Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stimulus responsive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Clinical Aspects of the Control of Plasma Volume at Microgravity and During Return to One Gravity

Plasma volume is reduced by 10%-20% within 24 to 48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity-induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced VO2max after return to one gravity (1G). Since there is no evidence to suggest plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual spaceflight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a 'resetting' to a lower operating point which acts to limit plasma volume expansion during attempts to increase fluid intake. In groudbase and spaceflight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline 10 operating point. Fluid-loading and LBNP have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective countermeasures for the control of plasma volume in microgravity and during return to one gravity will depend upon testing that can be conducted under standardized controlled baseline condi

Convertino, Victor A.↗

IMS Rapid Response FY21 Summary Report for: Integrating Patterned Probes with Four-Dimensional Scanning Transmission Electron Microscopy for Unrivaled Crystallographic Structure Determination in Nanomaterials

The initial goal of our 4-dimensional scanning transmission electron microscopy (4D-STEM)-based project was to develop strain resolution two orders of magnitude better than what is now currently possible with electron-based scattering techniques, all while collecting scattering information from 7 different tilt axes at one time [multi-beam electron diffraction (MBED)1 ] through the development of a new electron probe-forming aperture with non-circular features (patterned probes 2 ). We set out to accomplish this through a collaboration with Drs. Colin Ophus and Ben Savitsky at Lawrence Berkeley Laboratory (they are the world-leading experts in developing the complex computational codes required to perform orientation analysis and quantitative strain mapping on our 4D-STEM data sets. We are motivated to invest in this area as it will be the only technique sensitive enough to perform three- dimensional automated crystallographic orientation mapping (ACOM) and strain mapping for materials exposed to external stimulus (a focus of our larger efforts).

36 MATERIALS SCIENCE↗

Soleus H-reflex gain in humans walking and running under simulated reduced gravity

The Hoffmann (H-) reflex is an electrical analogue of the monosynaptic stretch reflex, elicited by bypassing the muscle spindle and directly stimulating the afferent nerve. Studying H-reflex modulation provides insight into how the nervous system centrally modulates stretch reflex responses.A common measure of H-reflex gain is the slope of the relationship between H-reflex amplitude and EMG amplitude. To examine soleus H-reflex gain across a range of EMG levels during human locomotion, we used simulated reduced gravity to reduce muscle activity. We hypothesised that H-reflex gain would be independent of gravity level.We recorded EMG from eight subjects walking (1.25 m s-1) and running (3.0 m s-1) at four gravity levels (1.0, 0.75, 0.5 and 0.25 G (Earth gravity)). We normalised the stimulus M-wave and resulting H-reflex to the maximal M-wave amplitude (Mmax) elicited throughout the stride to correct for movement of stimulus and recording electrodes relative to nerve and muscle fibres. Peak soleus EMG amplitude decreased by ~30% for walking and for running over the fourfold change in gravity. As hypothesised, slopes of linear regressions fitted to H-reflex versus EMG data were independent of gravity for walking and running (ANOVA, P > 0.8). The slopes were also independent of gait (P > 0.6), contrary to previous studies. Walking had a greater y-intercept (19.9% Mmax) than running (-2.5% Mmax; P < 0.001). At all levels of EMG, walking H-reflex amplitudes were higher than running H-reflex amplitudes by a constant amount. We conclude that the nervous system adjusts H-reflex threshold but not H-reflex gain between walking and running. These findings provide insight into potential neural mechanisms responsible for spinal modulation of the stretch reflex during human locomotion.

Non-NASA Center↗

Vasopressin responses to unloading arterial baroreceptors during cardiac nerve blockade in conscious dogs

