Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VISUAL DISPLAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

A Visual Editor in Java for View

In this project we continued the development of a visual editor in the Java programming language to create screens on which to display real-time data. The data comes from the numerous systems monitoring the operation of the space shuttle while on the ground and in space, and from the many tests of subsystems. The data can be displayed on any computer platform running a Java-enabled World Wide Web (WWW) browser and connected to the Internet. Previously a special-purpose program bad been written to display data on emulations of character-based display screens used for many years at NASA. The goal now is to display bit-mapped screens created by a visual editor. We report here on the visual editor that creates the display screens. This project continues the work we bad done previously. Previously we had followed the design of the 'beanbox,' a prototype visual editor created by Sun Microsystems. We abandoned this approach and implemented a prototype using a more direct approach. In addition, our prototype is based on newly released Java 2 graphical user interface (GUI) libraries. The result has been a visually more appealing appearance and a more robust application.

Stansifer, Ryan↗

Self-Management of Patient Body Position, Pose, and Motion Using Wide-Field, Real-Time Optical Measurement Feedback: Results of a Volunteer Study

Purpose: We present the results of a clinical feasibility study, performed in 10 healthy volunteers undergoing a simulated treatment over 3 sessions, to investigate the use of a wide-field visual feedback technique intended to help patients control their pose while reducing motion during radiation therapy treatment. Methods and Materials: An optical surface sensor is used to capture wide-area measurements of a subject's body surface with visualizations of these data displayed back to them in real time. In this study we hypothesize that this active feedback mechanism will enable patients to control their motion and help them maintain their setup pose and position. A capability hierarchy of 3 different level-of-detail abstractions of the measured surface data is systematically compared. Results: Use of the device enabled volunteers to increase their conformance to a reference surface, as measured by decreased variability across their body surfaces. The use of visual feedback also enabled volunteers to reduce their respiratory motion amplitude to 1.7 ± 0.6 mm compared with 2.7 ± 1.4 mm without visual feedback. Conclusions: The use of live feedback of their optically measured body surfaces enabled a set of volunteers to better manage their pose and motion when compared with free breathing. The method is suitable to be taken forward to patient studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Changes in the dark focus of accommodation associated with simulator sickness

The relationship between the dark focus of accommodation and simulator sickness, a form of motion sickness, was examined in three experiments. In Experiment 1, dark focus was measured in 18 college students in a laboratory setting before and after they viewed a projected motion scene depicting low altitude helicopter flight. In Experiments 2 and 3, dark focus was measured in pilots (N = 16 and 23, respectively) before and after they 'flew' in moving-base helicopter flight simulators with optical infinity CRT visual systems. The results showed that individuals who experienced simulator sickness had either an inward (myopic) change in dark focus (Experiments 1 and 3) or attenuated outward shifts in dark focus (Experiment 2) relative to participants who did not get sick. These results are consonant with the hypothesis that parasympathetic activity, which may be associated with simulator sickness, should result in changes in dark focus that are in a myopic direction. Night vision goggles, virtual environments, extended periods in microgravity, and heads-up displays all produce related visual symptomatology. Changes in dark focus may occur in these conditions, as well, and should be measured.

Fowlkes, Jennifer E.↗

Effect of image tilt of a virtual image display on simulated transport touchdown performance

An evaluation of the visual effect of image tilt of a refractive lens display system is presented. The system was used to present a rudimentary computer generated out the window scene to the pilot of a flight simulator during approach, flare, and touchdown. Comparisons are made of sink rate at touchdown and performances for untilted and tilted displays. Sixty four landings with each condition for a total of 128 touchdowns were made by 3 subjects. Performance measures, such as the flare and touchdown footprints, were recorded and analyzed. The visual effect of the image tilt was investigated for a terrain model board scene.

