Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectral control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Along-Trajectory Acoustic Signal Variations Observed During the Hypersonic Re-Entry of the OSIRIS-REx Sample Return Capsule

The re-entry of the Origins, Spectral Interpretation, Resource Identification, and Security-Regolith Explorer (OSIRIS-REx) sample return capsule (SRC) on 24 September 2023 presented a rare opportunity to study atmospheric entry dynamics through a dense network of ground-based infrasound sensors. As the first interplanetary capsule to re-enter over the United States since Stardust in 2006, this event allowed for unprecedented observations of infrasound signals generated during hypersonic descent. We deployed 39 single-sensor stations across Nevada and Utah, strategically distributed to capture signals from distinct trajectory points. Infrasound data were analyzed to examine how signal amplitude and period vary with altitude and propagation path for a nonablating hypersonic object with well-defined physical and aerodynamic properties. Raytracing simulations incorporated atmospheric specifications from the ground-2-space model to estimate source altitudes for observed signals. Results confirmed ballistic arrivals at all stations, with source altitudes ranging from 44 to 62 km along the trajectory. Signal period and amplitude exhibited strong dependence on source altitude, with higher altitudes corresponding to lower amplitudes, longer periods, and reduced high-frequency content. Regression analysis demonstrated strong correlations between signal characteristics and both altitude and propagation geometry. Our results suggest, when attenuation is considered, the amplitude is primarily determined by the source, with the propagation path playing a secondary role over the distances examined. These findings emphasize the utility of controlled SRC re-entries for advancing our understanding of natural meteoroid dynamics, refining atmospheric entry models, and improving methodologies for planetary defense. The OSIRIS-REx SRC campaign represents the most comprehensive infrasound study of a hypersonic re-entry to date, showcasing the potential of coordinated geophysical observational networks for high-energy atmospheric phenomena, including space debris re-entries.

58 GEOSCIENCES↗

Monitoring SEIRAS on a Graphitic Electrode for Surface-Sensitive Electrochemistry: Real-Time Electrografting

The ubiquity of graphitic materials in electrochemistry makes it highly desirable to probe their interfacial behavior under electrochemical control. Probing the dynamics of molecules at the electrode/electrolyte interface is possible through spectroelectrochemical approaches involving surface-enhanced infrared absorption spectroscopy (SEIRAS). Usually, this technique can only be done on plasmonic metals such as gold or carbon nanoribbons, but a more convenient substrate for carbon electrochemical studies is needed. Here, we expanded the scope of SEIRAS by introducing a robust hybrid graphene-on-gold substrate, where we monitored electrografting processes occurring at the graphene/electrolyte interface. These electrodes consist of graphene deposited onto a roughened gold-sputtered internal reflection element (IRE) for attenuated total reflectance (ATR) SEIRAS. The capabilities of the graphene-gold IRE were demonstrated by successfully monitoring the electrografting of 4-amino-2,2,6,6-tetramethyl-1-piperidine N -oxyl (4-amino-TEMPO) and 4-nitrobenzene diazonium (4-NBD) in real time. These grafts were characterized using cyclic voltammetry and ATR-SEIRAS, clearly showing the 1520 and 1350 cm –1 NO 2 stretches for 4-NBD and the 1240 cm –1 C–C, C–C–H, and N–Ȯ stretch for 4-amino-TEMPO. Successful grafts on graphene did not show the SEIRAS effect, while grafting on gold was not stable for TEMPO and had poorer resolution than on graphene-gold for 4-NBD, highlighting the uniqueness of our approach. The graphene-gold IRE is proficient at resolving the spectral responses of redox transformations, unambiguously demonstrating the real-time detection of surface processes on a graphitic electrode. This work provides ample future directions for real-time spectroelectrochemical investigations of carbon electrodes used for sensing, energy storage, electrocatalysis, and environmental applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗

