Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Method for simulating dose reduction in digital mammography using the Anscombe transformation

Purpose: This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. Methods: The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtained by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. Results: The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. Conclusions: A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe transformation. NNPS, PS, and local noise metrics confirm that this method is capable of precisely simulating various dose reductions.

60 APPLIED LIFE SCIENCES↗

Applicability of Loads Estimation Techniques Using Sparse Acceleration Sensor Data to Spacecraft Structural Health Monitoring

The use of structural health monitoring systems on spacecraft structures can play a crucial role in ensuring the safety, reliability, and longevity of the structure by gathering and analyzing onboard sensor data. Of specific importance is monitoring for excessive loading at critical interfaces as any off-nominal structural excitations experienced by spacecraft structures can cause early unpredicted high structural life consumption or damage. The availability and cost of flight-certified sensors along with the size of spacecraft structures and allowable payload mass drives the need for a method to estimate loads using sparsely-located sensors. Numerous approaches such as physics-based, statistical learning, and physics-enhanced statistical learning algorithms have gained popularity among structural prognostics applications. However, developing noise-robust prediction models to assess loads and structural life predictions from a sparse multi-sensor data acquisition system can be a challenging task. This paper discusses the evaluation of physics-based versus machine-learning algorithms for predicting loads and structural life at mission critical locations on the spacecraft structure using a finite element loads analysis with the application of simulated noise and noise reduction techniques. To estimate the loads from accelerations, the physics-based algorithm leverages a loads transformation matrix from a Craig-Bampton reduced finite element model. A System Equivalent Reduction Expansion Process (SEREP) and a pseudo-inverse approach are considered to expand from the onboard sensor degrees of freedom to the Craig-Bampton model degrees of freedom. The machine learning algorithm provides a data driven solution/mapping of the sensor accelerations to the loads at the mission critical locations using a high dimensionality analysis. Although these strategies produce comparable loads prediction without noise, the limitations of these strategies with incorporating simulated noise and noise reduction techniques with low signal to noise ratio signals are evaluated. The study demonstrates the immense potential of statistical learning algorithms for sparse structural prognostic models and enhancing signal denoising techniques. These findings also highlight the need for noise-resilient prognostic models and low-noise data acquisition systems onboard spacecraft structures.

Spacecraft Structural Health Monitoring↗

Video-signal improvement using comb filtering techniques.

Significant improvement in the signal-to-noise performance of television signals has been obtained through the application of comb filtering techniques. This improvement is achieved by removing the inherent redundancy in the television signal through linear prediction and by utilizing the unique noise-rejection characteristics of the receiver comb filter. Theoretical and experimental results describe the signal-to-noise ratio and picture-quality improvement obtained through the use of baseband comb filters and the implementation of a comb network as the loop filter in a phase-lock-loop demodulator. Attention is given to the fact that noise becomes correlated when processed by the receiver comb filter.

Arndt, G. D.↗

Theoretical detection threshold of the proton-acoustic range verification technique

Purpose: Range verification in proton therapy using the proton-acoustic signal induced in the Bragg peak was investigated for typical clinical scenarios. The signal generation and detection processes were simulated in order to determine the signal-to-noise limits. Methods: An analytical model was used to calculate the dose distribution and local pressure rise (per proton) for beams of different energy (100 and 160 MeV) and spot widths (1, 5, and 10 mm) in a water phantom. In this method, the acoustic waves propagating from the Bragg peak were generated by the general 3D pressure wave equation implemented using a finite element method. Various beam pulse widths (0.1–10 μs) were simulated by convolving the acoustic waves with Gaussian kernels. A realistic PZT ultrasound transducer (5 cm diameter) was simulated with a Butterworth bandpass filter with consideration of random noise based on a model of thermal noise in the transducer. The signal-to-noise ratio on a per-proton basis was calculated, determining the minimum number of protons required to generate a detectable pulse. The maximum spatial resolution of the proton-acoustic imaging modality was also estimated from the signal spectrum. Results: The calculated noise in the transducer was 12–28 mPa, depending on the transducer central frequency (70–380 kHz). The minimum number of protons detectable by the technique was on the order of 3–30 × 10{sup 6} per pulse, with 30–800 mGy dose per pulse at the Bragg peak. Wider pulses produced signal with lower acoustic frequencies, with 10 μs pulses producing signals with frequency less than 100 kHz. Conclusions: The proton-acoustic process was simulated using a realistic model and the minimal detection limit was established for proton-acoustic range validation. These limits correspond to a best case scenario with a single large detector with no losses and detector thermal noise as the sensitivity limiting factor. Our study indicated practical proton-acoustic range verification may be feasible with approximately 5 × 10{sup 6} protons/pulse and beam current.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation of core noise obtained by three signal coherence techniques

The prediction of frequency content and noise levels of turbofan engine core noise is reexamined as a result of recent test data and a new diagnostic technique. The diagnostic technique, utilizing a three-signal coherence method, is used to obtain core noise spectra for several engines. Similarities and differences of the spectra are discussed. Finally, the three-signal coherence data are correlated, leading to an improved core noise prediction procedure.

