Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TENNESSEE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Mobilization of mercury from contaminated creekbank soils

The industrial use of mercury (Hg) led to the contamination of numerous watersheds worldwide, including the East Fork Poplar Creek (EFPC) in Tennessee, USA. Mercury can accumulate in creek banks and floodplain soils and is mobilized into downstream environments due to erosion from precipitation and flooding. Here, this study aimed to evaluate the geochemical conditions contributing to the release of Hg from contaminated soils in this watershed. Bank soil samples from the EFPC watershed with total Hg concentrations ranging from 27.2 to 1,425 mg·kg −1 were used in a series of batch experiments with artificial creek water at a solid-to-solution ratio of 1:30 to assess Hg release. Additional experiments examined Hg release across different soil size fractions and solid-to-solution ratios, as well as the effect of dissolved organic matter and time on Hg mobilization. Mercury release ranged from 0.011 to 0.17% of the total soil Hg and is correlated with total Hg concentrations. Variations in release among size fractions suggested heterogeneous distribution of labile Hg species. Results indicated two distinct solubility regimes depending on solid-to-solution ratios. Dissolved organic matter enhanced Hg release, and time-dependent experiments showed that changes in mercury speciation could decrease dissolved Hg concentrations over time. Identifying conditions that promote Hg mobilization from contaminated soils improves our understanding of Hg fluxes into downstream environments. Key factors influencing mercury release include soil characteristics, water chemistry, and temporal changes in mercury speciation.

54 ENVIRONMENTAL SCIENCES↗

A disconnect between O horizon and mineral soil carbon - Implications for soil C sequestration

Changing inputs of carbon to soil is one means of potentially increasing carbon sequestration in soils for the purpose of mitigating projected increases in atmospheric CO{sub 2} concentrations. The effect of manipulations of aboveground carbon input on soil carbon storage was tested in a temperate, deciduous forest in east Tennessee, USA. A 4.5-year experiment included exclusion of aboveground litterfall and supplemental litter additions (three times ambient) in an upland and a valley that differed in soil nitrogen availability. The estimated decomposition rate of the carbon stock in the O horizon was greater in the valley than in the upland due to higher litter quality (i.e., lower C/N ratios). Short-term litter exclusion or addition had no effect on carbon stock in the mineral soil, measured to a depth of 30 cm, or the partitioning of carbon in the mineral soil between particulate- and mineral-associated organic matter. A two-compartment model was used to interpret results from the field experiments. Field data and a sensitivity analysis of the model were consistent with little carbon transfer between the O horizon and the mineral soil. Increasing aboveground carbon input does not appear to be an effective means of promoting carbon sequestration in forest soil at the location of the present study because a disconnect exists in carbon dynamics between O horizon and mineral soil. Factors that directly increase inputs to belowground soil carbon, via roots, or reduce decomposition rates of organic matter are more likely to benefit efforts to increase carbon sequestration in forests where carbon dynamics in the O horizon are uncoupled from the mineral soil.

54 ENVIRONMENTAL SCIENCES↗

Environmental and economic analysis of using SWAT to simulate the effects of switchgrass production on water quality in an impaired watershed

Future bioenergy demand will likely result in the conversion of significant amounts of crop and pasture/hay lands in the mid-south of US. The objective of this research is to analyze the effects of the large-scale land use conversion to switchgrass as a bioenergy feedstock on water quality and economic feasibility in Oostanaula Creek watershed in East Tennessee. The soil and water assessment tool (SWAT) model was first used to simulate nutrient loadings of current land use in the watershed. Statistical criteria such as Nash Suttcliffe efficiency (E) and R 2 were calculated for model calibration and validation. The calibrated SWAT model was then used to simulate the effect of the land use conversion from the entire current crop and pasture/hay lands to switchgrass production. Results show that the conversion reduces average annual watershed loadings of sediment, nitrate (NO 3 ), total nitrogen (TN), and total phosphorous (TP) by an estimated 77%, 62%, 34%, and 46%, respectively. Lastly, analysis of net present values of ten years of farm profits and cost-effectiveness ratios for abatement of nutrient loadings indicates that the land use conversion is economically feasible.

