Valveless Laser Processing
Los Alamos National Laboratory staff has developed a technique for testing inside hermetically sealed devices.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Los Alamos National Laboratory staff has developed a technique for testing inside hermetically sealed devices.
Explore the source record for details and available documents.
The energy-level alignment at metal/organic interfaces has traditionally been studied using ultraviolet photoelectron spectroscopy (UPS) in ultra-high vacuum (UHV). However, since most devices are fabricated in high vacuum (HV), these studies do not accurately reflect the interfaces in real devices. We demonstrate, using UPS measurements of samples prepared in HV and UHV and current-voltage measurements of devices prepared in HV, that the small amounts of residual gases that are adsorbed on the surface of clean Cu, Ag, and Au (i.e., the noble metals) in HV can significantly alter the energy-level alignment at metal/organic interfaces.
The Voyager spacecraft is subject to radiation from external natural space, from radioisotope thermoelectric generators and heater units, and from the internal environment where penetrating electrons generate surface ionization effects in semiconductor devices. Methods for radiation hardening and tests for radiation sensitivity are described. Results of characterization testing and sample screening of over 200 semiconductor devices in a radiation environment are summarized.
Multiple cases of attempted bioterrorism events using biotoxins have highlighted the urgent need for tools capable of rapid screening of suspect samples in the field (e.g., mailroom and public events). We present a portable microfluidic device capable of analyzing environmental (e.g., white powder), food (e.g., milk) and clinical (e.g., blood) samples for multiplexed detection of biotoxins. The device is rapid (<15-30 min sample-to-answer), sensitive (< 0.08 pg/mL detection limit for botulinum toxin), multiplexed (up to 64 parallel assays) and capable of analyzing small volume samples (< 20 μL total sample input). The immunoassay approach (SpinDx) is based on binding of toxins in a sample to antibody-laden capture particles followed by sedimentation of particles through a density-media in a microfluidic disk and quantification using a laser-induced fluorescence detector. A direct, blinded comparison with a gold standard ELISA revealed a 5-fold more sensitive detection limit for botulinum toxin while requiring 250-fold less sample volume and a 30 minute assay time with a near unity correlation. A key advantage of the technique is its compatibility with a variety of sample matrices with no additional sample preparation required. Ultrasensitive quantification has been demonstrated from direct analysis of multiple clinical, environmental and food samples, including white powder, whole blood, saliva, salad dressing, whole milk, peanut butter, half and half, honey, and canned meat. We believe that this device can met an urgent need in screening both potentially exposed people as well as suspicious samples in mail-rooms, airports, public sporting venues and emergency rooms. The general-purpose immunodiagnostics device can also find applications in screening of infectious and systemic diseases or serve as a lab device for conducting rapid immunoassays.
A radiation sensitive area detection device is disclosed which comprises a phosphor-containing film capable of receiving and storing an image formed by a pattern of incoming x rays, UV, or other radiation falling on the film. The device is capable of fluorescing in response to stimulation by a light source in a manner directly proportional to the stored radiation pattern. The device includes: (1) a light source capable of projecting light or other appropriate electromagnetic wave on the film so as to cause it to fluoresce; (2) a means to focus the fluoresced light coming from the phosphor-containing film after light stimulation; and (3) at least one charged coupled detector or other detecting element capable of receiving and digitizing the pattern of fluoresced light coming from the phosphor-containing film. The device will be able to generate superior x ray images of high resolution from a crystal or other sample and will be particularly advantageous in that instantaneous near-real-time images of rapidly deteriorating samples can be obtained. Furthermore, the device can be made compact and sturdy, thus capable of carrying out x ray or other radiation imaging under a variety of conditions, including those experienced in space.
Preparation of amorphous thin films in semiconductors and their transition to the crystalline phase may apply to switching devices. Surfaces of single crystal samples of bulk In2Se3 and thin films of InSe were treated using an excimer laser, and microscopic examination showed the treated portions of the surface had become amorphous. Film samples of InSe were laser-treated like the bulk samples. Examination of these treated flims showed shifts in the optical transmittance spectra as well as surface morphology changes.
