Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Elucidation of the chemical environment for zinc species in an electron-rich zinc-incorporated zeolite

An electron-rich zinc-modified zeolite has been prepared by the incorporation of zinc vapor into the channels of a dehydrated HY (protonated zeolite Y). The chemical environment of the zinc species in the electron-rich zeolite has been elucidated on the basis of X-ray absorption spectroscopy. The formation of univalent zinc (Zn{sup +}) within the electron-rich zeolite was observed upon the irradiation of X-ray from either a synchrotron radiation source or a conventional X-ray diffractometer. The X-ray irradiation initiated the electron transfer from the electron-rich framework of zeolite Y to the nearby Zn{sup 2+} cations, generating Zn{sup +} species. The variation of the coordination environment of the zinc species upon interaction with water molecules has also been investigated. - Graphical abstract: The chemical environment of the zinc species in an electorn-rich zeolite has been elucidated on the basis of X-ray absorption spectroscopy. - Highlights: • An electron-rich zinc-incorporated zeolite has been prepared by chemical vapor reaction. • Univalent zinc is detected after the electron-rich zeolite is irradiated with X-ray. • The chemical environment of the zinc species is elucidated by X-ray absorption spectroscopy. • The coordination environment of the zinc species changes upon interaction with water molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On origin and destruction of relativistic dust and its implication for ultrahigh energy cosmic rays

Dust grains may be accelerated to relativistic speeds by radiation pressure, diffusive shocks, and other acceleration mechanisms. Such relativistic grains have been suggested as primary particles of ultrahigh energy cosmic rays (UHECRs). In this paper, we first revisit the problem of acceleration by radiation pressure and calculate maximum grain velocities achieved. We find that grains can be accelerated to relativistic speeds with Lorentz factor γ<2 by powerful radiation sources, which is lower than earlier estimates showing that γ could reach ∼10. We then investigate different destruction mechanisms for relativistic grains traversing a variety of environments. In solar radiation, we find that the destruction by thermal sublimation and Coulomb explosions is important. We also quantify grain destruction due to electronic sputtering by ions and grain–grain collisions. Electronic sputtering is found to be rather inefficient, whereas the evaporation following grain–grain collisions is shown to be an important mechanism for which the a ∼ 0.01–1 μm grains would be destroyed after sweeping a gas column N{sub coll}∼5×10{sup 19}–5×10{sup 20} cm{sup −2}. Relativistic dust in the interstellar medium and intergalactic medium (IGM) would be disrupted by Coulomb explosions due to collisional charging after traversing a gas column N{sub coll}∼10{sup 17} cm{sup −2} unless grain material is very strong. We show that photoelectric emission by optical and ultraviolet background radiation is also significant for the destruction of relativistic dust in the IGM. The obtained results indicate that relativistic dust from galaxies would be destroyed before reaching the Earth's atmosphere and unlikely to account for UHECRs.

79 ASTRONOMY AND ASTROPHYSICS↗

SCALE Validation Experience Using an Expanded Isotopic Assay Database for Spent Nuclear Fuel

The availability of measured isotopic assay data to validate computer code predictions of spent fuel compositions applied in burnup-credit criticality calculations is an essential component for bias and uncertainty determination in safety and licensing analyses. In recent years, as many countries move closer to implementing or expanding the use of burnup credit in criticality safety for licensing, there has been growing interest in acquiring additional high-quality assay data. The well-known open sources of assay data are viewed as potentially limiting for validating depletion calculations for burnup credit due to the relatively small number of isotopes measured (primarily actinides with relatively few fission products), sometimes large measurement uncertainties, incomplete documentation, and the limited burnup and enrichment range of the fuel samples. Oak Ridge National Laboratory (ORNL) recently initiated an extensive isotopic validation study that includes most of the public data archived in the Organization for Economic Cooperation and Development/Nuclear Energy Agency (OECD/NEA) electronic database, SFCOMPO, and new datasets obtained through participation in commercial experimental programs. To date, ORNL has analyzed approximately 120 different spent fuel samples from pressurized-water reactors that span a wide enrichment and burnup range and represent a broad class of assembly designs. The validation studies, completed using SCALE 5.1, are being used to support a technical basis for expanded implementation of burnup credit for spent fuel storage facilities, and other spent fuel analyses including radiation source term, dose assessment, decay heat, and waste repository safety analyses. This paper summarizes the isotopic assay data selected for this study, presents validation results obtained with SCALE 5.1, and discusses some of the challenges and experience associated with evaluating the results. Preliminary results obtained using SCALE 6 and ENDF/B-VII cross sections libraries are also briefly summarized. Oak Ridge National Laboratory (ORNL) has been performing spent-fuel isotopic validation studies using the depletion analysis methods in the SCALE [1] code system for the past 20 years. These studies involve comparisons of calculated inventories against measured isotopic composition data obtained from destructive radiochemical analysis of commercial spent nuclear fuel samples. The results of these benchmark studies are used to quantify the bias and uncertainties associated with isotopic calculations and ultimately determine appropriate margins for uncertainty that can be applied in safety-related analyses such as burnup credit in criticality calculations, decay heat analysis, and source terms. Previous studies using several versions of SCALE and nuclear data libraries have been published in multiple validation reports [2-6] that evaluate selected experimental data obtained largely from public sources. A study was recently initiated at ORNL with the objectives of updating and expanding the validation calculations using a comprehensive database of experimental isotopic assay data that includes isotopic composition data obtained from both publicly available sources and international commercial programs. As part of the study, an extensive isotopic database of nearly 120 measured spent fuel samples with an expanded range of initial enrichments and burnup values compared to previously analyzed data was reviewed and analyzed. The calculations were performed using two-dimensional (2-D) assembly models and a consistent set of modeling assumptions using the SCALE 5.1 code system and ENDF/B-V 44-group cross section library. As part of the current study, detailed benchmark modeling information and measurement data are being documented in a format that is readily usable for validating depletion and decay codes. The work is being extended to include analysis results using SCALE 6 and the ENDF/B-VII 238-group cross section library. This paper describes the isotopic composition data evaluated in this study and highlights the preliminary findings to date.

