Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Threshold Estimate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

An experiment on the threshold effect in the coherent wave instability

Results are reported from an experimental study of the threshold effect in the coherent wave instability in which a combination of simulated VLF noise 200 Hz wide, superimposed on a variable amplitude constant frequency test signal (about 3 kHz) is transmitted from Siple Station, Antarctica, and received at Lake Mistissini, Quebec. As the test signal is slowly ramped up in power a 'threshold' level at which growth and triggering of emissions begin (coherent wave instability) is reached. It is shown that sufficiently strong simulated noise supresses the coherent wave instability, which corresponds to increasing the threshold level. This experiment is repeated at progressively lower levels of the simulated noise, until the threshold level for growth and triggering on the test signal no longer changes. At this point the simulated noise power is estimated to equal typical background noise levels due to magnetospheric hiss in the interaction region. It is suggested that unducted magnetospheric hiss is responsible for the threshold effect.

Mielke, T. A.↗

Physiological and behavioral effects of tilt-induced body fluid shifts

This paper addresses the 'fluid shift theory' of space motion sickness. The primary purpose of the research was the development of procedures to assess individual differences in response to rostral body fluid shifts on earth. Experiment I examined inner ear fluid pressure changes during head-down tilt in intact human beings. Tilt produced reliable changes. Differences among subjects and between ears within the same subject were observed. Experiment II examined auditory threshold changes during tilt. Tilt elicited increased auditory thresholds, suggesting that sensory depression may result from increased inner ear fluid pressure. Additional observations on rotation magnitude estimation during head-down tilt, which indicate that rostral fluid shifts may depress semicircular canal activity, are briefly described. The results of this research suggest that the inner ear pressure and auditory threshold shift procedures could be used to assess individual differences among astronauts prior to space flight. Results from the terrestrial observations could be related to reported incidence/severity of motion sickness in space and used to evaluate the fluid shift theory of space motion sickness.

Parker, D. E.↗

WE-H-207A-06: Hypoxia Quantification in Static PET Images: The Signal in the Noise

Purpose: Quantification of hypoxia from PET images is of considerable clinical interest. In the absence of dynamic PET imaging the hypoxic fraction (HF) of a tumor has to be estimated from voxel values of activity concentration of a radioactive hypoxia tracer. This work is part of an effort to standardize quantification of tumor hypoxic fraction from PET images. Methods: A simple hypoxia imaging model in the tumor was developed. The distribution of the tracer activity was described as the sum of two different probability distributions, one for the normoxic (and necrotic), the other for the hypoxic voxels. The widths of the distributions arise due to variability of the transport, tumor tissue inhomogeneity, tracer binding kinetics, and due to PET image noise. Quantification of HF was performed for various levels of variability using two different methodologies: a) classification thresholds between normoxic and hypoxic voxels based on a non-hypoxic surrogate (muscle), and b) estimation of the (posterior) probability distributions based on maximizing likelihood optimization that does not require a surrogate. Data from the hypoxia imaging model and from 27 cervical cancer patients enrolled in a FAZA PET study were analyzed. Results: In the model, where the true value of HF is known, thresholds usually underestimate the value for large variability. For the patients, a significant uncertainty of the HF values (an average intra-patient range of 17%) was caused by spatial non-uniformity of image noise which is a hallmark of all PET images. Maximum likelihood estimation (MLE) is able to directly optimize for the weights of both distributions, however, may suffer from poor optimization convergence. For some patients, MLE-based HF values showed significant differences to threshold-based HF-values. Conclusion: HF-values depend critically on the magnitude of the different sources of tracer uptake variability. A measure of confidence should also be reported.