We examined the relative contributions of afferent input from the heart and from arterial baroreceptors in the stimulation of arginine vasopressin (AVP) secretion in response to hypotension caused by thoracic inferior vena caval constriction (TIVCC). Afferent input from cardiac receptors was reversibly blocked by infusing 2% procaine into the pericardial space to anesthetize the cardiac nerves. Acute cardiac nerve blockade (CNB) alone caused a rise in mean arterial pressure (MAP) of 24 +/- 3 mmHg but no change in plasma AVP. If the rise in MAP was prevented by TIVCC, plasma AVP increased by 39 +/- 15 pg/ml, and if MAP was allowed to increase and then was forced back to control by TIVCC, plasma AVP increased by 34 +/- 15 pg/ml. Thus the rise in MAP during CNB stimulated arterial baroreceptors, which in turn compensated for the loss of inhibitory input from cardiac receptors on AVP secretion. These results indicate that the maximum secretory response resulting from complete unloading of cardiac receptors at a normal MAP results in a mean increase in plasma AVP of 39 pg/ml in this group of dogs. When MAP was reduced 25% below control levels (from 95 +/- 5 to 69 +/- 3 mmHg) by TIVCC during pericardial saline infusion, plasma AVP increased by 79 +/- 42 pg/ml. However, the same degree of hypotension during CNB (MAP was reduced from 120 +/- 5 to 71 +/- 3 mmHg) led to a greater (P less than 0.05) increase in plasma AVP of 130 +/- 33 pg/ml. Because completely unloading cardiac receptors can account for an increase of only 39 pg/ml on average in this group of dogs, the remainder of the increase in plasma AVP must be due to other sources of stimulation. We suggest that the principal stimulus to AVP secretion after acute CNB in these studies arises from unloading the arterial baroreceptors.

NASA Center ARC↗

Debonding-on-demand reversible adhesives via heat or light with competitive adhesion strength to conventional epoxy adhesives

Stimuli responsive debonding-on-demand (DoD) reversible adhesives are of great interest for the circular economy. However, the reversible adhesives developed so far often lack competitive adhesion strength in a bonding state. In this work, reversible epoxy adhesives based on Diels–Alder (DA) chemistry were developed and exhibited a competitive adhesion strength (e.g., 12 – 16 MPa of a lap shear strength) to commercial non-reversible epoxy adhesives. The reversible epoxy formulation showed superior thermal stability up to 110°C, and transition to a debonding state in the order of 0.1 MPa at 140°C, consequently, an on/off-type debonding behavior. The transition to a debonding state was attributed to crosslinking density control (e.g., decrease by 33% – 49%) through the reversible DA chemistry and the proximity to the glass transition. Next, for debonding by light stimulus, photothermal refractory plasmonic titanium nitride (TiN) nanoparticles were incorporated in the reversible epoxy, which can generate the required heat for debonding upon exposure to visible light. Photothermal debonding allows for precise debonding at target areas and tunable adhesion strength by controlling the exposure area and light intensity. The DA adhesive formulations containing 0.5 wt.% TiN nanoparticles presented a debonding state with zero adhesion under light exposure with intensity of 1670 mW/cm 2 (inducing 140°C). Even after three cycles of reattachment, the DA adhesive formulations retained 96% of the pristine sample’s adhesion strength measured at 110°C. Therefore, the DA adhesives are attractive candidates as reversible DoD systems applicable in higher temperatures.

42 ENGINEERING↗

The Role of Linear Acceleration in Visual-Vestibular Interactions and Implications in Aircraft Operations

While considerable attention has been given to visual-vestibular interaction (VVI) during angular motion of the head as might occur during an aircraft spin, much less attention has been given to VVI during linear motion of the head. Such interaction might occur, for example, while viewing a stationary or moving display during vertical take-off and landing operations Research into linear VVI, particularly during prolonged periods of linear acceleration, has been hampered by the unavailability of a programmable translator capable of large excursions We collaborated with Otis Elevator Co. and used their research tower and elevator, whose motion could be digitally programmed, to vertically translate human subjects over a distance of 92.3 meters with a peak linear acceleration of 2 meters/sec(exp 2) During pulsatile or sinusoidal translation, the subjects viewed moving stripes (optokinetic stimulus) or a fixed point source (light emitting diode, led, display), respectively and it was generally found that. The direction of linear acceleration relative to the cardinal head axes and the direction of the slow component of optokinetic nystagmus (OKN) determined the extent of VVI during concomitant stripe motion and linear acceleration. Acceleration along the z head axis (A(sub z)) produced the largest VVI, particularly when the slow component of OKN was in the same direction as eye movements produced by the linear acceleration and Eye movements produced by linear acceleration are suppressed by viewing a fixed target at frequencies below 10 Hz But, above this frequency the suppression produced by VVI is removed. Finally, as demonstrated in non-human primates, vergence of the eyes appears to modulate the vertical eye movement response to linear acceleration in humans.

Correia, Manning J.↗

Clinical aspects of the control of plasma volume at microgravity and during return to one gravity

Plasma volume is reduced by 10-20% within 24-48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced maximal oxygen uptake (VO2max) after return to one gravity (1G). Since there is no evidence to suggest that plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual space flight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a "resetting" to a lower operating point, which acts to limit plasma volume expansion during attempts to increase fluid intake. In ground based and space flight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline IG operating point. Fluid-loading and lower body negative pressure (LBNP) have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other hand, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective counter measures for the control of plasma volume in microgravity and during return to IG will depend upon testing that can be conducted under standardized controlled baseline conditions during both ground-based and space flight investigations.

