Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIO NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Acceleration of ordering transformation of a new Fe{sub 2}(Mn,Cr)Si Heusler-alloy film by very high frequency plasma irradiation process during radio frequency sputter deposition

A new Heusler alloy, Fe{sub 2}(Mn,Cr)Si, that is likely to have high spin polarization (P) and high damping constant ({alpha}) was proposed to obtain high magneto-resistance ratio and low spin torque noise in a magnetic read head with a current-perpendicular-to-plane (CPP) giant magneto-resistance (GMR) multilayer. A very high frequency (VHF) plasma irradiation process during radio frequency (RF) sputter deposition was investigated to form the highly ordered structure of the Heusler alloy film with low thermal treatment temperature. The main results are as follows: (1) P and magnetic moment of Fe{sub 2}(Mn{sub 0.5}Cr{sub 0.5})Si with an L2{sub 1} structure were estimated at 0.99 and 2.49 {mu}{sub B}/f.u., respectively, and {alpha} was also estimated to be larger compared with the case of Co{sub 2}MnSi, according to density of states (DOS) calculations. (2) The ordering (at least B2 structure) temperature of Fe{sub 2}(Mn{sub 0.6}Cr{sub 0.4})Si film decreased from 500 to 300 deg. C by using the VHF plasma irradiation process with optimized condition. (3) The surface roughness of Fe{sub 2}(Mn{sub 0.6}Cr{sub 0.4})Si film also reduced from 1.7 to 0.5 nm by using the VHF plasma irradiation process. It is found that the Fe{sub 2}(Mn,Cr)Si Heusler alloy and the VHF plasma irradiation process with optimized condition seems to be applicable for fabrication of high-performance magnetic read head with CPP-GMR device.

36 MATERIALS SCIENCE↗

Deep-Space Navigation Using Optical Communications Systems

Optical communication links using lasers can potentially deliver data rates much higher than those possible using radio frequencies. If optical communications equipment is going to be carried by future deep-space missions, this equipment, with some adaptations, could also be used to perform tracking for trajectory determination. A number of experiments have been performed in Earth orbit and in lunar orbit using optical data links, while other missions have demonstrated optical links over interplanetary distances. Laser ranging using corner cube retroreflectors is a well-established technique that has been used for orbit determination of Earth orbiting spacecraft, for geodesy, and for lunar research, achieving centimeter-level precisions, but it is not a practical method for deep-space distances. There are two main optical tracking types that are being considered for deep-space navigation. The first is optical astrometry of spacecraft: a telescope on the ground images the laser beam coming from a spacecraft against the star background, determining its plane-of-sky position as seen from the observatory. This type will greatly benefit from the release of the high-accuracy star catalog produced by ESA’s Gaia mission, allowing for the generation of plane-of-sky measurements with an accuracy similar to that obtained today using VLBI tracking techniques. The second is optical ranging using active optical systems at both ends of the link, requiring a more careful design of the spacecraft optical communications system. One of the advantages of using optical frequencies is that they are not affected by charged particles in the signal path the way that radio frequencies are, eliminating solar plasma and ionospheric effects from the light-time calculation and the corresponding noise. On the other hand, clouds would preclude any type of optical communication, and daytime light scattering precludes astrometric measurements. This paper presents our analysis so far of the performance that could be achieved using optical data types in a number of deep-space scenarios. One of the questions that we are trying to answer is whether spacecraft equipped with optical communications terminals would also need to carry radio-frequency equipment for navigational purposes. We also want to understand how accurately we will be able to navigate spacecraft in different mission types and phases, and what would be the constraints, advantages, and disadvantages of using optical communications systems for deep-space navigation.

Karimi, Reza↗

A 492 GHz cooled Schottky receiver for radio-astronomy

We developed a 492 GHz cooled GaAs Schottky receiver driven by a solid state local oscillator with a DSB noise temperature of 550 K measured at the telescope. The receiver-bandwidth is approx. equal to 1.0 GHz. Quasi-optical mirrors focus the sky and local oscillator radiation into the mixer. Stability analysis via the Allan variance method shows that the total system including a 1 GHz bandwidth acousto-optical spectrometer built in Cologne allows integration times up to 100 sec per half switching cycle. We successfully used the receiver at the KOSMA 3 m telescope on Gornergrat (3150m) located in the central Swiss Alps near Zermatt during January-February 1992 for observations of the 492 GHz, (CI) (3)P1 to (3)P0 fine structure line in several galactic sources. These observations confirm that Gornergrat is an excellent winter submillimeter site in accordance with previous predictions based on the atmospheric opacity from KOSMA 345 GHz measurements.

