Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sim”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Beyond universal behavior in the one-dimensional chain with random nearest-neighbor hopping

Here, we study the one-dimensional nearest-neighbor tight-binding model of electrons with independently distributed random hopping and no on-site potential (i.e., off-diagonal disorder with particle-hole symmetry, leading to sublattice symmetry, for each realization). For nonsingular distributions of the hopping, it is known that the model exhibits a universal, singular behavior of the density of states $ρ(E) ~ 1/|E\: \text{ln}^3 |E||$ and of the localization length $ξ(E) ~ |\text{ln}|E||$, near the band center $\textit{E}$ = 0 . (This singular behavior is also applicable to random $\textit{XY}$ and Heisenberg spin chains; it was first obtained by Dyson for a specific random harmonic oscillator chain.) Simultaneously, the state at$\textit{E}$ = 0 shows a universal, subexponential decay at large distances $\sim \text{exp}[–\sqrt{r/r_0}]$. In this study, we consider singular, but normalizable, distributions of hopping, whose behavior at small $\textit{t}$ is of the form $\sim 1/[t \text{ln}^{λ+1}(1/t)]$, characterized by a single, continuously tunable parameter λ > 0. We find, using a combination of analytic and numerical methods, that while the universal result applies for λ > 2, it no longer holds in the interval 0 < λ < 2. In particular, we find that the form of the density of states singularity is enhanced (relative to the Dyson result) in a continuous manner depending on the nonuniversal parameter λ; simultaneously, the localization length shows a less divergent form at low energies and ceases to diverge below λ = 1. For λ < 2, the fall-off of the $\textit{E}$ = 0 state at large distances also deviates from the universal result and is of the form $\sim\text{exp}[–(r/r_0)^{1/λ}]$ , which decays faster than an exponential for λ < 1.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum oscillations in a bilayer with broken mirror symmetry: A minimal model for YBa 2 Cu 3 O 6 + δ

Using an exact numerical solution and semiclassical analysis, we investigate quantum oscillations (QOs) in a model of a bilayer system with an anisotropic (elliptical) electron pocket in each plane. Key features of QO experiments in the high temperature superconducting cuprate YBCO can be reproduced by such a model, in particular the pattern of oscillation frequencies (which reflect “magnetic breakdown” between the two pockets) and the polar and azimuthal angular dependence of the oscillation amplitudes. However, the requisite magnetic breakdown is possible only under the assumption that the horizontal mirror plane symmetry is spontaneously broken and that the bilayer tunneling t ⊥ is substantially renormalized from its ‘bare’ value. Lastly, under the assumption that t ⊥ = $\sim\atop{Z}_t$ $(0)\atop{⊥}$, where $\sim\atop{Z}$ is a measure of the quasiparticle weight, this suggests that $\sim\atop{Z}$ ≲ 1/20. Detailed comparisons with new YBa 2 Cu 3 O 6.58 QO data, taken over a very broad range of magnetic field, confirm specific predictions made by the breakdown scenario.

36 MATERIALS SCIENCE↗

Nuclear magnetic resonance investigation of the heavy fermion system Ce 2 CoAl 7 Ge 4

We present here nuclear magnetic resonance (NMR) and nuclear quadrupole resonance (NQR) measurements performed on single crystalline ${\mathrm{Ce}}_{2}{\mathrm{CoAl}}_{7}{\mathrm{Ge}}_{4}$, a member of a recently discovered family of heavy fermion materials ${\mathrm{Ce}}_{2}M{\mathrm{Al}}_{7}{\mathrm{Ge}}_{4}$ ($M=\mathrm{Co}$, Ir, Ni, or Pd). Previous measurements indicated a strong Kondo interaction as well as magnetic order below ${T}_{M}=1.8\mathrm{K}$. Our NMR spectral measurements show that the Knight shift $K$ is proportional to the bulk magnetic susceptibility ${\chi}$ at high temperatures. A clear Knight shift anomaly ($K\neg{}{\propto}{\chi}$) is observed at coherence temperatures ${T}^{*}{\sim}17.5\mathrm{K}$ for ${H}_{0}{\parallel}\stackrel{\hat{}{}{}}{c}$ and 10 K for ${H}_{0}{\parallel}\stackrel{\hat{}{}{}}{a}$ at the $^{59}\mathrm{Co}$ site, and ${T}^{*}{\sim}12.5\mathrm{K}$ at the $^{27}\mathrm{Al}$(3) site for ${H}_{0}{\parallel}\stackrel{\hat{}{}{}}{a}$ characteristic of the heavy fermion nature of this compound. At high temperatures, the $^{59}\mathrm{Co}$ NMR spin-lattice relaxation rate ${T}_{1}^{{-}1}$ is dominated by spin fluctuations of the $4f$ local moments with a weak metallic background. The spin fluctuations probed by $^{59}\mathrm{Co}$ NMR are anisotropic and larger in the basal plane than in the $c$ direction. Furthermore, we find ${({T}_{1}TK)}^{{-}1}{\propto}{T}^{{-}1/2}$ at the $^{59}\mathrm{Co}$ site as expected for a Kondo system for $T>{T}^{*}$ and $T>{T}_{K}$. $^{59}\mathrm{Co}$ NQR ${T}_{1}^{{-}1}$ measurements at low temperatures indicate slowing down of spin fluctuations above the magnetic ordering temperature ${T}_{M}{\sim}1.8\mathrm{K}$. A weak ferromagnetic character of fluctuations around $\mathbf{q}=0$ is evidenced by an increase of ${\chi}T$ versus $T$ above the magnetic ordering temperature. We also find good agreement between the observed and calculated electric field gradients at all observed sites.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Memory-triggered supernova neutrino detection