09 BIOMASS FUELS↗

How close are urban scale building simulations to measured data? Examining bias derived from building metadata in urban building energy modeling

Residential and commercial buildings in the United States accounted for 40% of total energy in 2020. Building energy modeling (BEM) is a useful tool that allows individuals, researchers, companies, or utilities to save energy by optimizing buildings through estimation of building technology savings and performance projection of building energy under various environmental conditions. Urban building energy modeling (UBEM) expands the scope beyond individual buildings to the buildings in a neighborhood, city, utility and more. Yet there is a knowledge gap in the literature as to how these models compare to measured data on an individual and aggregated basis. As UBEM data and methods continue to develop, it is important to consider the accuracy, bias, and limitations of the models. Here, nation-scale data and UBEM software suite named Automatic Building Energy Modeling (AutoBEM) was used to model 50,843 buildings in Chattanooga, Tennessee. The uncalibrated simulation results were compared to aggregated 15-minute electricity data for the year 2019 with visualizations highlighting sources of bias in building data and the AutoBEM framework while considering how they relate to other UBEM methods. Estimation of building type and year of constructions are found to be the major sources of bias. Accounting for the amount of conditioned area per building significantly improves the overall fit of the simulated energy use intensity. it was found that inherent variation in building energy use contributes to R 2 values between 0.008 and 0.095 across building types but slope values near 1 for the total number of buildings. This indicates the need for building aggregation for representative building energy modeling with data sources available at an urban scale while illustrating the need for additional individual building data and model improvement beyond the originally produced UBEM models for individual building analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing dynamic wireless charging for electric buses: A data-driven approach to infrastructure planning

The network configuration significantly impacts the performance of dynamic wireless charging (DWC) technology for electric buses. Here, this study presents a novel approach to planning charging infrastructure for public transit using data-driven nonconvex mixed-integer optimization. Integrating DWC and charging station technologies reveals a trade-off between enroute and stationary charging times. Our framework optimizes bus frequency settings and transmitter coil arrangements to minimize operational and infrastructure costs. A case study in Chattanooga, Tennessee, demonstrates the method's effectiveness in mitigating range anxiety and reducing charging expenses. This research implies that integrating DWC technology into public transit systems can enhance the feasibility and cost-effectiveness of electric bus operations, promoting sustainable urban mobility.

33 ADVANCED PROPULSION SYSTEMS↗

Mercury emission from terrestrial background surfaces in the eastern USA. II: Air/surface exchange of mercury within forests from South Carolina to New England

Mercury air/surface exchange was measured over litter-covered soils with low Hg concentrations within various types of forests along the eastern seaboard of the USA. The fieldwork was conducted at six forested sites in state parks in South Carolina, North Carolina, New Jersey, Pennsylvania, New York and Maine from mid-May to early June 2005. The study showed that the Hg air/surface exchange was consistently very low and similar (overall daytime mean flux = 0.2 0.9 ng m 2 h 1, n = 310, for all six sites monitored) with the various forest types. These flux values are comparable with those found in a year-long study in Tennessee (yearly daytime mean = 0.4 0.5 ng m 2 h 1), but lower than many previous flux results reported for background soils. The Hg fluxes at all sites oscillated around zero, with many episodes of deposition (negative fluxes) occurring in both daytime and nighttime. While there were particular days showing significant correlations among the Hg air/surface exchange and certain environmental parameters, perhaps because of the low fluxes encountered, few significant correlations were found for any particular day of sampling between the Hg flux and environmental parameters such as solar radiation, soil temperature, air temperature (little variability seen), relative humidity, and ambient air Hg concentrations. Factors driving the Hg exchange as previously found for enriched soils may not hold for these background litter-covered forest soils. The results suggest that spatial variations of the Hg air/surface exchange were small among these different forest types for this particular time of year.