Vonglahn, U.↗

Impact of tool design on defect detection sensitivity in extreme ultraviolet actinic blank inspection

Here, we discuss the impact of various tool design perspectives on defect detection sensitivity for dark-field-based extreme ultraviolet (EUV) actinic blank inspection. We consider the impact of pixel size, EUV source type, and photon collection efficiency on critical defect signal-to-noise ratio (SNR) performance. The results show that as the pixel size approaches the target defect image size, defect SNR increases, and that pixel size also determines the dominant noise source in the inspection system. Moreover, the choice of the EUV source affects the optimal numerical aperture (NA) and illumination settings. For plasma-discharged sources, more photons provided by larger partial coherent illumination can improve the defect SNR, while coherent illumination is needed to get a higher defect SNR for synchrotron-based source. In the end, we show that simply increasing the photon collection efficiency by using high-NA optics or increasing the source power cannot always improve the defect SNR. In a speckle-noise dominated situation, larger outer NA includes more noise than defect signal, thus resulting in a lower SNR. The impact of source power also saturates at a certain level as the system becomes speckle-noise limited compared to photon-noise limited.

42 ENGINEERING↗

Investigation of the Window Variance Noise Component of Multicomponent Signals

Signal partitioning or signal segmentation allows to perform data classification, prediction of signals’ behavior, and profound interpretation of obtained data. In accordance with the signal model some distribution characteristics of the window variance noise component are investigated. It was shown that when all true underlying signal components remain unchanged, the window variance noise component is gamma distributed. Applying window variance to multicomponent signal (i.e., pharmacokinetic curve), it was shown that the window variance allows to split visually the signal record into phases due to prevalent processes.

97 MATHEMATICS AND COMPUTING↗

A general framework and review of scatter correction methods in x-ray cone-beam computerized tomography. Part 1: Scatter compensation approaches

Since scattered radiation in cone-beam volume CT implies severe degradation of CT images by quantification errors, artifacts, and noise increase, scatter suppression is one of the main issues related to image quality in CBCT imaging. The aim of this review is to structurize the variety of scatter suppression methods, to analyze the common structure, and to develop a general framework for scatter correction procedures. In general, scatter suppression combines hardware techniques of scatter rejection and software methods of scatter correction. The authors emphasize that scatter correction procedures consist of the main components scatter estimation (by measurement or mathematical modeling) and scatter compensation (deterministic or statistical methods). The framework comprises most scatter correction approaches and its validity also goes beyond transmission CT. Before the advent of cone-beam CT, a lot of papers on scatter correction approaches in x-ray radiography, mammography, emission tomography, and in Megavolt CT had been published. The opportunity to avail from research in those other fields of medical imaging has not yet been sufficiently exploited. Therefore additional references are included when ever it seems pertinent. Scatter estimation and scatter compensation are typically intertwined in iterative procedures. It makes sense to recognize iterative approaches in the light of the concept of self-consistency. The importance of incorporating scatter compensation approaches into a statistical framework for noise minimization has to be underscored. Signal and noise propagation analysis is presented. A main result is the preservation of differential-signal-to-noise-ratio (dSNR) in CT projection data by ideal scatter correction. The objective of scatter compensation methods is the restoration of quantitative accuracy and a balance between low-contrast restoration and noise reduction. In a synopsis section, the different deterministic and statistical methods are discussed with respect to their properties and applications. The current paper is focused on scatter compensation algorithms. The multitude of scatter estimation models will be dealt with in a separate paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Growing Signals from the Noise: Challenging Nuclei in Materials DNP