Review, Tutorial↗

The kinetics of root gravitropism: dual motors and sensors

The Cholodny-Went theory of tropisms has served as a framework for investigation of root gravitropism for nearly three quarters of a century. Recent investigations using modern techniques have generated findings consistent with the classical theory, including confirmation of asymmetrical distribution of polar auxin transport carriers, molecular evidence for auxin asymmetry following gravistimulation, and generation of auxin response mutants with predictable lesions in gravitropism. Other results indicate that the classical model is inadequate to account for key features of root gravitropism. Initiation of curvature, for example, occurs outside the region of most rapid elongation and is driven by differential acceleration rather than differential inhibition of elongation. The evidence indicates that there are two motors driving root gravitropism, one of which appears not to be auxin regulated. We have recently developed technology that is capable of maintaining a constant angle of gravistimulation at any selected target region of a root while continuously monitoring growth and curvature kinetics. This review elaborates on the advantages of this new technology for analyzing gravitropism and describes applications of the technology that reveal (1) the existence of at least two phases to gravitropic motor output, even under conditions of constant stimulus input and (2) the existence of gravity sensing outside of the root cap. We propose a revised model of root gravitropism including dual sensors and dual motors interacting to accomplish root gravitropism, with only one of the systems linked to the classical Cholodny-Went theory.

Review↗

Modification of Eccentric Gaze-Holding

Clear vision and accurate localization of objects in the environment are prerequisites for reliable performance of motor tasks. Space flight confronts the crewmember with a stimulus rearrangement that requires adaptation to function effectively with the new requirements of altered spatial orientation and motor coordination. Adaptation and motor learning driven by the effects of cerebellar disorders may share some of the same demands that face our astronauts. One measure of spatial localization shared by the astronauts and those suffering from cerebellar disorders that is easily quantified, and for which a neurobiological substrate has been identified, is the control of the angle of gaze (the "line of sight"). The disturbances of gaze control that have been documented to occur in astronauts and cosmonauts, both in-flight and postflight, can be directly related to changes in the extrinsic gravitational environment and intrinsic proprioceptive mechanisms thus, lending themselves to description by simple non-linear statistical models. Because of the necessity of developing robust normal response populations and normative populations against which abnormal responses can be evaluated, the basic models can be formulated using normal, non-astronaut test subjects and subsequently extended using centrifugation techniques to alter the gravitational and proprioceptive environment of these subjects. Further tests and extensions of the models can be made by studying abnormalities of gaze control in patients with cerebellar disease. A series of investigations were conducted in which a total of 62 subjects were tested to: (1) Define eccentric gaze-holding parameters in a normative population, and (2) explore the effects of linear acceleration on gaze-holding parameters. For these studies gaze-holding was evaluated with the subjects seated upright (the normative values), rolled 45 degrees to both the left and right, or pitched back 30 and 90 degrees. In a separate study the further effects of acceleration on gaze stability was examined during centrifugation (+2 G (sub x) and +2 G (sub z) using a total of 23 subjects. In all of our investigations eccentric gaze-holding was established by having the subjects acquire an eccentric target (+/-30 degrees horizontal, +/- 15 degrees vertical) that was flashed for 750 msec in an otherwise dark room. Subjects were instructed to hold gaze on the remembered position of the flashed target for 20 sec. Immediately following the 20 sec period, subjects were cued to return to the remembered center position and to hold gaze there for an additional 20 sec. Following this 20 sec period the center target was briefly flashed and the subject made any corrective eye movement back to the true center position. Conventionally, the ability to hold eccentric gaze is estimated by fitting the natural log of centripetal eye drifts by linear regression and calculating the time constant (G) of these slow phases of "gaze-evoked nystagmus". However, because our normative subjects sometimes showed essentially no drift (tau (sub c) = m), statistical estimation and inference on the effect of target direction was performed on values of the decay constant theta = 1/(tau (sub c)) which we found was well modeled by a gamma distribution. Subjects showed substantial variance of their eye drifts, which were centrifugal in approximately 20 % of cases, and > 40% for down gaze. Using the ensuing estimated gamma distributions, we were able to conclude that rightward and leftward gaze holding were not significantly different, but that upward gaze holding was significantly worse than downward (p<0.05). We also concluded that vertical gaze holding was significantly worse than horizontal (p<0.05). In the case of left and right roll, we found that both had a similar improvement to horizontal gaze holding (p<0.05), but didn't have a significant effect on vertical gaze holding. For pitch tilts, both tilt angles significantly decreased gaze-holding ility in all directions (p<0.05). Finally, we found that hyper-g centrifugation significantly decreased gaze holding ability in the vertical plane. The main findings of this study are as follows: (1) vertical gaze-holding is less stable than horizontal, (2) gaze-holding to upward targets is less stable than to downward targets, (3) tilt affects gaze holding, and (4) hyper-g affects gaze holding. This difference between horizontal and vertical gaze-holding may be ascribed to separate components of the velocity-to-position neural integrator for eye movements, and to differences in orbital mechanics. The differences between upward and downward gaze-holding may be ascribed to an inherent vertical imbalance in the vestibular system. Because whole body tilt and hyper-g affects gaze-holding, it is implied that the otolith organs have direct connections to the neural integrator and further studies of astronaut gaze-holding are warranted. Our statistical method for representing the range of normal eccentric gaze stability can be readily applied to normals who maybe exposed to environments which may modify the central integrator and require monitoring, and to evaluate patients with gaze-evoked nystagmus by comparing to the above established normative criteria.