Kuiken, Todd↗

Long-term sorption and desorption of uranium in saprolite subsoil with nanoporous goethite

Long-term (2–3 months) batch U(VI) sorption-desorption experiments were conducted to understand the long-term sorption-desorption behavior of U(VI) in saprolite subsoils from Oak Ridge Field Research Center (ORFRC), Tennessee, which contained naturally occurring nanoporous goethite. Three subsoil samples containing a range of dithionite-citrate-bicarbonate (DCB) extractable Fe oxide content (7138, 11,161, and 22,582 mg Fe/kg) were used for the experiments. Sorption of 50 μM U(VI) to the subsoils in the presence of Ca 2+ and HCO 3 - at circumneutral pH occurred rapidly during the first 2 days, after which slow U(VI) sorption continued over 3 months. U(VI) desorption from the soils by 10 mM NaHCO 3 solution exhibited an initial fast desorption step during the first 24 h, followed by slower desorption over a week. Sorption of 50 μM U(VI) for 1 day to 3 months in the presence or absence of Ca 2+ consistently resulted in higher U(VI) sorption to saprolite soil with higher amount of nanoporous goethite, while desorption of U(VI) for 1 week to 2 months was consistently lower in saprolite soil with higher amount of nanoporous goethite. Saprolite subsoils containing higher amounts of nanoporous goethite exhibited more resistant U(VI) desorption, and the proportions of irreversible U(VI) sorption increased with longer residence time with soils. These results indicates that more U(VI) became bound to the internal surfaces of nanoporous iron oxides during long-term sorption. This study suggests that naturally occurring nanoporous goethite may exert a significant role in controlling the mobility and transport of U(VI) in historically contaminated sites that have existed over decades.

54 ENVIRONMENTAL SCIENCES↗

Data, exergy, and energy analysis of a vertical-bore, ground-source heat pump to for domestic water heating under simulated occupancy conditions

Evidence is provided to support the view that greater than two-thirds of energy required to produce domestic hot water may be extracted from the ground which serves as renewable energy resource. The case refers to a 345 m2 research house located in Oak Ridge, Tennessee, 36.01 N 84.26 W in a mixed-humid climate with HDD of 2218 C-days (3993 F-days) and CDD of 723 C-days (1301 F-days). The house is operated under simulated occupancy conditions in which the hot water use protocol is based on the Building America Research Benchmark Definition (Hendron 2008; Hendron and Engebrecht 2010) which captures the water consumption lifestyles of the average family in the United States. The 5.275 (1.5-ton) water-to-water ground source heat pump (WW-GSHP) shared the same vertical bore with a 7.56 KW water-to-air ground source heat pump for space conditioning the same house. Energy and exergy analysis of data collected continuously over a twelve month period provide performance metrics and sources of inherent systemic inefficiencies. Data and analyses are vital to better understand how WW-GSHPs may be further improved to enable the ground to be used as a renewable energy resource.

15 GEOTHERMAL ENERGY↗

Climate change effects on soil microarthropod abundance and community structure

Long-term ecosystem responses to climate change strongly depend on how the soil subsystem and its inhabitants respond to these perturbations. Using open-top chambers, we studied the response of soil microarthropods to single and combined effects of ambient and elevated atmospheric [CO{sub 2}], ambient and elevated temperatures and changes in precipitation in constructed old-fields in Tennessee, USA. Microarthropods were assessed five years after treatments were initiated and samples were collected in both November and June. Across treatments, mites and collembola were the most dominant microarthropod groups collected. We did not detect any treatment effects on microarthropod abundance. In November, but not in June, microarthropod richness, however, was affected by the climate change treatments. In November, total microarthropod richness was lower in dry than in wet treatments, and in ambient temperature treatments, richness was higher under elevated [CO{sub 2}] than under ambient [CO{sub 2}]. Differential responses of individual taxa to the climate change treatments resulted in shifts in community composition. In general, the precipitation and warming treatments explained most of the variation in community composition. Across treatments, we found that collembola abundance and richness were positively related to soil moisture content, and that negative relationships between collembola abundance and richness and soil temperature could be explained by temperature-related shifts in soil moisture content. Our data demonstrate how simultaneously acting climate change factors can affect the structure of soil microarthropod communities in old-field ecosystems. Overall, changes in soil moisture content, either as direct effect of changes in precipitation or as indirect effect of warming or elevated [CO{sub 2}], had a larger impact on microarthropod communities than did the direct effects of the warming and elevated [CO{sub 2}] treatments. Moisture-induced shifts in soil microarthropod abundance and community composition may have important impacts on ecosystem functions, such as decomposition, under future climatic change.