Parrish, R. V.↗

MO-DE-BRA-04: Hands-On Fluoroscopy Safety Training with Real-Time Patient and Staff Dosimetry

Purpose: Fluoroscopically guided interventions (FGI) are routinely performed across many different hospital departments. However, many involved staff members have minimal training regarding safe and optimal use of fluoroscopy systems. We developed and taught a hands-on fluoroscopy safety class incorporating real-time patient and staff dosimetry in order to promote safer and more optimal use of fluoroscopy during FGI. Methods: The hands-on fluoroscopy safety class is taught in an FGI suite, unique to each department. A patient equivalent phantom is set on the patient table with an ion chamber positioned at the x-ray beam entrance to the phantom. This provides a surrogate measure of patient entrance dose. Multiple solid state dosimeters (RaySafe i2 dosimetry systemTM) are deployed at different distances from the phantom (0.1, 1, 3 meters), which provide surrogate measures of staff dose. Instructors direct participating clinical staff to operate the fluoroscopy system as they view live fluoroscopic images, patient entrance dose, and staff doses in real-time. During class, instructors work with clinical staff to investigate how patient entrance dose, staff doses, and image quality are affected by different parameters, including pulse rate, magnification, collimation, beam angulation, imaging mode, system geometry, distance, and shielding. Results: Real-time dose visualization enables clinical staff to directly see and learn how to optimize their use of their own fluoroscopy system to minimize patient and staff dose, yet maintain sufficient image quality for FGI. As a direct result of the class, multiple hospital departments have implemented changes to their imaging protocols, including reduction of the default fluoroscopy pulse rate and increased use of collimation and lower dose fluoroscopy modes. Conclusion: Hands-on fluoroscopy safety training substantially benefits from real-time patient and staff dosimetry incorporated into the class. Real-time dose display helps clinical staff visualize, internalize, and ultimately utilize the safety techniques learned during the training. RaySafe/Unfors/Fluke lent us a portable version of their RaySafe i2 Dosimetry System for 6 months.

60 APPLIED LIFE SCIENCES↗

Design considerations for a space database

Part of the information used in a real-time simulator is stored in the visual database. This information is processed by an image generator and displayed as a real-time visual image. The database must be constructed in a specific format, and it should efficiently utilize the capacities of the image generator that is was created for. A visual simulation is crucially dependent upon the success with which the database provides visual cues and recognizable scenes. For this reason, more and more attention is being paid to the art and science of creating effective real-time visual databases. Investigated here are the database design considerations required for a space-oriented real-time simulator. Space applications often require unique designs that correspond closely to the particular image-generator hardware and visual-database-management software. Specific examples from the databases constructed for NASA and its Evans and Sutherland CT6 image generator illustrate the various design strategies used in a space-simulation environment. These database design considerations are essential for all who would create a space database.

Moss, Lance M.↗

Constellation Visualization Tool Set-Up

This presentation and demonstration help missions understand how to use the Constellation Coordination System (CCS) to obtain the products necessary to display spacecraft in the Constellation Visualization Tool (CVT) via subscriptions. After setting up product subscriptions the demonstration will highlight the new features of CVT and answer audience questions on the running of CVT in their own centers.

Constellation Visualization Tool↗

A proposal for preprocessing, reduction, and selection of visual information in airborne flight simulation

A noncritical empirical detail-by-detail transformation of environmental information into flight display by purely physical methods characterizes the textured visual simulation as indiscernibly identical with the real scene. This method uses image storage, readout, image transformation, and graphic display to present a true color visual flight image to the pilot onboard aircraft in a purely electronic manner, employing analog-hybrid techniques.

Gaertner, K.↗

iSpy: A powerful and lightweight event display

iSpy is a general-purpose event data and detector visualization program that was developed as an event display for the CMS experiment at the LHC and has seen use by the general public and teachers and students in the context of education and outreach. Central to the iSpy design philosophy is ease of installation, use, and extensibility. The application itself uses the open-access packages Qt4 and Open Inventor and is distributed either as a fully-bound executable or a standard installer package: one can simply download and double-click to begin. Mac OSX, Linux, and Windows are supported. iSpy renders the standard 2D, 3D, and tabular views, and the architecture allows for a generic approach to production of new views and projections. iSpy reads and displays data in the ig format: event information is written in compressed JSON format files designed for distribution over a network. This format is easily extensible and makes the iSpy client indifferent to the original input data source. The ig format is the one used for release of approved CMS data to the public.

