Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Method to Calculate Uncertainty Estimate of Measuring Shortwave Solar Irradiance using Thermopile and Semiconductor Solar Radiometers

The uncertainty of measuring solar irradiance is fundamentally important for solar energy and atmospheric science applications. Without an uncertainty statement, the quality of a result, model, or testing method cannot be quantified, the chain of traceability is broken, and confidence cannot be maintained in the measurement. Measurement results are incomplete and meaningless without a statementof the estimated uncertainty with traceability to the International System of Units (SI) or to another internationally recognized standard. This report explains how to use International Guidelines of Uncertainty in Measurement (GUM) to calculate such uncertainty. The report also shows that without appropriate corrections to solar measuring instruments (solar radiometers), the uncertainty ofmeasuring shortwave solar irradiance can exceed 4% using present state-of-the-art pyranometers and 2.7% using present state-of-the-art pyrheliometers. Finally, the report demonstrates that by applying the appropriate corrections, uncertainties may be reduced by at least 50%. The uncertainties, with or without the appropriate corrections might not be compatible with the needs of solar energy andatmospheric science applications; yet, this report may shed some light on the sources of uncertainties and the means to reduce overall uncertainty in measuring solar irradiance.

14 SOLAR ENERGY↗

Comparing wall performance predicted from hygrothermal simulations to wall performance measured from environmental chamber experiments

To effectively mitigate prevailing perceptions of potential moisture risks in high-R wall assemblies, a comprehensive moisture durability assessment that incorporates BA team field evaluations, lab tests and simulations has been completed over the last couple years. In FY18, three stick-built walls were succumbed to typical Chicago weather in ORNL’s Heat, Air and Moisture chamber. The measured temperature, relative humidity and moisture content within these walls were compared to WUFI hygrothermal simulation results. In FY19, similar experiments and comparison to WUFI results were completed with two walls, a Structural Insulated Panel (SIP) based wall and a Concrete Masonry Unit (CMU) based wall. The following tasks were completed for these two walls: 1. Measure air permeance of each individual wall using ASTM E283 Standard Test Method. 2.Test walls in diffusion scenario as only moisture transport mechanism and compare measured transient temperature and relative humidity of select wall components to WUFI model results. Chicago summer and weather will be investigated. 3. Test walls in wetting event scenario and compare measured transient temperature and relative humidity of select wall components with Chicago summer weather to WUFI model results. 4. Test walls in diffusion/advection scenario. In addition to controlling outdoor chamber to match real outdoor weather, a pressure differential across the wall will be varied. Measured transient temperature and relative humidity of select wall components will be compared to WUFI model results. 5. Test walls in diffusion/advection with solar heating of cladding. In addition to the variables above, IR lamps will be used to heat the cladding on a diurnal cycle. Measured transient OSB MC and temperature will be compared to WUFI model results. This report documents the experimental method, results and comparison of the measured experimental hygrothermal performance of the two walls to simulations results.

42 ENGINEERING↗

Update on Investigations of Viability of Cold Spray and FSW as a Spent Nuclear Fuel Dry Storage Canister Mitigation Tool

