Real-time downhole measurement of ionic tracer concentration and pH in geothermal reservoirs.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Pressure gain combustion (PGC) seeks to convert fuel’s chemical energy simultaneously into thermal energy and mechanical energy, thereby reducing the entropy production in the process. Recent research has shown that the rotating detonation combustion or combustor (RDC) can provide excellent specific thrust, specific impulse, and large pressure gain through rapid energy release by continuous detonation in the circumferential direction. However, few past studies have employed fuels relevant to power generation gas turbines, since RDC research has focused mainly on aerospace applications. In this study, we present experimental results from RDC operated on methane and oxygen-enriched air to represent reactants used in gas turbines for land-based power generation. The RDC is operated at high pressures by placing a back-pressure plate downstream of the annular combustor. We apply time-resolved particle image velocimetry (PIV) technique, for the first time, to quantify the RDC exit flow at framing rate of 30 kHz. Results show that even though the exit flow is dominantly axial, a significant circumferential velocity component is also present, highlighting the need to condition the flow between RDE exit and turbine inlet. The flow field undergoes cyclic fluctuations, and the key features of the flow field repeat during each cycle. Interestingly, the circumferential velocity shows a reversal in the direction during the cyclic process. Results also show noticeable cycle-to-cycle variations, related to changes in the detonation wave speed, ultimately caused by the rapid fuel-air mixing process at the RDC inlet prior to detonation.
Abstract not provided.
A new laboratory system for studying the microbiological corrosion of decommissioning waste was designed and developed during this project. The material in this part of the laboratory studies was carbon steel (AISI/SAE 1005/UNS G10050). In order to estimate the corrosive effects of microbial activity both biotic and abiotic (containing the biocides methyl-isothiazolinone and glutaraldehyde) mesocosms were prepared. To enhance the effects of sulfate reducing bacteria an enrichment of these bacteria isolated from the native drill hole water from the repository site was inoculated in to the biotic mesocosms. Microbiological corrosion was studied using new electrochemical technologies, such as multi-electrode arrays sensors, and molecular biology methods in the laboratory. (authors)
Explore the source record for details and available documents.
Excellent phase stability of the drive laser is a critical performance specification of photoinjectors such as Fermilab's A0 photoinjector (A0PI). Previous efforts based on the measurement of the power spectrum of the signal of a fast photodiode illuminated by the mode locked infrared laser pulse component indicated a phase jitter of less than 1.4 ps (technique limited). A recently procured dual sweep plugin unit and existing Hamamatsu C5680 streak camera were used to study the phase stability of the UV laser pulse component. Initial measurements with the synchroscan vertical sweep unit locked to 81.25 MHz showed that the phase slew through the micropulse train and the phase jitter micropulse to micropulse were two key aspects that could be evaluated. The phase slew was much less than 100 fs per micropulse, and the total phase jitter (camera, trigger, and laser) was approximately 300 fs RMS for measurements of 50-micropulse trains. Data on the macropulse phase stability were also obtained. A possible upgrade to achieve better phase stability will be also discussed.
The prototype for a simultaneous measurement of two conjugate variables was originally introduced by Arthurs and Kelly in 1965. It relies on coupling the quantum particle to be probed to two additional systems, which serve as measurement pointers. In this contribution we investigate an extended scheme to measure position and momentum of a massive particle. By considering an explictly time-dependent coupling we can quantify the timing of the measurement. We investigate how the noise resulting from such a measurement process depends on the interaction strength and the size of the pointers. In particular, we focus on the question of which measurement timing minimizes the corresponding uncertainty product.
Shock tube experiments measured hydrogen-air induction times near the second explosion limit. By matching these experimental results with numerically predicted induction times, the rate coefficient for the reaction H + O2 + M = HO2 + M was evaluated as k-sub 4,N2 = 3.3 (plus or minus .6) x 10 to the 15 cm to the 6th/sq mole/s.
