Fracture of silicon carbide whisker reinforced aluminum
An attempt is made to apply standard fracture toughness testing procedures, developed for metals, to whisker reinforced metal matrix composites. Test were carried out on compact-tension, center-notched, and edge-notched specimens of silicon carbide whisker reinforced extruded 2124 aluminum plate (10 and twenty volume percent of whiskers), with the loading direction either parallel or perpendicular to the extrusion direction. None of the tests is found to give a valid fracture toughness according to the criteria of the ASTM Standard E-399.