Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Improving the PMU Standard

The Phasor Measurement Unit (PMU) is perhaps the first representational measurement widely dispersed in the electric power system. Its usefulness has been demonstrated on many occasions. It is shown in this paper that the excellent performance of the PMU is a tribute to PMU makers, and not attributable to the standards that are supposed to specify the performance. The IEEE and IEC standards illustrate, by means of a “reference model,” how a PMU can be made. Both standards base the model on two fundamental conceptual errors. Without these errors several improvements in performance could be made. The standards should be revised to remove the restrictive “guidance” that the reference model presently offers, and to correct the text so that the appropriate concepts are presented.

Phasor Measurement, reference model↗

Optimization-Based Model Reduction Scheme for Renewable Energy Power Plants Using Standardized Testing Scenarios

This paper presents an optimization-based model reduction scheme for renewable energy (RE) power plants consisting of inverter-based resources (IBRs) operating in grid-following (GFL) or grid-forming (GFM) modes. More importantly, the datasets feeding the optimization-based model reduction scheme are generated and re-used through the standardized grid-interactive testing scenarios. Particularly, the proposed scheme makes use of the power plant point of common coupling (PCC) measurements of various quantities specified by standardized tests (e.g., voltage and frequency ride through) as per IEEE 2800, to estimate the parameters of the reduced-order model such that its dynamic performance aligns with the original detailed power plant model. The proposed model reduction approach does not require the parameters of individual IBRs and using standardized test data as input to the formulated optimization problem simplifies the reduced-order modelling scheme. Extensive case studies following standardized test scenarios verified the remarkable accuracy of the proposed approach.

Yallamilli, Ram S. [Purdue University]↗

Real-Time Hardware-in-the-Loop Distributed Energy Resources System Testbed using IEEE 2030.5 Standard

IEEE 2030.5 standard is drawing special attention among communication protocols for smart inverters and distributed energy resources (DER). Moreover, California Rule 21 mandates new DER must be ready to communicate to a host utility using the IEEE 2030.5 standard. Therefore, development of an effective real-time simulation method for managing DER using IEEE 2030.5 network is crucial. This paper presents a real-time hardware-in-the-loop (HIL) DER system testbed using the IEEE 2030.5 standard. The proposed real-time co-simulation testbed consists of a DER physical system simulation using OP AL-RT real-time simulator and a cyber system simulation including DER gateways and a DER management system (DERMS) cloud server. Custom-built client and server programs are developed to meet the compliant with IEEE 2030.5-2018 standard and implemented in the DER gateways and a DERMS server, respectively. Furthermore, the feasibility of the proposed testbed for DER systems is validated by experiments.

42 ENGINEERING↗

The Effect of 1–10-MeV Neutrons on the JESD89 Test Standard

Here, the JESD89 test standard defines how terrestrial neutron testing is conducted [1] . The test standard covers a number of different types of radiation used for testing, including protons, neutrons, and alphas, and different types of testing, including life testing and accelerated testing. Broad-spectrum neutron testing is the most common type of accelerated radiation testing for the terrestrial radiation environment. Unlike most test standards, the JESD89 defines the minimum energy for determining the cumulative fluence for the deployed and test environment. Currently, the minimum energy is set at 10 MeV. As the test standard is currently being rewritten, changing the minimum energy to 1 MeV is being explored, because it is believed that the onset to neutron-induced single-event effects (SEEs) is less than 10 MeV. There are three separate problems with lowering the minimum energy: determining whether electronics have a sensitivity to neutron-induced SEEs below 10 MeV, determining whether the test spectra match the terrestrial environment in the 1–10-MeV range, and the measurement error caused by not including the fluence from 1 to 10 MeV. In this paper, we present information on these factors and whether the minimum energy should be lowered to 1 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with aspheric x-ray optics

High-accuracy surface metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate x-ray light with nanometer-scale wavelengths. The current and potential capabilities of x˗ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. Metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for fabrication of slightly curved x-ray optics. However, for even moderately curved aspherical x-ray mirrors the flat-reference calibration is not sufficiently accurate. For micro-stitching interferometry developed for surface measurements with curved x-ray mirrors, the tool aberration errors are known to be transferred into the optical surface topography of x-ray mirrors. Our approach to improving metrology is to thoroughly calibrate the measuring tool and apply the results of the calibration to deconvolution of the measured data. Here we explore the application of a recently developed technique for calibrating the instrument transfer function (ITF) of 3D optical surface profilers to metrology with significantly curved x-ray optics. The technique, based on test standards patterned with two-dimensional (2D) binary pseudo-random arrays (BPRAs), employs the unique properties of the BPRA patterns in the spatial frequency domain. The inherent 2D power spectral density of the pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field of view of an instrument. The high efficacy of the technique has been previously demonstrated in application to metrology with flat and slightly curved optics. Here, we concentrate on development of an efficient fabrication process for production of highly randomized (HR) BPRA test standards on flat and 500-mm spherical optical substrates. We also compare and discuss the results of the ITF calibration of an interferometric microscope when using the HR BPRA standards on flat and curved substrates.