Cosmic rays in molecular clouds probed by H 2 rovibrational lines

Context. Low-energy cosmic rays (<1 TeV) play a fundamental role in the chemical and dynamical evolution of molecular clouds, as they control the ionisation, dissociation, and excitation of H 2 . Their characterisation is therefore important both for the interpretation of observations and for the development of theoretical models. However, the methods used so far for estimating the cosmic-ray ionisation rate in molecular clouds have several limitations due to uncertainties in the adopted chemical networks. Aims. Here, we refine and extend a previously proposed method to estimate the cosmic-ray ionisation rate in molecular clouds by observing rovibrational transitions of H 2 at near-infrared wavelengths, which are mainly excited by secondary cosmic-ray electrons. Methods. Combining models of interstellar cosmic-ray propagation and attenuation in molecular clouds with the rigorous calculation of the expected secondary electron spectrum and updated electron-H 2 excitation cross sections, we derive the intensity of the four H 2 rovibrational transitions observable in cold dense gas: (1—0)O(2), (1—0)Q(2), (1—0)S(0), and (1—0)O(4). Results. The proposed method allows the estimation of the cosmic-ray ionisation rate for a given observed line intensity and H 2 column density. We are also able to deduce the shape of the low-energy cosmic-ray proton spectrum impinging upon the molecular cloud. In addition, we present a look-up plot and a web-based application that can be used to constrain the low-energy spectral slope of the interstellar cosmic-ray proton spectrum. We finally comment on the capability of the James Webb Space Telescope to detect these near-infrared H 2 lines, which will make it possible to derive, for the first time, spatial variation in the cosmic-ray ionisation rate in dense gas. Besides the implications for the interpretation of the chemical-dynamic evolution of a molecular cloud, it will finally be possible to test competing models of cosmic-ray propagation and attenuation in the interstellar medium, as well as compare cosmic-ray spectra in different Galactic regions

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of a Space Capsule Entering Earth’s Atmosphere with Distributed Acoustic Sensing (DAS)

On 24 September 2023, the Origins, Spectral Interpretation, Resource Identification, and Security-Regolith Explorer sample return capsule (SRC) entered Earth’s atmosphere after successfully collecting samples from an asteroid. The known trajectory and timing of this return provided a rare opportunity to strategically instrument sites to record geophysical signals produced by the capsule because it travelled at hypersonic speeds through the atmosphere. For this work, we deployed two distributed acoustic sensing (DAS) interrogators to sample over 12 km of surface-draped fiber-optic cables, as well as six collocated seismometer-infrasound sensor pairs, spread across two sites near Eureka, Nevada. This campaign-style rapid deployment is the first reported recording of an SRC re-entry with any distributed fiber-optic sensing technology. The DAS interrogators recorded an impulsive arrival with an extended coda which had features that were similar to recordings from both the seismometers and infrasound sensors. While the signal-to-noise ratio of the DAS data was lower than the seismic-infrasound data, the extremely dense spacing of fiber-optic sensors allowed for more phases to be clearly distinguished and the visualization of the continuous transformation of the wavefront as it impacted the ground. Unexpectedly, the DAS recordings contain less low-frequency content than is present in both the seismic and infrasound data. The deployment conditions strongly affected the recorded DAS data; in particular, we observed that fiber selection and placement exert strong controls on data quality.

58 GEOSCIENCES↗

Uranium measurements in the field using high-resolution cadmium zinc telluride detectors

