Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

ISS External Microorganisms: A Planetary Protection Payload Ready-for-Flight

Before NASA or COSPAR is able to set planetary protection requirements for crewed missions to locations like Mars there are a number of critical knowledge gaps that must be addressed (1). One of the most important knowledge gaps is an understanding of microbial leakage from crewed habitats and space suits. Current ECLSS (Environmental Control and Life Support System) and PLSS (Portable Life Support System) requirements do not include any provisions to control microbes that may escape along with vented or leaked gasses. The current generation of NASA space suits can leak at rates as high as 100 cm3/min. during nominal operation (2). ISS (International Space Station) intentionally vents atmospheric gases like CO2to maintain habitable conditions for the crew. Furthermore, every time an airlock is used for EVA (extravehicular activity) there is an accompanying release of internal atmosphere. Since it is not possible to sterilize a crewed mission, it is important that we understand what if any microbes are entrained in these vented and leaked products. It is also important to understand if these microbes can survive on exterior surfaces. Recent sampling of the Russian segments of ISS suggest that bacteria and fungi from inside ISS may be capable of surviving on external surfaces (3). NASA has developed an aseptic sampling tool for use during EVA and plans to collect samples from vents on ISS to build on these results. The results of this work will be used to develop planetary protection requirements for vented and leaked gasses from crewed volumes.

M S Bell↗

A Study of BWR Mark I Station Blackout Accident with GOTHIC Modeling

The overall objective of this study is to develop a high-fidelity simulation capability for the analysis of accident progression during Station Black-Out (SBO) scenario in Boiling Water Reactor (BWR) Mark I plant. The motivation is on predicting the effectiveness of containment venting within accident mitigation strategy and how to avoid core melt by choosing a proper time to initiate primary system venting. In this work, a GOTHIC model has been developed to support characterization of reactor safety systems performance and evaluation of the venting strategy. The GOTHIC model provides a seamless coupled simulation of the reactor coolant system and the containment system based on the design of the Peach Bottom-2 plant system. Efforts are also taken on the analysis for the primary system venting strategy. The safe time intervals (so-called “safe venting window”) to initiate the primary system depressurization in order to optimize the early cooling strategy by adding fire water and avoid core melt are also studied based on the heat removal capability (HRC) of the reactor vessel coolant. This concept is instructive for the operation of the safety systems during the SBO accident mitigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Energy storage device and related methods

The present disclosure relates to energy storage devices having: a sealed container configured to house a plurality of energy storage devices and enable electrical communication via terminals of the sealed container and a vent located on a periphery of the sealed container. The vent generally comprises a vent panel; a countersink located adjacent the vent panel; at least one score located in the countersink; a buckling initiator at least partially located on the countersink, where the buckling initiator is configured to intersect with the at least one score; and a hinge portion attached to the vent panel, where the hinge portion is positioned opposite the buckling initiator.

Jarvis, Glenn W.↗

Status Report on Ex-Vessel Coolability and Water Management

Specific to BWR plants, current accident management guidance calls for flooding the drywell to a level of approximately 1.2 m (4 feet) above the drywell floor once vessel breach has been determined. While this action can help to submerge ex-vessel core debris, it can also result in flooding the wetwell and thereby rendering the wetwell vent path unavailable. An alternate strategy is being developed in the industry guidance for responding to the severe accident capable vent Order, EA-13-109. The alternate strategy being proposed would throttle the flooding rate to achieve a stable wetwell water level while preserving the wetwell vent path. The overall objective of this work is to upgrade existing analytical tools (i.e. MELTSPREAD and CORQUENCH - which have been used as part of the DOE-sponsored Fukushima accident analyses) in order to provide flexible, analytically capable, and validated models to support the development of water throttling strategies for BWRs that are aimed at keeping ex-vessel core debris covered with water while preserving the wetwell vent path.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Safe, High Specific Energy & Power Lithium Ion Cell Designs

The higher energy content (265 Wh/kg, 725 Wh/L) of the newer cell designs from LG, Panasonic, and Samsung have made them susceptible to side wall ruptures (SWR) during thermal runaway, rather than venting through the intended vent path in the cell header. This is also due to higher reaction kinetics of the electrochemistry, thinner can walls, tight crimp enclosure of the cell header, and inadequate flow rate through the header vent. This effort determined that bottom vents and thicker cell can walls both are necessary for reducing the risk of SWR. Compelling evidence was obtained using novel test methods that included an on-demand internal short circuit device, high speed X-ray videography, and cell thermal runaway calorimetry.