Munechika, Keiko↗

SU-E-T-72: Commissioning of a Standardized SRS Cone Set: Determination of the Bolus Gap Factors in a Passively Scattered Proton Beam

Purpose: To determine the proton output factors for an SRS cone set using standardized apertures and varied range compensators (bolus blanks); specifically, to determine the best method for modeling the bolus gap factor (BGF) and eliminate the need for patient specific calibrations. Methods: A Standard Imaging A-16 chamber was placed in a Plastic Water phantom to measure the change in dose/MU with different treatment combinations for a proton SRS cone, using standardized apertures and range compensators. Measurements were made with all apertures in the SRS cone set, with four different range compensator thicknesses and five different air gaps between the end of the SRS cone and the surface of the phantom. The chamber was located at iso-center and maintained at a constant depth at the center of modulation for all measurements. Each aperture was placed in the cone to measure the change in MU needed to maintain constant dose at the chamber, as the air gap was increased with different thicknesses of bolus. Results: The dose/MU varied significantly with decreasing aperture size, increasing bolus thickness, or increasing air gap. The measured data was fitted with the lowest order polynomials that accurately described the data, to create a model for determining the change in output for any potential combination of devices used to treat a patient. For a given standardized aperture, the BGF could be described by its constituent factors: the bolus thickness factor (BTF) and the nozzle extension factor (NEF). Conclusion: The methods used to model the dose at the calibration point could be used to accurately predict the change in output for SRS proton beams due to the BGF, eliminating the need for patient specific calibrations. This method for modeling SRS treatments could also be applied to model other treatments using passively scattered proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-BRD-10: Lung IMRT Planning Using Standardized Beam Bouquet Templates

Purpose: We investigate the feasibility of choosing from a small set of standardized templates of beam bouquets (i.e., entire beam configuration settings) for lung IMRT planning to improve planning efficiency and quality consistency, and also to facilitate automated planning. Methods: A set of beam bouquet templates is determined by learning from the beam angle settings in 60 clinical lung IMRT plans. A k-medoids cluster analysis method is used to classify the beam angle configuration into clusters. The value of the average silhouette width is used to determine the ideal number of clusters. The beam arrangements in each medoid of the resulting clusters are taken as the standardized beam bouquet for the cluster, with the corresponding case taken as the reference case. The resulting set of beam bouquet templates was used to re-plan 20 cases randomly selected from the database and the dosimetric quality of the plans was evaluated against the corresponding clinical plans by a paired t-test. The template for each test case was manually selected by a planner based on the match between the test and reference cases. Results: The dosimetric parameters (mean±S.D. in percentage of prescription dose) of the plans using 6 beam bouquet templates and those of the clinical plans, respectively, and the p-values (in parenthesis) are: lung Dmean: 18.8±7.0, 19.2±7.0 (0.28), esophagus Dmean: 32.0±16.3, 34.4±17.9 (0.01), heart Dmean: 19.2±16.5, 19.4±16.6 (0.74), spinal cord D2%: 47.7±18.8, 52.0±20.3 (0.01), PTV dose homogeneity (D2%-D99%): 17.1±15.4, 20.7±12.2 (0.03).The esophagus Dmean, cord D02 and PTV dose homogeneity are statistically better in the plans using the standardized templates, but the improvements (<5%) may not be clinically significant. The other dosimetric parameters are not statistically different. Conclusion: It's feasible to use a small number of standardized beam bouquet templates (e.g. 6) to generate plans with quality comparable to that of clinical plans. Partially supported by NIH/NCI under grant #R21CA161389 and a master research grant by Varian Medical System.