Reschke, M. F.↗

Reinforcement expectation in the honeybee ( Apis mellifera ): Can downshifts in reinforcement show conditioned inhibition?

When animals learn the association of a conditioned stimulus (CS) with an unconditioned stimulus (US), later presentation of the CS invokes a representation of the US. When the expected US fails to occur, theoretical accounts predict that conditioned inhibition can accrue to any other stimuli that are associated with this change in the US. Empirical work with mammals has confirmed the existence of conditioned inhibition. But the way it is manifested, the conditions that produce it, and determining whether it is the opposite of excitatory conditioning are important considerations. Invertebrates can make valuable contributions to this literature because of the well-established conditioning protocols and access to the central nervous system (CNS) for studying neural underpinnings of behavior. Nevertheless, although conditioned inhibition has been reported, it has yet to be thoroughly investigated in invertebrates. Here, we evaluate the role of the US in producing conditioned inhibition by using proboscis extension response conditioning of the honeybee (Apis mellifera). Specifically, using variations of a “feature-negative” experimental design, we use downshifts in US intensity relative to US intensity used during initial excitatory conditioning to show that an odorant in an odor–odor mixture can become a conditioned inhibitor. We argue that some alternative interpretations to conditioned inhibition are unlikely. However, we show variation across individuals in how strongly they show conditioned inhibition, with some individuals possibly revealing a different means of learning about changes in reinforcement. We discuss how the resolution of these differences is needed to fully understand whether and how conditioned inhibition is manifested in the honeybee, and whether it can be extended to investigate how it is encoded in the CNS. It is also important for extension to other insect models. In particular, work like this will be important as more is revealed of the complexity of the insect brain from connectome projects.

60 APPLIED LIFE SCIENCES↗

Transience of the Retinal Output Is Determined by a Great Variety of Circuit Elements

Retinal ganglion cells (RGCs) encrypt stimulus features of the visual scene in action potentials and convey them toward higher visual centers in the brain. Although there are many visual features to encode, our recent understanding is that the ~46 different functional subtypes of RGCs in the retina share this task. In this scheme, each RGC subtype establishes a separate, parallel signaling route for a specific visual feature (e.g., contrast, the direction of motion, luminosity), through which information is conveyed. The efficiency of encoding depends on several factors, including signal strength, adaptational levels, and the actual efficacy of the underlying retinal microcircuits. Upon collecting inputs across their respective receptive field, RGCs perform further analysis (e.g., summation, subtraction, weighting) before they generate the final output spike train, which itself is characterized by multiple different features, such as the number of spikes, the inter-spike intervals, response delay, and the rundown time (transience) of the response. These specific kinetic features are essential for target postsynaptic neurons in the brain in order to effectively decode and interpret signals, thereby forming visual perception. We review recent knowledge regarding circuit elements of the mammalian retina that participate in shaping RGC response transience for optimal visual signaling.