The purpose of this work is to investigate the use of cold spray and friction stir welding or processing (FSW/P) for repair and mitigation of chloride-induced stress corrosion cracking (CISCC) in dry cask storage system (DCSS) canisters to ensure integrity far beyond their original license period. This report provides a viability analysis of cold spray and friction stir welding for repair and fabrication of DCSS canisters. This report presents experimental work and a research strategy to optimize and evaluate cold spray and FSW/P for CISCC resistance. The literature reports that the following three conditions must exist for CISCC to occur: tensile stress, corrosive environment, and susceptible material. These conditions must be understood and accounted for while evaluating CISCC susceptibility. Furthermore, non-obvious factors, such as surface conditions and geometric confinement, can dramatically increase the intensity of one or more of the three listed conditions for CISCC. Arc welding should be considered for either temporary or permanent repair when combined with a mitigation technology. It is known that alloys used in the existing inventory of spent nuclear fuel storage canisters become sensitized in areas around fusion welds. Technologies, such as cold spray or FSW, can mitigate the sensitization caused by fusion welds. FSW/P and cold spray, potential alternatives for fabrication and repair, are solid-phase processes. No melting occurs and the energy input can be controlled such that no harm is done to the base metal during these processes. FSW/P should be considered for use in new fabrication of canisters and repair of existing canisters. Low heat input and grain refinement result in material with improved mechanical properties and comparable generalized corrosion performance relative to base metal. FSW/P offers the potential of through-thickness CISCC resistance. Cold spray should be considered for production, mitigation, and repair of canisters. Cold spray has demonstrated the ability to deposit stainless steel, Inconel alloys, and other alloys on stainless steel 304L such that galvanic potential is matched and resistance to pitting is improved. The technical basis for cold spray mitigation and repair within the overpack using remote robotic equipment is established. A non-obvious application to the research community is the sealing of crevices. All reported instances of CISCC in the fielded nuclear applications were associated with crevice corrosion. This can be avoided by cold spraying to seal crevices. The bulk of the work planned for FY 2020 will be generating coupons for CISCC testing by collaborative projects at Pacific Northwest National Laboratory and Sandia National Laboratories. First an exploratory study will be executed that will include screening studies and process optimization. This task will identify the effect of process parameters on microstructure and CISCC resistance. Optimized parameters will be used to produce a smaller number of coupons for full testing and evaluation. Test methods for evaluating CISCC resistance must meet the following criteria: (1) normalized surface geometry and exposed process microstructure, (2) account for residual stresses, (3) be in a controlled and appropriate test environment, and (4) be numerically quantifiable and repeatable. Failure to meet these criteria could lead to results that cannot be used for comparative analysis of processes and materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Degradation Characterization of Thermal Interface Greases

Thermal interface materials (TIMs) are used in power electronics packaging to minimize thermal resistance between the heat generating component and the heat sink. Thermal greases are one such class. The conformability and thin bond line thickness (BLT) of these TIMs can potentially provide low thermal resistance throughout the operation lifetime of a component. However, their performance degrades over time due to pump-out and dry-out during thermal and power cycling. The reliability performance of greases through operational cycling needs to be quantified to develop new materials with superior properties. NREL, in collaboration with DuPont, has performed thermal and reliability characterization of several commercially available thermal greases. Initial bulk and contact thermal resistance of grease samples were measured, and then the thermal degradation that occurred due to pump-out and dry-out during temperature cycling was monitored. The thermal resistances of five different grease materials were evaluated using NREL's steady-state thermal resistance tester based on the ASTM test method D5470. Greases were then applied, utilizing a 2.5 cm x 2.5 cm stencil, between invar and aluminum plates to compare the thermomechanical performance of the materials in a representative test fixture. Scanning Acoustic microscopy, thermal, and compositional analyses were performed periodically during thermal cycling from -40 degrees C to 125 degrees C. Completion of this characterization has allowed for a comprehensive evaluation of thermal greases both for their initial bulk and contact thermal performance, as well as their degradation mechanisms under accelerated thermal cycling conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ULTRASOUND AND X-RAY CHARACTERIZATION OF DAMAGE IN ALUMINA STRUCTURAL CERAMICS

A combination of destructive and nondestructive testing methods was utilized to evaluate the impact velocity and energy conditions that caused fracture in alumina structural ceramics. Incremental damage was produced in aluminum-backed Al{sub 2}O{sub 3} tiles using drop tower testing for low velocity impact with a high mass indenter. The majority of damage in the fractured samples consisted of radial and cone cracking. The samples were nondestructively evaluated using digital radiography, x-ray computed tomography, and ultrasound C-scan imaging. Bulk damage detected by these techniques was compared to surface damage observed by visual inspection. Qualitative evaluation of surface and bulk cracks and quantitative percent damage assessment were used to compare the integrity of the nondestructive techniques. While all three methods were able to detect surface cracks, C-scan imaging was more effective at detecting internal damage in the alumina samples and x-ray computed tomography was more effective at producing three-dimensional images of the crack patterns.