60 APPLIED LIFE SCIENCES↗

A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry

Purpose: To evaluate a prototype densitometer traceable to primary optical standards and compare its performance to an EPSON Expression{sup ®} 10000XL flatbed scanner (the Epson) for quantitative radiochromic film (RCF) dosimetry. Methods: A prototype traceable laser densitometry system (LDS) was developed to mitigate common film scanning artifacts, such as positional scan dependence and high noise in low-dose regions, by performing point-based measurements of RCF suspended in free-space using coherent light. The LDS and the Epson optical absorbance scales were calibrated up to 3 AU, using reference materials calibrated at a primary standards laboratory and a scanner calibration factor (SCF). Calibrated optical density (OD) was determined for 96 Gafchromic{sup ®} EBT3 film segments before and after irradiation to one of 16 dose levels between 0 and 10 Gy, exposed to {sup 60}Co in a polymethyl-methacrylate (PMMA) phantom. The sensitivity was determined at each dose level and at two rotationally orthogonal readout orientations to obtain the sensitometric response of each RCF dosimetry system. LDS rotational scanning dependence was measured at nine angles between 0°and 180°, due to the expected interference between coherent light and polarizing EBT3 material. The response curves were fit to the analytic functions predicted by two physical response models: the two-parameter single-hit model and the four-parameter percolation model. Results: The LDS and the Epson absorbance measurements were linear to primary optical standards to within 0.2% and 0.3% up to 2 and 1 AU, respectively. At higher densities, the LDS had an over-response (2.5% at 3 AU) and the Epson an under-response (3.1% and 9.8% at 2 and 3 AU, respectively). The LDS and the Epson SCF over the applicable range were 0.968% ± 0.2% and 1.561% ± 0.3%, respectively. The positional scan dependence was evaluated on each digitizer and shown to be mitigated on the LDS, as compared to the Epson. Maximum EBT3 rotational dependence was found to have a strong dependence on dose (0.1% and 34% at 30 mGy and 5 Gy, respectively). The preferred EBT3 polymerization axis angle was constant within experimental uncertainties. In its most sensitive orientation, the LDS-measured EBT3 sensitivity was 7.13 × 10{sup −4} ± 9.2 × 10{sup −6} AU/mGy, which represented a 4.5 fold increase over the Epson of 1.58 × 10{sup −4} ± 9.8 × 10{sup −6} AU/mGy. To first order approximations, EBT3 response was linear up to 500 mGy to within 0.80% and to within 7.5% for the most sensitive LDS and the Epson orientations, respectively. The corresponding single-hit and percolation model relative residual norms were 0.082 and 0.074 for LDS as compared to 0.29 and 0.18 for the Epson, which represented a significant increase in LDS-measured agreement with the simple physical model. Less sensitive LDS and the Epson orientations showed a marked decrease in the physical model agreement, which suggested that suboptimal readout device characteristics may be the origin of the complex sensitometric functional forms currently required for accurate RCF dosimetry. Conclusions: The prototype densitometer was shown to be superior to a conventional scanner for quantitative RCF dosimetry based on physical models of film response. The Epson was shown to be a reliable tool for routine RCF dosimetry in a clinical setting, yet calibration to primary optical standards did not mitigate the necessity for complex, empirical functional form fitting.

60 APPLIED LIFE SCIENCES↗

SU-B-213-02: Development of CAMPEP Standards

The North American medical physics community validates the education received by medical physicists and the clinical qualifications for medical physicists through accreditation of educational programs and certification of medical physicists. Medical physics educational programs (graduate education and residency education) are accredited by the Commission on Accreditation of Medical Physics Education Programs (CAMPEP), whereas medical physicists are certified by several organizations, the most familiar of which is the American Board of Radiology (ABR). In order for an educational program to become accredited or a medical physicist to become certified, the applicant must meet certain specified standards set by the appropriate organization. In this Symposium, representatives from both CAMPEP and the ABR will describe the process by which standards are established as well as the process by which qualifications of candidates for accreditation or certification are shown to be compliant with these standards. The Symposium will conclude with a panel discussion. Learning Objectives: Recognize the difference between accreditation of an educational program and certification of an individual Identify the two organizations primarily responsible for these tasks Describe the development of educational standards Describe the process by which examination questions are developed GS is Executive Secretary of CAMPEP.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-B-213-05: Development of ABR Certification Standards

The North American medical physics community validates the education received by medical physicists and the clinical qualifications for medical physicists through accreditation of educational programs and certification of medical physicists. Medical physics educational programs (graduate education and residency education) are accredited by the Commission on Accreditation of Medical Physics Education Programs (CAMPEP), whereas medical physicists are certified by several organizations, the most familiar of which is the American Board of Radiology (ABR). In order for an educational program to become accredited or a medical physicist to become certified, the applicant must meet certain specified standards set by the appropriate organization. In this Symposium, representatives from both CAMPEP and the ABR will describe the process by which standards are established as well as the process by which qualifications of candidates for accreditation or certification are shown to be compliant with these standards. The Symposium will conclude with a panel discussion. Learning Objectives: Recognize the difference between accreditation of an educational program and certification of an individual Identify the two organizations primarily responsible for these tasks Describe the development of educational standards Describe the process by which examination questions are developed GS is Executive Secretary of CAMPEP.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-F-CAMPUS-T-04: Implementation of a Standardized Monthly Quality Check for Linac Output Management in a Large Multi-Site Clinic