A low-power time-to-digital convertor (TDC) for an application inside a vacuum has been implemented based on the Wave Union TDC scheme in a low-cost field programmable gate array (FPGA) device. Bench top tests have shown that a time measurement resolution better than 30 ps (standard deviation of time differences between two channels) is achieved. Special firmware design practices are taken to reduce power consumption. The measurements indicate that with 32 channels fitting in the FPGA device, the power consumption on the FPGA core voltage is approximately 9.3 mW/channel and the total power consumption including both core and I/O banks is less than 27 mW/channel.
For explosive systems that exhibit gaps or cracks between their internal components (either by design or mechanical failure), measurable time delays exist for detonation waves crossing them. Reinitiation across such gaps is dependent on the type of explosive, gap width, gap morphology, confinement, and temperature effects. To examine this reinitiation effect, a series of tests has been conducted to measure the time delay across a prescribed gap within an 'infinitely' confined PBX 9501 system. Detonation breakout along the explosive surface is measured with a streak camera, and flow features are examined during reinitiation near the gap. Such tests allow for quantitative determination of the time delay corresponding to the time of initiation across a given gap oriented normal to the direction of the detonation wave. Measured time delays can be compared with numerical calculations, making it possible to validate initiation models as well as estimate detonation run-up distances. Understanding this reinitiation behavior is beneficial for the design and evaluation of explosive systems that require precision timing and performance.
We report results from continued timing observations of PSR J0740+6620, a high-mass, 2.8 ms radio pulsar in orbit with a likely ultracool white dwarf companion. Our data set consists of combined pulse arrival-time measurements made with the 100 m Green Bank Telescope and the Canadian Hydrogen Intensity Mapping Experiment telescope. We explore the significance of timing-based phenomena arising from general relativistic dynamics and variations in pulse dispersion. When using various statistical methods, we find that combining∼1.5 yr of additional, high-cadence timing data with previous measurements confirms and improves on previous estimates of relativistic effects within the PSR J0740+6620 system, with the pulsar mass=-+mM2.08p0.070.07 M (68.3% credibility) determined by the relativistic Shapiro time delay. For the first time, we measure secular variation in the orbital period and argue that this effect arises from apparent acceleration due to significant transverse motion. After incorporating contributions from Galactic differential rotation and off-plane acceleration in the Galactic potential, we obtain a model-dependent distance of=-+d1.140.150.17kpc (68.3% credibility). This improved distance confirms the ultracool nature of the white dwarf companion determined from recent optical observations. We discuss the prospects for future observations with next-generation facilities, which will likely improve the precision on mp for J0740+6620 by an order of magnitude within the next few years
In this work, we present a planar laser-induced fluorescence (PLIF) system for measuring two-dimensional (2D), spatiotemporally resolved ion velocity distribution functions (IVDFs). A continuous-wave tunable diode laser produces a laser sheet that irradiates the plasma, and the resulting fluorescence is captured by an intensified CCD (ICCD) camera. Fluorescence images recorded at varying laser wavelengths are converted into 2D IVDFs using the Doppler shift principle. The developed diagnostic is implemented in an electron beam generated E × B plasma with a bulk plasma density of $\sim\!\!{10^{10}}{\text{c}}{{\text{m}}^{ - 3}}$ . The developed diagnostic is validated against a conventional single-point LIF method using photomultiplier tube-based detection, while significantly reducing the total measurement time by the number of spatial positions measured. The time-resolving capability of this diagnostic is tested by oscillating the plasma between two nominal operating modes with different density profiles and triggering the ICCD camera by the externally driven plasma oscillation. The measured 2D IVDF maps reveal several signatures of ion dynamics in this plasma source, including radially outflowing ions across the electric field and anomalous ion heating at the periphery, consistent with recent kinetic simulations and theoretical studies. A possible correlation between these ion kinetic features and rotating spoke structures is discussed.