Here, the polarization of nuclear spins by dynamic nuclear polarization (DNP) has redefined the sensitivity limits of solid–state (SS) NMR spectroscopy. Materials science has been arguably one of the key beneficiaries of the recent remarkable advances of the technique, which included low–temperature magic angle spinning (MAS), modern gyrotrons, and biradical agents for polarization transfer via the cross–effect. In many classes of materials, DNP offers the capability of selectively sensitizing progressively smaller surface and interfacial regions of materials and eliciting responses from previously undetectable nuclei, with no detrimental effect on resolution. We review the most recent applications of DNP–enhanced SSNMR to materials, focusing specifically on measurements that pose insurmountable challenges to conventional SSNMR, including the detection of 15 N, 17 O, 25 Mg, 35 Cl, 43 Ca, 79 Br, 89 Y, 119 Sn, and 195 Pt by one–dimensional MAS methods, ultrawideline NMR, as well as two–dimensional homo– and heteronuclear correlation spectroscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative acetylene measurements in laminar and turbulent flames using 1D Raman/Rayleigh scattering

Our research presents the extension of the established detection of seven major species in 1D Raman/Rayleigh measurements to incorporate acetylene (C 2 H 2 ) as an eighth species. Acetylene is an important soot precursor which is generated in hydrocarbon flames as an intermediate species following decomposition. It occurs over a broad temperature range in flames and has been identified as a potentially detectable species in 1D Raman/Rayleigh measurements. In this paper, we discuss the Raman spectral signature of acetylene, its temperature dependence, calibration procedures, and the interference with other Raman-active species, C 2 and broadband interferences, all of which are essential to quantify for accurate data processing. In this regard, Raman measurements in laminar and turbulent dimethyl ether flames were acquired. The data are spectrally analyzed and low-temperature calibrations of the Raman response are combined with an extrapolation model for high temperatures in order to place the acetylene signals on an absolute scale. Single-shot and conditional-mean values are presented as a function of mixture fraction for a laminar partially-premixed DME/air flame. Measurements from the laminar flame are compared to a 1D laminar flame calculation to assess the accuracy of the calibration and analysis procedures. Furthermore, detection limits, signal-to-noise, and signal-to-interference ratio of the C 2 H 2 measurement are discussed, and single-shot measurements of acetylene in a turbulent DME/air jet flame are demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Å-Indentation for non-destructive elastic moduli measurements of supported ultra-hard ultra-thin films and nanostructures

During conventional nanoindentation measurements, the indentation depths are usually larger than 1–10 nm, which hinders the ability to study ultra-thin films (<10 nm) and supported atomically thin two-dimensional (2D) materials. Here, we discuss the development of modulated Å-indentation to achieve sub-Å indentations depths during force-indentation measurements while also imaging materials with nanoscale resolution. Modulated nanoindentation (MoNI) was originally invented to measure the radial elasticity of multi-walled nanotubes. Now, by using extremely small amplitude oscillations (<<1 Å) at high frequency, and stiff cantilevers, we show how modulated nano/Å-indentation (MoNI/ÅI) enables non-destructive measurements of the contact stiffness and indentation modulus of ultra-thin ultra-stiff films, including CVD diamond films (~1000 GPa stiffness), as well as the transverse modulus of 2D materials. Our analysis demonstrates that in presence of a standard laboratory noise floor, the signal to noise ratio of MoNI/ÅI implemented with a commercial atomic force microscope (AFM) is such that a dynamic range of 80 dB –– achievable with commercial Lock-in amplifiers –– is sufficient to observe superior indentation curves, having indentation depths as small as 0.3 Å, resolution in indentation <0.05 Å, and in normal load <0.5 nN. Being implemented on a standard AFM, this method has the potential for a broad applicability.

36 MATERIALS SCIENCE↗

Experimental considerations and applications for time-resolved impedance on silicon-anode battery systems

Dynamic electrochemical impedance spectroscopy (dEIS) utilizes a superimposed multi-sinusoidal waveform and enables temporally resolved investigations on various electrochemical processes; however, the signal-to-noise ratio must be maximized while retaining linearity and stationarity within the system. In the present work, we probe the impact of the waveform’s total amplitude as well as the waveform and phase profiles. The equal amplitude multi-sinusoidal waveform with 35 mV total amplitude (<1 mV per frequency) and random phase profile exhibits the lowest impedance noise. This input signal is sufficient in avoiding the high frequency signal attenuation from the potentiostat’s low-pass filter. Additionally, we demonstrate the optimized dEIS waveform’s utility in investigating surface passivation within thin-film and composite silicon (Si) anodes. Within a two-electrode Si-lithium metal coin cell, the charge transfer resistance (RCT) associated with alloying kinetics dominates the overall impedance. RCT increases with state of charge indicating a kinetic bottleneck at higher lithiation states. To explore this further, we utilize a three-electrode Si-LiNi0.8Mn0.1Co0.1O2 pouch cell to deconvolute the Si impedance contributions. The evolution of the solid electrolyte interphase (SEI) and charge transfer resistances correlate to specific Li–Si alloy phases. We attribute this to the influence of Si particle volume expansion on SEI instabilities and a kinetic bottleneck at higher lithiation states.

