Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reliability assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

On the Sensitivity of Piezoceramics and Piezopolymers in Structural Integrity Monitoring of Large Trusses

An analytical assessment has been made of the reliability of using integrated microactuators and sensors in the form of piezoceramics and piezopolymers as joint integrity monitors in trussed systems. The concept is first implemented for a simple structure which consists of two truss members with a 45 deg lift angle joined at the apex. A piezoceramic patch (or piezopolymer film) bonded on the surface of one of the members at a location near the joint is used as a collocated actuator/sensor. The overall structural dynamic response under an excitation was modeled by finite element method. Different degrees of nodal constraints at the joints representing various degrees of joint integrity are employed. The resulting dynamic response showed distinct responses for varying joint stiffnesses. Parallel experimental work on a truss model using a multichannel data acquisition system and a digital signal analyzer confirms the results from analysis. We further studied the sensitivity of the micro-sensors to the behavior of joints of large arch truss structure. Results obtained for large trusses with many degrees of freedom indicate optimum locations of sensors for which the dynamic response signatures are distinct and distinguishable for relatively small changes in joint integrity and/or structural geometry. Computations based on finite element modeling show that locating the single actuator/sensor at the joint corresponding to the first loss of static stability appear optimal. Hence, static stability analysis of complex trusses can give us a good indication of the optimum placement of sensors for maximum response. This observation is important if few distributed sensors and actuators are available for placement in constructed facilities made from large trusses with many degrees of freedom. As an extension of this work a dynamic response signature identification technique to monitor in-service degradation of joints is under development for application to the monitoring of the integrity of adhesive joints in composite structures.

Abatan, A. O.↗

Five-Segment Reusable Solid Rocket Booster Upgrade

The Five Segment Reusable Solid Rocket Booster (RSRB) feasibility status is presented in viewgraph form. The Five Segment Booster (FSB) objective is to provide a low cost, low risk approach to increase reliability and safety of the Shuttle system. Topics include: booster upgrade requirements; design summary; reliability issues; booster trajectories; launch site assessment; and enhanced abort modes.

Sauvageau, Don↗

Self-Motion Perception: Assessment by Real-Time Computer Generated Animations

Our overall goal is to develop materials and procedures for assessing vestibular contributions to spatial cognition. The specific objective of the research described in this paper is to evaluate computer-generated animations as potential tools for studying self-orientation and self-motion perception. Specific questions addressed in this study included the following. First, does a non- verbal perceptual reporting procedure using real-time animations improve assessment of spatial orientation? Are reports reliable? Second, do reports confirm expectations based on stimuli to vestibular apparatus? Third, can reliable reports be obtained when self-motion description vocabulary training is omitted?

Parker, Donald E.↗

Acceptance Testing of the Vapor Phase Catalytic Ammonia Removal Engineering Development Unit

This paper describes the results of acceptance testing of the Vapor Phase Catalytic Ammonia Removal (VPCAR) technology. The VPCAR technology is currently being developed by NASA as a Mars transit vehicle water recycling system. NASA has recently completed a grant to develop a next generation VPCAR system. This grant was peer reviewed and funded through the Advanced Life Support (ALS) National Research Announcement (NRA). The grant funded a contract with Water Reuse Technology Inc. to construct an engineering development unit. This contract concluded with the shipment of the final deliverable to NASA on 8/31/03. The objective of the acceptance testing was to characterize the performance of this new system. This paper presents the results of mass power, and volume measurements for the delivered system. In addition, product water purity analysis for a Mars transit mission and a planetary base wastewater ersatz are provided. Acoustic noise levels, interface specifications and system reliability results are also discussed. An assessment of the readiness of the technology for human testing and recommendations for future improvements are provided.