36 MATERIALS SCIENCE↗

An Objective and Efficient Method for Assessing the Impact of Reduced-Precision Calculations On Solution Correctness

Recent studies have shown that reducing the precision of floating-point calculations in an atmospheric model can improve the models' computational performance without affecting model fidelity, but code changes are needed to accommodate lower precision, and a small number of calculations might need to retain higher precision to prevent undue round-off error. For complex and computationally expensive systems like the Energy Exascale Earth System Model (E3SM), a method is needed to objectively assess the quality of the lower-precision simulations and to quickly identify problematic code pieces This paper demonstrates that solution correctness can be evaluated through a simple and quantitative error metric based on time step convergence. The proposed test method can unambiguously detect the accumulation of precision error and objectively assess its impact on solution accuracy. Since fast physical processes are known to affect key features of the multi-year mean climate in an atmospheric model, we show that the convergence test applied to short simulations can provide useful information about the impact of reduced precision on a model’s long-term behavior. In contrast, the traditional way of climate model evaluation requires multi-year simulations and involves inspecting many physical quantities for statistical significance in the presence of natural variability. The simplicity, computational efficiency, and objectivity of the proposed method makes it very attractive for high-resolution model development. The method is also expected to be applicable to other models that numerically solve time evolution equations.

97 MATHEMATICS AND COMPUTING↗

A Review on Friction Stir Processing of Titanium Alloy: Characterization, Method, Microstructure, Properties

In the past two decades, friction stir processing (FSP) technology has received considerable attention. FSP can be used to adjust and control the microstructure of materials, including eliminating defects, destroying dendrites and controlling fractions in the second stage, and is therefore widely used in titanium and its alloys for biomedical, aerospace and automotive applications. This article comprehensively reviews the methods of studying FSP, the microstructure evolution of materials and the summary of material properties. It begins with the introduction of the FSW system, characterization, structure and elemental analysis, and simulation and performance testing methods, and then introduces the microstructure evolution mechanism of various titanium materials and discusses in detail the material properties of titanium alloy, namely hardness and wear resistance, elasticity and plasticity, corrosion resistance and biocompatibility. Finally, this review presents unresolved issues and outstanding challenges in FSP technology and reveals the direction of this emerging field of research.

36 MATERIALS SCIENCE↗

Investigation of the accuracy of modeling the orientation distribution function of polycrystalline materials from individual orientations

The accuracy of reconstructing the orientation distribution function of grains in polycrystalline materials by the kernel method from a set of individual orientations has been studied. In particular, the influence of choosing the smoothing kernel in the kernel method and the influence of the dependence on the resulting distribution are taken into account. The rotations obeying the normal distribution on the group SO(3) and obtained by the statistical test method are used as an orientation set. Some aspects of electron backscattering diffraction measurements are considered. This problem is urgent in view of the expanding potential of the experimental study of the texture of polycrystalline materials, especially for electron microscopy, which makes it possible to measure the orientations of individual grains.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis of new superheavy elements using the Dubna Gas-Filled Separator: The complex of technologies

All the new isotopes of superheavy elements in the reactions with {sup 48}Ca ions and actinide targets, synthesized at the Flerov Laboratory of Nuclear Reactions (FLNR), have been obtained at the Dubna Gas-Filled Recoil Separator (DGFRS). Success was achieved with the use of several techniques, algorithms and approaches with record performance in their area. The most sophisticated of them are rare event detection technology, methods of measuring the effective equilibrium charges of heavy ions and nuclei in hydrogen at low pressure, modified approaches to evaluation of probabilistic characteristics of detected multichain events, beam-free test methods of detection equipment, and some other ones. The author analyzes the approaches that have led ultimately to a real breakthrough and an advance in experiments on the synthesis of superheavy elements. The development of detection systems also attracts the authors’ attention. Contributions from some facilities—such as SHIP, TASCA, and GARIS (RIKEN)—to synthesis experiments are partially noted. Under consideration are methods of automation of similar experiments, including the development of control and shielding systems for operation with highly active actinide targets. Some techniques for detecting α decay of heavy nuclei that came before the current experiments with electromagnetic separators are reviewed briefly. The methods, algorithms and hardware presented cover a more than twenty-year period of commissioning and application in long-term experiments at FLNR DGFRS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Load Disaggregation Technologies: Real World and Laboratory Performance