side wall rupture↗

Building America Case Study: Field Testing an Unvented Roof with Fibrous Insulation and Tiles, Orlando, Florida

This research is a test implementation of an unvented tile roof assembly in a hot-humid climate (Orlando, FL; Zone 2A), insulated with air permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous unvented roof field work, it was theorized that a 'diffusion vent' (water vapor open, but air barrier 'closed') at the highest points in the roof assembly might allow for the wintertime release of moisture, to safe levels. The 'diffusion vent' is an open slot at the ridge and hips, covered with a water-resistant but vapor open (500+ perm) air barrier membrane. As a control comparison, one portion of the roof was constructed as a typical unvented roof (self-adhered membrane at ridge). The data collected to date indicate that the diffusion vent roof shows greater moisture safety than the conventional, unvented roof design. The unvented roof had extended winter periods of 95-100% RH, and wafer (wood surrogate RH sensor) measurements indicating possible condensation; high moisture levels were concentrated at the roof ridge. In contrast, the diffusion vent roofs had drier conditions, with most peak MCs (sheathing) below 20%. In the spring, as outdoor temperatures warmed, all roofs dried well into the safe range (10% MC or less). Some roof-wall interfaces showed moderately high MCs; this might be due to moisture accumulation at the highest point in the lower attic, and/or shading of the roof by the adjacent second story. Monitoring will be continued at least through spring 2016 (another winter and spring).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achievements and process improvements in processing transuranic waste at the TRU Waste Processing Center - 15488

Wastren Advantage, Inc., (WAI) is the DOE Prime contractor for the TRU Waste Processing Center (TWPC) located in Oak Ridge, TN. This paper highlights the TWPCs specific achievements and process improvements associated with both Contact (CH) and Remote Handled (RH), Transuranic (TRU) waste receipt processing and repackaging for disposal. The five key improvement areas and achievements include: - The TWPC installed, tested and operated successfully the Drum Venting System (DVS) to vent over-packed CH-TRU waste drums in several configurations including 55-gallon drums over-packed in 79 or 85-gallon drums. - A new Remote Drum Opener (RDO) system was designed, tested and placed in service to vent drums discovered in overpack boxes in the Box Breakdown Area and to vent overpack configurations that could not be handled in the standard DVS (e.g., 110 gallon overpacks and multiple drum configurations). - The Cask Processing Enclosure (CPE) approach to repackaging RH-TRU waste contained in concrete casks was developed and implemented - Hot Cell outage to incorporate planned equipment modifications and improvements to maintain processing rates. - To improve certification and segregation of CH-TRU from drums that meet Low Level Waste criteria for disposal at Nevada the TWPC added additional equipment/facilities for Non-Destructive Assay (NDA) and Real Time Radiography (RTR). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-Process Melt Separation of Depolymerized PET in PET/PE Blends for Upcycling via Twin-Screw Extrusion

Our previous work focused on depolymerizing polyethylene terephthalate (PET) in twin-screw extrusion, as part of a broader project to continuously separate PET from polyolefins in the melt. This study focused on linear low-density polyethylene (LLDPE) and PET films and the use of ethylene glycol (EG), diethylene glycol (DEG), triethylene glycol (TEG), and bis(2-hydroxyethyl) terephthalate (BHET) to depolymerize the PET in the extruder to levels above 90% Mw. In this work, the focus will shift to achieving separation of the two polymers in the twin-screw extruder, which is made possible due to a 90% reduction in the Mw of the PET, which caused a decrease of its viscosity by several orders of magnitude. Owing to the viscosity difference and pressure buildup in the die, the low-viscosity PET preferentially exited a degassing vent instead of going through the die. This is because the flow of the PET would travel through a non-pressure vent rather than through a high-pressure die. However, owing to the higher viscosity of the LLDPE, the pressure was too high to pass through such a small diameter vent hole. Supercritical CO 2 (SCCO 2 ) was used to assist in this extraction, but SCCO 2 negatively impacted the overall degree of separation. Through analysis of the separated materials, it was concluded that a high separation of the two materials was achieved. TGA and FTIR confirmed that the material separated from the vent was 100% PET. The material removed from the die was composed of 95% LLDPE and 5% PET.