Hernichel, J.↗

VERY LARGE ARRAY 1.4 GHz OBSERVATIONS OF THE GOODS-NORTH FIELD: DATA REDUCTION AND ANALYSIS

We describe deep, new, wide-field radio continuum observations of the Great Observatories Origins Deep Survey-North field. The resulting map has a synthesized beam size of {approx}1.''7 and an rms noise level of {approx}3.9 {mu}Jy beam{sup -1} near its center and {approx}8 {mu}Jy beam{sup -1} at 15' from phase center. We have cataloged 1230 discrete radio emitters, within a 40' x 40' region, above a 5{sigma} detection threshold of {approx}20 {mu}Jy at the field center. New techniques, pioneered by Owen and Morrison, have enabled us to achieve a dynamic range of 6800:1 in a field that has significantly strong confusing sources. We compare the 1.4 GHz (20 cm) source counts with those from other published radio surveys. Our differential counts are nearly Euclidean below 100 {mu}Jy with a median source diameter of {approx}1.''2. This adds to the evidence presented by Owen and Morrison that the natural confusion limit may lie near 1 {mu}Jy. If the Euclidean slope of the counts continues down to the natural confusion limit as an extrapolation of our log N-log S, this indicates that the cutoff must be fairly sharp below 1 {mu}Jy else the cosmic microwave background temperature would increase above 2.7 K at 1.4 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Radio frequency science considerations

Use of the 400 MHz telecommunications system to obtain scientific information, to provide backup information for the experiments flown, and to obtain measurements which aid in designing future probes is considered. Recommended objectives of such a program are summarized and include: measure 400 MHz amplitude to determine adsorption and perhaps scintillation (if data rate permits); measure noise strength near 400 MHz to reexamine 400 MHz choice and to observe thermal, cosmic, and local synchrotron noise trends; probe VSWR sensing to monitor integrity of system, icing, and possible plasma effects; after the probe is finished, have the bus radio occultation in the same region where the probe fell to evaluate the occultation.

Croft, T. A.↗

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

CALDER: Cryogenic light detectors for background-free searches

The development of background-free detectors is essential for experiments searching for rare events. Bolometers, that are among the most competitive devices for the study of neutrino-less double beta decay (0νDBD) and Dark Matter interactions, suffer from the absence of techniques that allow to identify the nature of the interacting particles. This limit can be overcome by coupling the bolometer to an independent device for the measurement of the light emitted by interactions, as the combined read-out of the bolometric and light signals allows to identify and reject particles different from those of interest. CUORE, the most advanced bolometric experiment for 0νDBD searches, could disentangle the electrons produced by 0νDBD from the dangerous background due to α particles, by measuring the (tiny) Cherenkov light emitted by electrons and not by α’s. LUCIFER, a project based on ZnSe scintillating bolometers for the study of {sup 82}Se 0νDBD, would be competitive also in the search of Dark Matter interactions if equipped with light detectors that allow to distinguish and reject the background due to electrons and γ’s. These advances require cryogenic detectors characterized by noise lower than 20 eV, large active area, wide temperature range of operation, high radio-purity and ease in fabricating hundreds of channels. The CALDER collaboration aims to develop such detectors by exploiting the superb energy resolution and natural multiplexed read-out provided by Kinetic Inductance Detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PULSE INTENSITY MODULATION AND THE TIMING STABILITY OF MILLISECOND PULSARS: A CASE STUDY OF PSR J1713+0747

