic Program (QCQP). The proposed approach is validated using IEEE test cases and the results demonstrate the applicability of the framework in achieving the CVR objective.

Jha, Rahul Ranjan↗

Coordinated Use of Smart Inverters with Legacy Voltage Regulating Devices in Distribution Systems with High Distributed PV Penetration — Increase CVR Energy Savings

This paper studies the coordinated use of smart inverters with legacy voltage regulating devices to help increase the energy savings from conservation voltage reduction (CVR) in distribution systems with high photovoltaic penetration. Two voltage optimization algorithms are developed to evaluate the CVR benefit by considering two types of smart inverter functions: aggregated reactive power control and autonomous volt/VAR control. In each algorithm, smart inverters are coordinately controlled with the operation of legacy voltage regulating devices including load tap changers and capacitor banks. Both algorithms are tested on representative utility distribution system models. In conclusion, simulation results demonstrate that the proposed algorithms can achieve around 1.8-3.6% energy savings when only using legacy voltage regulating devices and an additional 0.3-0.9% when adding smart inverters.

14 SOLAR ENERGY↗

Verification of a novel method for tube voltage constancy measurement of orthovoltage x-ray irradiators

Purpose: For orthovoltage x-ray irradiators, the tube voltage is one of the most fundamental system parameters as this directly relates to the dosimetry in radiation biology studies; however, to the best of our knowledge, there is no commercial portable quality assurance (QA) tool to directly test the constancy of the tube voltage greater than 160 kV. The purpose of this study is to establish the Beam Quality Index (BQI), a quantity strongly correlated to the tube voltage, as an alternative parameter for the verification of the tube voltage as part of the QA program of orthovoltage x-ray irradiators. Methods: A multipurpose QA meter and its associated data acquisition software were used to customize the measurement parameters to measure the BQI and collect its time-plot. BQI measurements were performed at 320 kV with four filtration levels on three orthovoltage x-ray irradiators of the same model, one of which had been recently energy-calibrated at the factory. Results: For each of the four filtration levels, the measured BQI values were in good agreement (<5%) between the three irradiators. BQI showed filtration-specificity, possibly due to the difference in beam quality. Conclusions: The BQI has been verified as a feasible alternative for monitoring the constancy of the tube voltage for orthovoltage irradiators. The time-plot of BQI offers information on the behavior of beam energy at different phases of the irradiation time line. In addition, this would provide power supply performance characteristics from initial ramp-up to plateau, and finally, the sharp drop-off at the end of the exposure.

60 APPLIED LIFE SCIENCES↗

Technical Note: Procedure for the calibration and validation of kilo-voltage cone-beam CT models

Purpose: The aim of this work is to propose a general and simple procedure for the calibration and validation of kilo-voltage cone-beam CT (kV CBCT) models against experimental data. Methods: The calibration and validation of the CT model is a two-step procedure: the source model then the detector model. The source is described by the direction dependent photon energy spectrum at each voltage while the detector is described by the pixel intensity value as a function of the direction and the energy of incident photons. The measurements for the source consist of a series of dose measurements in air performed at each voltage with varying filter thicknesses and materials in front of the x-ray tube. The measurements for the detector are acquisitions of projection images using the same filters and several tube voltages. The proposed procedure has been applied to calibrate and assess the accuracy of simple models of the source and the detector of three commercial kV CBCT units. If the CBCT system models had been calibrated differently, the current procedure would have been exclusively used to validate the models. Several high-purity attenuation filters of aluminum, copper, and silver combined with a dosimeter which is sensitive to the range of voltages of interest were used. A sensitivity analysis of the model has also been conducted for each parameter of the source and the detector models. Results: Average deviations between experimental and theoretical dose values are below 1.5% after calibration for the three x-ray sources. The predicted energy deposited in the detector agrees with experimental data within 4% for all imaging systems. Conclusions: The authors developed and applied an experimental procedure to calibrate and validate any model of the source and the detector of a CBCT unit. The present protocol has been successfully applied to three x-ray imaging systems. The minimum requirements in terms of material and equipment would make its implementation suitable in most clinical environments.