Lam, Steven [ORNL]↗

X-rays only when you want them: Optimized pump–probe experiments using pseudo-single-bunch operation

Laser pump–X-ray probe experiments require control over the X-ray pulse pattern and timing. Here, the first use of pseudo-single-bunch mode at the Advanced Light Source in picosecond time-resolved X-ray absorption experiments on solutions and solids is reported. In this mode the X-ray repetition rate is fully adjustable from single shot to 500 kHz, allowing it to be matched to typical laser excitation pulse rates. Suppressing undesired X-ray pulses considerably reduces detector noise and improves signal to noise in time-resolved experiments. In addition, dose-induced sample damage is considerably reduced, easing experimental setup and allowing the investigation of less robust samples. Single-shot X-ray exposures of a streak camera detector using a conventional non-gated charge-coupled device (CCD) camera are also demonstrated.

43 PARTICLE ACCELERATORS↗

WE-H-207A-06: Hypoxia Quantification in Static PET Images: The Signal in the Noise

Purpose: Quantification of hypoxia from PET images is of considerable clinical interest. In the absence of dynamic PET imaging the hypoxic fraction (HF) of a tumor has to be estimated from voxel values of activity concentration of a radioactive hypoxia tracer. This work is part of an effort to standardize quantification of tumor hypoxic fraction from PET images. Methods: A simple hypoxia imaging model in the tumor was developed. The distribution of the tracer activity was described as the sum of two different probability distributions, one for the normoxic (and necrotic), the other for the hypoxic voxels. The widths of the distributions arise due to variability of the transport, tumor tissue inhomogeneity, tracer binding kinetics, and due to PET image noise. Quantification of HF was performed for various levels of variability using two different methodologies: a) classification thresholds between normoxic and hypoxic voxels based on a non-hypoxic surrogate (muscle), and b) estimation of the (posterior) probability distributions based on maximizing likelihood optimization that does not require a surrogate. Data from the hypoxia imaging model and from 27 cervical cancer patients enrolled in a FAZA PET study were analyzed. Results: In the model, where the true value of HF is known, thresholds usually underestimate the value for large variability. For the patients, a significant uncertainty of the HF values (an average intra-patient range of 17%) was caused by spatial non-uniformity of image noise which is a hallmark of all PET images. Maximum likelihood estimation (MLE) is able to directly optimize for the weights of both distributions, however, may suffer from poor optimization convergence. For some patients, MLE-based HF values showed significant differences to threshold-based HF-values. Conclusion: HF-values depend critically on the magnitude of the different sources of tracer uptake variability. A measure of confidence should also be reported.

60 APPLIED LIFE SCIENCES↗

High-efficiency high-energy Ka source for the critically-required maximum illumination of x-ray optics on Z using Z-petawatt-driven laser-breakout-afterburner accelerated ultrarelativistic electrons LDRD .

Under the auspices of the Science of Extreme Environments LDRD program, a <2 year theoretical- and computational-physics study was performed (LDRD Project 130805) by Guy R Bennett (formally in Center-01600) and Adam B. Sefkow (Center-01600): To investigate novel target designs by which a short-pulse, PW-class beam could create a brighter K{alpha} x-ray source than by simple, direct-laser-irradiation of a flat foil; Direct-Foil-Irradiation (DFI). The computational studies - which are still ongoing at this writing - were performed primarily on the RedStorm supercomputer at Sandia National Laboratories Albuquerque site. The motivation for a higher efficiency K{alpha} emitter was very clear: as the backlighter flux for any x-ray imaging technique on the Z accelerator increases, the signal-to-noise and signal-to-background ratios improve. This ultimately allows the imaging system to reach its full quantitative potential as a diagnostic. Depending on the particular application/experiment this would imply, for example, that the system would have reached its full design spatial resolution and thus the capability to see features that might otherwise be indiscernible with a traditional DFI-like x-ray source. This LDRD began FY09 and ended FY10.

43 PARTICLE ACCELERATORS↗