A new generation of cadmium zinc telluride (CZT) detectors has become available and is being evaluated by the International Atomic Energy Agency (IAEA) for safeguards verifications in the field. The new CZT detector, model M400, is a room temperature spectrometer manufactured by H3D, Inc. The M400 demonstrates superior energy resolution, effective isotope identification capabilities, and convenient usability features when tested in a controlled laboratory environment. These characteristics define the M400 as a potential platform for IAEA field detection applications, which could become suitable for nuclear material characterization (e.g., enrichment verification) and nuclear safeguards missions. The capabilities of gamma spectrometry codes including Fixed energy, Response function Analysis with Multiple efficiencies (FRAM) from Los Alamos National Laboratory, CZT for Uranium (CZTU) from Lawrence Livermore National Laboratory, and Gamma Detector Response and Analysis Software (GADRAS) from Sandia National Laboratories were adapted for M400 spectra, and the performance of the codes has been validated. This was reported in a prior work. To further validate the performance of the high-energy resolution CZT detector and the isotopic analysis codes, a field measurement campaign consisting of uranium hexafluoride (UF 6 ) cylinder measurements was conducted at a fuel fabrication facility. A total of 34 Type 30B cylinders containing UF6 were measured using three different M400 CZT detectors. Each detector was outfitted with a custom rectangular collimator and shield made out T-Flex®, a tungsten-impregnated polymer. Measurements were performed at three different locations of the cylinder, ensuring that the measurement geometry satisfied the infinite thickness criterion. The spectra from the M400 CZT were analyzed using the code General Enrichment Meter (GEM). For analyzing the gamma-ray spectra from UF 6 cylinder, the GEM code is the appropriate tool since it relies only on the gamma-ray emissions from 235 U and not from other isotopes. Results from the spectral analysis were compared with the known abundance of 235 U in the cylinders, as well as with the International Target Values 2020 (ITV2020). The suitability of the different underlying techniques used by the various codes for UF 6 analysis is discussed. The challenges of measuring UF 6 contained in cylinders and mitigation strategies are highlighted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Requirements on the gain calibration for LiteBIRD polarisation data with blind component separation

The detection of primordial B modes of the cosmic microwave background (CMB) could provide information about the early stages of the Universe's evolution. The faintness of this signal requires exquisite calibration accuracy and control of instrumental systematic effects which otherwise could bias the measurements. In this work, we study the impact of an imperfect relative polarisation gain calibration on the recovered value of the tensor-to-scalar ratio r for the LiteBIRD experiment, through the application of the blind Needlet Internal Linear Combination (NILC) foreground-cleaning method. We derive requirements on the relative calibration accuracy of the overall polarisation gain (Δg ν ) for each LiteBIRD frequency channel. Our results show that minimum variance techniques, as NILC, are less sensitive to systematic gain calibration uncertainties compared to a parametric approach, if the latter is not equipped with a proper modelling of these instrumental effects. In this study, the most stringent requirements are found in the channels where the CMB signal is relatively brighter, with the tightest constraints at 166 GHz (Δg ν ≈ 0.16%). This differs from the outcome of an analogous analysis performed with a parametric method, where the tightest requirements are obtained for the foreground-dominated channels. Gain calibration uncertainties, corresponding to the derived requirements, are then simultaneously propagated into all frequency channels. By doing so, we find that the overall impact on estimated r is lower than the total gain systematic budget for LiteBIRD approximately by a factor 5, due to the correlations of the impacts of gain calibration uncertainties in different frequency channels. In order to decouple the systematic effect from the specific choice of the model, we derive the requirements assuming constant spectral parameters for the foreground emission. To assess the robustness of the obtained results against more realistic scenarios, we repeat the analysis assuming sky models of intermediate and high complexity. In these further cases, we adopt an optimised NILC pipeline, called the Multi-Clustering NILC (MC-NILC). We find that the impact of gain calibration uncertainties on r is lower than the LiteBIRD gain systematics budget for the intermediate-complexity sky model. For the high-complexity case, instead, it would be necessary to tighten the requirements by a factor 1.8.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of natural gamma background radiation on portal monitor radioisotope unmixing