Here, we demonstrate that observations of the gravitational memory from core collapse supernovae at future deci-Hz interferometers enable time-triggered searches of supernova neutrinos at Mt-scale detectors. Achieving a sensitivity to characteristic strains of at least $\sim 10^{–25}$ at $f ≃ 0.3$ $\mathrm{Hz}$ —e.g., by improving the noise of DECIGO by one order of magnitude—will allow robust time triggers for supernovae at distances $D \sim 40–300$ $\mathrm{Mpc}$, resulting in a nearly background-free sample of $\sim 3–70$ neutrino events per Mt per decade of operation. This sample would bridge the sensitivity gap between rare galactic supernova bursts and the cosmological diffuse supernova neutrino background, allowing detailed studies of the neutrino emission of supernovae in the local Universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark Forces and Light Dark Matter

We consider a simple class of models in which the dark matter, X, is coupled to a new gauge boson, phi, with a relatively low mass (m_phi \sim 100 MeV-3 GeV). Neither the dark matter nor the new gauge boson have tree-level couplings to the Standard Model. The dark matter in this model annihilates to phi pairs, and for a coupling of g_X \sim 0.06 (m_X/10 GeV)^1/2 yields a thermal relic abundance consistent with the cosmological density of dark matter. The phi's produced in such annihilations decay through a small degree of kinetic mixing with the photon to combinations of Standard Model leptons and mesons. For dark matter with a mass of \sim10 GeV, the shape of the resulting gamma-ray spectrum provides a good fit to that observed from the Galactic Center, and can also provide the very hard electron spectrum required to account for the observed synchrotron emission from the Milky Way's radio filaments. For kinetic mixing near the level naively expected from loop-suppressed operators (epsilon \sim 10^{-4}), the dark matter is predicted to scatter elastically with protons with a cross section consistent with that required to accommodate the signals reported by DAMA/LIBRA, CoGeNT and CRESST-II.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Signature of the Fragmentation of a Color Flux Tube

The production of quark-antiquark pairs along a color flux tube precedes the fragmentation of the tube. Because of the local conservation of momentum and charge, the production of a $q$-$\bar q$ pair will lead to correlations of adjacently produced mesons (mostly pions). Adjacently produced pions however can be signalled by the their rapidity difference $\Delta y$ falling within the window of $|\Delta y | < 1/(dN_\pi/dy)$, on account of the space-time-rapidity ordering of produced pions in a flux tube fragmentation. Therefore, the local conservation of momentum will lead to a suppression of azimuthal two-pion correlation $dN/(d\Delta \phi\, d\Delta y)$ on the near side at $(\Delta \phi, \Delta y) \sim 0$, but an enhanced azimuthal correlation on the back-to-back, away side at $(\Delta \phi$$\sim$$ \pi,\Delta y$$\sim$0). Similarly, in a flux tube fragmentation, the local conservation of charge will forbid the production of like charge pions within $|\Delta y | < 1/(dN_\pi/dy)$, but there is no such prohibition for $|\Delta y| >1/(dN_\pi/dy)$. These properties may be used as the signature for the fragmentation of a color flux tube.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First lattice QCD study of the gluonic structure of light nuclei