60 APPLIED LIFE SCIENCES↗

Application of Statistical Methods of Rain Rate Estimation to Data From The TRMM Precipitation Radar

The TRMM Precipitation Radar is well suited to statistical methods in that the measurements over any given region are sparsely sampled in time. Moreover, the instantaneous rain rate estimates are often of limited accuracy at high rain rates because of attenuation effects and at light rain rates because of receiver sensitivity. For the estimation of the time-averaged rain characteristics over an area both errors are relevant. By enlarging the space-time region over which the data are collected, the sampling error can be reduced. However. the bias and distortion of the estimated rain distribution generally will remain if estimates at the high and low rain rates are not corrected. In this paper we use the TRMM PR data to investigate the behavior of 2 statistical methods the purpose of which is to estimate the rain rate over large space-time domains. Examination of large-scale rain characteristics provides a useful starting point. The high correlation between the mean and standard deviation of rain rate implies that the conditional distribution of this quantity can be approximated by a one-parameter distribution. This property is used to explore the behavior of the area-time-integral (ATI) methods where fractional area above a threshold is related to the mean rain rate. In the usual application of the ATI method a correlation is established between these quantities. However, if a particular form of the rain rate distribution is assumed and if the ratio of the mean to standard deviation is known, then not only the mean but the full distribution can be extracted from a measurement of fractional area above a threshold. The second method is an extension of this idea where the distribution is estimated from data over a range of rain rates chosen in an intermediate range where the effects of attenuation and poor sensitivity can be neglected. The advantage of estimating the distribution itself rather than the mean value is that it yields the fraction of rain contributed by the light and heavy rain rates. This is useful in estimating the fraction of rainfall contributed by the rain rates that go undetected by the radar. The results at high rain rates provide a cross-check on the usual attenuation correction methods that are applied at the highest resolution of the instrument.

Meneghini, R.↗

Dynamic delamination crack propagation in a graphite/epoxy laminate

Dynamic delamination crack propagation in a (90/0) 5s Graphite/Epoxy laminate with an embedded interfacial crack was investigated experimentally using high speed photography. The dynamic motion was produced by impacting the beamlike laminate specimen with a silicon rubber ball. The threshold impact velocities required to initiate dynamic crack propagation in laminates with varying initial crack positions were determined. The crack propagation speeds were estimated from the photographs. Results show that the through the thickness position of the embedded crack can significantly affect the dominant mechanism and the threshold impact velocity for the onset of crack movement. If the initial delamination is placed near the top of bottom surface of the laminate, local buckling of the delaminated plies may cause instability of the crack. If the initial delamination lies on the midplane, local buckling does not occur and the initiation of crack propagation appears to be dominated by Mode II fracture. The crack propagation and arrest observed was seen to be affected by wave motion within the delamination region.

Grady, J. E.↗

Neutron fluences and dose equivalents measured with passive detectors on LDEF

Neutron fluences were measured on LDEF in the low energy (< 1 MeV) and high energy (> 1 MeV) ranges. The low energy detectors used the 6Li(n,alpha)T reaction with Gd foil absorbers to separate thermal (< 0.2 eV) and resonance (0.2 eV-1 MeV) neutron response. High energy detectors contained sets of fission foils (181Ta, 209Bi, 232Th, 238U) with different neutron energy thresholds. The measured neutron fluences together with predicted spectral shapes were used to estimate neutron dose equivalents. The detectors were located in the A0015 and P0006 experiments at the west and Earth sides of LDEF under shielding varying from 1 to 19 g/cm2. Dose equivalent rates varied from 0.8 to 3.3 microSv/d for the low energy neutrons and from 160 to 390 microSv/d for the high energy neutrons. This compares with TLD measured absorbed dose rates in the range of 1000-3000 microGy/d near these locations and demonstrates that high energy neutrons contribute a significant fraction of the total dose equivalent in LEO. Comparisons between measurements and calculations were made for high energy neutrons based on fission fragment tracks generated by fission foils at different shielding depths. A simple 1-D slab geometry was used in the calculations. Agreement between measurements and calculations depended on both shielding depth and threshold energy of the fission foils. Differences increased as both shielding and threshold energy increased. The modeled proton/neutron spectra appeared deficient at high energies. A 3-D model of the experiments is needed to help resolve the differences.

