Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Repeater”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Quantifying Burst Repeatability for Godiva IV

The minimum resolvable relative change in the neutron source emission of Godiva IV between bursts, i.e., burst repeatability, was quantified using a combination of activation monitors and a resistance temperature detector (RTD). Measurements support changes in the neutron source emission between bursts can be determined with a precision of 2.7%. The measurements were performed during a series of twelve Godiva IV bursts and were a collaborative effort between Los Alamos National Laboratory, Sandia National Laboratories, and Pacific Northwest National Laboratory. Gold, iron, nickel, and sulfur activation monitors were positioned in a sample holder in the central cavity of Godiva IV for each burst. The RTD is part of the Godiva burst diagnostic system and is in a fixed location in the safety block of Godiva IV. It is used to determine the temperature rise of the burst, i.e., the difference between the maximum temperature recorded during the burst and the initial temperature prior to the burst. Differences in either the specific activity of the activation monitor reactions, or the temperature rise can be used to determine the relative change in the neutron source emission for separate bursts, but historic results have proven that each method is susceptible to various sources of biases which generally cannot be isolated using a single method. We address this issue by applying both measurement methods and analyzing the correlation between them. The results presented in this work will be used to support future experiments with Godiva IV at the National Criticality Experiments Research Center (NCERC).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Data Analyst - A Device for Continuous Repeating Real-Time Assay of HPGe, CZT, or Scintillation Gamma Spectra - 18574

There are many situations where a continuous repeating series of quantitative gamma spectral assays is desirable. These include measurements of fluid going through a pipe, of items on a conveyor passing under a detector, a detector aimed at the ground on a moving platform, or a detector in free air as a plume of radioactivity drifts by. While Canberra and many others have built and deployed many of these devices, they have all been custom built for that particular application, and rather expensive. The Data Analyst [DA] is a general purpose device that is designed to fulfill many of these applications without modification, but can be fairly-easily modified if needed. The DA is a small [12 x 18 x 5 cm], low-power [3 W] box that accepts the input from external MCAs, controls the acquisition cycle, analyzes the results, and transmits them to the outside world when needed. The detector-MCAs supported are HPGe with Lynx MCA, NaI or CeBr or LaBr with Osprey MCA, and CZT or CsI with internal MCAs. The DA internal software used for analysis is the full standard Genie analysis software, which is very widely used and well accepted in the industry. This allows exported spectral files to be reviewed and confirmed by Experts, and reanalyzed if needed. The DA hardware is totally autonomous. As soon as power is applied, it starts the pre-programmed sequences of acquisition and analysis. Multiple analysis sequences [called Workflows] can be in operation simultaneously, e.g. with different count times and different nuclide libraries. Only the detector with MCA, and the DA are required in the field. A PC can be connected to the DA locally or remotely via WiFi, USB, or Ethernet. The PC is needed to setup the DA, and to readout the results. The DA also supports [with application-specific programming] external Inputs/Outputs either for recording with the analysis results or for use in the computation of the result, e.g. temperature, flow rate, pressure, ... ]. The DA also has an internal GPS receiver with external antenna. Applications of the DA that are discussed include stack gas effluent activity where a portion of the effluent stream was extracted to flow through a shield with a HPGe detector and Lynx MCA, and measurement of reactor coolant activity where a shielded CZT detector and MCA were aimed at various sections of reactor primary coolant during a maintenance outage. Potential other applications are also described. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of programmable logic in a rapid, automated, and repeatable fashion for safety-related applications - 385

Digital safety platform considerations for power plant modernization or new build efforts involve a burdensome task of implementing a large number of software-based functions onto a designated platform to match the plant's architecture. This problem is not unique to any particular safety-related platform solution, but is prevalent across the landscape of current Qualified and Licensed Safety-related Instrumentation and Control (I and C) Solutions. As an example when implementing a RG 1.97 compliant Post Accident Monitoring System (PAMS) solution with the Lockheed Martin Nuclear Protection and Control (NuPAC) safety platform, 72 unique software loads are needed to configure the Qualified Display System (QDS). Large scale development and customization efforts to upgrade existing plant functions or systems require the licensee to assume the cost and technical risk necessary to undergo a digital based upgrade. Often the cost, schedule, and technical risk outweighed the benefit of modernization efforts due to the unknown hurdles and past projects that overran cost and schedule projections. Lockheed Martin's Engineering Production Suite (EPS) minimizes the licensee risk and expense associated with modernization efforts through a developer's toolkit for rapid, automated, and repeatable development of Programmable Logic used to implement plant functions and architectures for use on the Lockheed Martin NuPAC platform. This paper describes a use case where by EPS can create system level representations, simulate system functions, partition logic designs to accommodate hardware constraints through logic partitioning, automate the assembly of Application Specific Programmable Logic (ASPL), generate system test cases, program the NuPAC hardware, and perform testing throughout the design workflow. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reliable and Repeatable Characterization of Optical Streak Cameras

