Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Thermal testing techniques for space shuttle thermal protection system panels

An experimental system was developed for evaluation of the effects of aerodynamic heating and cooling, vacuum, and pressure loading on candidate insulation packages proposed for use on the space shuttle. The system includes a number of design features which facilitate rapid recycle times. This is necessary to efficiently conduct extensive thermal cycling tests on these insulation packages to determine their reuse capabilities. The heart of the system is a 26-inch graphite element radiant heater. A susceptor plate functions as a uniform-temperature intermediate radiating surface. The susceptor also forms the lid of an inert atmosphere enclosure which separates the heater from the oxidizing test atmosphere. In some tests the plate properly simulates the heating from an actual flight heat-shield panel. Although other materials were used at lower required test temperatures, 2500 F was routinely achieved using a coated columbium susceptor plate.

Cox, B. G.↗

Thermal modeling of phase change solidification in thermal control devices including natural convection effects

Natural convection effects in phase change thermal control devices were studied. A mathematical model was developed to evaluate natural convection effects in a phase change test cell undergoing solidification. Although natural convection effects are minimized in flight spacecraft, all phase change devices are ground tested. The mathematical approach to the problem was to first develop a transient two-dimensional conduction heat transfer model for the solidification of a normal paraffin of finite geometry. Next, a transient two-dimensional model was developed for the solidification of the same paraffin by a combined conduction-natural-convection heat transfer model. Throughout the study, n-hexadecane (n-C16H34) was used as the phase-change material in both the theoretical and the experimental work. The models were based on the transient two-dimensional finite difference solutions of the energy, continuity, and momentum equations.

Ukanwa, A. O.↗

Effects of thermal loading on foil and sheet composites with constituents of differing thermal expansivities.

A study was made to estimate the magnitudes of elastic stresses and elastic-plastic stresses and strains in sheet or foil laminar composites. Using a model tungsten/80Ni + 20Cr laminar composite and assuming cooling or heating through a temperature range of 80-2000 deg F (26.5-1093.5 deg C), calculated elastic stresses exceeded published or estimated strengths of the constituents. Elastic-plastic stress-strain solutions resulted in lower estimated stress levels but with the concomitant occurrence of sufficiently large strain ranges to suggest possible thermal fatigue problems. Limited experimental studies using tungsten/80Ni + 20Cr foil and sheet laminar composites, slowly cycled between 80 and 2000 deg F (26.5-1093.5 deg C) or rapidly cycled between 80 and 1600 deg F (26.5-871 deg C) produced varying degrees of observable structural damage in from 1 to 11 cycles depending upon temperature transition rate and laminae thickness; these particular results might not occur with other combinations of materials.

Hoffman, C. A.↗

Effects of thermal loading on fiber-reinforced composites with constituents of differing thermal expansivities.

Estimates of the magnitudes of elastic stresses and elastoplastic stresses and strains were made for tungsten fiber-reinforced 80Ni + 20Cr matrix composites. Heating or cooling between 80 and 2000 F was assumed. The calculated elastic stresses exceeded representative or estimated strengths of constituents. For composites with less than 0.65 volume fraction of fiber, plastic flow was considered possible, and elastoplastic solutions indicated that stresses would be reduced but with the concomitant occurrence of sufficiently large strain ranges, particularly in the matrix, to pose a possible thermal fatigue problem. Limited experimental studies on tungsten fiber-copper matrix composites heated and cooled a number of times between 80 and 1600 F in a conventional furnace and then heated from 80 to 1652 F in a hot-stage microscope resulted in matrix microfracture for a 70 volume fraction fiber composite and substantial matrix strain for a 40 volue fraction fiber composite.

Hoffman, C. A.↗

Development of thermal stratification and destratification scaling concepts. Volume 1: Definition of thermal stratification scaling parameters and experimental investigations

The dimensionless parameters associated with the thermal stratification and pressure history of a heated container of liquid and its vapor were examined. The Modified Grashof number, the Fourier number, and an Interface number were parameterized using a single test liquid, Freon 113. Cylindrical test tanks with spherical dome end caps were built. Blanket heaters covered the tanks and thermocouples monitored the temperatures of the liquid, the ullage, the tank walls, and the foam insulation encapsulating the tank. A centrifuge was used for the 6 inch tank to preserve the same scaling parameter values between it and the larger tanks. Tests were conducted over a range of Gr* values and the degree of scaling was checked by comparing the dimensionless pressures and temperatures for each scaled pair of tests. Results indicate that the bulk liquid temperature, the surface temperature of the liquid, and the tank pressure can be scaled with the three dimensionless parameters. Some deviation was, however, found in the detailed temperature profiles between the scaled pairs of tests.