It is well known that national security relies on several layers of protection. One of the most important is the traffic control at borders and ports that exploits Radiation Portal Monitors (RPMs) to detect and deter potential smuggling attempts. Most portal monitors rely on plastic scintillators to detect gamma rays. Despite their poor energy resolution, their cost effectiveness and the possibility of growing them in large sizes make them the gamma-ray detector of choice in RPMs. Unmixing algorithms applied to organic scintillator spectra can be used to reliably identify the bare and unshielded radionuclides that triggered an alarm, even with fewer than 1000 detected counts and in the presence of two or three nuclides at the same time. In this work, we experimentally studied the robustness of a state-of-the-art unmixing algorithm to different radiation background spectra, due to varying atmospheric conditions, in the 16 °C to 28 °C temperature range. In the presence of background, the algorithm is able to identify the nuclides present in unknown radionuclide mixtures of three nuclides, when at least 1000 counts from the sources are detected. With fewer counts available, we found larger differences of approximately 35.9% between estimated nuclide fractions and actual ones. In these low count rate regimes, the uncertainty associated by our algorithm with the identified fractions could be an additional valuable tool to determine whether the identification is reliable or a longer measurement to increase the signal-to-noise ratio is needed. Moreover, the algorithm identification performances are consistent throughout different data sets, with negligible differences in the presence of background types of different intensity and spectral shape.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Counterdiabatic Driving with Performance Guarantees

Counterdiabatic (CD) driving has the potential to speed up adiabatic quantum state preparation by suppressing unwanted excitations. However, existing approaches either require intractable classical computations or are based on approximations that do not have performance guarantees. We propose and analyze a nonvariational, system-agnostic CD expansion method and analytically show that it converges exponentially quickly in the expansion order. In finite systems, the required resources scale inversely with the spectral gap, which we argue is asymptotically optimal. To extend our method to the thermodynamic limit and suppress errors stemming from high-frequency transitions, we leverage finite-time adiabatic protocols. In particular, we show that a time determined by the quantum speed limit is sufficient to prepare the desired ground state, without the need to optimize the adiabatic trajectory. Numerical tests of our method on the quantum Ising chain show that our method can outperform state-of-the-art variational CD approaches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HSQC spectra of lignin isolated from poplar roots

Here we present a curated dataset of two-dimensional heteronuclear single quantum coherence (HSQC) nuclear magnetic resonance (NMR) spectra of lignin isolated from roots of a greenhouse grown natural population of an energy crop poplar (Populus trichocarpa). Dormant cuttings of field-grown poplar were grown in 6-liter pots in a peat-based media containing bark, perlite, vermiculite, dolomite lime and a wetting agent in an environmentally controlled greenhouse. Temperatures were between 21 and 23 °C, with supplemental lighting to support a 16-h day length using 1000-watt high-pressure sodium lights in greenhouse. Once established, all plants were cut-back, allowed to regrow and harvested at the same time following an eight-month long growth period. Plants were harvested and the belowground roots were washed off soils, blotted, dried in an oven at 70 °C for 3 days, and Wiley milled (mesh size 20). The roots were Soxhlet-extracted with toluene/ethanol for 24 h to remove extractives. The extracted roots were ball-milled in a Retsch PM100 planetary ball mill using a porcelain jar with ceramic balls at 600 rpm for 2 h (in 5 min on and 5 min off cycles to avoid excessive sample heating). The ball-milled materials were then subjected to enzymatic hydrolysis for 48 h followed by centrifugation and washing with deionized water. The solid residue was extracted twice with 96% (v/v) 1,4-dioxane/water mixture at room temperature overnight. The extracts were combined, rotary evaporated, and freeze-dried to recover lignin. The dry lignin samples were dissolved in deuterated dimethyl sulfoxide (d6) and transferred into a 5 mm tube. 13C–1H HSQC experiments were performed in a Bruker Avance III HD 500 MHz NMR spectrometer operating at a frequency of 125.12 MHz for the 13C nucleus using a standard Bruker pulse sequence on a Prodigy platform cryoprobe. The NMR spectra were acquired under the following acquisition conditions: 220 ppm spectral width in F1 (13C) dimension with 256 data points and 12 ppm spectral width in F2 (1H) dimension with 1024 data points, a 90° pulse, a one bond C–H coupling constant of 145 Hz, a 1.0 s pulse delay, and 64 scans. Spectra were processed using the Bruker TopSpin software. Additional meta data is embedded in the raw spectra figures.

