Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SUSPECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Substantial crystalline topology in amorphous silicon.

Using electron correlograph analysis we show that coherent nanodiffraction patterns from sputtered amorphous silicon indicate that there is more local crystallinity in unannealed amorphous silicon than was previously suspected. By comparing with simulations for various models we show that within a typical unannealed amorphous silicon film a substantial volume fraction (>50%) is topologically crystalline with correlation lengths up to 2 nm. Electron correlograph analysis is a variant of the fluctuation electron microscopy technique and its sensitivity to local crystalline ordering is derived from its sensitivity to four-body correlations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SCEDS: protein fragments for molecular replacement in Phaser

Protein fragments suitable for use in molecular replacement can be generated by normal-mode perturbation, analysis of the difference distance matrix of the original versus normal-mode perturbed structures, and SCEDS, a score that measures the sphericity, continuity, equality and density of the resulting fragments. A method is described for generating protein fragments suitable for use as molecular-replacement (MR) template models. The template model for a protein suspected to undergo a conformational change is perturbed along combinations of low-frequency normal modes of the elastic network model. The unperturbed structure is then compared with each perturbed structure in turn and the structurally invariant regions are identified by analysing the difference distance matrix. These fragments are scored with SCEDS, which is a combined measure of the sphericity of the fragments, the continuity of the fragments with respect to the polypeptide chain, the equality in number of atoms in the fragments and the density of C{sup α} atoms in the triaxial ellipsoid of the fragment extents. The fragment divisions with the highest SCEDS are then used as separate template models for MR. Test cases show that where the protein contains fragments that undergo a change in juxtaposition between template model and target, SCEDS can identify fragments that lead to a lower R factor after ten cycles of all-atom refinement with REFMAC5 than the original template structure. The method has been implemented in the software Phaser.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exploring the speed and performance of molecular replacement with AMPLE using QUARK ab initio protein models

Two ab initio modelling programs solve complementary sets of targets, enhancing the success of AMPLE with small proteins. AMPLE clusters and truncates ab initio protein structure predictions, producing search models for molecular replacement. Here, an interesting degree of complementarity is shown between targets solved using the different ab initio modelling programs QUARK and ROSETTA. Search models derived from either program collectively solve almost all of the all-helical targets in the test set. Initial solutions produced by Phaser after only 5 min perform surprisingly well, improving the prospects for in situ structure solution by AMPLE during synchrotron visits. Taken together, the results show the potential for AMPLE to run more quickly and successfully solve more targets than previously suspected.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An integrated mobile system for port security

An integrated mobile system for port security is presented. The system is designed to perform active investigations, by using the tagged neutron inspection technique, of suspect dangerous materials as well as passive measurements of neutrons and gamma rays to search and identify radioactive and special nuclear materials. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delayed neutron fraction and prompt decay constant measurement in the MINERVE reactor using the PSI instrumentation

The critical decay constant (B/A), delayed neutron fraction (B) and generation time (A) of the Minerve reactor were measured by the Paul Scherrer Institut (PSI) and the Commissariat a l'Energie Atomique (CEA) in September 2014 using the Feynman-alpha and Power Spectral Density neutron noise measurement techniques. Three slightly subcritical configuration were measured using two 1-g {sup 235}U fission chambers. This paper reports on the results obtained by PSI in the near critical configuration (-2g). The most reliable and precise results were obtained with the Cross-Power Spectral Density technique: B = 708.4±9.2 pcm, B/A = 79.0±0.6 s{sup -1} and A 89.7±1.4 micros. Predictions of the same kinetic parameters were obtained with MCNP5-v1.6 and the JEFF-3.1 and ENDF/B-VII.1 nuclear data libraries. On average the predictions for B and B/A overestimate the experimental results by 5% and 11%, respectively. The discrepancy is suspected to come from either a corruption of the data or from the inadequacy of the point kinetic equations to interpret the measurements in the Minerve driven system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AlN/SiC MEMS for High-Temperature Applications

The creation of microelectromechanical systems (MEMS) that can operate through elevated temperatures would enable systems diagnostics and controls that are not possible with conventional-off-the-shelf components. The integration of silicon carbide (SiC) with aluminum nitride (AlN) has led to the fabrication of devices that can withstand elevated temperature anneals >935 °C. The results from a piezoelectric micromachined ultrasonic transducer (PMUT) and a microresonator are reported as demonstrations of the fabrication process. Testing the PMUT response before and after annealing at 935 °C led to a change in resonant frequency of less than 1%, which is attributable to a shift in film stress. The response of the microresonator was RF tested in situ up to 500 °C and showed no degradation in its electromechanical coupling coefficient. The resonant frequency decreased with temperature due to the temperature coefficient of Young's modulus, and the quality factor decreased with temperature and remained unrecoverable upon cooling. The degradation in the quality factor is suspected to be a result of oxidation of the titatium nitride (TiN) top electrode, which increases the resistivity and leads to an unrecoverable reduction in the quality factor. As a result, the robust piezoelectric response of AlN at these temperatures show that AlN is a very promising candidate for elevated temperature applications. [2019-0019]