Purpose: This work is to investigate the feasibility of a standardized monthly quality check (QC) of LINAC output determination in a multi-site, multi-LINAC institution. The QC was developed to determine individual LINAC output using the same optimized measurement setup and a constant calibration factor for all machines across the institution. Methods: The QA data over 4 years of 7 Varian machines over four sites, were analyzed. The monthly output constancy checks were performed using a fixed source-to-chamber-distance (SCD), with no couch position adjustment throughout the measurement cycle for all the photon energies: 6 and 18MV, and electron energies: 6, 9, 12, 16 and 20 MeV. The constant monthly output calibration factor (Nconst) was determined by averaging the machines’ output data, acquired with the same monthly ion chamber. If a different monthly ion chamber was used, Nconst was then re-normalized to consider its different NDW,Co-60. Here, the possible changes of Nconst over 4 years have been tracked, and the precision of output results based on this standardized monthly QA program relative to the TG-51 calibration for each machine was calculated. Any outlier of the group was investigated. Results: The possible changes of Nconst varied between 0–0.9% over 4 years. The normalization of absorbed-dose-to-water calibration factors corrects for up to 3.3% variations of different monthly QA chambers. The LINAC output precision based on this standardized monthly QC relative to the TG-51 output calibration is within 1% for 6MV photon energy and 2% for 18MV and all the electron energies. A human error in one TG-51 report was found through a close scrutiny of outlier data. Conclusion: This standardized QC allows for a reasonably simplified, precise and robust monthly LINAC output constancy check, with the increased sensitivity needed to detect possible human errors and machine problems.

60 APPLIED LIFE SCIENCES↗

Search for standard model production of four top quarks with same-sign and multilepton final states in proton–proton collisions at $\sqrt{s} = 13\,\text {TeV} $

A search for standard model production of four top quarks ( $\mathrm {t}\overline{\mathrm {t}} \mathrm {t}\overline{\mathrm {t}} $ ) is reported using events containing at least three leptons ( $\mathrm {e}, \mathrm {\mu }$ ) or a same-sign lepton pair. The events are produced in proton–proton collisions at a center-of-mass energy of 13 $\,\text {TeV}$ at the LHC, and the data sample, recorded in 2016, corresponds to an integrated luminosity of 35.9 $\,\text {fb}^{-1}$ . Jet multiplicity and flavor are used to enhance signal sensitivity, and dedicated control regions are used to constrain the dominant backgrounds. The observed and expected signal significances are, respectively, 1.6 and 1.0 standard deviations, and the $\mathrm {t}\overline{\mathrm {t}} \mathrm {t}\overline{\mathrm {t}} $ cross section is measured to be $16.9^{+13.8-11.4}$ $\,\text {fb}$ , in agreement with next-to-leading-order standard model predictions. These results are also used to constrain the Yukawa coupling between the top quark and the Higgs boson to be less than 2.1 times its expected standard model value at 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beyond standard model searches in the MiniBooNE experiment

The MiniBooNE experiment has contributed substantially to beyond standard model searches in the neutrino sector. The experiment was originally designed to test the Δ m 2 ~ 1 eV 2 region of the sterile neutrino hypothesis by observing ν e ( ν - e ) charged current quasielastic signals from a ν μ ( ν - μ ) beam. MiniBooNE observed excesses of ν e and ν - e candidate events in neutrino and antineutrino mode, respectively. To date, these excesses have not been explained within the neutrino standard model ( ν SM); the standard model extended for three massive neutrinos. Confirmation is required by future experiments such as MicroBooNE. MiniBooNE also provided an opportunity for precision studies of Lorentz violation. The results set strict limits for the first time on several parameters of the standard-model extension, the generic formalism for considering Lorentz violation. Most recently, an extension to MiniBooNE running, with a beam tuned in beam-dump mode, is being performed to search for dark sector particles. In addition, this review describes these studies, demonstrating that short baseline neutrino experiments are rich environments in new physics searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conduct of Operations and Nuclear Criticality Safety Standards