Flynn, Michael↗

Progress in High Power Density SOFC Material Development for Aerospace Applications

Solid oxide fuel cell (SOFC) systems for aircraft applications require order of magnitude increase in specific power density and long life under aircraft operating conditions. Advanced SOFC materials and fabrication processes are being developed at NASA GRC to increase specific power density and durability of SOFC cell and stack. Initial research efforts for increasing specific power density are directed toward increasing the operating temperature for the SOFC system and reducing the weight of the stack. While significant research is underway to develop anode supported SOFC system operating at temperatures in the range of 650 - 850 C for ground power generation applications, such temperatures may not yield the power densities required for aircraft applications. For electrode-supported cells, SOFC stacks with power densities greater than 1.0 W/sq cm are favorable at temperatures in excess of 900 C. The performance of various commercial and developmental anode supported cells is currently being evaluated in the temperature range of 900 to 1000 C to assess the performance gains and materials reliability. The results from these studies will be presented. Since metal interconnects developed for lower temperature operation are not practical at these high temperatures, advanced perovskite based ceramic interconnects with high electronic conductivity and lower sintering temperatures are being developed. Another option for increasing specific power density of SOFC stacks is to decrease the stack weight. Since the interconnect contributes to a significant portion of the stack weight, considerable weight benefits can be derived by decreasing its thickness. Eliminating the gas channels in the interconnect by engineering the pore structure in both anode and cathode can offer significant reduction in thickness of the ceramic interconnect material. New solid oxide fuel cells are being developed with porous engineered electrode supported structures with a 10 - 20 micron thin electrolyte. The performance data for advanced SOFC cells with engineered porosity in both electrodes will be presented.

Cable, Thomas L.↗

Reliability of Radioisotope Stirling Convertor Linear Alternator

Onboard radioisotope power systems being developed and planned for NASA s deep-space missions would require reliable design lifetimes of up to 14 years. Critical components and materials of Stirling convertors have been undergoing extensive testing and evaluation in support of a reliable performance for the specified life span. Of significant importance to the successful development of the Stirling convertor is the design of a lightweight and highly efficient linear alternator. Alternator performance could vary due to small deviations in the permanent magnet properties, operating temperature, and component geometries. Durability prediction and reliability of the alternator may be affected by these deviations from nominal design conditions. Therefore, it is important to evaluate the effect of these uncertainties in predicting the reliability of the linear alternator performance. This paper presents a study in which a reliability-based methodology is used to assess alternator performance. The response surface characterizing the induced open-circuit voltage performance is constructed using 3-D finite element magnetic analysis. Fast probability integration method is used to determine the probability of the desired performance and its sensitivity to the alternator design parameters.

Shah, Ashwin↗

IV and V Issues in Achieving High Reliability and Safety in Critical Control System Software

Risk analysis and integrated verification and validation are two important elements in a plan for ensuring the safety of critical software systems. We describe an approach we are currently developing for integrating risk analysis, and metrics analysis, and propose a fault predictor that would integrate the results of these activities. Practical difficulties associated with our approach are also discussed, as are limitations of the proposed predictor. We conclude with a discussion of what as been learned to date, and with suggestions for future work.

validation software reliability software risk asse↗

Cytogenetic Biodosimetry Using the Blood Lymphocytes of Astronauts

Cytogenetic analysis of blood lymphocytes remains the most sensitive and reliable method available for in vivo assessment of the biological effects of exposure to radiation and provides the most informative measurement of radiation induced health risks. To date chromosome damage has been assessed in lymphocytes from more than 30 astronauts before and after they participated in long-duration space missions of three months or more on board the International Space Station. For all individuals, the frequency of chromosome damage measured within a month of return from space was higher than their prefight yield and biodosimetry estimates lie within the range expected from physical dosimetry. Biodosimetry data provides a direct measurement of space radiation damage, which takes into account individual radiosensitivity in the presence of confounding factors such as microgravity and other stress conditions. In contrast to physical measurements, which are external to body and require multiple devices to detect all radiation types all of which have poor sensitivity to neutrons, biodosimetry is internal and includes the effects of shielding provided by the body itself plus chromosome damage shows excellent sensitivity to protons, heavy ions, and neutrons. In addition, chromosome damage is reflective of cancer risk and biodosimetry values can therefore be used to validate and develop risk assessment models that can be used to characterize excess health risk incurred by crewmembers. A review of astronaut biodosimetry data will be presented along with recent findings on the persistence of space radiation induced chromosome damage and the cytogenetic effects of repeat long duration missions