42 ENGINEERING↗

Materials characterisation with the associated particle technique

Since the last past years, the Nuclear Measurement Laboratory of CEA Cadarache, France, together with Partners from European and National projects, has been studying the application of fast neutron interrogation with the Associated Particle Technique for material identification in different areas of homeland and maritime security, and for the characterisation of the materials constituting radioactive waste. Fast 14 MeV neutrons are produced from the H-3(H-2,n)alpha fusion reaction in a sealed tube neutron generator embedding an alpha detector. The alpha particle is used to tag neutron direction and emission time, thus allowing the electronic selection of neutron-induced gamma spectra in the voxels of interest. Gamma rays emitted by tagged neutron interactions on the present nuclei (C, O, N, Fe, Al, Si, Cl, etc.) are recorded with spectroscopic detectors and analysed to determine elemental proportions, thus allowing material identification. Investigations have been conducted for the detection of explosives, illicit drugs and contraband materials in cargo containers, for the inspection of objects lying on the sea floor suspected to contain explosives like mines, bombs, torpedoes, etc., for the recognition of an improvised chemical device, and for material identification in radioactive waste packages. Recently the detection of special nuclear materials is being investigated using time correlation analysis between induced fission particles, instead of gamma-ray spectroscopy. The paper presents an overview of these studies and last results. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating Synthetic Smart Meter Locations For Communication System Modeling

An important part of good communication models for smart grid applications, particularly when wireless protocols are used, is the location information of the nodes. We’ve developed metrics to assist in evaluating whether a given model with such information is representative of feeders found in the world. These metrics are applied to a set of feeder models with known good location information for the smart meter locations and compared to a set of feeder models with similar location information that is not expected to be representative of real-world feeders. The comparison reveals that the suspect models do not pass statistical tests utilizing the developed metrics, providing initial validation of the analysis technique.

smart meter, feeder model, GridLAB-D↗

Identifying Reverse-Bias Breakdown Sites in CuInxGa(1-x)Se2

CIGS mini-modules are stressed under reverse bias, resembling partial shading conditions, to predict and characterize where failure occurs. Partial shading can cause permanent damage in the form of 'wormlike' defects on thin-film modules due to thermal runaway. We use electroluminescence (EL) imaging and dark lock-in thermography (DLIT) to supplement current-voltage curves when reverse-bias breakdown occurs on various CIGS minimodules. For better understanding of how these defects originate and propagate, we have implemented a current-limited, reverse-bias stressing technique. This allowed for DLIT-based detection and detailed study of the region where breakdown initiates before thermal runaway leads to permanent damage. A correlation between suspected defect sites and actual breakdown has been determined using this method.

14 SOLAR ENERGY↗

Test Results of the First US ITER TF Conductor in SULTAN

The US Domestic Agency is one of six parties supplying TF cable-in-conduit conductors (CICCs) for ITER. Previous tests have shown that measured performance of the TF CICCs can be much lower than expected from the strand properties at the projected uniaxial strain and that the cabling pattern may also be an important factor. Worst of all, voltage signals well below the expected critical surface could not be reliably interpreted or canceled, making test results very suspect. The TFUS1 sample was prepared to achieve multiple goals: (1) to ensure uniform current distribution and to eliminate parasitic voltage signals by improving joints, (2) to explore the potential benefits of a different cabling pattern for better support of strain-sensitive strands, and (3) to explore the source of voltage development in the cable through the use of innovative penetrating diagnostics. Test results of the first US-made samples are presented and discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparison of Nb 3 Sn Insulation Systems With as Received and De-Sized Glass

Epoxy cracking has been the main suspected contributor to training in Nb 3 Sn magnets for some time, as it leads to energy release and magnet quenching. Cracking in a superconducting composite can occur from several modes, and the likelihood of these modes is not well understood. Failure has been observed between insulation systems and the superconducting cable itself rather than within the cable or insulation. To target the behavior at the interface, samples have been fabricated and tested for Mode I fracture toughness in an adapted version of ASTM D5528. This work seeks to better characterize the fracture toughness of this interface to better understand how to model and design insulation systems.

