Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION LENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Development of a Low-Level Ar-37 Calibration Standard

Argon-37 is an important environmental signature of an underground nuclear explosion. Producing and quantifying low-level 37Ar standards is an important step in the development of sensitive field measurement instruments for use during an On-Site Inspection, a key provision of the Comprehensive Nuclear-Test-Ban Treaty. This paper describes progress at Pacific Northwest National Laboratory (PNNL) in the development of a process to generate and quantify low-level 37Ar standard material, which can then be used to calibrate sensitive field systems at activities consistent with soil background levels. The 37Ar used for our work was generated using a laboratory-scale, high-energy neutron source to irradiate powdered samples of calcium carbonate. Small aliquots of 37Ar were then extracted from the head space of the irradiated samples. The specific activity of the head space samples, mixed with P10 (90% stable argon:10% methane by mole fraction) count gas, is then derived using the accepted Length-Compensated Internal-Source Proportional Counting method. Due to the low activity of the samples, a set of three Ultra-Low Background Proportional-Counters designed and fabricated at PNNL from radio-pure electroformed copper was used to make the measurements in PNNL’s shallow underground counting laboratory. Very low background levels (<10 counts/day) have been observed in the spectral region near the 37Ar emission feature at 2.8 keV. Two separate samples from the same irradiation were measured. The first sample was counted for 12 days beginning 28 days after irradiation, the second sample was counted for 24 days beginning 70 days after irradiation (the half-life of 37Ar is 35.0 days). Both sets of measurements were analyzed and yielded very similar results for the starting activity (~0.1 Bq) and activity concentration (0.15 mBq/ccSTP argon) after P10 count gas was added. A detailed uncertainty model was developed based on the ISO Guide to the Expression of Uncertainty in Measurement. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.

Absolute radiation measurement↗

Interferometric bunch length measurements of 3 MeV picocoulomb electron beams

We report picosecond bunch length measurements using an interferometric method for a 3 MeV electron beam having bunch charge ranging from 1 to 14 pC. The method senses the single-cycle sub-terahertz (THz) pulse emitted by each electron bunch as coherent transition radiation which, in turn, is analyzed using a Michelson-type interferometer, forming an interferogram that is then processed to yield the nominal electron bunch length. This sub-THz coherent radiation intensity was measured using a quasi-optical detector (QOD) operated at room temperature. This experiment was quite challenging since the divergence angle of the sub-THz pulse emitted by the low-energy electron bunch exceeds ±10°, and its pulse energy at the entrance to the detector was as low as 100 pJ. When compared to a conventional helium-cooled silicon composite bolometer designed for frequencies above 0.5 THz, the QOD provided much better signal-to-noise ratio in the ~80 GHz frequency range, which was critical for the successful measurement of the bunch length.

36 MATERIALS SCIENCE↗

A Novel Technique for Performing Space Based Radiation Dosimetry Using DNA: Results from GRaDEx-I and the Design of GRaDEx-II

Because of the large amounts of cosmic radiation in the space environment relative to that on earth, the effects of radiation on the physiology of astronauts is of major concern. Doses of radiation which can cause acute or chronic biological effects are to be avoided, therefore determination of the amount of radiation exposure encountered during space flight and assessment of its impact on biological systems is critical. Quantifying the radiation dosage and damage to biological systems, especially to humans during repetitive high altitude flight and during long duration space flight is important for several reasons. Radiation can cause altered biosynthesis and long term genotoxicity resulting in cancer and birth defects, etc. Radiation damage to biological systems depends in a complex way on incident radiation species and their energy spectra. Typically non-biological, i.e. film or electronic monitoring systems with narrow energy band sensitivity are used to perform dosimetry and then results are extrapolated to biological models. For this reason it may be desirable to perform radiation dosimetry by using biological molecules e.g. DNA or RNA strands as passive sensors. A lightweight genotoxicology experiment was constructed to determine the degree to which in-vitro naked DNA extracted from tissues of a variety of vertebrate organisms is damaged by exposure to radiation in a space environment. The DNA is assayed by means of agarose gel electrophoresis to determine damage such as strand breakage caused by high momentum particles and photons, and base oxidation caused by free radicals. The length distribution of DNA fragments is directly correlated with the radiation dose. It is hoped that a low mass, low cost, passive biological system to determine dose-response relationship (increase in strand breaks with increase in exposure) can be developed to perform radiation dosimetry in support of long duration space flight, and to predict negative effects on biological systems (e.g. astronauts and greenhouses) in space. The payload was flown in a 2.5 cubic foot Get Away Special (GAS) container through NASA's GAS program. It was subjected to the environment of the space shuttle cargo bay for the duration of the STS-91 mission (9 days). Results of the genotoxicology and radiation dosimetry experiment (GRaDEx-I) as well as the design of an improved follow on payload are presented.