High resolution X-ray microCT (computerized tomography) can be used to image a variety of objects, including temperature-sensitive materials. In cases where the sample must be chilled or frozen to maintain sample integrity, either the microCT machine itself must be placed in a refrigerated chamber, or a relatively expensive commercial cold stage must be purchased. We describe here the design and construction of a low-cost custom cold stage suitable for use in a microCT imaging system. Our device uses a boron nitride sample holder, two-stage Peltier cooler, fan-cooled heat sink, and electronic controller to maintain sample temperatures as low as −25 °C ± 0.2 °C for the duration of a tomography acquisition. The design does not require modification to the microCT machine, and is easily installed and removed. Our custom cold stage represents a cost-effective solution for refrigerating CT samples for imaging, and is especially useful for shared equipment or machines unsuitable for cold room use.
The increasing prevalence of counterfeit and incompatible refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) systems, including compromised equipment performance, safety hazards, and non-compliance. This article details the development of a novel, cost-effective, and portable detection device designed to accurately verify refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing feedback within a 2-minute duration. Laboratory validation demonstrated the device’s high accuracy (>95 % based on correct identification of compliant vs. non-compliant blends) in detecting unauthorized refrigerant blends. The projected cost of the product stands at ∼ $150, based on the retail pricing of individual components. Laboratory validation demonstrated the device’s high accuracy (>95 % for composition identification, 100 % rejection of tested counterfeit/incorrect blends) in detecting unauthorized refrigerant blends with a response time <2 min. The device correctly identified authentic R-454A/B/C blends and reliably rejected R-407F and closely related counterfeit mixtures. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks, enhances safety in HVAC&R operations, and mitigates the risks associated with counterfeit refrigerants.
Recent advances in sample preparation enable label-free MS-based proteome profiling of small numbers of mammalian cells. However, specific devices are often required to downscale sample processing volume from the standard 50-200 µL to sub-µL for effective nanoproteomics, which greatly impedes the implementation of current nanoproteomics methods by broad proteomics research community. Here we report a facile one-pot nanoproteomics method termed SOPs-MS (Surfactant-assisted One-Pot sample processing at the standard volume coupled with MS) for convenient proteome profiling of 50-1000 mammalian cells. Building upon our recent development of SOP-MS for label-free single-cell proteomics at low µL volume (Commun Bio 2021, 4, 265), we have systematically evaluated its processing volume at 10-200 µL using 100 human cells for robust reproducible nanoproteomic analysis. The processing volume of 50 µL which is in the range of volume for standard proteomics sample preparation, has been selected for easy sample handling with benchtop micropipette. Using the commonly accessible LC-MS platform, SOPs-MS allows for reliable label-free quantification of ~1200-2700 protein groups from 50-1000 MCF10A cells. When applied to small subpopulations of mouse colon crypt cells, SOPs-MS can reveal distinct protein signatures between any two subpopulation cells with identification of ~1500-2500 protein groups for each subpopulation. SOPs-MS may pave the way for routine deep proteome profiling of small numbers of cells as well as low-input samples.
Adaptive optics restore ideal imaging performance in complex samples by measuring and correcting optical aberrations but often require custom-built microscopes with carefully aligned wavefront sensing/shaping devices and can be susceptible to sample motion. Here we describe NeAT, a computational framework using neural fields for adaptive optics two-photon fluorescence microscopy. NeAT estimates wavefront aberration and recovers sample structure from a 3D image stack without requiring external datasets for training. Incorporating motion correction in learning and correcting conjugation errors commonly found in commercial microscopes, NeAT is designed for deployment in biological laboratories for in vivo imaging. We validate NeAT’s performance using a custom-built microscope with a wavefront sensor under varying signal-to-noise ratios, aberration and motion conditions. With a commercial microscope, we demonstrate real-time aberration correction for in vivo morphological and functional imaging in the living mouse brain, with NeAT improving the signal and accuracy of glutamate and calcium imaging of synapses and neurons.