Low cost interval metering and communication technology improvements over the past ten years have enabled the maturity of load disaggregation (or non-intrusive load monitoring) technologies to better estimate and report energy consumption of individual end-use loads. With the appropriate performance characteristics, these technologies have the potential to enable many utility and customer facing applications such as billing transparency, itemized demand and energy consumption, appliance diagnostics, commissioning, energy efficiency savings verification, load shape research, and demand response measurement. However, there has been much skepticism concerning the ability of load disaggregation products to accurately identify and estimate energy consumption of end-uses; which has hindered wide-spread market adoption. A contributing factor is that common test methods and metrics are not available to evaluate performance without having to perform large scale field demonstrations and pilots, which can be costly when developing such products. Without common and cost-effective methods of evaluation, more developed disaggregation technologies will continue to be slow to market and potential users will remain uncertain about their capabilities. This paper reviews recent field studies and laboratory tests of disaggregation technologies. Several factors are identified that are important to consider in test protocols, so that the results reflect real world performance. Potential metrics are examined to highlight their effectiveness in quantifying disaggregation performance. This analysis is then used to suggest performance metrics that are meaningful and of value to potential users and that will enable researchers/developers to identify beneficial ways to improve their technologies.

Mayhorn, Ebony T.↗

Suggested Modifications for Bifacial Capacity Testing: Preprint

Capacity tests such as those described in ASTM 2848 and IEC 61724-2 are widely used during the contracting and acceptance testing of PV systems. With the increasing deployment of bifacial PV modules, there is a need to develop a standardized approach to capacity test these systems. Although variability and bias error was inherently higher for the measured capacity of bifacial systems, it could be reduced to a level consistent with the monofacial reference system by appropriate incorporation of rear irradiance- either measured or modeled. Three field installations provided bifacial system capacity that was measured with a mean bias error and standard deviation within 1% over the 2-10 month observation period. Capacity test accuracy could be improved further by utilizing measured back-of-module temperature and the IEC 61724-2 test method.

14 SOLAR ENERGY↗

Electric Vehicle Communications Standards Testing and Validation - Phase II: SAE J2931/1

Vehicle to grid communication standards enable interoperability among vehicles, charging stations and utility providers and provide the capability to implement charge management. Several standards initiatives by the Society of Automobile Engineers (SAE), International Standards Organization and International Electrotechnical Commission (ISO/IEC), and ZigBee/HomePlug Alliance are developing requirements for communication messages and protocols. Recent work by the Electric Power Research Institute (EPRI) in collaboration with SAE and automobile manufacturers has identified vehicle to grid communication performance requirements and developed a test plan as part of SAE J2931/1 committee work. This laboratory test plan was approved by the SAE J2931/1 committee and included test configurations, test methods, and performance requirements to verify reliability, robustness, repeatability, maximum communication distance, and authentication features of power line carrier (PLC) communication modules at the internet protocol layer level. The goal of the testing effort was to select a communication technology that would enable automobile manufacturers to begin the development and implementation process. The EPRI/Argonne National Laboratory (ANL)/Pacific Northwest National Laboratory (PNNL) testing teams divided the testing so that results for each test could be presented by two teams, performing the tests independently. The PNNL team performed narrowband PLC testing including the Texas Instruments (TI) Concerto, Ariane Controls AC-CPM1, and the MAXIM Tahoe 2 evaluation boards. The scope of testing was limited to measuring the vendor systems communication performance between Electric Vehicle Support Equipment (EVSE) and plug-in electric vehicles (PEV). The testing scope did not address PEV’s CAN bus to PLC or PLC to EVSE (Wi-Fi, cellular, PLC Mains, etc.) communication integration. In particular, no evaluation was performed to delineate the effort needed to translate the IPv6/SEP2.0 messages to PEV’s CAN bus. The J2931/1 laboratory test results were presented to the SAE membership on March 20-22, 2012. The SAE committee decided to select HomePlug GreenPHY (HPGP) as the communication technology to use between the PEV and EVSE. No technology completely met all performance requirements. Both the MAXIM Tahoe 2 and TI Concerto met the 100Kbps throughput requirement, are estimated to meet the latency measurement performance, and met the control pilot impairment requirements. But HPGP demonstrated the potential to provide a data throughput rate of 10x of the requirement and either met or showed the potential to meet the other requirements with further development.