Most millisecond pulsars, like essentially all other radio pulsars, show timing errors well in excess of what is expected from additive radiometer noise alone. We show that changes in amplitude, shape, and pulse phase for the millisecond pulsar J1713+0747 cause this excess error. These changes appear to be uncorrelated from one pulse period to the next. The resulting time of arrival (TOA) variations are correlated across a wide frequency range and is observed with different backend processors on different days, confirming that they are intrinsic in origin and not an instrumental effect or caused by strongly frequency-dependent interstellar scattering. Centroids of single pulses show an rms phase variation Almost-Equal-To 40 {mu}s, which dominates the timing error and is the same phase jitter phenomenon long known in slower spinning, canonical pulsars. We show that the amplitude modulations of single pulses are modestly correlated with their arrival time fluctuations. We also demonstrate that single-pulse variations are completely consistent with arrival time variations of pulse profiles obtained by integrating N pulses such that the arrival-time error decreases proportional to 1/{radical}N. We investigate methods for correcting TOAs for these pulse-shape changes, including multi-component TOA fitting and principal component analysis. These techniques are not found to improve the timing precision of the observations. We conclude that when pulse-shape changes dominate timing errors, the timing precision of PSR J1713+0747 can be only improved by averaging over a larger number of pulses.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced transmitter development

Testing of high voltage power supply and linear exciter for Mariner transmitter noise amplitude modulation

SILICON CONTROL RECTIFIER /SCR/↗

Use of a priori statistics to minimize acquisition time for RFI immune spread spectrum systems

The optimum acquisition sweep strategy was determined for a PN code despreader when the a priori probability density function was not uniform. A psuedo noise spread spectrum system was considered which could be utilized in the DSN to combat radio frequency interference. In a sample case, when the a priori probability density function was Gaussian, the acquisition time was reduced by about 41% compared to a uniform sweep approach.

Holmes, J. K.↗

A design study of a signal detection system

A system is described which can aid in the search for radio signals from extraterrestrial sources, or in other applications characterized by low signal-to-noise ratios and very high data rates. The system follows a multichannel (16 million bin) spectrum analyzer, and has critical processing, system control, and memory fuctions. The design includes a moderately rich set of algorithms to be used in parallel to detect signals of unknown form. A multi-threshold approach is used to obtain high and low signal sensitivities. Relatively compact and transportable memory systems are specified.

Healy, T. J.↗

Modeling and investigative studies of Jovian low frequency emissions

Jovian decametric (DAM) and hectometric (HOM) emissions were first observed over the entire spectrum by the Voyager 1 and 2 flybys of the planet. They display unusual arc-like structures on frequency-versus-time spectrograms. Software for the modeling of the Jovian plasma and magnetic field environment was performed. In addition, an extensive library of programs was developed for the retrieval of Voyager Planetary Radio Astronomy (PRA) data in both the high and low frequency bands from new noise-free, recalibrated data tapes. This software allows the option of retrieving data sorted with respect to particular sub-Io longitudes. This has proven to be invaluable in the analyses of the data. Graphics routines were also developed to display the data on color spectrograms.

Menietti, J. D.↗

Frequency-Shift Hearing Aid

Proposed hearing aid maps spectrum of speech into band of lower frequencies at which ear remains sensitive. By redirecting normal speech frequencies into frequency band from 100 to 1,500 Hz, hearing aid allows people to understand normal conversation, including telephone calls. Principle operation of hearing aid adapted to other uses such as, clearing up noisy telephone or radio communication. In addition, loud-speakers more easily understood in presence of high background noise.

Weinstein, Leonard M.↗

Faraday rotation fluctutation spectra observed during solar occultation of the Helios spacecraft

Faraday rotation (FR) measurements using linearly polarized radio signals from the two Helios spacecraft were carried out during the period from 1975 to 1984. This paper presents the results of a spectral analysis of the Helios S-band FR fluctuations observed at heliocentric distances from 2.6 to 15 solar radii during the superior conjunctions 1975-1983. The mean intensity of the FR fluctuations does not exceed the noise level for solar offsets greater than ca. 15 solar radii. The rms FR fluctuation amplitude increases rapidly as the radio ray path approaches the Sun, varying according to a power law (exponent: 2.85 +/- 0.15) at solar distances 4-12 solar radii. At distances inside 4 solar radii the increase is even steeper (exponent: 5.6 +/- 0.2). The equivalent two-dimensional FR fluctuation spectrum is well modeled by a single power-law over the frequency range from 5 to 50 mHz. For heliocentric distances larger than 4 solar radii the spectral index varies between 1.1 and 1.6 with a mean value of 1.4 +/- 0.2, corresponding to a 3-D spectral index p = 2.4. FR fluctuations thus display a somwhat lower spectral index compared with phase and amplitude fluctuations. Surprisingly high values of the spectral index were found for measurements inside 4 solar radii (p = 2.9 +/- 0.2). This may arise from the increasingly dominant effect of the magnetic field on radio wave propagation at small solar offsets. Finally, a quasiperiodic component, believed to be associated with Alfven waves, was discovered in some (but not all!) fluctuation spectra observed simultaneously at two ground stations. Characteristic periods and bulk velocities of this component were 240 +/- 30 sec and 300 +/- 60 km/s, respectively.

