Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Radiation detector readout system Patent

Circuit design for determining amount of photomultiplier tube light detection utilizing variable current source and dark current signals of opposite polarity

Baker, B. R.↗

ERTS direct readout ground station study

A system configuration which provides for a wide variety of user requirements is described. Two distinct user types are considered and optimized configurations are provided. Independent satellite transmission systems allow simultaneous signal transmission to Regional Collection Centers via a high data rate channel and to local users who require near real time consumption of lower rate data. In order to maximize the ultimate utility of this study effort, a parametric system description is given such that in essence a shopping list is provided. To achieve these results, it was necessary to consider all technical disciplines associated with high resolution satellite imaging systems including signal processing, modulation and coding, recording, and display techniques. A total systems study was performed.

Source record↗

Working model of the London moment readout system

The operating characteristics of a porous plug which has liquid helium on one side and which is pumped on under vacuum on the other side are discussed. The system investigated consists of a container of liquid helium which is well isolated, and the only means for mass flow out of the container is through a plug mode of porous material. The plug was assumed to have liquid helium on the container side while the other side of the plug is evacuated. Three cases were considered: (1) perfect evacuation with zero pressure, (2) evacuation through a chocked orifice, and (3) evacuation through a long, small diameter pipe with heating. Mass flow rates were determined along with mass flow at temperature above the lambda point temperature. Solutions were obtained for normal and superfluid velocity.

Hendricks, J. B.↗

A SQUID readout system for a superconducting gyroscope

A design of a read out system for a superconducting gyroscope to be used in an orbiting gyroscope relativity experiment is discussed. The 'London Moment' of the superconducting rotor, which lies along the spin axis of the rotor, will be measured with a SQUID-type magnetometer. The SQUID will be built around the gyro rotor, with a very close spacing to give an inductance between 10 millionths and 1 millionth Hy. A SQUID of this design should resolve 2.07 times 10 to the minus 19th weber. The angular resolution of the gyroscope will then be 0.0035 arc-second, which is sufficient for the intended experiment.

Hendricks, J. B.↗

Simpler cabling and power link for remote readouts

Display power and segment data are multiplexed over same coaxial line. Thus, only one wire and return lead are needed, and single power supply at central location can service all remote displays.

Perry, J. C.↗

Portable high-resolution laser monochromator-interferometer with multichannel electronic readout

A high-resolution 0.4-m monochromator is described for use in wavelength diagnosis of tunable pulsed and CW laser sources in the 3000-10,000-A region. The f/20 design uses an echelle grating in an over-and-under Ebert configuration with a scanned photodiode array to provide a real-time multichannel display of spectral output. Absolute wavelength may be determined to 0.1 A with the monochromator, and a Fabry-Perot interferometer attachment extends linewidth measurement capability to 0.01 A or better. Spectra are displayed on a storage oscilloscope, and calculation of laser parameters is explained. The instrument measures 70 cm long x 15 cm wide x 20 cm high.

Morris, M. B.↗

Development of a London moment readout for a superconducting gyroscope

A gyroscope for verifying certain predictions of General Relativity is under development at Stanford. A method of measuring the gyroscope orientation based on the use of the London moment and a SQUID magnetometer is described. It is estimated that the required sensitivity of 1 milliarc-sec can be achieved in a bandwidth of 2.5 times 10 to the -6th Hz.

Anderson, J. T.↗

Circular-scan streak tube with solid-state readout

A circular-scan streak tube designed for use in a laser ranging system is described. Electrostatic focusing is used between the photocathode and a microchannel plate, and electrons from the microchannel plate are proximity focused onto an output phosphor screen. Electron beam deflection is achieved by driving two orthogonal sets of deflection plate assemblies in phase quadrature at a frequency of 200 MHz. The light intensity in the output beam trace is measured by using a circular Reticon array of 720 photodiodes, which is fiber-optically coupled to the output phosphor screen of the tube. Sample measurements of frequency-doubled Nd:YAG laser-pulse waveforms are given. Also the output beamwidth has been measured at the 200-MHz deflection frequency. The results suggest a limiting resolution of 33 psec for the circular-scan streak tube used for these tests.