The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity.Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the American Innovation and Manufacturing (AIM) Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.
The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity. Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the AIM Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.
A new fractionation device shows desirable features for exploratory screening and biomarker discovery. The constituent MSCs may be tailored for desired pore sizes and surface properties and for the sequestration and enrichment of extremely low abundant protein and peptides in desired ranges of the mass/charge spectrum. The MSCs are effective in yielding reproducible extracts from complex biological samples as small as 10 microliter in a time as short as 30 minutes. They are inexpensive to manufacture, and allow for scaled up production to attain the simultaneous processing of a large number of samples. The MSCs are multiplexed, label-free diagnostic tools with the potential of biological recognition moiety modification for enhanced specificity. The MSCs may store, protect and stabilize biological fluids, enabling the simplified and cost-effective collection and transportation of clinical samples. The MSC-based device may serve as a diagnostic tool to complement histopathology, imaging, and other conventional clinical techniques. The MSCs mediated identification of disease-specific protein signatures may help in the selection of personalized therapeutic combinations, in the real-time assessment of therapeutic efficacy and toxicity, and in the rational modulation of therapy based on the changes in the protein networks associated with the prognosis and the drug resistance of the disease.
The Environmental Sample Processor (ESP) is a device that allows for the underwater, autonomous application of DNA and protein probe array technologies as a means to remotely identify and quantify, in situ, marine microorganisms and substances they produce. Here, we added functionality to the ESP through the development and incorporation of a module capable of solid-phase nucleic acid extraction and quantitative PCR (qPCR). Samples collected by the instrument were homogenized in a chaotropic buffer compatible with direct detection of ribosomal RNA (rRNA) and nucleic acid purification. From a single sample, both an rRNA community profile and select gene abundances were ascertained. To illustrate this functionality, we focused on bacterioplankton commonly found along the central coast of California and that are known to vary in accordance with different oceanic conditions. DNA probe arrays targeting rRNA revealed the presence of 16S rRNA indicative of marine crenarchaea, SAR11 and marine cyanobacteria; in parallel, qPCR was used to detect 16S rRNA genes from the former two groups and the large subunit RuBisCo gene (rbcL) from Synecchococcus. The PCR-enabled ESP was deployed on a coastal mooring in Monterey Bay for 28 days during the spring-summer upwelling season. The distributions of the targeted bacterioplankon groups were as expected, with the exception of an increase in abundance of marine crenarchaea in anomalous nitrate-rich, low-salinity waters. The unexpected co-occurrence demonstrated the utility of the ESP in detecting novel events relative to previously described distributions of particular bacterioplankton groups. The ESP can easily be configured to detect and enumerate genes and gene products from a wide range of organisms. This study demonstrated for the first time that gene abundances could be assessed autonomously, underwater in near real-time and referenced against prevailing chemical, physical and bulk biological conditions.
Single phase ε-Mn4N thin and ultrathin films are grown on MgO(001) using molecular beam epitaxy. Reflection high-energy electron diffraction and outof-plane x-ray diffraction measurements are taken for each sample in order to determine the in- and out-of-plane strain for each sample. Vibrating sample magnetometry and superconducting quantum interference device measurements, which are performed on the thin and ultrathin films respectively, are used to plot the magnetization of each sample versus both in- and out-of-plane $\vec H$-fields and to determine the magnitude of perpendicular magnetic anisotropy in these films. Three significant components of perpendicular magnetic anisotropy are observed in these films and are attributed to sample strain (1 component) and shape (2 components). Among these components, the most significant component (0.8 to 4.9 $\frac{Merg}{cm^3}$) is identified as a second term of shape anisotropy, which possesses a negative linear relationship with sample thickness over the range from 9 nm to 310 nm. Atomic (magnetic) force microscopy measurements show the presence of a surface localized magnetic polarization (22% to 82%), which increases with decreasing thickness, when the net magnetization of the films is zero. The second term of shape anisotropy as well as the surface localized polarization, which each depend on sample thickness, are each regarded as a consequence of Ising domains overlapping out-of-plane in these films.