Ritter, Joe↗

A Novel Technique for Performing Space Based Radiation Dosimetry Using DNA-Results from GRaDEx-I and the Design of GRaDEx-II

Because of the large amounts of cosmic radiation in the space environment relative to that on earth, the effects of radiation on the physiology of astronauts is of major concern. Doses of radiation which can cause acute or chronic biological effects are to be avoided, therefore determination of the amount of radiation exposure encountered during space flight and assessment of its impact on biological systems is critical. Quantifying the radiation dosage and damage to biological systems, especially to humans during repetitive high altitude flight and during long duration space flight is important for several reasons. Radiation can cause altered biosynthesis and long term genotoxicity resulting in cancer and birth defects etc. Radiation damage to biological systems depends in a complex way on incident radiation species and their energy spectra. Typically non-biological, i.e. film or electronic monitoring systems with narrow energy band sensitivity are used to perform dosimetry and then results are extrapolated to biological models. For this reason it may be desirable to perform radiation dosimetry by using biological molecules e.g. DNA or RNA strands as passive sensors. A lightweight genotoxicology experiment was constructed to determine the degree to which in vitro naked DNA extracted from tissues of a variety of vertebrate organisms is damaged by exposure to radiation in a space environment. The DNA is assayed by means of agarose gel electrophoresis to determine damage such as strand breakage caused by high momentum particles and photons, and base oxidation caused by free radicals. The length distribution of DNA fragments is directly correlated with the radiation dose. It is hoped that a low mass, low cost, passive biological system to determine dose response relationship (increase in strand breaks with increase in exposure) can be developed to perform radiation dosimetry in support of long duration space flight, and to predict negative effects on biological systems (e.g. astronauts and greenhouses) in space. The payload was flown in a 2.5 cubic foot Get Away Special (GAS) container through NASA's GAS program. It was subjected to the environment of the space shuttle cargo bay for the duration of the STS-91 mission (9 days). Results of the genotoxicology and radiation dosimetry experiment (GRaDEx-1) as well as the design of an improved follow on payload are presented.

Ritter, Joe↗

Transport properties of single-walled carbon nanotube transistors after gamma radiation treatment

Single-walled carbon nanotube field-effect transistors (CNT-FETs) were characterized before and after gamma radiation treatment using noise spectroscopy. The results obtained demonstrate that in long channel CNT-FETs with a length of 10 {mu}m the contribution of contact regions can be neglected. Moreover, radiation treatment with doses of 1x10{sup 6} and 2x10{sup 6} rad allows a considerable decrease parallel to the nanotube parasitic conductivity and even the shift region with maximal conductivity to the voltage range of nearly zero gate voltage that improves the working point of the FETs. The Hooge parameters obtained before and after gamma radiation treatment with a dose of 1x10{sup 6} rad are found to be about 5x10{sup -3}. The parameters are comparable with typical values for conventional semiconductors.

36 MATERIALS SCIENCE↗

SU-F-J-48: Effect of Scan Length On Magnitude of Imaging Dose in KV CBCT

Purpose: To study effect of scan length on magnitude of imaging dose deposition in Varian kV CBCT for head & neck and pelvis CBCT. Methods: To study effect of scan length we measured imaging dose at depth of 8 cm for head and neck Cone Beam Computed Tomography (CBCT) acquisition ( X ray beam energy is used 100kV and 200 degree of gantry rotation) and at 16 cm depth for pelvis CBCT acquisition ( X ray beam energy used is 125 kV and 360 degree of gantry rotation) in specially designed phantom. We used farmer chamber which was calibrated in kV X ray range for measurements .Dose was measured with default field size, and reducing field size along y direction to 10 cm and 5 cm. Results: As the energy of the beam decreases the scattered radiation increases and this contributes significantly to the dose deposited in the patient. By reducing the scan length to 10 Cm from default 20.6 cm we found a dose reduction of 14% for head and neck CBCT protocol and a reduction of 26% for pelvis CBCT protocol. Similarly for a scan length of 5cm compared to default the dose reduction in head and neck CBCT protocol is 36% while in the pelvis CBCT protocol the dose reduction is 50%. Conclusion: By limiting the scan length we can control the scatter radiation generated and hence the dose to the patient. However the variation in dose reduction for same length used in two protocols is because of the scan geometry. The pelvis CBCT protocol uses a full rotation and head and neck CBCT protocol uses partial rotation.