33 ADVANCED PROPULSION SYSTEMS↗

Tailored Core Shell Cathode Powders for Solid Oxide Fuel Cells

In this Phase I SBIR project, a “core-shell” composite cathode approach was evaluated for improving SOFC performance and reducing degradation of lanthanum strontium cobalt ferrite (LSCF) cathode materials, following previous successful demonstrations of infiltration approaches for achieving the same goals. The intent was to establish core-shell cathode powders that enabled high performance to be obtained with “drop-in” process capability for SOFC manufacturing (i.e., rather than adding an infiltration step to the SOFC manufacturing process). Milling, precipitation and hetero-coagulation methods were evaluated for making core-shell composite cathode powders comprised of coarse LSCF “core” particles and nanoscale “shell” particles of lanthanum strontium manganite (LSM) or praseodymium strontium manganite (PSM). Precipitation and hetero-coagulation methods were successful for obtaining the targeted core-shell morphology, although perfect coverage of the LSCF core particles by the LSM and PSM particles was not obtained. Electrochemical characterization of core-shell cathode powders and conventional (baseline) cathode powders was performed via electrochemical impedance spectroscopy (EIS) half-cell measurements and single-cell SOFC testing. Reliable EIS testing methods were established, which enabled comparative area-specific resistance measurements to be obtained. A single-cell SOFC testing approach also was established that enabled cathode resistance to be separated from overall cell resistance, and for cathode degradation to be separated from overall cell degradation. The results of these EIS and SOFC tests conclusively determined that the core-shell cathode powders resulted in significant lowering of performance, compared to the baseline cathodes. Based on the results of this project, it was concluded that the core-shell cathode approach did not warrant further investigation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WE-E-18A-11: Fluoro-Tomographic Images From Projections of On-Board Imager (OBI) While Gantry Is Moving

Purpose: A method to generate a series of fluoro-tomographic images (FTI) of the slice of interest (SOI) from the projection images of the On-board imager (OBI) while gantry is moving is developed and tested. Methods: Tomographic image via background subtraction, TIBS has been published by our group. TIBS uses a priori anatomical information from a previous CT scan to isolate a SOI from a planar kV image by factoring out the attenuations by tissues outside the SOI (background). We extended the idea to 4D TIBS, which enables to generate from the projection of different gantry angles. A set of background images for different angles are prepared. A background image at a given gantry angle is subtracted from the projection image at the same angle to generate a TIBS image. Then the TIBS image is converted to a reference angle. The 4D TIBS is the set of TIBS that originated from gantry angles other than the reference angle. Projection images of lung patients for CBCT acquisition are used to test the 4D TIBS. Results: Fluoroscopic images of a coronal plane of lung patients are acquired from the CBCT projections at different gantry angles and times. Change of morphology of hilar vessels due to breathing and heart beating are visible in the coronal plane, which are generated from the set of the projection images at gantry angles other than antero-posterior. Breathing surrogate or sorting process is not needed. Unlike tomosynthesis, FTI from 4D TIBS maintains the independence of each of the projections thereby reveals temporal variations within the SOI. Conclusion: FTI, fluoroscopic imaging of a SOI with x-ray projections, directly generated from the x-ray projection images at different gantry angles is tested with a lung case and proven feasible. This technique can be used for on-line imaging of moving targets. NIH Grant R01CA133539.