Purpose: To assess the accuracy of cytological sampling and forceps biopsy in obstructing biliary lesions and to identify factors predictive of success. Methods: Consecutive patients (n = 119) with suspected malignant inoperable obstructive jaundice treated with percutaneous transhepatic biliary drainage during 7 years were included (60 male; mean age 72.5 years). All patients underwent forceps biopsy plus cytological sampling by washing the forceps device in cytological solution. Patient history, procedural and pathological records, and clinical follow-up were reviewed. Statistical analysis included chi-square test and multivariate regression analysis. Results: Histological diagnosis after forceps biopsy was more successful than cytology: Sensitivity was 78 versus 61%, and negative predictive value was 30 versus 19%. Cytology results were never positive when the forceps biopsy was negative. The cytological sample was negative and forceps sample positive in 2 cases of cholangiocarcinoma, 16 cases of pancreatic carcinoma, and 1 case of benign disease. Diagnostic accuracy was predicted by low bilirubin (p < 0.001), aspartate transaminase (p < 0.05), and white cell count (p {<=} 0.05). Conclusions: This technique is safe and effective and is recommended for histological diagnosis during PTBD in patients with inoperable malignant biliary strictures. Diagnostic yield is greater when bilirubin levels are low and there is no sepsis; histological diagnosis by way of forceps biopsy renders cytological sampling unnecessary.
The project succeeded in producing crack-free Bismuth Telluride thermoelectric parts with density exceeding 98% through laser powder bed fusion (LPBF) additive manufacturing (AM). This greatly exceeded the highest previously reported density of 88% and is the highest among all semiconducting materials processed by LPBF. The additively manufactured material shows comparable Seebeck coefficient as conventional form and can be made into complex geometries with reduced material loss. On the other hand, measured properties are dramatically sensitive to the AM process parameters used, such that with identical composition, the Seebeck coefficient can be controllably tuned from +120 µV/K to -207 µV/K, which means the material switches between an n-type to a p-type semiconductor depending on processing. These changes are accompanied by significant differences in the as-processed microstructure due to rapid solidification. A machine learning protocol was developed and greatly reduced the experimental burden of the project, reducing the typical process optimization period of 2 years to 6 months. The project was fully successful in the objective of producing defect-free, complex geometry of bismuth-telluride parts through LPBF, but only partially successful in achieving performance goals. First, cost reduction of manufacturing, as measured by material waste, was successfully reduced by up to 70% compared to conventional manufacturing methods. This exceeded the proposed 30% reduction in materials waste needed to reach the 20% cost reduction goal of the project. On the other hand, the device performance, as measured by Seebeck coefficient, failed to reach the 40% improvement in efficiency. Rather, we observe comparable Seebeck coefficient between AM samples and conventionally processed counterparts. The device-level efficiency improvement does exceed 40% for complex geometry samples due to shape-induced increase in temperature gradients, but this was not the originally proposed metric. The machine learning approach developed in this project greatly accelerated the process optimization and can be adopted for fast development of AM processing parameters for other brittle and otherwise difficult-to-print materials. For the public, we deliver an efficient and widely adoptable process for incorporating waste-heat harvesting thermoelectric devices in both industrial and commercial heat exchangers. The geometric flexibility allows the capturing device to conform to the shape of the heat source to improve the system-level conversion efficiency. The technique can be deployed on any commercial LBPF systems with zero modifications, thus poses minimal adoption barrier for any manufacturer that already employed AM technology. Beyond bismuth-telluride, the machine-learning guided optimization protocol can be used in the future to reduce both the time and cost of process development for AM of other energy conversion and harvesting materials.