HSQC, lignin, poplar, roots, CBI↗

Improved precision in As speciation analysis with HERFD-XANES at the As K -edge: the case of As speciation in mine waste

High-energy-resolution fluorescence-detected (HERFD) X-ray absorption near-edge spectroscopy (XANES) is a spectroscopic method that allows for increased spectral feature resolution, and greater selectivity to decrease complex matrix effects compared with conventional XANES. XANES is an ideal tool for speciation of elements in solid-phase environmental samples. Accurate speciation of As in mine waste materials is important for understanding the mobility and toxicity of As in near-surface environments. In this study, linear combination fitting (LCF) was performed on synthetic spectra generated from mixtures of eight measured reference compounds for both HERFD-XANES and transmission-detected XANES to evaluate the improvement in quantitative speciation with HERFD-XANES spectra. The reference compounds arsenolite (As 2 O 3 ), orpiment (As 2 S 3 ), getchellite (AsSbS 3 ), arsenopyrite (FeAsS), kaňkite (FeAsO 4 ·3.5H 2 O), scorodite (FeAsO 4 ·2H 2 O), sodium arsenate (Na 3 AsO 4 ), and realgar (As 4 S 4 ) were selected for their importance in mine waste systems. Statistical methods of principal component analysis and target transformation were employed to determine whether HERFD improves identification of the components in a dataset of mixtures of reference compounds. LCF was performed on HERFD- and total fluorescence yield (TFY)-XANES spectra collected from mine waste samples. Arsenopyrite, arsenolite, orpiment, and sodium arsenate were more accurately identified in the synthetic HERFD-XANES spectra compared with the transmission-XANES spectra. In mine waste samples containing arsenopyrite and either scorodite or kaňkite, LCF with HERFD-XANES measurements resulted in fits with smaller R -factors than concurrently collected TFY measurements. The improved accuracy of HERFD-XANES analysis may provide enhanced delineation of As phases controlling biogeochemical reactions in mine wastes, contaminated soils, and remediation systems.

58 GEOSCIENCES↗

An Unmanned Aerial System (UAS) for concurrent measurements of solar-induced chlorophyll fluorescence and hyperspectral reflectance toward improving crop monitoring

Unmanned aerial system (UAS)-based remote sensing can provide high spatial- and temporal-resolution crop monitoring for precision management. Existing crop monitoring UAS primarily use conventional techniques such as multi-spectral broadband vegetation indices (VIs) to track canopy structure/biomass. Recently developed lightweight hyperspectral sensors can track crop physiology and performance via complementary signals such as solar-induced chlorophyll fluorescence (SIF) and photochemical reflectance index (PRI) that can be derived from hyperspectral reflectance. However, few existing UAS can acquire high-quality SIF and hyperspectral reflectance. Here, we designed a novel UAS that simultaneously captures far-red SIF and hyperspectral reflectance, using a single bifurcated fiber and motorized arm to measure downwelling and upwelling irradiance. The UAS was tested over (1) a heterogeneous corn field with spatially varying crop yield potential and (2) a set of soybean and corn plots under differing nutrient treatments. Our UAS can maintain stability under low-to-moderate winds (2–3 m/s) with <0.4 m geolocation accuracy, <0.1 m altitude drift, and <1.5° error of the fiber optic from nadir position during scanning. Weekly seasonal campaigns reveal that SIF outperforms conventional VIs such as the normalized difference vegetation index (NDVI) for distinguishing plots with different crop yield potential, especially after canopy closure when NDVI tends to saturate. The UAS can capture the diurnal dynamics of SIF and PRI for both corn and soybean. At the seasonal scale, SIF acquired from the UAS correlates well with that from a fixed SIF tower system ( R 2 = 0.81), which measured the same target albeit with different footprints, demonstrating the capability of UAS in characterizing the seasonal progression of crop activity. In conclusion, our newly developed UAS provides high-quality SIF and hyperspectral reflectance, facilitating mechanistic understanding of the physiological control on photosynthesis dynamics. Our findings also imply that this UAS could enable extension of fixed tower-based systems to monitor multiple targets from diurnal to seasonal scales and improve monitoring of heterogeneous fields.