60 APPLIED LIFE SCIENCES↗

Stirred-Reactor Coupon Analysis: An International Round Robin Study

The objective of this task was to determine the precision of the SRCA technique when used to determine the dilute condition corrosion rate. To this end, an interlaboratory round robin study was conducted per the instructions in ASTM Practice E691 to measure the precision with which the SRCA test method can be conducted. Twelve independent labs from eleven different institutions each evaluated four glass compositions in three different conditions. The ASTM procedures recommend at least 6 labs participate in a round robin testing the same 3 materials in the same conditions to determine precision. In this case, 12 labs each performed 12 independent tests. This was only possible thanks to the multi-glass testing capability of the SRCA test. A total of 108 duplicate pairs were used to calculate the repeatability of the tests, with the same glass tested in the same vessel, producing as identical conditions as possible for the replicates. These test results were quite tightly clustered, with a median difference from the average value of the pair of only 2.9%. Based on the calculations outlined in ASTM E177-20 and a measured standard deviation of 4.74%, the intralaboratory repeatability limit (r) was calculated to be within 13.3% of the expected value with 95% confidence level. The reproducibility limit (R) of the test was examined using all 277 data points from the round robin. Because of the differences in dissolution rates due to pH variability and intrinsically for the 12 conditions tested, the reproducibility limits for each condition and overall were calculated from the percent relative residual value for each test. The SRCA test is expected to be reproducible within 64% of the expected value with a 95% confidence level.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultra-High Operation Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing: Test Facility & Performance Evaluations

Solar Heat for Industrial Processes (SHIP) cavity receivers are capable of generating electricity or industrial process heat by absorbing thermal energy from solar radiation, focused on a small area. The concentration of solar radiation on the small area of the receiver enables the achievement of high temperatures (ranging from 400°C to 1,100°C) of a working fluid, thus making the SHIP technology thermodynamically comparable with conventional power plants. A volumetric receiver consists of a porous structure-generally made of silicon carbide or metal, which absorbs solar radiation and converts it into heat energy. Heat energy from the porous materials is then transferred to the fluid following through them. A volumetric receiver acts as a convective heat exchanger, transferring heat to the fluid through convection. Open-loop volumetric receivers work with air at atmospheric pressure and are suitable for single-cycle or multi-cycle energy plants. A Model Based Systems Engineering (MBSE) approach was used to develop a test bed at Sandia national Laboratories (SNL) capable of demonstrating an open-loop volumetric air receiver developed by General Electric Aerospace (GE Aerospace). This paper presents the development of the various MBSE methods, test bed, and testing operations for the GE air receiver, which was experimentally demonstrated to achieve 1,350°C for over 3 hours of operation and an approximate 70% receiver efficiency. By being able to achieve such high temperatures >1,000°C, this work provides the potential to support many SHIP industrial use cases.

14 SOLAR ENERGY↗

Evaluation Of Automated Low-Field Nuclear Magnetic Resonance (NMR) Relaxometry For Analysis Of Silicone Polymers

Screening studies and Design of Experiments (DoE) were performed to evaluate measurement variation of a new, non-destructive Nuclear Magnetic Resonance (NMR) test system designed to assess age-induced degradation of Outer Pressure Pads (OPP). The test method and results from 54,275 measurements are described. A reduction in measurement error was obtained after metal support struts were replaced with plastic support struts adjacent to the front position of the test chamber. However, remaining interference and a lack of detecting any age-related degradation prevent the use of the NMR system as a non-destructive surveillance test for OPPs. A cursory evaluation of the system with cellular silicone samples obtained more uniform results with increased error as measurements approached the sample’s edge.

36 MATERIALS SCIENCE↗

Live Operation Data Collection Optimization and Communication for the Domestic Nuclear Detection Office’s Rail Test Center

For the Domestic Nuclear Detection Office’s Rail Test Center (i.e., DNDO’s RTC), port operation knowledge with flexible collection tools and technique are essential in both technology testing design and implementation intended for live operational settings. Increased contextual data, flexibility in procedures, and rapid availability of information are keys to addressing the challenges of optimization, validation, and analysis within live operational setting data collection. These concepts need to be integrated into technology testing designs, data collection, validation, and analysis processes. A modified data collection technique with a two phased live operation test method is proposed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