59 BASIC BIOLOGICAL SCIENCES↗

Functional recovery of anterior semicircular canal afferents following hair cell regeneration in birds

Streptomycin sulfate (1.2 g/kg i.m.) was administered for 5 consecutive days to 5-7-day-old white Leghorn chicks; this causes damage to semicircular canal hair cells that ultimately regenerate to reform the sensory epithelium. During the recovery period, electrophysiological recordings were taken sequentially from anterior semicircular canal primary afferents using an indentation stimulus of the canal that has been shown to mimic rotational stimulation. Chicks were assigned to an early (14-18 days; n = 8), intermediate (28-34 days; n = 5), and late (38-58 days; n = 4) period based on days after treatment. Seven untreated chicks, 15-67 days old, provided control data. An absence of background and indent-induced discharge was the prominent feature of afferents in the early period: only "silent" afferents were encountered in 5/8 experiments. In several of these chicks, fascicles of afferent fibers were seen extending up to the epithelium that was void of hair cells, and intra- and extracellular biocytin labeling revealed afferent processes penetrating into the supporting cell layer of the crista. In 3/8 chicks 74 afferents could be characterized, and they significantly differed from controls (n = 130) by having a lower discharge rate and a negligible response to canal stimulation. In the intermediate period there was considerable variability in discharge properties of 121 afferents, but as a whole the number of "silent" fibers in the canal nerve diminished, the background rate increased, and a response to canal stimulation detected. Individually biocytin-labeled afferents had normal-appearing terminal specializations in the sensory epithelium by 28 days poststreptomycin. In the late period, afferents (n = 58) remained significantly different from controls in background discharge properties and response gain. The evidence suggests that a considerable amount of variability exists between chicks in the return of vestibular afferent function following ototoxic injury and that the secretory function of regenerating hair cells might become functional before their transducer function.

NASA Discipline Neuroscience↗

Micromotional studies of utricular and canal afferents

The long-range goal of this research was to refine our understanding of the sensitivity of the vestibular components of the ear to very-low-amplitude motion, especially, the role of gravity in this sensitivity. We focused on the American bullfrog--a common animal subject for vestibular sensory research. Our principal experimental method was to apply precise, sinusoidal microrotational stimuli to an anesthetized animal subject, to record the resulting responses in an individual vestibular nerve fiber from the intact ear, and to use intracellular dye to trace the fiber and thus identify the vestibular sensor that gave rise to it. In this way, we were able to identify specific micromotional sensitivities and to associate those sensitivities definitely with specific sensors. Furthermore, by recording from nerve fibers after they leave the intact inner-ear cavity, we were able to achieve these identifications without interrupting the delicate micromechanics of the inner ear. We were especially concerned with the relative roles of the utricle and the anterior semicircular canal in the sensing of microrotational motion of the head about horizontal axes, and with the role of gravity in mediating that sensing process in the utricle. The functional characterization of individual nerve fibers was accomplished with a conventional analytical tool, the cycle histogram, in which the nerve impulse rate was plotted against the phase of the sinusoidal stimulus.

Lewis, Edwin R.↗

Fluid flow stimulates rapid and continuous release of nitric oxide in osteoblasts

Interstitial fluid flow may mediate skeletal remodeling in response to mechanical loading. Because nitric oxide (NO) has been shown to be an osteoblast mitogen and inhibitor of osteoclastic resorption, we investigated and characterized the role of fluid shear on the release of NO in osteoblasts. Rat calvarial cells in a stationary culture produced undetectable levels of NO. Fluid shear stress (6 dyn/cm2) rapidly increased NO release rate to 9.8 nmol.h-1.mg protein-1 and sustained this production for 12 h of exposure to flow. Cytokine treatment also induced NO synthesis after a 12-h lag phase of zero production, followed by a production rate of 0.6 nmol.h-1.mg protein-1. Flow-induced NO production was blocked by the NO synthase (NOS) inhibitor NG-amino-L-arginine, but not by dexamethasone, which suggests that the flow stimulated a constitutive NOS isoform. This is the first time that a functional constitutively present NOS isoform has been identified in osteoblasts. Moreover, fluid flow represents the most potent stimulus of NO release in osteoblasts reported to date. Fluid flow-induced NO production may therefore play a primary role in bone maintenance and remodeling.