The role of gluons in the structure of the nucleon and light nuclei is investigated using lattice quantum chromodynamics (QCD) calculations. The first moment of the unpolarised gluon distribution is studied in nuclei up to atomic number $A=3$ at quark masses corresponding to pion masses of $m_\pi\sim 450$ and $806$ MeV. Nuclear modification of this quantity defines a gluonic analogue of the EMC effect and is constrained to be less than $\sim 10$% in these nuclei. This is consistent with expectations from phenomenological quark distributions and the momentum sum rule. In the deuteron, the combination of gluon distributions corresponding to the $b_1$ structure function is found to have a small first moment compared with the corresponding momentum fraction. The first moment of the gluon transversity structure function is also investigated in the spin-1 deuteron, where a non-zero signal is observed at $m_\pi \sim 806$ MeV. In conclusion, this is the first indication of gluon contributions to nuclear structure that can not be associated with an individual nucleon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hysteresis Relation between Turbulence and Temperature Modulation during the Heat Pulse Propagation into a Magnetic Island in DIII-D

Here, the hysteresis relation between turbulence and temperature modulation during the heat pulse propagation into a magnetic island is studied for the first time in toroidal plasmas. Lissajous curves of the density fluctuation ($\sim\atop{n}$/n) and the electron temperature (T e ) modulation show that the ($\sim\atop{n}$/n) propagation is faster than the heat pulse propagation near the O-point of the magnetic island. This faster $\sim\atop{n}$/n propagation is an experimental evidence of the turbulence spreading from X-point to the O-point of the magnetic island.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical Model Development and Validation for the WECCCOMP Control Competition

This paper details the development and validation of a numerical model of the Wavestar wave energy converter (WEC) developed in WEC-Sim. This numerical model was developed in support of the WEC Control Competition (WECCCOMP), a competition with the objective of maximizing WEC performance over costs through innovative control strategies. WECCCOMP has two stages: numerical implementation of control strategies, and experimental implementation. The work presented in this paper is for support of the numerical implementation, where contestants are provided a WEC-Sim model of the 1:20 scale Wavestar device to develop their control algorithms. This paper details the development of the numerical model in WEC-Sim and of its validation through comparison to experimental data.

16 TIDAL AND WAVE POWER↗

Gas cluster ion beam for the characterization of organic materials in submarine basalts as Mars analogs

The solar system contains large quantities of organic compounds that can form complex molecular structures. The processing of organic compounds by biological systems leads to molecules with distinctive structural characteristics; thus, the detection and characterization of organic materials could lead to a high degree of confidence in the existence of extra-terrestrial life. Given the nature of the surface of most planetary bodies in the solar system, evidence of life is more likely to be found in the subsurface where conditions are more hospitable. Basalt is a common rock throughout the solar system and the primary rock type on Mars and Earth. Basalt is therefore a rock type that subsurface life might exploit and as such a suitable material for the study of methods required to detect and analyze organic material in rock. Telluric basalts from Earth represent an analog for extra-terrestrial rocks where the indigenous organic matter could be analyzed for molecular biosignatures. This study focuses on organic matter in the basalt with the use of surface analysis techniques utilizing Ar gas cluster ion beams (GCIB); time of flight secondary ion mass spectrometry (ToF-SIMS), and x-ray photoelectron spectroscopy (XPS), to characterize organic molecules. Tetramethylammonium hydroxide (TMAH) thermochemolysis was also used to support the data obtained using the surface analysis techniques. The authors demonstrate that organic molecules were found to be heterogeneously distributed within rock textures. A positive correlation was observed to exist between the presence of microtubule textures in the basalt and the organic compounds detected. From the results herein, the authors propose that ToF-SIMS with an Ar GCIB is effective at detecting organic materials in such geological samples, and ToF-SIMS combined with XPS and TMAH thermochemolysis may be a useful approach in the study of extra-terrestrial organic material and life.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ , in vivo , and in operando imaging and spectroscopy of liquids using microfluidics in vacuum