LDEF Project↗

Fast simulation of packet loss rates in a shared buffer communications switch

This paper describes an efficient technique for estimating, via simulation, the probability of buffer overflows in a queueing model that arises in the analysis of ATM (Asynchronous Transfer Mode) communication switches. There are multiple streams of (autocorrelated) traffic feeding the switch that has a buffer of finite capacity. Each stream is designated as either being of high or low priority. When the queue length reaches a certain threshold, only high priority packets are admitted to the switch's buffer. The problem is to estimate the loss rate of high priority packets. An asymptotically optimal importance sampling approach is developed for this rare event simulation problem. In this approach, the importance sampling is done in two distinct phases. In the first phase, an importance sampling change of measure is used to bring the queue length up to the threshold at which low priority packets get rejected. In the second phase, a different importance sampling change of measure is used to move the queue length from the threshold to the buffer capacity.

Chang, Cheng-Shang↗

Design and characterization of a phonon-mediated cryogenic particle detector with an eV-scale threshold and 100 keV-scale dynamic range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Tromov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an oine optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

Ren, R↗

Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LI-RADS for CT diagnosis of hepatocellular carcinoma: performance of major and ancillary features

Purpose: To evaluate the diagnostic performance of Liver Imaging Reporting and Data System (LI-RADS) v2017 major features, the impact of ancillary features, and categories on contrast-enhanced computed tomography (CECT) for the diagnosis of hepatocellular carcinoma (HCC). Materials and methods: This retrospective study included 59 patients (104 observations including 72 HCCs) with clinical suspicion of HCC undergoing CECT between 2013 and 2016. Two radiologists independently assessed major and ancillary imaging features for each liver observation and assigned a LI-RADS category based on major features only and in combination with ancillary features. The composite reference standard included pathology or imaging. Per-lesion estimates of diagnostic performance of major features, ancillary features, and LI-RADS categories were assessed by generalized estimating equation models. Results: Major features (arterial phase hyperenhancement, washout, capsule, and threshold growth) respectively had a sensitivity of 86.1%, 81.6%, 20.7%, and 26.1% and specificity of 39.3%, 67.9%, 89.9%, and 85.0% for HCC. Ancillary features (ultrasound visibility as discrete nodule, subthreshold growth, and fat in mass more than adjacent liver) respectively had a sensitivity of 42.6%, 50.8%, and 15.1% and a specificity of 79.2%, 66.9%, and 96.4% for HCC. Ancillary features modified the final category in 4 of 104 observations. For HCC diagnosis, categories LR-3, LR-4, LR-5, and LR-TIV (tumor in vein) had a sensitivity of 5.3%, 29.0%, 53.7%, and 10.7%; and a specificity of 49.1%, 84.4%, 97.3%, and 96.4%, respectively. Conclusion: On CT, LR-5 category has near-perfect specificity for the diagnosis of HCC and ancillary features modifies the final category in few observations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hyperon production from neutrino-nucleon reaction

The neutrino induced hyperon production processes ν¯ e/μ + p → e + /μ + + π + Λ/Σ may provide a unique clean place for studying low energy πΛ/Σ interaction and hyperon resonances below KN threshold. The production rates for some neutrino induced hyperon production processes are estimated with theoretical models. Lastly, suggestions are made for the study of hyperon production from neutrino–nucleon reaction at present and future neutrino facilities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comments on extracting the resonance strength parameter from yield data