59 BASIC BIOLOGICAL SCIENCES↗

Integration of fixed-frequency and FM-CW (frequency-modulated continuous-wave) reflectometers for coincident turbulence measurements on LTX- β (Lithium Tokamak eXperiment- β )

The fixed-frequency and frequency-modulated continuous-wave (FM-CW) reflectometers on LTX-β (Lithium Tokamak eXperiment-β) have been configured to use the same transmission lines and antenna arrays for coincident views of the core and edge plasma. The fixed-frequency channels (13.1–20.5 and 20–40 GHz, tunable between discharges) provide time-resolved measurements of density fluctuations, while the FM-CW channels (13.1–20.2 and 19.5–33.5 GHz) measure the density profile and fluctuations, with high spatial resolution and a sampling rate determined by the frequency sweep interval (5 μs). Data from both reflectometers are synchronously acquired to simultaneously leverage the wide bandwidth and high spatial resolution of the respective systems. Experiments showed that mutual crosstalk interference is momentary and does not diminish the capability of either system. Spectral analysis indicated broad power spectra (several hundreds of kHz) and suggests that the signals from the FM-CW system are consistent with under-sampled fixed-frequency signals. Radial correlations were explored using data from the two reflectometers, as well as from the FM-CW system alone. The core channels showed high levels of agreement between these two comparisons, suggesting that the data from the reflectometers are interchangeable for statistical estimates. For the edge channels, comparisons using data from the FM-CW reflectometer alone showed significant decorrelation due to time lag caused by the finite frequency up-sweep duration. Alternatively, this effect is eliminated when cross-correlating data from the different reflectometers. Finally, these results highlight the advantages of operating the fixed-frequency and FM-CW reflectometers in this manner, where the combined system can overcome the limitations of each separate system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A UNIONS view of the brightest central galaxies of candidate fossil groups

The formation process of fossil groups (FGs) is still under debate, and, because of their relative rarity, large samples of such objects are still missing. The aim of the present paper is to increase the sample of known FGs, to analyse the properties of their brightest group galaxies (BGGs), and to compare them with a control sample of non-FG BGGs. We extracted a sample of 87 FG and 100 non-FG candidates from a large spectroscopic catalogue of haloes and galaxies. For all the objects with data available in UNIONS (initially the Canada France Imaging Survey, CFIS) in the u and r bands, and/or in an extra r-band processed to preserve all low-surface-brightness features (rLSB), we performed a 2D photometric fit of the BGG with GALFIT with one or two Sérsic components. We also analysed how the subtraction of the intracluster light (ICL) contribution modifies the BGG properties. From the SDSS spectra available for the BGGs of 65 FGs and 82 non-FGs, we extracted the properties of their stellar populations with Firefly. To complement our study, and in order to provide a detailed illustration of the possible origin of emission lines in the FG BGGs, involving the presence or absence of an AGN, we investigated the origin of the emission lines in a nearby FG that is dominated by the NGC 4104 galaxy. Morphologically, a single Sérsic profile can fit most objects in the u band, while two Sérsics are needed in the r and rLSB bands, both for FGs and non-FGs. Non-FG BGGs cover a larger range of Sérsic index n. FG BGGs follow the Kormendy relation (mean surface brightness versus effective radius) previously derived for almost 1000 brightest cluster galaxies (BCGs), while the majority of non-FGs BGGs are located below this relation, with fainter mean surface brightnesses. This suggests that FG BGGs have evolved similarly to BCGs, and non-FG BGGs have evolved differently from both FG BGGs and BCGs. All the above properties can be strongly modified by the subtraction of the ICL contribution. Based on spectral fitting, the stellar populations of FG and non-FG BGGs do not differ significantly. FG and non-FG BGGs differ from one another in terms of their morphological properties and Kormendy relation, suggesting they have had different formation histories. However, it is not possible to trace differences in their stellar populations or in their large-scale distributions.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of Cycle-to-Cycle Variations in Internal Combustion Engine Using Proper Orthogonal Decomposition