54 ENVIRONMENTAL SCIENCES↗

Observations of Fine and Coarse Particle Nitrate at Several Rural Locations in the United States

Nitrate comprises an important part of aerosol mass at many non-urban locations during some times of the year. Little is known, however, about the chemical form and size distribution of particulate nitrate in these environments. While submicron ammonium nitrate is often assumed to be the dominant species, this assumption is rarely tested. Properties of aerosol nitrate were characterized at several IMPROVE monitoring sites during a series of field studies. Study sites included Bondville, Illinois (February 2003), San Gorgonio Wilderness Area, California (April and July 2003), Grand Canyon National Park, Arizona (May 2003), Brigantine National Wildlife Refuge, New Jersey (November 2003), and Great Smoky Mountains National Park, Tennessee (July/August 2004). Nitrate was found predominantly in submicron ammonium nitrate particles during the Bondville and San Gorgonio (April) campaigns. Coarse mode nitrate particles, resulting from reactions of nitric acid or its precursors with sea salt or soil dust, were more important at Grand Canyon and Great Smoky Mountains. Both fine and coarse mode nitrate were important during the studies at Brigantine and San Gorgonio (July). These results, which complement earlier findings about the importance of coarse particle nitrate at Yosemite and Big Bend National Parks, suggest a need to more closely examine common assumptions regarding the importance of ammonium nitrate at non-urban sites, to include pathways for coarse mode nitrate formation in regional models, and to consider impacts of coarse particle nitrate on visibility. Because coarse particle nitrate modes often extend well below 2.5 µm aerodynamic diameter, measurements of PM2.5 nitrate in these environments should not automatically be assumed to contain only ammonium nitrate.

54 ENVIRONMENTAL SCIENCES↗

Semi-Continuous Measurement of PM2.5 Ionic Composition at Several Rural Locations in the United States

To improve understanding of the nature and variability of the ionic fraction of atmospheric fine aerosol particles in non-urban environments, one to two month measurement campaigns were conducted at several rural locations in the United States. Study sites included Yosemite National Park (NP) (July – September 2002), Bondville, Illinois (February 2003), San Gorgonio Wilderness Area, California (April and July 2003), Grand Canyon NP, Arizona (May 2003), Brigantine National Wildlife Refuge (NWR), New Jersey (November 2003), and Great Smoky Mountains NP, Tennessee (July/August 2004). PM2.5 ion composition was measured at 15-minute intervals using a Particle Into Liquid Sampler (PILS) coupled to two ion chromatographs. Comparison of PILS measurements with parallel traditional 24-hr denuder/filter-pack measurements reveal generally good agreement between the two techniques, although PILS measurements of PM2.5 NH4+ appear to be biased slightly low. High-time resolution aerosol concentration measurements provide much better estimates of the range of aerosol concentration levels experienced at these rural locations. Ratios of peak 15-min to 24-hr nitrate concentrations, for example, ranged from 1.7 at Brigantine NWR to 7.0 at the Great Smoky Mountains NP. A strong influence of diurnal upslope/downslope transport patterns was observed on aerosol concentrations at several locations, including Yosemite NP, San Gorgonio Wilderness Area, and Great Smoky Mountains NP, with peak concentrations typically occurring during afternoon upslope transport. High time resolution aerosol composition measurements also provide new insight into relationships between individual aerosol species and the influence of environmental conditions on aerosol composition. Observations at several locations revealed important information about mechanisms of particle nitrate formation. At Yosemite and Grand Canyon NPs, for example, evidence was observed for reaction of nitric acid or its precursors with sea salt or soil dust. Observations from several sites also revealed the importance of aerosol acidity (Great Smoky Mountains NP, Bondville) and temperature/humidity (San Gorgonio, Bondville) on fine particle ammonium nitrate formation.

