Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STAGNATION PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Owens-Illinois liquid solar collector materials assessment

From the beginning, it was noted that the baseline drawings for the liquid solar collector exhibited a distinct weakness concerning materials specification where elastomers, plastics, and foam insulation materials were utilized. A relatively small effort by a competent design organization would alleviate this deficiency. Based on results obtained from boilout and stagnation tests on the solar simulator, it was concluded that proof testing of the collector tubes prior to use helps to predict their performance for limited service life. Fracture mechanics data are desirable for predicting extended service life and establishing a minimum proof pressure level requirement. The temperature capability of this collector system was increased as the design matured and the coating efficiency improved. This higher temperature demands the use of higher temperature materials at critical locations in the collector.

Nichols, R. L.↗

Two-phase choked flow of cryogenic fluids in converging-diverging nozzles

Data are presented for the two phase choked flow of three cryogenic fluids - nitrogen, methane, and hydrogen - in four converging-diverging nozzles. The data cover a range of inlet stagnation conditions, all single phase, from well below to well above the thermodynamic critical conditions. In almost all cases the nozzle throat conditions were two phase. The results indicate that the choked flow rates were not very sensitive to nozzle geometry. However, the axial pressure profiles, especially the throat pressure and the point of vaporization, were very sensitive to both nozzle geometry and operating conditions. A modified Henry-Fauske model correlated all the choked flow rate data to within + or - 10 percent. Neither the equilibrium model nor the Henry-Fauske model predicted throat pressures well over the whole range of data. Above the thermodynamic critical temperature the homogeneous equilibrium model was preferred for both flow rate and pressure ratio. The data of the three fluids could be normalized by the principle of corresponding states.

Simoneau, R. J.↗

Contraction design for small low-speed wind tunnels

An iterative design procedure was developed for two- or three-dimensional contractions installed on small, low-speed wind tunnels. The procedure consists of first computing the potential flow field and hence the pressure distributions along the walls of a contraction of given size and shape using a three-dimensional numerical panel method. The pressure or velocity distributions are then fed into two-dimensional boundary layer codes to predict the behavior of the boundary layers along the walls. For small, low-speed contractions it is shown that the assumption of a laminar boundary layer originating from stagnation conditions at the contraction entry and remaining laminar throughout passage through the successful designs if justified. This hypothesis was confirmed by comparing the predicted boundary layer data at the contraction exit with measured data in existing wind tunnels. The measured boundary layer momentum thicknesses at the exit of four existing contractions, two of which were 3-D, were found to lie within 10 percent of the predicted values, with the predicted values generally lower. From the contraction wall shapes investigated, the one based on a fifth-order polynomial was selected for installation on a newly designed mixing layer wind tunnel.

Bell, James H.↗

Effects of Hydrodynamics of Soot Formation in Laminar Opposed-Jet Diffusion Flames

Effects of flow (hydrodynamic properties on the presence of soot in hydrocarbon-fueled laminar opposed-jet diffusion flames were studied experimentally at atmospheric pressure, emphasizing effects of velocities normal to the Rom sheet. These velocities were varied for conditions corresponding to combustion in air by transferring nitrogen from the oxidizer stream to the fuel stream which increases the stoichiometric mixture fraction of the flame and causes the stagnation plane of the flow to shift toward the fuel-rich side of the flame sheet. Fuels considered included acetylene, ethylene, ethane, propylene, propane, and 1-3 butadiene. Present measurements consisted of the critical strain rates for the flames to contain soot (the soot extinction limit) and for the flames to extinguish (the flame extinction limit) It was found that increasing the stoichiometric mixture fraction causes a progressive reduction of the critical strain rates for both flame and soot extinction; however, their ratio increases, and even becomes unbounded in most instances to yield a permanently-blue-flame regime. The results suggest that soot formation in nonpremixed flames can be controlled by varying velocities normal to the flame sheet. Nevertheless, definitive conclusions along these lines require evaluation of effects of corresponding variations of fuel and oxygen concentrations on soot formation when velocities normal to the flame sheet are changed by varying stoichiometric mixture fractions for laminar opposed-jet diffusion flames.