Krave, Steven T. [Fermilab] (ORCID:000000021752145↗

Adaptive Visual Sort and Summary of Micrographic Images of Nanoparticles for Forensic Analysis

Forensic analysis of nanoparticles is often conducted through the collection and identifi- cation of electron microscopy images to determine the origin of suspected nuclear material. Each image is carefully studied by experts for classification of materials based on texture, shape, and size. Manually inspecting large image datasets takes enormous amounts of time. However, automatic classification of large image datasets is a challenging problem due to the complexity involved in choosing image features, the lack of training data available for effective machine learning methods, and the availability of user interfaces to parse through images. Therefore, a significant need exists for automated and semi-automated methods to help analysts perform accurate image classification in large image datasets. We present INStINCt, our Intelligent Signature Canvas, as a framework for quickly organizing image data in a web based canvas framework. Images are partitioned using small sets of example images, chosen by users, and presented in an optimal layout based on features derived from convolutional neural networks.

active canvas↗

Scheduled Sequential Compressed Spectrum Sensing for Wideband Cognitive Radios

The support for high data rate applications with the cognitive radio technology necessitates wideband spectrum sensing. However, it is costly to apply long-term wideband sensing and is especially difficult in the presence of uncertainty, such as high noise, interference, outliers, and channel fading. In this paper, we propose scheduling of sequential compressed spectrum sensing which jointly exploits compressed sensing (CS) and sequential periodic detection techniques to achieve more accurate and timely wideband sensing. Instead of invoking CS to reconstruct the signal in each period, our proposed scheme performs backward grouped-compressed-data sequential probability ratio test (backward GCD-SPRT) using compressed data samples in sequential detection, while CS recovery is only pursued when needed. This method on one hand significantly reduces the CS recovery overhead, and on the other takes advantage of sequential detection to improve the sensing quality. Furthermore, we propose (a) an in-depth sensing scheme to accelerate sensing decision-making when a change in channel status is suspected, (b) a block-sparse CS reconstruction algorithm to exploit the block sparsity properties of wide spectrum, and (c) a set of schemes to fuse results from the recovered spectrum signals to further improve the overall sensing accuracy. Finally, extensive performance evaluation results show that our proposed schemes can significantly outperform peer schemes under sufficiently low SNR settings.

42 ENGINEERING↗

Real-Time Compton Imaging for the GammaTracker Handheld CdZnTe Detector

We are currently developing a handheld radioisotope identifier containing 18 position-sensitive CdZnTe crystals. In addition to isotope identification, the device performs basic Compton imaging to determine the location of suspected sources. This paper presents two computationally efficient algorithms for this purpose. The first algorithm traces individual Compton cones onto the unit sphere, whereas the second algorithm computes the intersection of two Compton cones and the unit sphere. Simulations demonstrate that the algorithms are suitable for determining the directionality, even with features such as uncertainty calculations omitted. The one-cone algorithm works more efficiently at high count rates, but the two-cone algorithm generates fewer image artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Point Kinetics Model for Estimating Neutron Multiplication of Bare Uranium Metal in Tagged Neutron Measurements

An extension of the point kinetics model is developed in this paper to describe the neutron multiplicity response of a bare uranium object under interrogation by an associated particle imaging deuterium-tritium (D-T) measurement system. This extended model is used to estimate the total neutron multiplication of the uranium. Both MCNPX-PoliMi simulations and data from active interrogation measurements of highly enriched and depleted uranium geometries are used to evaluate the potential of this method and to identify the sources of systematic error. The detection efficiency correction for measured coincidence response is identified as a large source of systematic error. If the detection process is not considered, results suggest that the method can estimate total multiplication to within 13% of the simulated value. Values for multiplicity constants in the point kinetics equations are sensitive to enrichment due to (n, xn) interactions by D-T neutrons and can introduce another significant source of systematic bias. This can theoretically be corrected if isotopic composition is known a priori. Finally, the spatial dependence of multiplication is also suspected of introducing further systematic bias for high multiplication uranium objects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal neutron-induced single-event upsets in microcontrollers containing boron-10

Single-event upsets (SEUs) were measured in thermal neutron-irradiated microcontrollers with 65-nm node and 130-nm node SRAMs. The suspected upset mechanism is charge deposition from the energetic byproducts of 10 B thermal neutron capture. Although elemental analysis confirmed that both microcontrollers contain 10 B, only the 65-nm node microcontroller exhibited a strong response to thermal neutrons. Monte Carlo simulations were performed to investigate the effects of 11 B enrichment on thermal neutron-induced SEUs in a 65-nm SRAM node when boron is present in the p -type well, p -type source and drain, or tungsten plug. Simulations indicate that the byproducts of 10 B(n,α) 7 Li reactions are capable of generating sufficient charge to upset a 65-nm SRAM. Finally, the highest amount of charge deposition from 10 B(n,α) 7 Li reaction byproducts occurs when natural boron is used to dope the p -type source and drain regions. Simulations also show that the SEU cross section is non-negligible when 11 B-enriched boron is used for doping.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