Johnson, C. B.↗

Evaluation of a Si:Ga direct readout array

Preliminary results from the Hughes 58 x 62 gallium-doped silicon infrared array are presented. The device functioned predictably and repeatedly at the low temperatures for the Space Infrared Telescope Facility (SIRTF). Power dissipation was reduced to acceptable levels while still maintaining the device speed. The infrared response was excellent and the degree of anomalous effects was compatible to conventional photoconductors.

Lamb, G. M.↗

Wedge and strip image readout systems for photon-counting detectors in space astronomy

EUV and far UV applications of wedge and strip anodes in photon-counting microchannel plate detector systems are discussed in light of performance data obtained as a result of EUV Explorer spacecraft open face detector and FAUST-Spacelab far UV sealed tube sensor calibrations. CsI quantum detection efficiencies of about 80 percent at 114 A and about 40 percent at 600 and 1300 A have been achieved; a position sensitivity of less than 10 microns is demonstrated, and the position resolution, image linearity, background rate, and flat-field characteristics are discussed.

Siegmund, O. H. W.↗

Application of wedge and strip image readout systems to detectors for astronomy

Microchannel plate (MCP) detector systems that use wedge and strip anodes for imaging radiation in the range 50 A to 8000 A are described. Test data, obtained from the calibration of the Extreme Ultraviolet Explorer Satellite detectors and the ARIA EUV aeronomy sensor is presented. The long-term performance characteristics of Z-stack microchannel plates are investigated and it is shown that stable operation is achieved after an initial settling period. Conventional and new anode designs and their potential for increasing the position resolution are discussed. Position resolution of better than 80 microns FWHM has been attained for 50 mm devices, and this is shown to be essentially independent of event location. Image nonlinearity of less than 0.3 percent has been achieved with stability to better than 0.1 percent. Differential nonlinearity of less than 1 percent and stability to better than 1 percent have been obtained. Measurements of the quantum efficiency of a CsI photocathode on an MCP are presented, demonstrating efficiencies as high as 47 percent.

Siegmund, O. H. W.↗

Linear capacitive displacement sensor with frequency readout

A simple, inherently linear technique for measuring changes in the separation of the mirrors of an optical cavity is reported. The capacitor, made up of the reflective metallic coatings, is part of a feedback loop which adjusts the frequency of an oscillator to be proportional to the mirror separation. A linearity of 0.2 percent full scale was achieved for separations up to 0.5 mm with a resolution of 10 nm.

Fritsch, Klaus↗

Spectral contents readout of birefringent sensors

The objective of the research performed was to establish the feasibility of using spectral contents analysis to measure accurately, strains and retardation in birefringent sensors, and more generally, on transparent materials.

Redner, Alex S.↗

Gas scintillation drift chambers with wave shifter fiber readout

Results for a prototype xenon gas scintillation drift chamber are presented. Its operation is discussed using two types of light detection schemes: one based on an Anger camera geometry and one based on an array of wave-shifting light fibers. The results are judged to demonstrate the instrument's potential.

Sadoulet, Bernard↗

Capacitive Displacement Sensor With Frequency Readout

Simple displacement-measuring circuit senses capacitance between two parallel conducting plates and produces output signal, with frequency proportional to distance between plates. Principle of circuit provides advantages over other methods because of frequency-encoded output and high linearity. Used to measure displacements.

Fritsch, Klaus↗

Spectral-Content Readout Of Stress-Induced Birefringence

Spectrum of transmitted light indicates stress in sensor or specimen. Photoelastic apparatus demonstrates feasibility of analysis of spectrum of transmitted light to quantify birefringence in transparent specimen. By augmenting conventional photoelastic analysis with spectral sensors and automating it with computer control and processing of data, technique made more versatile and useful. Potential uses include measurement of stresses in optical fibers and transparent materials in general.

Redner, Alex S.↗

High resolution vidicon-based readout system for photon-counting streak camera applications

The design, implementation, and evaluation of a high-resolution vidicon-based reconfigurable imaging system for integration into a photon-counting streak camera that can be readily coupled to a standard interface and computer have been achieved. Experimental results are reported which demonstrate that the design goals are met, providing the capability to measure differential time to better than 3 picosecond accuracy. Augmented by real-time calibration, the accuracy, linearity, noise levels, and stability of the system are adequate to support dual wavelength laser ranging.

Varghese, Thomas K.↗