Alverson, G.↗

Predictive capability of a leaf optical meter for determining leaf pigment status during senescence

We conducted an experiment to assess the predictive capability of a leaf optical meter for determining leaf pigment status of Acer mono Maxim., A. ginnala Maxim., Quercus mongolica Fisch., and Cornus alba displaying a range of visually different leaf colors during senescence. Concentrations of chlorophyll (Chl) a, Chl b, and total Chl decreased while the concentration of carotenoids (Car) remained relatively static for all species as leaf development continued from maturity to senescence. C. alba exhibited the lowest average concentration of total Chl, Chl a, and Car, but the highest relative anthocyanin concentration, while Q. mongolica exhibited the highest total Chl, Chl b, and the lowest relative anthocyanin concentration. A. mono exhibited the highest Chl a and Car concentrations. The relationships between leaf pigments and the values measured by the optical meter generally followed an exponential function. The strongest relationships between leaf pigments and optical measurements were for A. mono, A. ginnala, and Q. mongolica (R 2 ranged from 0.64 to 0.95), and the worst relationship in C. alba (R 2 ranged from 0.13 to 0.67). Moreover, optical measurements were more strongly related to Chl a than to Chl b or total Chl. Optical measurements were not related to Car or relative anthocyanin concentrations. We predicted that weak relationships between leaf pigments and optical measurements would occur under very low Chl concentrations or under very high anthocyanin concentrations; however, these factors could not explain the weak relationship between Chl and optical measurements observed in C. alba. Overall, our results indicated that optical meter can accurately estimate leaf pigment concentrations during leaf senescence — a time when pigment concentrations are dynamically changing — but that the accuracy of the estimate varies across species. Future research should investigate how species-specific leaf traits may influence the accuracy of pigment estimates derived from optical meters.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a video image-based QA system for the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system

Purpose: To develop and evaluate a new video image-based QA system, including in-house software, that can display a tracking state visually and quantify the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system. Methods: Sixteen trajectories in six patients with pulmonary cancer were obtained with the ExacTrac in the Vero4DRT system. Motion data in the cranio–caudal direction (Y direction) were used as the input for a programmable motion table (Quasar). A target phantom was placed on the motion table, which was placed on the 2D ionization chamber array (MatriXX). Then, the 4D modeling procedure was performed on the target phantom during a reproduction of the patient’s tumor motion. A substitute target with the patient’s tumor motion was irradiated with 6-MV x-rays under the surrogate infrared system. The 2D dose images obtained from the MatriXX (33 frames/s; 40 s) were exported to in-house video-image analyzing software. The absolute differences in the Y direction between the center of the exposed target and the center of the exposed field were calculated. Positional errors were observed. The authors’ QA results were compared to 4D modeling function errors and gimbal motion errors obtained from log analyses in the ExacTrac to verify the accuracy of their QA system. The patients’ tumor motions were evaluated in the wave forms, and the peak-to-peak distances were also measured to verify their reproducibility. Results: Thirteen of sixteen trajectories (81.3%) were successfully reproduced with Quasar. The peak-to-peak distances ranged from 2.7 to 29.0 mm. Three trajectories (18.7%) were not successfully reproduced due to the limited motions of the Quasar. Thus, 13 of 16 trajectories were summarized. The mean number of video images used for analysis was 1156. The positional errors (absolute mean difference + 2 standard deviation) ranged from 0.54 to 1.55 mm. The error values differed by less than 1 mm from 4D modeling function errors and gimbal motion errors in the ExacTrac log analyses (n = 13). Conclusions: The newly developed video image-based QA system, including in-house software, can analyze more than a thousand images (33 frames/s). Positional errors are approximately equivalent to those in ExacTrac log analyses. This system is useful for the visual illustration of the progress of the tracking state and for the quantification of positional accuracy during dynamic tumor tracking irradiation in the Vero4DRT system.