07 ISOTOPE AND RADIATION SOURCES↗

Broadband impedance modeling and single bunch instabilities estimations of the advanced light source upgrade project

We report the Advanced Light Source Upgrade (ALS-U) is a 4th generation diffraction-limited soft x-ray radiation source, consisting of a new accumulator ring (AR) and a new storage ring (SR). In both rings coupling-impedance driven instabilities need careful evaluation to ensure meeting the machine’s high-performance goals. This paper presents the workflow followed in building the impedance models and the beam-stability analysis based on those models. We follow the commonly accepted approach of separating the resistive-wall and the geometric parts of the impedance; the former is obtained by analytical formulas, the latter by numerical electro-magnetic codes (primarily CST Studio software) with perfectly-conducting boundary conditions. Impedance budgets are established and pseudo-Green functions calculated to be used in beam dynamics studies. We also present various ways to cross-check simulation results for reliable impedance modeling. Finally, the crucial single-bunch instability current thresholds for various operation modes are determined and discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Metallomics and Metalloproteomics

Metallomics and metalloproteomics are emerging fields addressing the role, uptake, transport and storage of trace metals essential for protein functions. The methodologies utilized in metallomics and metalloproteomics to provide information on the identity, quantity and function of metalloproteins are discussed. The most widely used approach is through inductively coupled plasma mass spectrometry to identify the metal bound to a protein, and electrospray ionization mass spectrometry to elucidate the structure, dynamics and function of a metal-protein complex. Other approaches include X-ray absorption and X-ray fluorescence spectroscopies, and bioinformatics sequence analysis. X-ray absorption spectroscopy utilizing a synchrotron radiation source is a powerful tool to provide a direct analysis of metal bound to proteins and proteomic metal distribution in biological matrices. With the advent of genome sequencing, a large database of protein primary structures has been established, and specific tools to identify metalloproteins in the genome sequences have been developed.

43 PARTICLE ACCELERATORS↗

Test Study for Generation of Short Pulsed Synchrotron Radiation by Kicker Magnet in SPring-8 Storage Ring

A shorter pulse of synchrotron radiation is desired to measure a fast dynamic process exploration with a better resolution by material structure physics users. Among many complex schemes proposed for this purpose, we tested a simple scheme which makes use of a head-tail oscillation of a circulating electron beam with a small beam emittance. We have developed a new kicker magnet system which generated a short pulsed horizontal field of about 4.19 mT in 1.4 {mu}s pulse width with 1 Hz repetition. With this new developed kicker magnet system, we observed a bunch profile which leaned impressively between head and tail position by a visible light streak camera. Then we succeeded in achieving the shorter X-ray pulse width than the original one after a vertical slit being sliced by {approx}6 times. The observed X-ray pulse width was 7.38{+-}2.35 ps in FWHM.