36 MATERIALS SCIENCE↗

In‐Process Melt Separation of PE/PET Blends for Upcycling via Twin‐Screw Extrusion. Impact of Catalyst Reagents on PET Depolymerization

Part 1 of this work focused on depolymerizing polyethylene terephthalate (PET) in twin-screw extrusion, as part of a broader project to continuously separate PET from polyolefins in the melt. This study focused on linear low-density polyethylene (LLDPE) and PET films and the use of ethylene glycol (EG), diethylene glycol (DEG), triethylene glycol (TEG), and bis(2-hydroxyethyl) terephthalate (BHET) to depolymerize the PET in the extruder to levels above 90% Mw. In part 2, the focus will shift to achieving separation of the two polymers in the twin-screw extruder, which is made possible due to a 90% reduction in the Mw of the PET, which caused a decrease of its viscosity by several orders of magnitude. Owing to the viscosity difference and pressure buildup in the die, the low-viscosity PET preferentially exited a degassing vent instead of going through the die. This is because the flow of the PET would travel through a non-pressure vent rather than through a high-pressure die. However, owing to the higher viscosity of the LLDPE, the pressure was too high to pass through such a small diameter vent hole. Supercritical CO₂ (SCCO₂) was used to assist in this extraction, but SCCO₂ negatively impacted the overall degree of separation. Through analysis of the separated materials, it was concluded that a very high separation of the two materials was achieved. TGA and FTIR confirmed that the material separated from the vent was 100% PET. The material removed from the die was composed of 90% LLDPE and 10% PET.

36 MATERIALS SCIENCE↗

Modeling delayed thermal runaway in nitric acid-soaked cat litter mixed with radioactive waste

Thermal ignition of radioactive waste within a 55-gallon drum was simulated by using a pressure-dependent waste decomposition model (Hobbs et al. in Process Saf Environ Prot https://doi.org/10.1016/j.psep.2022.09.047, 2022) calibrated with data from full-scale drum experiments (Parker et al. in The thermolytic response of a surrogate RNS waste mixture at the drum scale. Los Alamos National Laboratory Report LA-UR-16-21760, 2016) and validated with experiments from multiple laboratories (Hobbs et al. in Thermal analysis of aged nitric acid-soaked kitty litter in TRU waste drums-23370.WM2023 Conference, Phoenix, AZ, 2023). The acceleration of nitric acid chemistry reacting with an organic cat litter leading to thermal ignition was likely triggered by a restricted vent in the drum. Here, we address whether the form of the rate equation in (Hobbs et al. in Process Saf Environ Prot https://doi.org/10.1016/j.psep.2022.09.047, 2022) is sufficient to extrapolate thermal ignition within aged drums of similar content that have been stored in Texas for over nine years by investigating four different reaction rate forms for waste decomposition. A critical reaction rate reduction analysis is performed on each of these models to determine if delayed thermal runaway within vented aged waste is possible after nine years. We found that a pressure-dependent first-order rate expression not only predicted the accidental ignition of the waste drum, but the form also matches multiple experiments from different laboratories. Even though the waste composition decreases over time, the model predicts that acceleration leading to thermal runaway is possible if the waste is confined, even after 9 years. In conclusion, waste containing oxidizers such as nitric acid should not be mixed with organic adsorbents, especially if the waste is confined.

cookoff↗

Measurement of advective soil gas flux: Results of field and laboratory experiments with CO2