NASA Discipline Cell Biology↗

Translational Vestibulo-Ocular Reflex and Motion Perception During Interaural Linear Acceleration: Comparison of Different Motion Paradigms

The neural mechanisms to resolve ambiguous tilt-translation motion have been hypothesized to be different for motion perception and eye movements. Previous studies have demonstrated differences in ocular and perceptual responses using a variety of motion paradigms, including Off-Vertical Axis Rotation (OVAR), Variable Radius Centrifugation (VRC), translation along a linear track, and tilt about an Earth-horizontal axis. While the linear acceleration across these motion paradigms is presumably equivalent, there are important differences in semicircular canal cues. The purpose of this study was to compare translation motion perception and horizontal slow phase velocity to quantify consistencies, or lack thereof, across four different motion paradigms. Twelve healthy subjects were exposed to sinusoidal interaural linear acceleration between 0.01 and 0.6 Hz at 1.7 m/s/s (equivalent to 10 tilt) using OVAR, VRC, roll tilt, and lateral translation. During each trial, subjects verbally reported the amount of perceived peak-to-peak lateral translation and indicated the direction of motion with a joystick. Binocular eye movements were recorded using video-oculography. In general, the gain of translation perception (ratio of reported linear displacement to equivalent linear stimulus displacement) increased with stimulus frequency, while the phase did not significantly vary. However, translation perception was more pronounced during both VRC and lateral translation involving actual translation, whereas perceptions were less consistent and more variable during OVAR and roll tilt which did not involve actual translation. For each motion paradigm, horizontal eye movements were negligible at low frequencies and showed phase lead relative to the linear stimulus. At higher frequencies, the gain of the eye movements increased and became more inphase with the acceleration stimulus. While these results are consistent with the hypothesis that the neural computational strategies for motion perception and eye movements differ, they also indicate that the specific motion platform employed can have a significant effect on both the amplitude and phase of each.

Beaton, K. H.↗

Nerve-responsive troponin I slow promoter does not respond to unloading

We examined the regulation of the troponin I slow (TnIs) promoter during skeletal muscle unloading-induced protein isoform transition, by using a transgenic mouse line harboring the -4,200 to +12 base pairs region of the human TnIs promoter. Eighteen female transgenic mice ( approximately 30 g body mass) were randomly divided into two groups: weight-bearing (WB) controls (n = 9) and hindlimb unloaded (HU; n = 9). The HU mice were tail suspended for 7 days. Body mass was unchanged in the WB group but was reduced (-6%; P < 0.05) after the HU treatment. Absolute soleus muscle mass (-25%) and soleus mass relative to body mass (-16%) were both lower (P < 0.05) in the HU group compared with the WB mice. Northern blot analyses indicate that 7 days of HU result in a 64% decrease (P < 0.05) in the abundance of endogenous TnIs mRNA (microg/mg muscle) in the mouse soleus. Furthermore, there is a trend for the abundance of the fast troponin I mRNA to be increased (+34%). Analysis of transgenic chloramphenicol acetyltransferase activity in the soleus muscle revealed no difference (P > 0.05) between WB and HU groups. We conclude that additional elements are necessary for the TnIs gene to respond to an unloading-induced, slow-to-fast isoform transition stimulus.

Non-NASA Center↗

Development of a Ground Multi-Mission Low-Cost Optical Terminal (LCOT) for Free-Space Optical Communications