This review offers a succinct overview of the development of a vacuum-compatible microfluidic reactor system for analysis at the liquid vacuum interface (SALVI), and its diverse applications in in situ, in vivo, and in operando imaging of liquid surfaces as well as the air-liquid (a-l), liquid-liquid (l-l), and solid-liquid (s-l) interfaces in the past decade. SALVI is one of the first microfluidics-based reactors that has enabled direct analysis of volatile liquids in vacuum surface tools such as scanning electron microscopy (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Its integration into ambient and vacuum spectroscopy and microscopy is illustrated. Several applications are highlighted including (1) imaging nanoparticles in liquid using in situ SEM; (2) mapping the evolving l-l interface using in situ x-ray absorption spectroscopy and ToF-SIMS; (3) following complex a-l interfacial oxidation reaction products using in situ ToF-SIMS; (4) capturing biological interfaces of cells and microbes via in vivo multimodal and correlative imaging; and (5) monitoring the dynamic solid electrode and liquid electrolyte interface using in operando molecular imaging. Finally, outlook and recommendations are presented. Besides showing the holistic information volume obtained by real-time multiplexed imaging, this review intends to convey the importance of tool development in revolutionizing surface and interface analysis using vacuum platforms previously limited to solid surfaces. Microfluidics is manifested to be not limited to ambient conditions in many examples in this review. Moreover, fundamental interfacial phenomena underpinning mass and charge transfer can now be pursued in real time via innovated chemical imaging and spectroscopy.

42 ENGINEERING↗

SU-E-T-161: Evaluation of Dose Calculation Based On Cone-Beam CT

Purpose: The purpose of this study is to convert pixel values in cone-beam CT (CBCT) using histograms of pixel values in the simulation CT (sim-CT) and the CBCT images and to evaluate the accuracy of dose calculation based on the CBCT. Methods: The sim-CT and CBCT images immediately before the treatment of 10 prostate cancer patients were acquired. Because of insufficient calibration of the pixel values in the CBCT, it is difficult to be directly used for dose calculation. The pixel values in the CBCT images were converted using an in-house program. A 7 fields treatment plans (original plan) created on the sim-CT images were applied to the CBCT images and the dose distributions were re-calculated with same monitor units (MUs). These prescription doses were compared with those of original plans. Results: In the results of the pixel values conversion in the CBCT images,the mean differences of pixel values for the prostate,subcutaneous adipose, muscle and right-femur were −10.78±34.60, 11.78±41.06, 29.49±36.99 and 0.14±31.15 respectively. In the results of the calculated doses, the mean differences of prescription doses for 7 fields were 4.13±0.95%, 0.34±0.86%, −0.05±0.55%, 1.35±0.98%, 1.77±0.56%, 0.89±0.69% and 1.69±0.71% respectively and as a whole, the difference of prescription dose was 1.54±0.4%. Conclusion: The dose calculation on the CBCT images achieve an accuracy of <2% by using this pixel values conversion program. This may enable implementation of efficient adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-C-17A-03: Evaluation of Deformable Image Registration Methods Between MRI and CT for Prostate Cancer Radiotherapy

Purpose: We evaluated the performance of two commercially available and one open source B-Spline deformable image registration (DIR) algorithms between T2-weighted MRI and treatment planning CT using the DICE indices. Methods: CT simulation (CT-SIM) and MR simulation (MR-SIM) for four prostate cancer patients were conducted on the same day using the same setup and immobilization devices. CT images (120 kVp, 500 mAs, voxel size = 1.1x1.1x3.0 mm3) were acquired using an open-bore CT scanner. T2-weighted Turbo Spine Echo (T2W-TSE) images (TE/TR/α = 80/4560 ms/90°, voxel size = 0.7×0.7×2.5 mm3) were scanned on a 1.0T high field open MR-SIM. Prostates, seminal vesicles, rectum and bladders were delineated on both T2W-TSE and CT images by the attending physician. T2W-TSE images were registered to CT images using three DIR algorithms, SmartAdapt (Varian), Velocity AI (Velocity) and Elastix (Klein et al 2010) and contours were propagated. DIR results were evaluated quantitatively or qualitatively by image comparison and calculating organ DICE indices. Results: Significant differences in the contours of prostate and seminal vesicles were observed between MR and CT. On average, volume changes of the propagated contours were 5%, 2%, 160% and 8% for the prostate, seminal vesicles, bladder and rectum respectively. Corresponding mean DICE indices were 0.7, 0.5, 0.8, and 0.7. The intraclass correlation coefficient (ICC) was 0.9 among three algorithms for the Dice indices. Conclusion: Three DIR algorithms for CT/MR registration yielded similar results for organ propagation. Due to the different soft tissue contrasts between MRI and CT, organ delineation of prostate and SVs varied significantly, thus efforts to develop other DIR evaluation metrics are warranted. Conflict of interest: Submitting institution has research agreements with Varian Medical System and Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-E-J-231: Comparison of Delineation Variability of Soft Tissue Volume and Position in Head-And-Neck Between Two T1-Weighted Pulse Sequences Using An MR-Simulator with Immobilization