Lin, K.-C.↗

1D kinetic study of pinch formation in a dense plasma focus: Transition from collisional to collisionless regimes

Here, the pinch-formation stage of a deuterium dense plasma focus, and associated “shock-flash” neutron yield, is studied using 1D kinetic simulations considering a plasma column with initial pressure P, initial radius R, and the compression to be driven by a constant current I. The relative behavior of the compression is shown to be similar for fixed ratios of the characteristic ion mean free path to the radius of the plasma column at stagnation, $λ_{st}/R_{st}$. This dimensionless parameter is shown to scale like $I^4/(P^3R^5)$. The compression ratio, $R/R_{st}$, is found to be a minimum when $λ_{st}/R_{st} ≈$ 1 and is the largest in the collisionless limit where $λ_{st} \gg R_{st}$. This behavior is in contrast to the analogous planar pinch where R/Rst decreases from one constant for λst/Rst$\ll$1 to a smaller constant for $λ_{st}/R_{st} \gg$ 1. The yield in the collisionless regime is shown to fall between the two well-known $I^4$ scaling laws. Furthermore, this regime exhibits qualities that potentially make it appealing for radiography applications, such as increased localization in time and space of the neutron formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of fuel temperature on supersonic mixing and combustion of hydrogen

Results are presented from an experimental investigation of the influence of fuel stagnation temperature on the mixing and reaction of hydrogen injected transverse to a supersonic flow in a duct. The hydrogen fuel was injected stoichiometrically at stagnation temperatures of 300 K and 800 K from a row of five circular orifices in the duct wall. Detailed measurements in the flow at the duct exit are used to determine the overall amount of mixing accomplished at each of three test conditions. Static pressure distributions are used with duct wall temperatures and heat flux in a one-dimensional analysis to deduce the fraction of fuel reacted along the duct. Results from the one-dimensional analyses of the tests with hot fuel indicated slightly more fuel reacted at the exit; however, differences in the accomplished mixing obtained from integrations of exit surveys were small.

Rogers, R. C.↗

Analysis and calculation by integral methods of laminar compressible boundary-layer with heat transfer and with and without pressure gradient

A survey of integral methods in laminar-boundary-layer analysis is first given. A simple and sufficiently accurate method for practical purposes of calculating the properties (including stability) of the laminar compressible boundary layer in an axial pressure gradient with heat transfer at the wall is presented. For flow over a flat plate, the method is applicable for an arbitrarily prescribed distribution of temperature along the surface and for any given constant Prandtl number close to unity. For flow in a pressure gradient, the method is based on a Prandtl number of unity and a uniform wall temperature. A simple and accurate method of determining the separation point in a compressible flow with an adverse pressure gradient over a surface at a given uniform wall temperature is developed. The analysis is based on an extension of the Karman-Pohlhausen method to the momentum and the thermal energy equations in conjunction with fourth- and especially higher degree velocity and stagnation-enthalpy profiles.

Morduchow, Morris↗

An investigation of a wall-injected scramjet using a shock tunnel

Experimental results are presented for several wall-injected, constant-area scramjet experiments, performed in the T4 free-piston-driven shock tunnel. Stagnation enthalpies range from 5.7 to 10.1 MJ/kg, corresponding to flight Mach numbers of Mach 9.7 to Mach 13. Hydrogen fuel is injected from the rear of a step into a supersonic air stream, with combustion-chamber Mach numbers of 3.6 and 4.4, and static pressures of 40 kPa. The experimental results are compared to numerical predictions obtained from a two-dimensional, parabolic Navier-Stokes code, which modeled turbulence with a compressibility modified k-epsilon model, and used multi-reaction, finite-rate chemistry. The numerical and experimental results show reasonable agreement and indicate that the scramjet flows studied are predominantly mixing limited.