43 PARTICLE ACCELERATORS↗

Development of Hard X-ray Imaging Optics with Two Pairs of Elliptical and Hyperbolic Mirrors

To form a magnified hard X-ray image with a 50 nm resolution, we have studied total reflection mirror optics with two pairs of elliptical and hyperbolic mirrors, which is called 'Advanced Kirkpatrick-Baez system'. A designed optical system has 200x and 300x magnifications in vertical and horizontal directions. Also diffraction limit size in the optical system is 40 nmx45 nm. We fabricated a pair of elliptical and hyperbolic mirrors for horizontal imaging with a figure accuracy of 2 nm using elastic emission machining (EEM), microstitching interferometry (MSI) and relative-angle-determinable stitching interferometry (RADSI). One-dimensional tests for forming a demagnified image of a slit were carried out at an X-ray energy of 11.5 keV at BL29XUL (EH2) of SPring-8. As a result, a shape beam with a FWHM of 78 nm was observed. This demonstrates that we realized one-dimensional Wolter optics that has a spatial resolution of 78 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FINEST: a high performance branch-line for VUV photon energy range gas phase studies at MAX-lab

We present a dedicated beamline branch for high flux and ultra-high resolution (R>100000) gas and vapor phase studies in the vacuum-ultra-violet (VUV) region of light on the undulator beamline I3, located on the 700 MeV MAX-III storage ring. The mechanical and optical design of the branch-line, the differential pumping setup as well as performance characteristics are presented.

43 PARTICLE ACCELERATORS↗

The Optimized Design of Undulators for the HiSOR Users Experiments

The HiSOR is a small racetrack type storage ring aiming for usage of synchrotron radiation. This ring is equipped with two undulators. One of them is a linear undulator and another is a helical one. These undulators serve high-flux VUV photon beams. Therefore, these beamlines are oversubscribed mainly for the high precision photo-electron spectroscopy experiments to investigate various materials. To solve this problem, we investigated possibilities to replace present undulators and beamline optics to those with better performance. One of such candidate undulator beamlines is a two-branch-beamline with a single elliptical undulator. Another candidate is a beamline equipped with a quasi-periodic undulator.

43 PARTICLE ACCELERATORS↗

Integration of an Atomic Force Microscope in a Beamline Sample Environment

We developed and optimised an optics-free Atomic Force Microscope (AFM) that can be directly installed on most of the synchrotron radiation end-stations. The combination of Scanning Probe Microscopies with X-ray microbeams adds new possibilities to the variety of synchrotron radiation techniques. The instrument can be used for atomic force imaging of the investigated sample or to locally measure the X-ray absorption or diffraction, or it can also be used to mechanically interact with the sample while simultaneously taking spectroscopy or diffraction measurements. The local character of these measurements is intrinsically linked with the use of the Atomic Force Microscope tip. It is the sharpness of the tip that gives the opportunity to measure the photons flux impinging on it giving beam position monitor features, or allows to locally measure the absorption coefficient or the shape of the diffraction pattern. As an example of the possibilities opened by the instrument we will show diffraction measurements performed on a Ge/Si island while being indented with the AFM tip providing local measure of the Young coefficient. Three ESRF beamlines are going to be equipped with this new instrument.

43 PARTICLE ACCELERATORS↗

The New ESRF Multilayer Facility: Progress and Perspectives

In view of the increasing need for high quality multilayer based x-ray optics the ESRF decided to upgrade its multilayer facility. During the last years a new deposition system was designed, installed, and commissioned. Since 2008 the new laboratory is operational and has produced its first optical elements for ESRF beamlines. The deposition system is based on magnetron sputtering and can cover optical surfaces up to 1000x150 mm{sup 2} with uniform or graded coatings. Four cathodes allow the use of conducting, insulating, and ferromagnetic target materials. This work will provide an overview on the machine conception and its overall performance, including a comparison with the formerly used system. It will be complemented by first fabrication results and perspectives for future projects in the framework of the ESRF Upgrade Programme.

43 PARTICLE ACCELERATORS↗

Calibration of a Gas Monitor Detector using a Cryogenic Radiometer for Measuring the Radiant Power of Extreme Ultraviolet Free Electron Laser at SPring-8

A gas monitor detector was calibrated to a cryogenic radiometer for measuring the radiant power of EUV-FEL (extreme ultraviolet free electron laser) at the wavelengths of 51 nm and 61 nm. The output signals of the gas monitor detector showed good linearity against the radiant power measured by the radiometer in the range from 6 {mu}W to 160 {mu}W. The calibration coefficients of the gas monitor detector are determined with the relative standard uncertainty of around 5 %.