We modified our multi-channel, steady-state flow-through (SSFT), soil-CO2 flux monitoring system to include an array of inexpensive pyroelectric non-dispersive infrared detectors for full-range (0-100%) coverage of CO2 concentrations without dilution, and a larger-diameter vent tube. We then conducted field testing of this system from late July through mid-September 2010 at the Zero Emissions Research and Technology (ZERT) project site located in Bozeman, MT, and subsequently, laboratory testing at the Pacific Northwest National Laboratory (PNNL) in Richland, WA using a flux bucket filled with dry sand. In the field, an array of twenty-five SSFT and three non-steady-state (NSS) flux chambers was installed in a 10x4 m area, the long boundary of which was directly above a shallow (2-m depth) horizontal injection well located 0.5 m below the water table. Two additional chambers (one SSFT and one NSS) were installed 10 m from the well for background measurements. Volumetric soil moisture sensors were installed at each SSFT chamber to measure mean levels in the top 0.15 m of soil. A total flux of 52 kg CO2 d-1 was injected into the well for 27 d and the efflux from the soil was monitored by the chambers before, during, and for 27 d after the injection. Overall, the results were consistent with those from previous years, showing a radial efflux pattern centered on a known “hot spot”, rapid responses to changes in injection rate and wind power, evidence for movement of the CO2 plume during the injection, and nominal flux levels from the SSFT chambers that were up to 6-fold higher than those measured by adjacent NSS chambers. Soil moisture levels varied during the experiment from moderate to near saturation with the highest levels occurring consistently at the hot spot. The effects of wind on measured flux were complex and decreased as soil moisture content increased. In the laboratory, flux bucket testing with the SSFT chamber showed large measured-flux enhancement due to the Venturi effect on the chamber vent, but an overall decrease in measured flux when wind also reached the sand surface. Flux-bucket tests at a high flux (comparable to that at the hot spot) also showed that the measured flux levels increase linearly with the chamber-flushing rate until the actual level is reached. At the SSFT chamber-flushing rate used in the field experiment the measured flux in the laboratory was only about a third of the actual flux. The ratio of measured to actual flux increased logarithmically as flux decreased, and reached parity at low levels typical of diffusive flux systems. Taken together, our results suggest that values for advective CO2 flux measured by SSFT and NSS chamber systems are likely to be significantly lower than the actual values due to back pressure developed in the chamber that diverts flux from entering the chamber. Chamber designs that counteract the back pressure and also avoid large Venturi effects associated with vent tubes, such as the SSFT with a narrow vent tube operated at a high chamber-flushing rate, are likely to yield flux measurements closer to the true values.

carbon dioxide↗

Combined Ventilation and Perfusion Imaging Correlates With the Dosimetric Parameters of Radiation Pneumonitis in Radiation Therapy Planning for Lung Cancer

Purpose: The purpose of this study was to prospectively investigate clinical correlations between dosimetric parameters associated with radiation pneumonitis (RP) and functional lung imaging. Methods and Materials: Functional lung imaging was performed using four-dimensional computed tomography (4D-CT) for ventilation imaging, single-photon emission computed tomography (SPECT) for perfusion imaging, or both (V/Q-matched region). Using 4D-CT, ventilation imaging was derived from a low attenuation area according to CT numbers below different thresholds (vent-860 and -910). Perfusion imaging at the 10th, 30th, 50th, and 70th percentile perfusion levels (F10-F70) were defined as the top 10%, 30%, 50%, and 70% hyperperfused normal lung, respectively. All imaging data were incorporated into a 3D planning system to evaluate correlations between RP dosimetric parameters (where fV20 is the percentage of functional lung volume irradiated with >20 Gy, or fMLD, the mean dose administered to functional lung) and the percentage of functional lung volume. Radiation pneumonitis was evaluated using Common Terminology Criteria for Adverse Events version 4.0. Statistical significance was defined as a P value of <.05. Results: Sixty patients who underwent curative radiation therapy were enrolled (48 patients for non-small cell lung cancer, and 12 patients for small cell lung cancer). Grades 1, 2, and ≥3 RP were observed in 16, 44, and 6 patients, respectively. Significant correlations were observed between the percentage of functional lung volume and fV20 (r=0.4475 in vent-860 and 0.3508 in F30) or fMLD (r=0.4701 in vent-860 and 0.3128 in F30) in patients with grade ≥2 RP. F30∩vent-860 results exhibited stronger correlations with fV20 and fMLD in patients with grade ≥2 (r=0.5509 in fV20 and 0.5320 in fMLD) and grade ≥3 RP (r=0.8770 in fV20 and 0.8518 in fMLD). Conclusions: RP dosimetric parameters correlated significantly with functional lung imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Achieving superior carbon transfer efficiency and pH control using membrane carbonation with a wide range of CO 2 contents for the coccolithophore Emiliania huxleyi