60 APPLIED LIFE SCIENCES↗

Development of Discharge in a Saline Solution at Near-Threshold Voltages

The development of a discharge in a point−plane gap filled with a saline solution with a salt content of 3% was studied experimentally. The duration of the voltage pulse applied to the gap was about 2 ms. Data are presented on the formation dynamics of gas microcavities at near-threshold voltages at which gas-discharge plasma appears in some microcavities. The cavities are conglomerates of microbubbles with a typical size of ≈100 μm. At the threshold voltage (≈750 V), the active electrode is covered with a gas layer and the gap voltage is in fact applied to this layer, which leads to the development of discharges in individual microbubbles. In this case, the discharge operates in the form of short current pulses. The number of microcavities filled with plasma increases as the voltage grows above the threshold value. At the plasma boundary, new microbubbles are formed, in which discharges are ignited. As a result, the plasma front propagates from the active electrode into the gap with a characteristic velocity of 10{sup 3} cm/s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of a Novel In-Situ Converted Additive for High Voltage Li-ion Pouch Cells

In search for new classes of additives for high voltage NMC/graphite lithium-ion cells, the precursor additive bis(trimethylsilyl) malonate (bTMSM) is shown to be activated via a spontaneous reaction with LiPF 6 and LiBF 4 salts in carbonate-based electrolyte to form lithium tetrafluoro(malonato)phosphate (LiTFMP), and lithium difluoro(malonato)borate (LiDFMB), respectively. The reaction schemes and rates were studied via NMR spectroscopy and GCMS. The effects of LiTFMP and LiDFMB on high voltage electrochemical performance were then examined up to 4.5 V in Li[Ni 0.4 Mn 0.4 Co 0.16 ]O 2 (NMC442)/graphite and Li[Ni 0.6 Mn 0.4 Co 0.0 ]O 2 (NMC/640)/graphite pouch cells using aggressive voltage-hold cycling, long-term charge/discharge cycling, storage experiments, electrochemical impedance spectroscopy, and gas evolution measurements. While in situ converted additives suffer from gassing issues due to the presence of trimethylfluorosilane (TMSF) gas, a side product of the in situ reaction of bTMSM with LiPF 6 , the cycling and storage capability for the activated additives under study shows competitive performance and controlled impedance when compared to other well-known high voltage additives. Micro X-ray fluorescence spectroscopy (μXRF) confirmed that LiTFMP successfully minimizes the rate of transition metal deposition on the surface of graphite apparently by forming a protective agent at the cathode surface, hence allowing for improved cycling performance at high voltages.

25 ENERGY STORAGE↗

Impact of Electrolyte Additives on the Lifetime of High Voltage NMC Lithium-Ion Pouch Cells

This work involves improving the lifetime of lithium-ion cells during high voltage cycling using electrolyte additives. Three generations of electrolyte additives were investigated and screened in NMC442/graphite pouch cells using a 24 h voltage-hold protocol at 40 degrees C to accelerate oxidative reactions occurring at 4.4 V. Once promising additives and combinations were identified, they were then tested in cobalt-free NMC640/graphite cells for long-term cycling to upper cutoff voltages of 4.3, 4.4, and 4.5 V at temperatures of 20, 40, and 55 degrees C. Degradation mechanisms were probed using dV/dQ analysis, micro-X-ray fluorescence spectroscopy, and electrochemical impedance spectroscopy. The primary failure mode of cells held at high voltages is due to increase in cell impedance, which is correlated to the dissolution of transition metals, specifically manganese, originating from the positive electrode. We believe this dissolution is presumably due to the formation of a high impedance rock salt surface layer on the NMC positive electrode particles. Such deleterious outcomes can be limited by selecting an appropriate electrolyte additive package. It is hoped that this paper can provide a starting point for developing NMC Li-ion cells that can operate to voltages as high as 4.4 V and still display long lifetimes.

Azam, Saad↗

Stability of Li- and Mn-Rich Layered-Oxide Cathodes within the First-Charge Voltage Plateau

Li and Mn rich layered oxides xLi 2 MnO 3 •(1-x)LiMO 2 enable high capacity and energy density Li-ion batteries, but undergo structural transformations during the first charge that degrade their performance, and result in Voltage Fade upon cycling. First-principles density-functional-theory simulations reveal atomic transformations that occur in the bulk during the first charge. The simulations and experiment (particularly XRD) show that the O and Mn sublattices remain intact during the early part of the voltage plateau, and significant transformations occur only well into the voltage plateau, with perhaps close to half of the Li in the Li 2 MnO 3 domains removed. That Voltage Fade is actually observed experimentally for a first charge with only minimal activation (extending only slightly beyond the onset of the voltage plateau) may be a consequence of surface and interface instabilities. Implications for the achievement of high energy-density, low-fade battery operation are discussed.