The understanding, modeling and control of the cycle-to-cycle variation (CCV) in the modern internal combustion engine (ICE) is a key scientific challenge to achieve stable engine operation. High CCV in the engine combustion chamber may contribute to partial burn, misfire and knock, which adversely affects the engine performance and may potentially damage the engine. The objective of the current study is to leverage high-fidelity numerical simulations to improve the understanding of the causes of CCV. Using the massively parallel code, Nek5000, multi-cycle, wall-resolved large-eddy simulations (LES) were performed for the General Motors (GM), Transparent Combustion Chamber (TCC-III) optical engine under motored operating conditions. Further, the large-scale structures of the in-cylinder flow were investigated using a triple proper orthogonal decomposition (POD) technique to explore the characteristics of different parts of the flow and their contributions to CCV. The kinetic energy of the subset of flow structures were determined and correlated between the intake and compression strokes. The insights from the analysis of the large-scale flow structures will be used to assist the development of improved engine designs with reduced CCV and enhance the engine performance.

33 ADVANCED PROPULSION SYSTEMS↗

Scale-dependent spatial variabilities of hydrological exchange flows and transit time in a large regulated river

Hydrological exchange flows (HEF) across the river-aquifer interface and the associated residence time of river water in the aquifer have important implications for contaminant plume migration and biogeochemical processes in the river corridor. HEFs and residence time are influenced by both subsurface physical features and hydrologic forcing related to the transport process, which can exhibit complex spatial and temporal variations. In this study, we used a massively parallel subsurface flow model and a particle-tracking model to study the influences of different control factors on spatial variability of HEFs and residence time distributions (RTD) in the Hanford Reach of the Columbia River in Washington State. A total number of 100M particles were randomly injected in time and space and then tracked in a model domain that covers a 51-km 2 area (15.1M model cells). We used hourly river stages and groundwater levels to drive the model to provide dynamic velocity fields for the particle tracking in the simulation period that was longer than 2 years. The groundwater flow simulation and particle-tracking results provide the first comprehensive assessment of the spatial distribution of HEFs and residence time in large complex river corridors. Overall, our results show that the aquifer hydrogeological structure has the strongest correlation with the extent and magnitude of exchange flux. The residence time exhibits complex patterns that are impacted by all the river geomorphologic, hydrodynamic, and hydrogeologic factors and are strongly correlated with the downwelling ratio of exchange flux. The new insights gained through this study can be used to support the development of reduced-order models of HEFs and RTDs for large complex river systems.

54 ENVIRONMENTAL SCIENCES↗

High-Power Clock Laser Spectrally Tailored for High-Fidelity Quantum State Engineering

Highly frequency-stable lasers are ubiquitous tools for optical-frequency metrology, precision interferometry, and quantum information science. While making a universally applicable laser is unrealistic, spectral noise can be tailored for specific applications. Here we report a high-power 698-nm clock laser with a maximum output of 4W and minimized frequency noise up to a few kHz Fourier frequency, together with long-term instability of 3.5 × 10 −17 at one to thousands of seconds. The laser-frequency noise is precisely characterized with atom-based spectral analysis that employs a pulse sequence designed to suppress sensitivity to intensity noise. This method provides universally applicable tunability of the spectral response and analysis of quantum sensors over a wide frequency range. With the optimized laser system characterized by this technique, we achieve an average single-qubit Clifford gate fidelity of up to 𝐹$^2_1$ = 0.999⁢64⁢(3) when simultaneously driving 3000 optical qubits with a homogeneous Rabi frequency ranging from 10 Hz to 1 kHz. This result represents the highest single optical-qubit-gate fidelity for a large number of atoms.

atomic gases↗