43 PARTICLE ACCELERATORS↗

Fluorescence-type Monochromatic X-ray Beam-position Monitor with High-spatial Resolution for the NSLS-II Beamlines

We developed a fluorescence-type monochromatic X-ray beam-position monitor (X-BPM) with high-spatial resolution for end-station experiments at the initial project beamlines of the NSLS-II. We designed a ring array of multi-segmented Si PIN-junction photodiodes to use as a position sensor. Further, we integrated a low-noise charge-preamplification HERMES4 ASIC chip into an electronic readout system for photon-counting application. A series of precision measurements to characterize electronically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise from the detector system is sufficiently low to meet our stringent requirements. Using a Gaussian beam, we parametrically modeled the optimum working distance to ensure the detector's best performance. Based upon the results from the parametric modeling, prototypes of the next versions of the X-BPM are being developed. In this paper, we describe the methodology for developing the new compact monochromatic X-ray BPM, including its instrumentation, detector modeling, and future plan.

43 PARTICLE ACCELERATORS↗

The RIKEN Materials Science Beamline at SPring-8: Towards Visualization of Electrostatic Interaction

In order to visualize molecular interaction by the experimental electrostatic potential analysis we have optimized the optical parameters and developed the high-resolution Debye-Scherrer camera at the RIKEN materials science beamline, BL44B2 of SPring-8. For the purpose the camera was designed to be equipped with the hybrid X-ray detector system. One is the conventional detector, the imaging plate readout off-line to carry out high d(interplanar spacing)-resolution measurements and the other is the CCD detector, which can be operated in a camera at variable distances for high angle-resolution measurements. In addition we have been developing an in-situ properties measurement system to visualize the electrostatic interaction completely synchronized with material functions.

43 PARTICLE ACCELERATORS↗

COMPARISON OF THE DIFFUSE H{alpha} AND FUV CONTINUUM BACKGROUNDS: ON THE ORIGINS OF THE DIFFUSE H{alpha} BACKGROUND

We compare the diffuse H{alpha} map of our Galaxy with the FUV (1370-1710 A) continuum map. The H{alpha} intensity correlates well with the FUV intensity. The H{alpha}/FUV intensity ratio increases in general with the H{alpha} intensity and the FUV hardness ratio (1370-1520 A to 1560-1710 A), implying that late OB stars may be the main source of the H{alpha} recombination line at high latitudes. The variation of the H{alpha} intensity as a function of the Galactic latitude is also very similar to that of the FUV intensity. The results likely suggest that not only the original radiation sources of the H{alpha} and FUV backgrounds but also the radiative transfer mechanisms responsible for the diffuse backgrounds are largely common. Therefore, we propose a scenario wherein the H{alpha} background at high latitudes is mostly composed of two components, H{alpha} photons produced by in situ recombination at the ionized regions around late OB stars and dust-scattered light of the H{alpha} photons originating from late OB stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum-dot-array diffraction grating with single order diffraction property for soft x-ray region

A gold transmission grating is used routinely to disperse the x-ray spectrum at the Z soft x-ray facility to measure the spectrum and temporal history of the absolute soft x-ray power emitted from z-pinch and hohlraum radiation sources. A quantum-dot-array diffraction grating (QDADG) of 250 lines/mm for soft x-ray is designed and fabricated for the first time according to the principle of binary sinusoidal transmission grating. The diffraction efficiencies of the grating are measured in the 150-300 eV photon energy range on the Beamline 3W1B of Beijing Synchrotron Radiation Facility. This article describes the basic concept and calibration techniques and presents calibration results. It is shown that the 250 lines/mm QDADG can be used to disperse light without higher-order diffractions in soft x-ray range, and the diffraction efficiencies of this grating are nearly constant (about 25%), which is beneficial in the spectrum analysis.

43 PARTICLE ACCELERATORS↗

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage induced by intense synchrotron radiation sources is indispensable for the correct interpretation of scattering data, there is still a lack of effective methods to overcome radiation-induced aggregation and extract scattering profiles free from chemical or structural damage. It is found that radiation-induced aggregation mainly begins on the surface of the sample cell and grows along the beam path; the diameter of the damaged region is comparable to the x-ray beam size. Radiation-induced aggregation can be effectively avoided by using a two-dimensional scan (2D mode), with an interval as small as 1.5 times the beam size, at low temperature (e.g., 4 deg. C). A radiation sensitive protein, bovine hemoglobin, was used to test the method. A standard deviation of less than 5% in the small angle region was observed from a series of nine spectra recorded in 2D mode, in contrast to the intensity variation seen using the conventional stationary technique, which can exceed 100%. Wide-angle x-ray scattering data were collected at a standard macromolecular diffraction station using the same data collection protocol and showed a good signal/noise ratio (better than the reported data on the same protein using a flow cell). The results indicate that this method is an effective approach for obtaining precise measurements of protein solution scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