Lovrich, T. N.↗

An investigation of thermal anomalies in the Central American volcanic chain and evaluation of the utility of thermal anomaly monitoring in the prediction of volcanic eruptions

The author has identified the following significant results. Ground truth data collection proves that significant anomalies exist at 13 volcanoes within the test site of Central America. The dimensions and temperature contrast of these ten anomalies are large enough to be detected by the Skylab 192 instrument. The dimensions and intensity of thermal anomalies have changed at most of these volcanoes during the Skylab mission.

Stoiber, R. E.↗

Thermal Power Systems (TPS); Point-Focusing Thermal and Electric Applications (PFTEA). Volume 2: Detailed report, fiscal year 1979

Progress in the development of systems which employ point focusing distributed receiver technology is reported. Emphasis is placed on the first engineering experiment, the Small Community Solar Thermal Power Experiment. Procurement activities for the Military Module Power Experiment the first of a series of experiments planned as part of the Isolated Load Series are included.

Source record↗

Prolonging thermal barrier coated specimen life by thermal cycle management

Measurements were made of the rate of increase in temperature of a ZrO2-8Y2O3 thermal barrier coated (TBC) specimen for various values of fuel/air (F/A) ratios when the specimen is exposed to a 0.3 Mach burner flame. For rod specimens in a carousel, the heating rates increased with (F/A) ratio and were higher at the inward facing surface for a given (F/A). Plate specimens were more sensitive to burner variations. Calculated results are given for the radial stress in the coated rod specimens for variations in (F/A) ratios from 0.04 to 0.065. Over this range, the radial stress varies from 4.3 to 5.3 MPa. The results indicate that controlling the heating rate of a TBC by controlling the (F/A) ratio offers a potential method to prolong TBC cyclic life; uncontrolled (F/A) ratios will produce scatter in experimental results. Geometric arrangement can have an equivalent effect, but is usually fixed by design.

Hendricks, R. C.↗

Thermal Pollution Math Model. Volume 1. Thermal Pollution Model Package Verification and Transfer

Two three dimensional, time dependent models, one free surface, the other rigid lid, were verified at Anclote Anchorage and Lake Keowee respectively. The first site is a coastal site in northern Florida; the other is a man-made lake in South Carolina. These models describe the dispersion of heated discharges from power plants under the action of ambient conditions. A one dimensional, horizontally-averaged model was also developed and verified at Lake Keowee. The data base consisted of archival in situ measurements and data collected during field missions. The field missions were conducted during winter and summer conditions at each site. Each mission consisted of four infrared scanner flights with supporting ground truth and in situ measurements. At Anclote, special care was taken to characterize the complete tidal cycle. The three dimensional model results compared with IR data for thermal plumes on an average within 1 C root mean square difference. The one dimensional model performed satisfactorily in simulating the 1971-1979 period.

Lee, S. S.↗

Study of thermal management for space platform applications: Unmanned modular thermal management and radiator technologies

Candidate techniques for thermal management of unmanned modules docked to a large 250 kW platform were evaluated. Both automatically deployed and space constructed radiator systems were studied to identify characteristics and potential problems. Radiator coating requirements and current state-of-the-art were identified. An assessment of the technology needs was made and advancements were recommended.

Oren, J. A.↗

Thermal barrier coatings for thermal insulation and corrosion resistance in industrial gas turbine engines

Four thermal barrier coatings were subjected to a 500-hour gas turbine engine test. The coatings were two yttria stabilized zirconias, calcium ortho silicate and calcium meta titanate. The calcium silicate coating exhibited significant spalling. Yttria stabilized zirconia and calcium titanate coatings showed little degradation except in blade leading edge areas. Post-test examination showed variations in the coating due to manual application techniques. Improved process control is required if engineering quality coatings are to be developed. The results indicate that some leading edge loss of the coating can be expected near the tip.

Vogan, J. W.↗