Purpose: There is growing interests in applying MR-simulator(MR-sim) in radiotherapy but MR images subject to hardware, patient and pulse sequence dependent geometric distortion that may potentially influence target definition. This study aimed to evaluate the influence on head-and-neck tissue delineation, in terms of positional and volumetric variability, of two T1-weighted(T1w) MR sequences on a 1.5T MR-sim Methods: Four healthy volunteers were scanned (4 scans for each on different days) using both spin-echo (3DCUBE, TR/TE=500/14ms, TA=183s) and gradient-echo sequences (3DFSPGR, TE/TR=7/4ms, TA=173s) with identical coverage, voxel-size(0.8×0.8×1.0mm3), receiver-bandwidth(62.5kHz/pix) and geometric correction on a 1.5T MR-sim immobilized with personalized thermoplastic cast and head-rest. Under this setting, similar T1w contrast and signal-to-noise ratio were obtained, and factors other than sequence that might bias image distortion and tissue delineation were minimized. VOIs of parotid gland(PGR, PGL), pituitary gland(PIT) and eyeballs(EyeL, EyeR) were carefully drawn, and inter-scan coefficient-of-variation(CV) of VOI centroid position and volume were calculated for each subject. Mean and standard deviation(SD) of the CVs for four subjects were compared between sequences using Wilcoxon ranksum test. Results: The mean positional(<4%) and volumetric(<7%) CVs varied between tissues, majorly dependent on tissue inherent properties like volume, location, mobility and deformability. Smaller mean volumetric CV was found in 3DCUBE, probably due to its less proneness to tissue susceptibility, but only PGL showed significant difference(P<0.05). Positional CVs had no significant differences for all VOIs(P>0.05) between sequences, suggesting volumetric variation might be more sensitive to sequence-dependent delineation difference. Conclusion: Although 3DCUBE is considered less prone to tissue susceptibility-induced artifact and distortion, our preliminary data showed that both sequences had insignificant differences on positional and volumetric CV in most head-and-neck tissues except for PGL. This study is majorly limited in its small sample size. Influences of image contrasts(T1w v.s. T2w) and inter-observer difference have to be further investigated.

60 APPLIED LIFE SCIENCES↗

TU-EF-204-01: Accurate Prediction of CT Tube Current Modulation: Estimating Tube Current Modulation Schemes for Voxelized Patient Models Used in Monte Carlo Simulations

Purpose: Most patient models used in Monte Carlo-based estimates of CT dose, including computational phantoms, do not have tube current modulation (TCM) data associated with them. While not a problem for fixed tube current simulations, this is a limitation when modeling the effects of TCM. Therefore, the purpose of this work was to develop and validate methods to estimate TCM schemes for any voxelized patient model. Methods: For 10 patients who received clinically-indicated chest (n=5) and abdomen/pelvis (n=5) scans on a Siemens CT scanner, both CT localizer radiograph (“topogram”) and image data were collected. Methods were devised to estimate the complete x-y-z TCM scheme using patient attenuation data: (a) available in the Siemens CT localizer radiograph/topogram itself (“actual-topo”) and (b) from a simulated topogram (“sim-topo”) derived from a projection of the image data. For comparison, the actual TCM scheme was extracted from the projection data of each patient. For validation, Monte Carlo simulations were performed using each TCM scheme to estimate dose to the lungs (chest scans) and liver (abdomen/pelvis scans). Organ doses from simulations using the actual TCM were compared to those using each of the estimated TCM methods (“actual-topo” and “sim-topo”). Results: For chest scans, the average differences between doses estimated using actual TCM schemes and estimated TCM schemes (“actual-topo” and “sim-topo”) were 3.70% and 4.98%, respectively. For abdomen/pelvis scans, the average differences were 5.55% and 6.97%, respectively. Conclusion: Strong agreement between doses estimated using actual and estimated TCM schemes validates the methods for simulating Siemens topograms and converting attenuation data into TCM schemes. This indicates that the methods developed in this work can be used to accurately estimate TCM schemes for any patient model or computational phantom, whether a CT localizer radiograph is available or not. Funding Support: NIH Grant R01-EB017095; Disclosures - Michael McNitt-Gray: Institutional Research Agreement, Siemens AG; Research Support, Siemens AG; Consultant, Flaherty Sensabaugh Bonasso PLLC; Consultant, Fulbright and Jaworski; Disclosures - Cynthia McCollough: Research Grant, Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-F-J-153: ACR MRI Phantom Test On a 1.5T MR-Simulator with Flexible Coils Setting and Performance Comparison to Volumetric Head Coil Setting