The F(α,n) reaction is the focus of on-going research in part because it is an important source of neutrons in the nuclear fuel cycle which can be exploited to assay nuclear materials, especially uranium in the form of UF 6 . At the present time there remains some considerable uncertainty (of the order of ± 20%) in the thick target integrated over angle (α,n) yield from 19 F (100% natural abundance) and its compounds as discussed. An important thin target cross-section measurement is that of Wrean and Kavanagh who explore the region from below threshold (2.36 MeV) to approximately 3.1 MeV with fine energy resolution. Integration of their cross-section data over the slowing down history of a stopping α-particle allows the thick target yield to be calculated for incident energies up to 3.1 MeV. This trend can then be combined with data from other sources to obtain a thick target yield curve over the wider range of interest to the fuel cycle (roughly threshold to 10 MeV to include all relevant α-emitters). To estimate the thickness of the CaF 2 target they used, Wrean and Kavanagh separately measured the integrated yield of the 6.129 MeV γ-rays from the resonance at 340.5 keV (laboratory α-particle kinetic energy) in the 19 F(p,αγ) reaction. To interpret the data they adopted a resonance strength parameter of (22.3 ± 0.8) eV based on a determination by Becker et al. The value and its uncertainty directly affects the thickness estimate and the extracted (α,n) cross-section values. In their citation to Becker et al's work, Wrean and Kavanagh comment that they did not make use of an alternative value of (23.7±1.0) eV reported by Croft because they were unable to reproduce the value from the data given in that paper. The value they calculated for the resonance strength from the thick target yield given by Croft was 21.4 eV. The purpose of this communication is to revisit the paper by Croft published in this journal and specifically to explain the origin of the reported resonance strength. Fortunately the original notes spanning the period 12 January 1988 to 16 January 1990 were available to consult. Finally, in hindsight there is certainly a case of excessive brevity to rectify. In essence the step requiring explanation is how to compute the resonance strength, ω γ , from the reported thick target resonance yield Y.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for measuring multiple scattering corrections between liquid scintillators

In this study, a time-of-flight method is proposed to experimentally quantify the fractions of neutrons scattering between scintillators. An array of scintillators is characterized in terms of crosstalk with this method by measuring a californium source, for different neutron energy thresholds. The spectral information recorded by the scintillators can be used to estimate the fractions of neutrons multiple scattering. With the help of a correction to Feynman's point model theory to account for multiple scattering, these fractions can in turn improve the mass reconstruction of fissile materials under investigation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Background studies for the MINER Coherent Neutrino Scattering reactor experiment

The proposed Mitchell Institute Neutrino Experiment at Reactor (MINER) experiment at the Nuclear Science Center at Texas A&M University will search for coherent elastic neutrino-nucleus scattering within close proximity (about 2 m) of a 1 MW TRIGA nuclear reactor core using low threshold, cryogenic germanium and silicon detectors. Given the Standard Model cross section of the scattering process and the proposed experimental proximity to the reactor, as many as 5–20 events/kg/day are expected. In this work, we discuss the status of preliminary measurements to characterize the main backgrounds for the proposed experiment. Both in situ measurements at the experimental site and simulations using the MCNP and GEANT4 codes are described. A strategy for monitoring backgrounds during data taking is briefly discussed.

47 OTHER INSTRUMENTATION↗

Impact of Extreme Heat on Emergency Department Admissions for Childhood and Adult Asthma: An Evaluation of Earth Observations and Heat Wave Definitions

Extreme heat has been associated with adverse health outcomes, yet its impact on asthma exacerbations remains understudied. This is, in part, due to data limitations: research that relies on weather station records and aggregated health statistics cannot resolve fine-scale differences in heat impacts. This study investigates the association between heat wave definitions and summertime asthma-related emergency department visits in Baltimore, Maryland from 2016 to 2022, including 819 adult and 695 pediatric exacerbations. Using geocoded electronic health records and air temperature measurements at several spatial resolutions, we applied a case-crossover design with conditional logistic regressions at the census block group and tract levels. We found strong associations between asthma exacerbations and nighttime heat wave definitions based on relative thresholds of minimum temperatures when census block group or tract level temperature estimates were used. These relationships were significant for both age groups and showed elevated risks in socially vulnerable areas. In contrast, heat wave definitions derived from the city's primary National Weather Service synoptic weather station show associations between asthma and daytime heat extremes, suggesting that the character of the heat hazard depends on the scale at which it is defined. The extreme heat event definition used by Baltimore City's Code Red system showed no significant association with exacerbations. These findings highlight the importance of data resolution in shaping health inferences related to extreme heat in urban environments. Further, this study demonstrates that, regardless of spatial scale, extreme heat is associated with asthma exacerbations in both age groups.