Since the beginning of the nuclear age in 1943, there have been 22 criticality accidents in process facilities worldwide in which fissionable materials were processed by hand for various purposes. Of these 22 process criticality accidents, 16 involved faulty or flawed conduct of operations. Most of these process accidents (17 of 22) occurred before 1970, mostly due to the implementation of formal conduct of operations—such as the use of operating procedures and training—and the use of consensus standards for nuclear criticality safety (NCS). Obviously, the nuclear facilities applied lessons learned from their accident history, and the rate of criticality accidents was significantly reduced as a result. Over the years, it has been emphasized in NCS training courses and other venues in the United States that the consensus standards, such as ASA N6.1-1964, were the key contributors to this reduction in accidents. The formality of operations required to implement and apply the standards at a facility is also a crucial prerequisite that must be sufficiently robust to ensure NCS. This prerequisite is crucial to success fully implement the NCS consensus and other safety standards at a site.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Progress in the development of the community Particle Accelerator Lattice Standard (PALS)

The Particle Accelerator Lattice Standard (PALS) is a community effort to create an open standard to promote lattice information exchange for particle accelerators. PALS development is a community-wide international effort involving accelerator physicists from multiple institutions. While it started as a lattice standard for beam dynamics simulations, it is now being extended to support other particle accelerator activities, in particular accelerator operation. With new accelerators that are becoming more complex, larger collaborations and the increasing imprint of artificial intelligence in all accelerator activities (from design to operation to workforce development), the imperative for a common, standardized accelerator ontology has been transitioning from “nice-to-have” to “must-have”. We will present the status of the project, its relations to other projects, including to two of the particle accelerator projects of the newly announced US DOE Genesis Mission: the Multi-Office Accelerator Team (MOAT) project and the Nuclear physics AI-Ready Accelerator Data (NARAD) project.

Brynes, A. [Science and Technology Facilities Coun↗

Summary Report: Development of a New ASTM Standard Test Method for Phase Change Materials

An ASTM International task group was formed with representatives from research organizations, PCM and insulation manufacturers, testing laboratories, etc., to develop an ASTM standard test method, using a heat flow meter apparatus (HFMA), to make heat-flow measurements under prescribed dynamic, or non steady-state, conditions. The HFMA is typically used for measuring steady-state thermal transmission properties of materials, following ASTM C518. The new ‘dynamic’ test method is based on a modification of the C518 test method, for measuring volumetric specific heat of regular (i.e. with no PCM) thermal insulation materials. The proposed test method describes the methodology for using a HFMA for measuring thermal storage properties of phase change materials and products. It requires the measurement of non-steady-state heat flow into or out of a flat slab specimen to determine the stored energy (i.e. enthalpy) change as a function of temperature. In particular, this test method is intended to measure the sensible and latent heat storage capacity of products incorporating phase-change materials (PCM). The thermal storage capacity of a PCM is well defined via four parameters: specific heats of both solid and liquid phases, phase change temperature(s) and phase change enthalpy. This report provides brief summaries of the proposed standard test method and the standard development related activities at Oak Ridge National Laboratory (ORNL) during fiscal year 2013 (FY13). The draft standard document is also provided as an appendix.

dynamic testing↗

242 PU Standards Documentation Package

The standards documented in this package are composed of plutonium oxide. One set of standards was fabricated from 84% 242 pu material and the other 89% 242 pu material. They were specifically designed to be used as calibration standards for thermal neutron counters (TNCs). The procedure used to prepare these standards is part of the documentation package.

07 ISOTOPE AND RADIATION SOURCES↗

Development of ASTM Standard for SiC-SiC Joint Testing Final Scientific/Technical Report

As the nuclear industry moves to advanced ceramic based materials for cladding and core structural materials for a variety of advanced reactors, new standards and test methods are required for material development and licensing purposes. For example, General Atomics (GA) is actively developing silicon carbide (SiC) based composite cladding (SiC-SiC) for its Energy Multiplier Module (EM2), a high efficiency gas cooled fast reactor. Through DOE funding via the advanced reactor concept program, GA developed a new test method for the nominal joint strength of an endplug sealed to advanced ceramic tubes, Fig. 1-1, at ambient and elevated temperatures called the endplug pushout (EPPO) test. This test utilizes widely available universal mechanical testers coupled with clam shell heaters, and specimen size is relatively small, making it a viable post irradiation test method. The culmination of this effort was a draft of an ASTM test standard that will be submitted for approval to the ASTM C28 ceramic committee. Once the standard has been vetted by the ceramics test community, an industry wide standard methodology to test joined tubular ceramic components will be available for the entire nuclear materials community.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