60 APPLIED LIFE SCIENCES↗

Dirty Word Scanner

SAND2025-09142O Dirty Word Scanner helps prevent the accidental inclusion of sensitive terms by scaning files in repositories to catch "dirty words" before they are committed. While there are existing solutions focused on passwords and API keys, this tool offers additional features tailored to specific security needs. It will function as a standalone tool, incorporating advanced capabilities from similar tools to provide a comprehensive solution. This tool can unpack HDF5 files and examine their contents. It can display image, audio, and visual files to the user and request a manual determination of whether they are safe. It can also detect arbitrary binary files and ask the user to verify that they're safe. The tool enables sophisticated whitelisting of strings and regular expressions for cases where a term is sensitive in certain contexts but not in others. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Gates, Jason [Sandia National Lab. (SNL-CA), Liver↗

OpenEIS. Developer Guide

The Department of Energy’s (DOE’s) Building Technologies Office (BTO) is supporting the development of an open-source software tool for analyzing building energy and operational data: OpenEIS (open energy information system). This tool addresses the problems of both owners of building data and developers of tools to analyze this data. Building owners and managers have data but lack the tools to analyze it while tool developers lack data in a common format to ease development of reusable data analysis tools. This document is intended for developers of applications and explains the mechanisms for building analysis applications, accessing data, and displaying data using a visualization from the included library. A brief introduction to the visualizations can be used as a jumping off point for developers familiar with JavaScript to produce their own. Several example applications are included which can be used along with this document to implement algorithms for performing energy data analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Reporting: Device Demonstration, Communication Protocols, and Codes and Standards

Energy reporting is the principle that all energy-using devices in buildings should be able to track their own energy use and report this to the local network. Energy reporting can provide building owners with easy access to highly granular energy use data. This report makes the case that energy reporting should become a free basic feature of all devices, and reports on a project intended to move us towards that goal. The project collected a set of demonstration devices with energy reporting features, including products that were modified by the project team or the manufacturer, or are already available for sale. To show these devices operating live at meetings and conferences, the team created a management system that queries the energy reporting devices for their data, stores the data, and displays it in compelling visualizations. The devices covered a wide range, including heating, ventilation, and air conditioning (thermostat and air purifier); lighting (individual bulb, task light, and auto-dimming overhead light); a vehicle charger; a water heater; electronics (notebook personal computer and universal serial bus charger); and three external meters (one integral with a dimming light switch). The demonstration uses a variety of communication protocols. The report reviews existing communication protocols that support energy reporting and describes how to use them with a proposed reference data model for energy reporting. It also assesses ways that energy codes and standards processes can be leveraged to drive energy reporting technology into the market. Energy reporting could ultimately save California on the order of 2.5 terawatt-hours per year and about $0.8 billion per year. Energy reporting is a highly practical technology with minimal (sometimes no) cost to consumers and manufacturers. This report discusses creation of the energy reporting devices themselves, analysis and recommendations for data models and protocols for energy reporting, and energy codes and standards implications of energy reporting technology. While energy reporting does not directly save energy, it provides information for better decision-making to save energy in changing equipment operation, maintenance, and replacement.

devices↗

Recent Advances in Display Media

Properties and imaging techniques of various display devices - computer directed visual flight control boards, integrated optical man machine systems, and electro-optical methods

Source record↗

A dual-loop model of the human controller in single-axis tracking tasks

A dual loop model of the human controller in single axis compensatory tracking tasks is introduced. This model possesses an inner-loop closure which involves feeding back that portion of the controlled element output rate which is due to control activity. The sensory inputs to the human controller are assumed to be system error and control force. The former is assumed to be sensed via visual, aural, or tactile displays while the latter is assumed to be sensed in kinesthetic fashion. A nonlinear form of the model is briefly discussed. This model is then linearized and parameterized. A set of general adaptive characteristics for the parameterized model is hypothesized. These characteristics describe the manner in which the parameters in the linearized model will vary with such things as display quality. It is demonstrated that the parameterized model can produce controller describing functions which closely approximate those measured in laboratory tracking tasks for a wide variety of controlled elements.

Hess, R. A.↗

An image-processing system applied to earth-resource imagery

The Harwell Image Processing System (HIPS) has been adapted for processing earth-resource imagery in either film or tape format. Data from film are obtained using a computer-controlled flying-spot scanner. Local rapid interactive processing is based on a PDP 11/20 minicomputer which has suitable display facilities for immediate visual appraisal of results and also a fast data link to an IBM 370/168 computer complex. An extensive subroutine library is being assembled for data preprocessing and feature extraction. This chapter includes a discussion of the basic principles of image analysis, a description of the HIPS system, and finally, for illustrative purposes, a description of several simple software routines.

Carter, P.↗