Andreev, V.↗

Calibration and Performance of Juno Radio Science Data

Juno Radio Science measures the frequency of X- and Ka-band radio links between the Juno spacecraft and the Earth-based observing stations of NASA’s Deep Space Network (DSN) in order to determine the gravitational field of Jupiter. The received frequency contains information on the gravitational field and is also perturbed by the propagation environment, including Earth troposphere and ionosphere, electrons in the solar plasma, electrons in the Io Plasma Torus around Jupiter, and instrumental effects on both the spacecraft and the ground electronics. Each of these effects must be calibrated out of the data to ensure an accurate estimation of the Jupiter gravitational field. This work discusses the data processing, calibration, and performance of the frequency measurements. The precision of the frequency measurements average 1.1 mHz (1σ standard deviation at 60 second integration time), or 5.3 microns/sec in units of velocity. The remaining noise sources are primarily from residual troposphere and charged particles. Further improvement could be made in future radio science experiments with the addition of a cross-link and stiffer ground antennas.

Buccino, Dustin R↗

Calibration and Performance of Juno Radio Science Data

Juno Radio Science measures the frequency of X- and Ka-band radio links between the Juno spacecraft and the Earth-based observing stations of NASA’s Deep Space Network (DSN) in order to determine the gravitational field of Jupiter. The received frequency contains information on the gravitational field and is also perturbed by the propagation environment, including Earth troposphere and ionosphere, electrons in the solar plasma, electrons in the Io Plasma Torus around Jupiter, and instrumental effects on both the spacecraft and the ground electronics. Each of these effects must be calibrated out of the data to ensure an accurate estimation of the Jupiter gravitational field. This work discusses the data processing, calibration, and performance of the frequency measurements. The precision of the frequency measurements average 1.1 mHz (1σ standard deviation at 60 second integration time), or 5.3 microns/sec in units of velocity. The remaining noise sources are primarily from residual troposphere and charged particles. Further improvement could be made in future radio science experiments with the addition of a cross-link and stiffer ground antennas.

Oudrhiri, Kamal↗

Experimental investigation of outdoor propagation of finite-amplitude noise

The outdoor propagation of finite amplitude acoustic waves was investigated using a conventional electroacoustic transmitter which was mounted on the ground and pointed upward in order to avoid ground reflection effects. The propagation path was parallel to a radio tower 85 m tall, whose elevator carried the receiving microphone. The observations and conclusions are as follows: (1) At the higher source levels nonlinear propagation distortion caused a strong generation of high frequency noise over the propagation path. For example, at 70 m for a frequency 2-3 octaves above the source noise band, the measured noise was up to 30 dB higher than the linear theory prediction. (2) The generation occurred in both the nearfield and the farfield of the transmitter. (3) At no measurement point was small-signal behavior established for the high requency noise. Calculations support the contention that the nonlinearity generated high frequency noise never becomes small-signal in its behavior, regardless of distance. (4) When measured spectra are scaled in frequency and level to make them comparable with spectra of actual jet noise, they are found to be well within the jet noise range. It is therefore entirely possible that nonlinear distortion affects jet noise.

Webster, D. A.↗

Low-noise room-temperature and cryogenic mixers for 80-120 GHz

A description is given of two new mixers designed to operate in the 80-120-GHz range on 36-ft radio telescope. It is shown that for a hard-driven diode the parasitic resistance and capacitance are the primary factors influencing the design of the diode mount. A room-temperature mixer is described which achieves a single-sideband (SSB) conversion loss (L) of 5.5 dB, and a SSB noise temperature (Tm) of 500 K (excluding the IF contribution) with a 1.4-GHz IF. A cryogenically cooled version, using a quartz structure to support the diode chip and contact whisker, achieves values of L = 5.8 dB and Tm = 300 K with a 4.75-GHz IF. The mixers use high-quality Schottky-barrier diodes in a one-quarter-height waveguide mount.

Kerr, A. R.↗