The economic viability of microalgal-derived products relies on rapid CO 2 transfer in a cost-effective manner. Many industrial gas streams contain concentrated CO 2 that, if converted to useful products, would lower greenhouse gas emissions and valorize the wasted CO 2 . Membrane carbonation (MC) uses non-porous hollow-fiber gas-transfer membranes to deliver CO 2 without bubble formation, which makes it possible to achieve a high carbon-transfer efficiency (CTE). However, inert gasses in the industrial streams (e.g., N 2 , O 2 , and H 2 O) can significantly lower the CO 2 -delivery rate. The means to overcome the buildup of inert gases in the membrane lumen is to manage the distal end of the membranes to sweep out inert gases while not wasting significant CO 2 . A MC-venting strategy was evaluated for CO 2 inputs from 5% to 100%. Abiotic tests using a restricted exit flow could achieve >95% CTE abiotic for industrial CO 2 streams. When integrated with semi-continuous cultivation of a marine coccolithophore, Emiliania huxleyi , CO 2 delivery and venting were on-demand based on a pH set points and pH-actuated feed and venting valves. MC using the venting strategy achieved 100% CTE biotic when delivering 100% and 50% CO 2 , which was better than 50% CTE biotic obtained from pH-controlled sparging of 100% CO 2 -sparging. E. huxleyi consistently fixed ~80% of the delivered CO 2 into biomass, and the remaining ~20% to calcite coccoliths. Finally, the compact size of MC modules, stable pH control, and no shear forces from bubble agitation during the CO 2 delivery made MC an ideal match for cultivation of coccolithophores, which are sensitive to shear forces and pH fluctuations.

54 ENVIRONMENTAL SCIENCES↗

Dust Studies in DIII-D and TEXTOR

Studies of naturally occurring and artificially introduced carbon dust are conducted in DIII-D and TEXTOR. In DIII-D, dust does not present operational concerns except immediately after entry vents. Submicron sized dust is routinely observed using Mie scattering from a Nd:Yag laser. The source is strongly correlated with the presence of Type I edge localized modes (ELMs). Larger size (0.005-1 mm diameter) dust is observed by optical imaging, showing elevated dust levels after entry vents. Inverse dependence of the dust velocity on the inferred dust size is found from the imaging data. Direct heating of the dust particles by the neutral beam injection (NBI) and acceleration of dust particles by the plasma flows are observed. Energetic plasma disruptions produce significant amounts of dust. Large flakes or debris falling into the plasma may result in a disruption. Migration of pre-characterized carbon dust is studied in DIII-D and TEXTOR by introducing micron-size dust in plasma discharges. In DIII-D, a sample holder filled with {approx}30 mg of dust is introduced in the lower divertor and exposed to high-power ELMing H-mode discharges with strike points swept across the divertor floor. After a brief exposure ({approx}0.1 s) at the outer strike point, part of the dust is injected into the plasma, raising the core carbon density by a factor of 2-3 and resulting in a twofold increase of the radiated power. In TEXTOR, instrumented dust holders with 1-45 mg of dust are exposed in the scrape-off layer 0-2 cm radially outside of the last closed flux surface in discharges heated with neutral beam injection (NBI) power of 1.4 MW. At the given configuration of the launch, the dust did not penetrate the core plasma and only moderately perturbed the edge plasma, as evidenced by an increase of the edge carbon content.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effect of Sb thickness on the performance of bialkali-antimonide photocathodes

The alkali species Cs and K were codeposited using an effusion source, onto relatively thick layers of Sb (50 nm to ∼7 μm) grown on GaAs and Ta substrates inside a vacuum chamber that was baked and not-vented, and also baked and vented with clean dry nitrogen but not rebaked. The characteristics of the Sb films, including sticking probability, surface roughness, grain size, and crystal properties were very different for these conditions, yet comparable values of photocathode yield [or quantum efficiency (QE)] at 284 V were obtained following codeposition of the alkali materials. Photocathodes manufactured with comparatively thick Sb layers exhibited the highest QE and the best 1/e lifetime. The authors speculate that the alkali codeposition enabled optimized stoichiometry for photocathodes manufactured using thick Sb layers, which could serve as a reservoir for the alkali materials.