25 ENERGY STORAGE↗

Photovoltaic Impact Assessment of Smart Inverter Volt-VAR Control on Distribution System Conservation Voltage Reduction and Power Quality

This report presents an impact assessment study of distributed photovoltaic (PV) with smart inverter Volt-VAR control on conservation voltage reduction (CVR) energy savings and distribution system power quality. CVR is a methodology of flattening and lowering a distribution system voltage profile in order to conserve energy. Traditional CVR relies on operating utility voltage regulators and switched capacitors. However, with the increased penetration of distributed PV systems, smart inverters provide the new opportunity to control local voltage and power factor by regulating the reactive power output, leading to a potential increase in CVR energy savings. This report proposes a methodology to implement CVR scheme by operating voltage regulators, capacitors, and autonomous smart inverter Volt-VAR control in order to achieve increased CVR benefit. Power quality is an important consideration when operating a distribution system, especially when implementing CVR. It is easy to measure the individual components that make up power quality, but a comprehensive method to incorporate all of these values into a single score has yet to be undertaken. As a result, this report proposes a power quality scoring mechanism to measure the relative power quality of distribution systems using a single number, which is aptly named the 'power quality score' (PQS). Both the CVR and PQS methodologies were applied to two distribution system models, one obtained from the Hawaiian Electric Company (HECO) and another obtained from Pacific Gas and Electric (PG&E). These two models were converted to the OpenDSS platform using previous model conversion tools that were developed by NREL. Multiple scenarios including various PV penetration levels and smart inverter densities were simulated to analyze the impact of smart inverter Volt-VAR support on CVR energy savings and feeder power quality. In order to analyze the CVR benefit and PQS, an annual simulation was conducted for each scenario.

14 SOLAR ENERGY↗

Advanced Inverter Voltage Controls: Simulation and Field Pilot Findings

This report describes work performed by the Hawaiian Electric Companies and the National Renewable Energy Laboratory (NREL) to model and simulate advanced inverter grid-support functions and to validate and expand on those simulations through a field pilot study. This work builds on earlier research, referred to as the Voltage Regulation Operational Strategies study. The objective of both is to investigate functionalities available in most photovoltaic (PV) inverters to modulate active and reactive power autonomously based on local voltage measurements for the purpose of mitigating off-nominal grid voltage conditions. Specifically of interest are volt/volt-ampere reactive (VAR) control and volt/watt control, the effect of those functions on quasi-steady-state feeder voltages, and the impact of the functions on PV energy production. Because volt/VAR and volt/watt control autonomously adjust inverter output based on local conditions without requiring communication with any other devices, they are good candidates to increase PV hosting capacity when it is limited by voltage constraints in a feeder with very large numbers of PV systems.

14 SOLAR ENERGY↗

High Voltage Modeling and Testing of Transformer, Line Interface Devices, and Bulk System Components Under Electromagnetic Pulse, Geomagnetic Disturbance, and other Abnormal Transients

This project aims at quantitatively analyzing possible knowledge gaps related to the risk of Electromagnetic Pulse (EMP) impact on high-voltage, power transformers (transmission-class), that represent the most critical power grid assets. In relation to the electric infrastructure, some past studies indicate that the grid is overall fairly robust and resilient against most EMP threats. This assessment stems, in part, from estimates of the peak voltage that can be induced on a transmission power line for a nominal EMP fast-transient, compared with the typically very high basic insulation level that is featured by the high-voltage infrastructure. The project provides additional insight toward a more comprehensive risk evaluation of the grid EMP and Geomagnetic Disturbances (GMD) vulnerabilities. This work is aligned with the U.S. Dept. of Energy current research thrust in support of the development of a highly secure and resilient power infrastructure. Project milestones have been devised to address the fundamental technical issues in support of protection of large power transformer against EMP threats. More specifically, this project included parallel research tasks focused on the following topics: analysis of EMP-induced, fast-transient, current and voltages on a variety of power line configurations and EMP impact scenarios, detailed characterization of EMP damage potential due to the voltage surge, from the impact on the power line, to the transformer windings, GMD and EMP slow transients and impact from harmonics generation and reactive power flow on a complex grid layout, and identification of risk mitigation paths, with emphasis on GIC damage prevention for large power transformers, and on impact protection options from a grid stability perspective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization of DARHT Axis 1 Injector Voltage

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces a 20- MeV, 2-kA, 80-ns-FWHM electron beam. The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injector electron beam energy. The technique for time resolved measurement of the electron beam energy using electron Permanent Magnet Spectrometer (ePMSpec) has been developed. The electron energy then is used to infer the voltage produced by the injector pulsed power. The injector pulsed power of DARHT I consists of a 1.5-MV, glycol-insulated Blumlein that is pulsecharged by a step-up transformer and switched by four, laser-triggered spark gaps. A series of increasing impedance transmission lines are used to transform the output voltage of the Blumlein to a maximum of 3.8MV at the diode. Figure 1a shows a graphic of the Axis-1 prime power tank, Blumlein and downstream transmission lines. The injector pulse power is designed to produce voltage on a velvet cathode located in the vacuum vessel. The specifications of the voltage-pulse flat-top over 60ns is +/-1%. A key element in the high-voltage circuit is the ethylene glycol Blumlein. The outer volume, adjacent to the laser triggered switches of the Blumlein, is a peaking capacitor. This is an independent volume that contains a mixture of ethylene glycol and water to make it an adjustable capacitor of 380 to 750 pF.

43 PARTICLE ACCELERATORS↗