Once confined to the realm of laboratory experiments and theoretical papers, space-based laser communications (lasercomm) are on the verge of achieving mainstream status. Organizations from Facebook to NASA, and missions from cubesats to Orion are employing lasercomm to achieve gigabit communication speeds at mass and power requirements lower than that of traditional radio frequency (RF) methods. Since first demonstrating free-space optical communications services with Lunar Laser Communications Demonstration (LLCD) in 2013, NASA has invested in developing optical communications technologies and capabilities to enhancing its space communications networks. Along with evolving optical space terminals, NASA is also developing lasercomm grounds stations capable of meeting the rapidly increasing data volume demands of upcoming missions, from low-earth to lunar orbits and beyond and integrating these advanced capabilities into its Near-Space and Deep Space Networks. To meet this emerging need, the Low-Cost Optical Terminal (LCOT) project at NASA’s Goddard Space Flight Center (GSFC) is designing, building and validating a prototype for a flexible, multi-mission, and economical optical ground terminal that could be used as a blueprint for a global network of optical ground stations, capable of supporting a wide variety of missions. To date a major impediment to widespread adoption of laser communication has been the lack of an existing ground network infrastructure. A mission that wishes to take advantage of laser communication not only needs to invest in an optical space terminal, but it must also finance the creation of ground terminals to receive the downlink signal. This adds significant additional cost. Missions that do decide to incur the cost of financing a network of ground terminals end up building highly specialized optical receivers that are operable as receivers for that specific mission only. Significant Non-Recurring Engineering (NRE) cost is invested to build highly specialized one-of-a-kind ground terminals that go into storage after that particular mission is over. This is not an economical approach and does nothing to grow the number of optical ground stations available to future missions. In essence each mission that wants to take advantage of the benefits of lasercom has to start from scratch to provide a ground terminal network to support it. As long as this is the case, the cost for using laser communications will be too high for most missions to consider. LCOT intends to close this gap in technology by designing and developing a standard optical ground terminal design that is flexible enough to serve as a receiver for a wide range of future missions – a ground terminal that can be quickly reconfigured to receive downlinks at different wavelengths using different signal formats. Not only does LCOT have the industry-building objectives of utilizing commercial-off-the-shelf (COTS) components to the maximum extent possible, but also spurs the commercial development of other necessary lasercomm components not currently offered by industry. Finally, LCOT will give NASA scientists and engineers a facility where they can gain real-world experience with optical communications. It will give engineers a cost-effective way to try out new concepts and processes by providing the infrastructure for such testing. In this way it is hoped LCOT will serve as a stimulus for innovation in optical communications and speed its widespread adoption by future missions. The LCOT is comprised of five subsystems: Free-Space Optical, Transceiver, Amplifier, Monitor and Control, and Observatory Infrastructure. In August 2021, the LCOT team installed a 70 cm telescope, developed by Planewave Instruments that was optimized for optical communications. Free-Space Optical subsystem comprises of the telescope and its associated hardware, including a transmitter optical assembly, wide field cameras, two optical benches, and an adaptive optics subsystem. The transmit optical assembly, a unique concept design, is a cluster of four functionally independent transmit subassemblies located on the receive telescope. In addition to receiving optical signals and directing the expanded beam with high precision to the space terminal, it also performs tracking functions. The transmit optical assembly will support operations from Low Earth Orbit (LEO) through lunar and will be used as a template for industry manufacturing. The Optical Infrastructure subsystem is responsible for providing environmentally controlled shelters for LCOT equipment and various other systems. To maintain the safety and proper functionality of the telescope, a 16 ft Astrohaven clamshell dome procured which provides all-sky coverage without the need to rotate the dome. Additionally, Atmospheric Monitoring Assembly (AMA) will be part of optical infrastructure subsystem to ensure accurate performance of the LCOT. Like existing optical ground stations, LCOT will measure standard weather station parameters, infrared all sky image of cloud cover, and cloud height. LCOT, however, adds requirements for measuring night time seeing and, in the future, daytime seeing. Unlike other optical ground terminals, the LCOT is transceiver agnostic; user transceivers may be duplex transceivers, standalone receivers, or standalone transmitters with or without acquisition beacon functionality. As such, the LCOT project accommodates testing with external customer transceivers in a flexible manor, further complimenting its intended multi-mission goals. Another unique component of LCOT is the use of a new amplifier technology – the Very Large Mode Area (VLMA) amplifiers. This new technology allows LCOT to avoid the issues faced by previous laser communications ground terminals, gives users more flexibility and modular capability, and is capable of reaching an order of magnitude higher peak power than traditional High Power Optical Amplifiers (HPOA). One drawback of the VLMA HPOA approach is that the amplified light is output into free-space. The solution developed by LCOT is an optics train that couples the output of the VLMA amplifier into a short fiber for transport to the transmit telescopes with high efficiency. Like many of the LCOT components, a set of detailed manufacturing drawings have been created for the optics train to allow any machine shop with a multi-axis Computer Numerical Control (CNC) machine to fabricate the piece parts from commonly available materials. In line with the goals of LCOT, the monitor and control functions are developed as a modular and flexible system with the ability to support future hardware or algorithm changes, minimizing disruptions. A main priority of development in the Monitor and Control Subsystem (MCS) is the safety monitor system.

laser communication↗

Development of a Ground Multi-mission Low Cost Optical Terminal(LCOT) for Free-Space Optical Communication