Optical streak cameras are used as primary diagnostics for a wide range of physics and laser performance verification experiments at the National Ignition Facility (NIF). To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electronic components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases the characterization data is used to “correct” data images, to remove some of the nonlinearities. In order to obtain these camera characterizations, a specific data set is collected where the response to specific known inputs is recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, temporal resolution, etc., from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reliable and Repeatable Characterication of Optical Streak Cameras

Optical streak cameras are used as primary diagnostics for a wide range of physics and laser experiments at facilities such as the National Ignition Facility (NIF). To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electrical components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases, the characterization data are applied to the raw data images to correct for the nonlinearities. In order to characterize an optical streak camera, a specific set of data is collected, where the response to defined inputs are recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, and temporal resolution from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information.

42 ENGINEERING↗

Cytogenetic Analysis of Populus trichocarpa - Ribosomal DNA, Telomere Repeat Sequence, and Marker-selected BACs

The 18S-28S rDNA and 5S rDNA loci in Populus trichocarpa were localized using fluorescent in situ hybridization (FISH). Two 18S-28S rDNA sites and one 5S rDNA site were identified and located at the ends of 3 different chromosomes. FISH signals from the Arabidopsis -type telomere repeat sequence were observed at the distal ends of each chromosome. Six BAC clones selected from 2 linkage groups based on genome sequence assembly (LG-I and LG-VI) were localized on 2 chromosomes, as expected. BACs from LG-I hybridized to the longest chromosome in the complement. All BAC positions were found to be concordant with sequence assembly positions. BAC-FISH will be useful for delineating each of the Populus trichocarpa chromosomes and improving the sequence assembly of this model angiosperm tree species.

59 BASIC BIOLOGICAL SCIENCES↗

T-Toxin Virulence Genes: Unconnected Dots in a Sea of Repeats

In 1970 a corn disease epidemic ravaged fields in the United States to great economic loss. The outbreak was caused by a never-before seen, supervirulent strain of the fungal pathogen Cochliobolus heterostrophus. This was a plant disease epidemic, however, the current COVID-19 pandemic of humans is a stark reminder that novel, highly virulent, pathogens evolve with devastating consequences, no matter what the host-animal, plant, or other organism.

59 BASIC BIOLOGICAL SCIENCES↗

Chromosome-Specific DNA Repeats: Rapid Identification in Silico and Validation Using Fluorescence in Situ Hybridization

Chromosome enumeration in interphase and metaphase cells using fluorescence in situ hybridization (FISH) is an established procedure for the rapid and accurate cytogenetic analysis of cell nuclei and polar bodies, the unambiguous gender determination, as well as the definition of tumor-specific signatures. Present bottlenecks in the procedure are a limited number of commercial, non-isotopically labeled probes that can be combined in multiplex FISH assays and the relatively high price and effort to develop additional probes. We describe a streamlined approach for rapid probe definition, synthesis and validation, which is based on the analysis of publicly available DNA sequence information, also known as “database mining”. Examples of probe preparation for the human gonosomes and chromosome 16 as a selected autosome outline the probe selection strategy, define a timeline for expedited probe production and compare this novel selection strategy to more conventional probe cloning protocols.

59 BASIC BIOLOGICAL SCIENCES↗

LOW-ALTITUDE REPEATER SATELLITES

The new perspective that is forced upon us by the Space Age is oddly evident in the title of this paper. The key adjective is "low-altitude," evoking, perhaps, a picture of objects flying just above the rooftops. In the strange new realm of space, however, we are using a different order of measurement. The low-altitude satellites that I shall discuss will be moving in orbits anywhere from a few hundred to more than ten thousand miles above the Earth.

Low altitude↗

An L-band SAR for repeat pass deformation measurements on a UAV platform

We are proposing to develop a miniaturized polarimetric L-band synthetic aperture radar (SAR) for repeatpass differential interferometric measurements of deformation for rapidly deforming surfaces of geophysical interest such as volcanoes or earthquakes that is to be flown on a unmanned aerial vehicle (UAV or minimally piloted vehicle (MPV).

repeat pass interferometry↗