George, Kerry↗

Estimating the Reliability of Electronic Parts in High Radiation Fields

Radiation effects on materials and electronic parts constrain the lifetime of flight systems visiting Europa. Understanding mission lifetime limits is critical to the design and planning of such a mission. Therefore, the operational aspects of radiation dose are a mission success issue. To predict and manage mission lifetime in a high radiation environment, system engineers need capable tools to trade radiation design choices against system design and reliability, and science achievements. Conventional tools and approaches provided past missions with conservative designs without the ability to predict their lifetime beyond the baseline mission.This paper describes a more systematic approach to understanding spacecraft design margin, allowing better prediction of spacecraft lifetime. This is possible because of newly available electronic parts radiation effects statistics and an enhanced spacecraft system reliability methodology. This new approach can be used in conjunction with traditional approaches for mission design. This paper describes the fundamentals of the new methodology.

radiation↗

Modeling the X-Ray Process, and X-Ray Flaw Size Parameter for POD Studies

Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

Khoshti, Ajay↗

Modeling the X-ray Process, and X-ray Flaw Size Parameter for POD Studies

Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances, the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters, including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

Koshti, Ajay M.↗

Evaluating the Sensitivity of Agricultural Model Performance to Different Climate Inputs: Supplemental Material

Projections of future food production necessarily rely on models, which must themselves be validated through historical assessments comparing modeled and observed yields. Reliable historical validation requires both accurate agricultural models and accurate climate inputs. Problems with either may compromise the validation exercise. Previous studies have compared the effects of different climate inputs on agricultural projections but either incompletely or without a ground truth of observed yields that would allow distinguishing errors due to climate inputs from those intrinsic to the crop model. This study is a systematic evaluation of the reliability of a widely used crop model for simulating U.S. maize yields when driven by multiple observational data products. The parallelized Decision Support System for Agrotechnology Transfer (pDSSAT) is driven with climate inputs from multiple sources reanalysis, reanalysis that is bias corrected with observed climate, and a control dataset and compared with observed historical yields. The simulations show that model output is more accurate when driven by any observation-based precipitation product than when driven by non-bias-corrected reanalysis. The simulations also suggest, in contrast to previous studies, that biased precipitation distribution is significant for yields only in arid regions. Some issues persist for all choices of climate inputs: crop yields appear to be oversensitive to precipitation fluctuations but under sensitive to floods and heat waves. These results suggest that the most important issue for agricultural projections may be not climate inputs but structural limitations in the crop models themselves.

simulation↗

Effect of Synergistic Space Effects on Properties of Novel Polymer Composite Materials (PCM)

Evaluate the long-term performance of composite materials in space by exposing them to the actual space environment and analyzing changes in their interfacial properties, using the International Space Station (ISS) and the MISSE for experimentation. This research could assist in the design of future spacecraft, assessing risk and enhancing safety and reliability of spacecraft structural materials for space exploration.