Purpose: To accommodate head-and-neck (HN) RT simulation scan with immobilization, sub-optimized flexible radiofrequency coils have to be used on an MR-sim rather than a volumetric head coil for diagnostic radiological (DR) applications. In this study, we present and compare ACR MRI phantom test with flexible coils setting (RT-setting) and volumetric head coil setting (DR-setting). Methods: Two 8-channel array coils were wrapped close to an ACR MRI phantom placed on a flat couch-top in RT-setting for acquisition. ACR MRI phantom tests were conducted 10 times for each setting on a 1.5T MR-sim. Sagittal localizer (TE/TR=20/200ms), axial T1 (TE/TR=20/500ms) and T2 scans (2TEs/TR=20,80/2000ms) were acquired (NEX=1). Acqusition and image analysis were conducted following ACR guidelines. Extra 10 RT-setting acquisitions were obtained by enabling prescan normalization. Results: For RT-setting without prescan normalization, all tests passed the ACR recommended criteria but image intensity uniformity. Geometric accuracy was 147.8±0.3mm and 191.0±0.4mm. Spatial resolution was 0.9mm. Slice thickness was 5.2mm±0.1mm (T1) and 5.1±0.1mm (T2). Slice position accuracy was 1.4±0.6mm, −2.2±0.3mm (T1), and 1.5±0.2mm, −2.2±0.2mm (T2). Image uniformity was 80.6%±2.6% (T1) and 80.2%±3.1% (T2) (criteria: ≥87.5% for 1.5T). Ghosting ratio was 0.0006±0.0004. Low contrast detectability was 30.7±1.7 (T1) and 22.6±3.0 (T2). Image uniformity (91.4%±4.2% and 91.8%±4.3%) and low contrast detectability (36.5±1.4 and 31.6±2.2) of DR-setting were better than RT-setting. Prescan normalization substantially improved image uniformity to 93.4%±0.2% and 93.4%±0.3%, but slightly compromised ghosting (0.0033±0.0004) and spatial resolution (0.9mm or 1.0mm) for RT-setting. Conclusion: Flexible coils setting for HN-RT simulation scan could successfully pass ACR criteria (prescan normalization enabled) and generally achieve comparable performance to volumetric coil setting, although compromise on low contrast detectability was observed probably due to the lower signal-to-noise ratio of the flexible coils. Our results could also serve as a reference baseline of high-field MR-sim QA performance under ACR guideline.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-15: Is the Reproducibility with Respect to Bone of Tumor Position at Simulation for Breath Hold CT Scans Correlated to the Reproducibility for Multiple Breath Hold CBCTs at Treatment in SBRT Thoracic Patients?

Purpose: To evaluate correlation between the reproducibility of tumor position under feedback guided voluntary deep inspiration breath hold gating at simulation and at treatment. Methods: All patients treated with breath hold (BH) have 3-6 BH CTs taken at simulation (sim). In addition, if the relationship between the tumor and nearby bony anatomy on treatment BH CT(or CBCT) is found to be greater than 5 mm different at treatment than it was at sim, a repeat BH CT is taken before treatment. We retrospectively analyzed the sim CTs for 19 patients who received BH SBRT lung treatments and had repeat BH CT on treatment. We evaluated the reproducibility of the tumor position during the simulation CTs and compared this to the reproducibility of the tumor position on the repeat treatment CT with our in-house CT alignment software (CT-Assisted Targeting for Radiotherapy). Results: Comparing the tumor position for multiple simulation BH CTs, we calculated: maximum difference (max) = 0.69cm; average difference (x) = 0.28cm; standard deviation (σ) = 0.18cm. Comparing the repeat BH CBCTs on treatment days we calculated: max = 0.44cm; x = 0.16cm; σ = 0.22cm. We also found that for 95% of our BH cases, the absolute variation in tumor position within the same imaging day was within 5mm of the range at the time of simulation and treatment. We found that 75% of the BH cases had less residual tumor motion on treatment days than at simulation. Conclusion: This suggests that a GTV contour based upon the residual tumor motion in multiple BH datasets plus 2 mm margin should be sufficient to cover the full range of residual tumor motion on treatment days.

60 APPLIED LIFE SCIENCES↗