Corpuz, B. [Johns Hopkins University, Baltimore, M↗

The rates and time-delay distribution of multiply imaged supernovae behind lensing clusters

Time delays of gravitationally lensed sources can be used to constrain the mass model of a deflector and determine cosmological parameters. We here present an analysis of the time-delay distribution of multiply imaged sources behind 17 strong lensing galaxy clusters with well-calibrated mass models. We find that for time delays less than 1000 days, at z = 3.0, their logarithmic probability distribution functions are well represented by P(log Δt) = 5.3 × 10{sup −4}Δt{sup β-tilde}/M{sub 250}{sup 2β-tilde}, with β-tilde = 0.77, where M{sub 250} is the projected cluster mass inside 250 kpc (in 10{sup 14}M{sub ☉}), and β-tilde is the power-law slope of the distribution. The resultant probability distribution function enables us to estimate the time-delay distribution in a lensing cluster of known mass. For a cluster with M{sub 250} = 2 × 10{sup 14}M{sub ☉}, the fraction of time delays less than 1000 days is approximately 3%. Taking Abell 1689 as an example, its dark halo and brightest galaxies, with central velocity dispersions σ≥500kms{sup −1}, mainly produce large time delays, while galaxy-scale mass clumps are responsible for generating smaller time delays. We estimate the probability of observing multiple images of a supernova in the known images of Abell 1689. A two-component model of estimating the supernova rate is applied in this work. For a magnitude threshold of m{sub AB} = 26.5, the yearly rate of Type Ia (core-collapse) supernovae with time delays less than 1000 days is 0.004±0.002 (0.029±0.001). If the magnitude threshold is lowered to m{sub AB} ∼ 27.0, the rate of core-collapse supernovae suitable for time delay observation is 0.044±0.015 per year.

79 ASTRONOMY AND ASTROPHYSICS↗

Factors for conversion between human and automatic read-outs of CDMAM images

Purpose: According to the European protocol for the quality control of the physical and technical aspects of mammography screening (EPQCM) image quality of digital mammography devices has to be assessed using human evaluation of the CDMAM contrast-detail phantom. This is accomplished by the determination of threshold thicknesses of gold disks with different diameters (0.08-2 mm) and revealed to be very time consuming. Therefore a software solution based on a nonprewhitening matched filter (NPW) model was developed at University of Nijmegen. Factors for the conversion from automatic to human readouts have been determined by Young et al.[Proc. SPIE 614206, 1-13 (2006) and Proc. SPIE 6913, 69131C1 (2008)] using a huge amount of data of both human and automatic readouts. These factors depend on the observer groups and are purely phenomenological. The authors present an alternative approach to determine the factors by using the Rose observer model. Methods: Their method uses the Rose theory which gives a relationship between threshold contrast, diameter of the object and number of incident photons. To estimate the conversion factors for the five diameters from 0.2 to 0.5 mm they exposed with five different current-time products which resulted in 25 equations with five unknowns. Results: The theoretical conversion factors (in dependence of the diameters) amounted to be 1.61 {+-} 0.02 (0.2 mm diameter), 1.67 {+-} 0.02 (0.25 mm), 1.85 {+-} 0.02 (0.31 mm), 2.09 {+-} 0.02 (0.4 mm), and 2.28 {+-} 0.02 (0.5 mm). The corresponding phenomenological factors found in literature are 1.74 (0.2 mm), 1.78 (0.25 mm), 1.83 (0.31 mm), 1.88 (0.4 mm), and 1.93 (0.5 mm). Conclusions: They transferred the problem of determining the factors to a well known observer model which has been examined for many years and is also well established. This method reveals to be reproduceable and produces factors comparable to the phenomenological ones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