R Vaidyanathan↗

Oculomotor Assessment of Diurnal Arousal Variations

Saccadic and pupillary responses are reliable indices of arousal decrement (e.g. fatigue), that might be exploited to improve work schedule guidelines. In this study, we tested the sensitivity of a short 30-s oculomotor test to detect diurnal arousal variations. Twelve participants (5 females, 7 males, 37.7+-11.9 years) volunteered to be assessed every hour (66+-20 min) for three consecutive working days, during their regular office-hours. We used a fully automated testing system, the FIT 2000 Fitness Impairment Tester (Pulse Medical Instruments Inc., Rockville, MD, USA), to measure and record saccadic peak velocity, pupil diameter, and latency and amplitude of the pupillary light reflex. In addition, we collected subjective levels of arousal using the Stanford Sleepiness Scale, and body core temperature. We analyzed the data using a linear mixed model approach for longitudinal data. Both saccadic velocity and subjective alertness decreased over the course of a day, while body core temperature increased (all p-values.05). The data also weakly suggested an increase of the pupil diameter (p 07). The findings support the use of oculomotor indices in the assessment of arousal and fatigue in applied settings.

saccadic velocity↗

Review of the Toxicity of the Metallic Compounds Proposed for Use in the New Green Missile Formulation

In an effort to modernize and minimize hazards posed by the toxic components of missile propellant, the USACHPPM has been tasked to provide a comparison of the toxicity of compounds currently in use as missile propellants and the suite of compounds proposed to replace them. This report deals with the portion of this work concerning the toxicity of the organometallic compounds used in these formulations. Toxicity assessments of the organic compounds used in these formulations are published elsewhere. In general, toxicity data were available for all the metal compounds of concern or for closely related compounds that can serve as surrogates for the assessment of toxicity. We have high confidence in the reliability of these comparisons. This report is organized by element to provide the reader with an in-depth assessment with a minimum of redundancy. The narrative will first describe general concepts about the toxicity of each metal and then provide a summary of the toxicological information available for the specific compound.

Major, Michael A.↗

A Critique of a Phenomenological Fiber Breakage Model for Stress Rupture of Composite Materials

Stress rupture is not a critical failure mode for most composite structures, but there are a few applications where it can be critical. One application where stress rupture can be a critical design issue is in Composite Overwrapped Pressure Vessels (COPV's), where the composite material is highly and uniformly loaded for long periods of time and where very high reliability is required. COPV's are normally required to be proof loaded before being put into service to insure strength, but it is feared that the proof load may cause damage that reduces the stress rupture reliability. Recently, a fiber breakage model was proposed specifically to estimate a reduced reliability due to proof loading. The fiber breakage model attempts to model physics believed to occur at the microscopic scale, but validation of the model has not occurred. In this paper, the fiber breakage model is re-derived while highlighting assumptions that were made during the derivation. Some of the assumptions are examined to assess their effect on the final predicted reliability.

Reeder, James R.↗

Research requirements to improve reliability of civil helicopters

The major reliability problems of the civil helicopter fleet as reported by helicopter operational and maintenance personnel are documented. An assessment of each problem is made to determine if the reliability can be improved by application of present technology or whether additional research and development are required. The reliability impact is measured in three ways: (1) The relative frequency of each problem in the fleet. (2) The relative on-aircraft manhours to repair, associated with each fleet problem. (3) The relative cost of repair materials or replacement parts associated with each fleet problem. The data reviewed covered the period of 1971 through 1976 and covered only turbine engine aircraft.

Dougherty, J. J., III↗

Distributed processing on the Space Shuttle - A case study

A Power Extension Package (PEP) has been designed to provide additional electrical power and energy during Shuttle sortie missions. The considered investigation was conducted to determine the most suitable allocation of PEP monitoring and control functions between the Orbiter's existing (centralized) Systems Management General Purpose Computer and an embedded PEP processor. PEP monitoring and control functions are examined, and a configuration definition is considered, taking into account the 'functional migration' process, function allocation criteria, and candidate functional configurations. A trade study is conducted, giving attention to an assessment of four candidate configurations. Assessment factors are related to cost, development risk, aspects of reliability and safety, PEP design complexity, PEP/STS integration complexity, flight operations, and launch/landing site operations. A thorough (subjective) assessment of the PEP system life cycle indicates substantial benefits from a distributed processing approach.

Schoonmaker, P. B.↗