54 ENVIRONMENTAL SCIENCES↗

Innovative large overbraided carbon fiber composite beams in historical Friendship Bell Pavilion

The International Friendship Bell Pavilion located in the City of Oak Ridge, Tennessee symbolizes the spirit of the peace and friendship shared by the city of Oak Ridge and city of Naka, Japan. The Bell Pavilion features an 8000-pound bronze cast bell along with futuristic materials and advanced manufacturing technologies. The team has developed innovative overbraided carbon fiber arched beams in conjunction with the bronze bell. Carbon fiber was utilized in these beams because of its lightweight, strong, stiff, and durable characteristics. A sandwich design used a high-performance foam core, overbraided with triaxial carbon fibers. This is the world’s largest overbraided composite structure for parks and recreation. For the first time in such an application, 17 free floating, 33-foot (10 m) long arched carbon fiber composite beams cantilever from a central concrete-steel superstructure over the bronze bell. The arc radius of the bottom of each beam is uniquely different giving an appearance of an open dome when standing underneath the structure.

Parks and Recreation↗

Stochastic optimization of cellulosic biofuel supply chain incorporating feedstock yield uncertainty

The global goal to reduce dependence on fossil fuels and to mitigate greenhouse gas emissions has resulted in research focused on environment friendly and socio-economically sustainable renewable energy sources. However, commercial production of bio-energy is constrained by biomass supply uncertainty and associated costs. This study presents an integrated approach to determining the optimal biofuel supply chain considering biomass yield uncertainty. A two-stage stochastic mixed integer linear programming is utilized to minimize the expected system cost while incorporating yield uncertainty in the strategic level decisions related to biomass production and biorefinery investment. Applicability of the stochastic model is illustrated through a case study of switchgrass-based biofuel in west Tennessee.

09 BIOMASS FUELS↗

Field test and simulation evaluation of variable refrigerant flow systems performance

Our study aims to compare the performance of a Variable Refrigerant Flow (VRF) system with a Roof Top Unit, (RTU) and a variable-air-volume (VAV) system through field tests and energy simulations. The field test was conducted in as similar conditions as possible between the two systems, such as the installation and operating environments of heating, the ventilation and air conditioning (HVAC) system, including internal heat gain and outdoor conditions, including buildings to compare the performance of the two systems accurately. A VRF system and RTU were installed at the test building located in Oak Ridge, Tennessee, in the USA. The same internal heat gain was generated at the same operating time of the two systems using lighting, electric heaters, and humidifiers inside the building. The HVAC system was alternately operated between cooling and heating operations to acquire energy performance data and to compare energy usage. Furthermore, an hourly building energy simulation model was developed with regard to the VRF system and RTU, and then the model was calibrated using actual measured data. Then, annual energy consumption of the two systems were compared and analyzed using the calibrated model. Moreover, additional analysis was conducted when the controlled discharge air temperature in the RTU was changed. The field test result showed that when energy consumptions of two systems were compared at the same outdoor conditions, using the weather-normalized model, the VRF system exhibited an energy reduction of approximately 17% during cooling operation and of approximately 74% during heating operations. A comparison on the annual energy consumption using simulations showed that the VRF system reduced energy consumption more than that of the RTU by 60%. Furthermore, when the discharge air temperature in the RTU was controlled according to the outdoor air temperature, energy consumption of the RTU was reduced by 6% in cooling operations and by 18% in heating operation. As a result, energy consumption of the VRF system was reduced by more than that of the RTU by 55% approximately.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peak cooling load shift capability of a thermal energy storage system integrated with an active insulation system in US climate zones

This study aims to evaluate a thermal energy storage (TES) system integrated with an active insulation system (AIS) to form a TES + AIS integrated wall system as a partition and as a secondary cooling system to shift the peak load and reduce cooling energy consumption. To understand and demonstrate its cooling performance, the TES + AIS integrated wall system was installed in an office building in Oak Ridge, Tennessee. To investigate the effect of the TES + AIS integrated wall system in a typical office building and various climate zones, the US Department of Energy’s prototype office building model was modified to accommodate the proposed system. In this work, results showed that the minimum size of the proposed system to achieve energy savings varies depending on climate conditions. The minimum size of the proposed system for cooling energy saving and shifting peak cooling demand in climate zones 2, 3, and 5 is 29.7 m 2 , whereas it is 44.6 m 2 in zones 4 and 6. By installing the minimum size of the proposed system, 11.3 % to 16.4 % of cooling energy can be shifted during discharge hours in a representative summer day.