Brescianini, C. P.↗

Blunt Body Near-Wake Flow Field at Mach 10

Tests were conducted in a Mach 10 air flow to examine the reattachment process of a free shear layer associated with the near wake of a 70 deg half angle, spherically blunted cone having a cylindrical after body. The nominal free-stream Reynolds number based on model diameter ranged from 0.25 x l0(exp 6) to 1 x l0(exp 6) and the angle of incidence set at 0 and +/- 20 deg. The present study was designed to complement previously reported Mach 6 perfect air tests as well as results obtained in several hypervelocity facilities capable of producing real gas effects. Surface heating rates were inferred from temperature time histories from coaxial surface thermocouples on the model forebody and thin film resistance gages along the model base and cylindrical after body. Limited forebody, base, and support sting surface pressures were obtained with piezoresistive Experimental results are compared to laminar perfect gas predictions provided by a 3-0 Navier Stokes code (NSHYP). Shear layer impingement on the instrumented cylindrical after body resulted in a localized heating maximum that was 16 to 18percent of the forebody stagnation point and a factor of 2 higher than laminar predictions, suggesting a transitional or turbulent shear layer. transducers.

Horvath, Thomas↗

Defining the Operational Envelope for Air Flows in the Miniature Arc-Jet Research Chamber (mARC II)

The second-generation 30 kW miniature Arc-jet Research Chamber (mARC II) at NASA Ames Research Center produces high enthalpy flows relevant for entry systems ground testing. The mARC II facility has recently undergone upgrades, including the installation of a new vacuum system to address the issues preventing it from maintaining underexpanded flow under test conditions. In this work, we present data obtained from an Integrated Systems Testing campaign and provide an initial assessment of arc-jet performance following the upgrades. Air is used as the working gas for the standard mARC II arc-heater configuration with two constrictor disks. Seven runs were investigated for five test conditions to assess the lowest achievable stagnation point heat fluxes for air flow rates of 0.15 or 0.25 g s −1 . The heat flux was measured using a water-cooled Gardon gauge (Ø4.76 mm, 3/16" hemispherical) at 70 mm from the nozzle exit plane. The new vacuum system produced test box pressures in the medium (fine) vacuum range (~0.03 torr, 4 Pa) prior to gas addition and successfully maintained underexpanded flow after gas addition. The upgrade yielded a ~4X reduction in heat flux relative to the previous system for the same set test conditions. We report the lowest heat fluxes measured in mARC II to date, ranging from 26 to 81 W cm −2 , for sonic flow enthalpies of 4–14 MJ kg −1 . Bulk enthalpies estimated using an energy balance method (EB 2 ) are reported for the first time using mARC II.Initial data suggests EB 2 generally estimates lower enthalpies than sonic flow methods for mARC II. Lastly, laminar axisymmetric Navier–Stokes simulations were performed using the NASA DPLR code. Numerical heat flux results show good agreement with experiments at low arc powers (3–15% difference at the minimum set arc current), but discrepancy increases with arc power (49% difference at the maximum set arc current).

Pitot tube↗

Defining the Operational Envelope for Air Flows in the Miniature Arc-Jet Research Chamber (mARC II)

The second-generation 30 kW miniature Arc-jet Research Chamber (mARC II) at NASA Ames Research Center produces high enthalpy flows relevant for entry systems ground testing. The mARC II facility has recently undergone upgrades, including the installation of a new vacuum system to address the issues preventing it from maintaining underexpanded flow under test conditions. In this work, we present data obtained from an Integrated Systems Testing campaign and provide an initial assessment of arc-jet performance following the upgrades. Air is used as the working gas for the standard mARC II arc-heater configuration with two constrictor disks. Seven runs were investigated for five test conditions to assess the lowest achievable stagnation point heat fluxes for air flow rates of 0.15 or 0.25 g s −1 . The heat flux was measured using a water-cooled Gardon gauge (Ø4.76 mm, 3/16" hemispherical) at 70 mm from the nozzle exit plane. The new vacuum system produced test box pressures in the medium (fine) vacuum range (~0.03 torr, 4 Pa) prior to gas addition and successfully maintained underexpanded flow after gas addition. The upgrade yielded a ~4X reduction in heat flux relative to the previous system for the same set test conditions. We report the lowest heat fluxes measured in mARC II to date, ranging from 26 to 81 W cm −2 , for sonic flow enthalpies of 4–14 MJ kg −1 . Bulk enthalpies estimated using an energy balance method (EB 2 ) are reported for the first time using mARC II.Initial data suggests EB 2 generally estimates lower enthalpies than sonic flow methods for mARC II. Lastly, laminar axisymmetric Navier–Stokes simulations were performed using the NASA DPLR code. Numerical heat flux results show good agreement with experiments at low arc powers (3–15% difference at the minimum set arc current), but discrepancy increases with arc power (49% difference at the maximum set arc current).