42 ENGINEERING↗

Gas Generation Models for Thermal Runaway in Lithium Ion Batteries

A numerical model is implemented to study cell venting, internal pressure, and gas-phase dynamics behavior of Li-ion cells undergoing thermal runaway. A k-ɛ Reynolds-Averaged Navier-Stokes (RANS) model is adopted to describe the turbulent flow out of the cells, while the fluid dynamics inside the cells is described by Darcy-Forchheimer’s equation. Thermal abuse reactions and gas generation kinetics are described by a single-step lumped reaction model. A series of computational fluid dynamics (CFD) simulations are conducted on a single cell at various states-of-charge (100%, 50%, 25%) to demonstrate detailed flow and thermal behavior as a function of quantity of gas generated during cell venting. Venting events are categorized into two stages: i) breaching of the cell container and ii) thermal runaway reactions. It is shown that the cell response is dominated by the second stage since most of the gases are generated during thermal runaway. Also, the propensity for propagation is highly affected by state-of-charge (SOC). Cells at higher SOCs produce more heat and gas during the venting event, owing to higher mass and concentrations of reacting gases, and consequently reach higher internal cell pressures which increase the risk of side-wall breaching.

Kim, Jinyong↗

Pollutant Exposures from Natural Gas Cooking Burners: A Simulation-Based Assessment for Southern California

Background: Residential natural gas cooking burners (NGCBs) can emit substantial quantities of pollutants, and they are typically used without venting range hoods. Objective: We quantified pollutant concentrations and occupant exposures resulting from NGCB use in California homes. Methods: A mass-balance model was applied to estimate time-dependent pollutant concentrations throughout homes in Southern California and the exposure concentrations experienced by individual occupants. We estimated nitrogen dioxide (NO2), carbon monoxide (CO), and formaldehyde (HCHO) concentrations for 1 week each in summer and winter for a representative sample of Southern California homes. The model simulated pollutant emissions from NGCBs as well as NO2 and CO entry from outdoors, dilution throughout the home, and removal by ventilation and deposition. Residence characteristics and outdoor concentrations of NO2 and CO were obtained from available databases. We inferred ventilation rates, occupancy patterns, and burner use from household characteristics. We also explored proximity to the burner(s) and the benefits of using venting range hoods. Replicate model executions using independently generated sets of stochastic variable values yielded estimated pollutant concentration distributions with geometric means varying by < 10%. Results: The simulation model estimated that—in homes using NGCBs without coincident use of venting range hoods—62%, 9%, and 53% of occupants are routinely exposed to NO2, CO, and HCHO levels that exceed acute health-based standards and guidelines. NGCB use increased the sample median of the highest simulated 1-hr indoor concentrations by 100, 3,000, and 20 ppb for NO2, CO, and HCHO, respectively. Conclusions: Reducing pollutant exposures from NGCBs should be a public health priority. Simulation results suggest that regular use of even moderately effective venting range hoods would dramatically reduce the percentage of homes in which concentrations exceed health-based standards.

54 ENVIRONMENTAL SCIENCES↗

Pollutant Exposures from Natural Gas Cooking Burners: A Simulation-Based Assessment for Southern California

Residential natural gas cooking burners (NGCBs) can emit substantial quantities of pollutants and they are typically used without venting. The objective of this study is to quantify pollutant concentrations and occupant exposures resulting from NGCB use in California homes. A mass balance model was applied to estimate time-dependent pollutant concentrations throughout homes and the "exposure concentrations" experienced by individual occupants. The model was applied to estimate nitrogen dioxide (NO{sub 2}), carbon monoxide (CO), and formaldehyde (HCHO) concentrations for one week each in summer and winter for a representative sample of Southern California homes. The model simulated pollutant emissions from NGCBs, NO{sub 2} and CO entry from outdoors, dilution throughout the home, and removal by ventilation and deposition. Residence characteristics and outdoor concentrations of CO and NO{sub 2} were obtained from available databases. Ventilation rates, occupancy patterns, and burner use were inferred from household characteristics. Proximity to the burner(s) and the benefits of using venting range hoods were also explored. Replicate model executions using independently generated sets of stochastic variable values yielded estimated pollutant concentration distributions with geometric means varying less than 10%. The simulation model estimates that in homes using NGCBs without coincident use of venting range hoods, 62%, 9%, and 53% of occupants are routinely exposed to NO{sub 2}, CO, and HCHO levels that exceed acute health-based standards and guidelines. NGCB use increased the sample median of the highest simulated 1-hr indoor concentrations by 100, 3000, and 20 ppb for NO{sub 2}, CO, and HCHO, respectively. Reducing pollutant exposures from NGCBs should be a public health priority. Simulation results suggest that regular use of even moderately effective venting range hoods would dramatically reduce the percentage of homes in which concentrations exceed health-based standards.

03 NATURAL GAS↗