25 ENERGY STORAGE↗

Energy performance evaluation of the ASHRAE Guideline 36 control and reinforcement learning–based control using field measurements

This study evaluates the energy performance of ASHRAE Guideline 36–compliant control (ASHRAE 36 control) and reinforcement learning (RL)–based control through experimental field tests and a simulation study. Three field tests were conducted at Oak Ridge National Laboratory’s commercial building test facility in Oak Ridge, Tennessee: a baseline with a baseline conventional control, a test with ASHRAE 36 control, and a test with RL-based control. The selected ASHRAE 36 controls were trim and respond control, as well as variable air volume (VAV) box control. We compared the measured supply air temperature of the rooftop unit, VAV box supply air temperature, and VAV box supply airflow rate across the three test cases. The field data indicated that ASHRAE 36 controls operated as specified by ASHRAE Guideline 36. Based on these data, ASHRAE 36 control achieved a 45 % reduction in hourly averaged HVAC energy consumption compared with the baseline, and RL-based control achieved a 66 % reduction. These potential annual energy savings were confirmed using a calibrated whole-building energy model. Compared with the baseline, ASHRAE 36 control reduced HVAC energy consumption by 42 %, and RL-based control achieved a 54 % reduction. Furthermore, RL-based control reduced total HVAC energy consumption by 21 % more than ASHRAE 36 control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling thermal energy storage with a thermally anisotropic building envelope for building demand-side management across various US climate conditions

Here, the thermally anisotropic building envelope (TABE) is a novel active building envelope that enhances energy efficiency and thermal comfort in buildings by transferring heat and cold between building envelopes and hydronic loops. When coupled with thermal energy storage (TES) units, the TABE + TES enables the storage of both heat and cold energy captured by the TABE roof or exterior walls. This stored energy can be later released by the TABE floor for indoor heating and cooling, benefiting both the grid and the end user. This paper evaluates the merits of TABE + TES for building demand-side management across various US climate conditions, focusing on peak load shaving, annual energy savings, and cost savings under time-of-use (TOU) electric rate schedules. Simulations were conducted by integrating time-of-day–informed, rule-based control strategies in MATLAB, TABE components and TES units in COMSOL Multiphysics, and whole-building energy analysis in EnergyPlus. A case study using the US Department of Energy’s prototype single-family detached house model in Birmingham, Alabama; Los Angeles, California; Oak Ridge, Tennessee; and Denver, Colorado, showed that the TABE + TES system achieved (1) 70 % peak load shaving in Los Angeles and Denver and 20 % in Birmingham and Oak Ridge; (2) significant peak electricity savings of 351–497 kWh, reducing peak energy consumption by 38 %–78 %; and (3) annual heating cost savings of 0.79 $\$$/m2–1.17 $\$$/m 2 and cooling cost savings of 0.60 $\$$/m 2 –1.17 $\$$/m 2 using a normal utility rate or low-TOU rate. The benefits of employing the TABE + TES system are even more significant under high TOU rates.

25 ENERGY STORAGE↗

Deploying advanced supervisory control strategies to small- and medium-sized commercial buildings: Case study and lessons learned

Deploying advanced supervisory control strategies (ASCSs) in small- and medium-sized commercial buildings (SMBs) is vital but faces two issues: (1) a lack of building control and communication infrastructure (BCCI) in SMBs and (2) the significant engineering efforts required to implement and configurate ASCSs. Despite hindering the large-scale adoption of ASCSs in SMBs, these issues have not been adequately explored in the literature, which tends to focus more on feasibility than scalability. This paper provides a comprehensive evaluation of these two issues through a case study of an occupied SMB in eastern Tennessee of the United States. Specifically, we design and implement a BCCI for the studied building with commercial off-the-shelf products to accommodate the needs for deploying ASCSs. Here, we then deploy two ASCSs—a rule-based setback control and a model predictive control (MPC)—with the BCCI and evaluate their performance throughout the summer of 2024. This study reveals that the main bottlenecks in establishing BCCIs for SMBs are the high initial cost (∼$56/m 2 ) and communication delays (up to 9 min). Additionally, the assessment of the two ASCSs indicates that the majority (∼75 %) of the engineering effort required for implementation and configuration is spent on model identification, debugging, and tuning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