arc-jet↗

Energy efficient engine, high-pressure turbine cooling model technology report

Two dimensional flow visualization model tests were used to substantiate the flow stability benefits derived from the use of turning vanes in the root and tip turn flow areas. Results indicate the need for corner fillets and flow injection into the acute corner formed by the intersection of the rib and simulated airfoil suction surface in order to minimize recirculation (stagnation) of flow in that region. Three dimensional flow visualization model tests verified the actual blade coolant passage design.

Gardner, W. B.↗

A new concept for the daytime magnetosphere of Venus

A different type of interaction between the solar wind and the ionosphere of a non-magnetized planet suggested by the Pioneer Venus magnetic field measurements is presented. They found that the magnetic field of the shocked solar wind does not penetrate the ionosphere, and it appears that the latter acts approximately as a superconductor, excluding any substantial penetration of interplanetary magnetic field. Just beyond the ionopause is a magnetized region with little plasma whose magnetic pressure is approximately equal to the impact pressure of the solar wind. This suggests an interaction where the current system associated with the enhanced magnetic field region flows along the ionopause and is closed by currents in the shocked solar wind plasma, where the J times B forces slow down the plasma approaching the stagnation region and accelerate the plasma flowing away from it. Thus, the lack of magnetic constraint in the ionosphere would allow ionospheric plasma to flow freely from the day to the night side, and this flow could probably maintain the nighttime ionosphere.

Johnson, F. S.↗

Computational procedure for evaluation of space shuttle TPS requirements

The rudiments of a computational procedure are presented for predicting heat transfer rates to the windward pitchplane of a shuttle vehicle under conditions of nonequilibrium flow. The procedure involves computations in three regions of the flow field, namely, the stagnation region, inviscid flow region, and boundary layer region. The thermochemical state in the inviscid flow was calculated with the aid of correlations developed from shadowgraphs of shuttle configurations. The flow in the boundary layer and stagnation regions was computed with a nonequilibrium viscous layer code. For boundary layers, the outer edge thermochemical state was determined by matching the mass flow in the boundary layer with the mass flow represented by each inviscid streamline. Typical solutions are presented to show the effects of surface pressure, catalycity, and homogeneous chemical reactions on flow field variables and surface heat transfer rates.

Tong, H.↗

Ablation of carbonaceous materials in a hydrogen-helium arc-jet flow

The stagnation-point ablation rates of a graphite, a carbon-carbon composite, and four carbon-phenolic materials are measured in an arc-jet wind tunnel with a 50% hydrogen-50% helium mixture as the test gas. Flow environments are determined through measurements of static and impact pressures, heat-transfer rates to a calorimeter, and radiation spectra, and through numerical calculation of the flow through the wind tunnel, spectra, and heat-transfer rates. The environments so determined are: impact pressure approx. 3 atm, Mach number approx. 2.1, convective heat-transfer rate approx. 14 kw/sq cm, and radiative heat-transfer rate approx. 7 kw/sq cm in the absence of ablation. Ablation rates are determined from the measured rates of mass loss and recession of the ablation specimens. Compared with the predicted ablation rates obtained by running RASLE and CMA codes, the measured rates are higher by about 15% for all tested materials.

Park, C.↗

Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps

This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.

Goekcen, Tahir↗

Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps

This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.

CFD↗