Once confined to the realm of laboratory experiments and theoretical papers, space-based laser communications (lasercomm) are on the verge of achieving mainstream status. Organizations from Facebook to NASA, and missions from cubesats to Orion are employing lasercomm to achieve gigabit communication speeds at mass and power requirements lower than that of traditional radio frequency (RF) methods. Since first demonstrating free-space optical communications services with Lunar Laser Communications Demonstration (LLCD) in 2013, NASA has invested in developing optical communications technologies and capabilities to enhancing its space communications networks. Along with evolving optical space terminals, NASA is also developing lasercomm grounds stations capable of meeting the rapidly increasing data volume demands of upcoming missions, from low-earth to lunar orbits and beyond and integrating these advanced capabilities into its Near-Space and Deep Space Networks. To meet this emerging need, the Low-Cost Optical Terminal (LCOT) project at NASA’s Goddard Space Flight Center (GSFC) is designing, building and validating a prototype for a flexible, multi-mission, and economical optical ground terminal that could be used as a blueprint for a global network of optical ground stations, capable of supporting a wide variety of missions. To date a major impediment to widespread adoption of laser communication has been the lack of an existing ground network infrastructure. A mission that wishes to take advantage of laser communication not only needs to invest in an optical space terminal, but it must also finance the creation of ground terminals to receive the downlink signal. This adds significant additional cost. Missions that do decide to incur the cost of financing a network of ground terminals end up building highly specialized optical receivers that are operable as receivers for that specific mission only. Significant Non-Recurring Engineering (NRE) cost is invested to build highly specialized one-of-a-kind ground terminals that go into storage after that particular mission is over. This is not an economical approach and does nothing to grow the number of optical ground stations available to future missions. In essence each mission that wants to take advantage of the benefits of lasercom has to start from scratch to provide a ground terminal network to support it. As long as this is the case, the cost for using laser communications will be too high for most missions to consider. LCOT intends to close this gap in technology by designing and developing a standard optical ground terminal design that is flexible enough to serve as a receiver for a wide range of future missions – a ground terminal that can be quickly reconfigured to receive downlinks at different wavelengths using different signal formats. Not only does LCOT have the industry-building objectives of utilizing commercial-off-the-shelf (COTS) components to the maximum extent possible, but also spurs the commercial development of other necessary lasercomm components not currently offered by industry. Finally, LCOT will give NASA scientists and engineers a facility where they can gain real-world experience with optical communications. It will give engineers a cost-effective way to try out new concepts and processes by providing the infrastructure for such testing. In this way it is hoped LCOT will serve as a stimulus for innovation in optical communications and speed its widespread adoption by future missions. The LCOT is comprised of five subsystems: Free-Space Optical, Transceiver, Amplifier, Monitor and Control, and Observatory Infrastructure. In August 2021, the LCOT team installed a 70 cm telescope, developed by Planewave Instruments that was optimized for optical communications. Free-Space Optical subsystem comprises of the telescope and its associated hardware, including a transmitter optical assembly, wide field cameras, two optical benches, and an adaptive optics subsystem. The transmit optical assembly, a unique concept design, is a cluster of four functionally independent transmit subassemblies located on the receive telescope. In addition to receiving optical signals and directing the expanded beam with high precision to the space terminal, it also performs tracking functions. The transmit optical assembly will support operations from Low Earth Orbit (LEO) through lunar and will be used as a template for industry manufacturing. The Optical Infrastructure subsystem is responsible for providing environmentally controlled shelters for LCOT equipment and various other systems. To maintain the safety and proper functionality of the telescope, a 16 ft Astrohaven clamshell dome procured which provides all-sky coverage without the need to rotate the dome. Additionally, Atmospheric Monitoring Assembly (AMA) will be part of optical infrastructure subsystem to ensure accurate performance of the LCOT. Like existing optical ground stations, LCOT will measure standard weather station parameters, infrared all sky image of cloud cover, and cloud height. LCOT, however, adds requirements for measuring night time seeing and, in the future, daytime seeing. Unlike other optical ground terminals, the LCOT is transceiver agnostic; user transceivers may be duplex transceivers, standalone receivers, or standalone transmitters with or without acquisition beacon functionality. As such, the LCOT project accommodates testing with external customer transceivers in a flexible manor, further complimenting its intended multi-mission goals. Another unique component of LCOT is the use of a new amplifier technology – the Very Large Mode Area (VLMA) amplifiers. This new technology allows LCOT to avoid the issues faced by previous laser communications ground terminals, gives users more flexibility and modular capability, and is capable of reaching an order of magnitude higher peak power than traditional High Power Optical Amplifiers (HPOA). One drawback of the VLMA HPOA approach is that the amplified light is output into free-space. The solution developed by LCOT is an optics train that couples the output of the VLMA amplifier into a short fiber for transport to the transmit telescopes with high efficiency. Like many of the LCOT components, a set of detailed manufacturing drawings have been created for the optics train to allow any machine shop with a multi-axis Computer Numerical Control (CNC) machine to fabricate the piece parts from commonly available materials. In line with the goals of LCOT, the monitor and control functions are developed as a modular and flexible system with the ability to support future hardware or algorithm changes, minimizing disruptions. A main priority of development in the Monitor and Control Subsystem (MCS) is the safety monitor system.

Haleh Safavi↗