60 APPLIED LIFE SCIENCES↗

Ablation of biological tissues by radiation of strontium vapor laser

A two-stage laser system consisting of a master oscillator and a power amplifier based on sources of self- contained transitions in pairs SrI and SrII has been developed. The radiation spectrum contains 8 laser lines generating in the range of 1 – 6.45 μm, with a generation pulse length of 50 – 150 ns, and pulse energy of ∼ 2.5 mJ. The divergence of the output beam was close to the diffraction and did not exceed 0.5 mrad. The control range of the laser pulse repetition rate varied from 10 to 15 000 Hz. The given laser system has allowed to perform ablation of bone tissue samples without visible thermal damage.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effective defect diffusion lengths in Ar-ion bombarded 3C-SiC

Above room temperature, SiC exhibits pronounced processes of diffusion and interaction of radiation-generated point defects. Here, we use the recently developed pulsed ion beam method to measure effective defect diffusion lengths in 3C-SiC bombarded in the temperature range of 25–200 °C with 500 keV Ar ions. Results reveal a diffusion length of ~10 nm, which exhibits a weak temperature dependence, changing from 9 to 13 nm with increasing temperature. Lastly, these results have important implications for understanding and predicting radiation damage in SiC and for the development of radiation-resistant materials via interface-mediated defect reactions.

36 MATERIALS SCIENCE↗

High Performance Circularly Polarized Microstrip Antenna

A microstrip antenna for radiating circularly polarized electromagnetic waves comprising a cluster array of at least four microstrip radiator elements, each of which is provided with dual orthogonal coplanar feeds in phase quadrature relation achieved by connection to an asymmetric T-junction power divider impedance notched at resonance. The dual fed circularly polarized reference element is positioned with its axis at a 45 deg angle with respect to the unit cell axis. The other three dual fed elements in the unit cell are positioned and fed with a coplanar feed structure with sequential rotation and phasing to enhance the axial ratio and impedance matching performance over a wide bandwidth. The centers of the radiator elements are disposed at the corners of a square with each side of a length d in the range of 0.7 to 0.9 times the free space wavelength of the antenna radiation and the radiator elements reside in a square unit cell area of sides equal to 2d and thereby permit the array to be used as a phased array antenna for electronic scanning and is realizable in a high temperature superconducting thin film material for high efficiency.

Bondyopadhyay, Probir K.↗

Multipole interaction in spectral line broadening by plasmas

A long-standing ambiguity in spectral line broadening theory related to the electric field divergence in the quadrupole term of the screened Coulomb radiator-plasma interaction is examined. This is accomplished with multipole expansions from a Taylor series as well as a partial wave analysis of the screened Coulomb interaction. Here, it is explicitly shown that the two approaches agree up to the octupole term for an effective radiator size small compared to the plasma screening length. Furthermore, the ambigous corrections are confirmed appearing naturally in both methods. For higher multipoles the agreement is demonstrated numerically with a computer program using exact arithmetic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gridded daily weather data for North America with comprehensive uncertainty quantification

Abstract Access to daily high-resolution gridded surface weather data based on direct observations and over long time periods is essential for many studies and applications including vegetation, wildlife, soil health, hydrological modelling, and as driver data in Earth system models. We present Daymet V4, a 40-year daily meteorological dataset on a 1 km grid for North America, Hawaii, and Puerto Rico, providing temperature, precipitation, shortwave radiation, vapor pressure, snow water equivalent, and day length. The dataset includes an objective quantification of uncertainty based on strict cross-validation analysis for temperature and precipitation results. The dataset represents several improvements from a previous version, and this data descriptor provides complete documentation for updated methods. Improvements include: reductions in the timing bias of input reporting weather station measurements; improvement to the three-dimensional regression model techniques in the core algorithm; and a novel approach to handling high elevation temperature measurement biases. We show cross-validation analyses with the underlying weather station data to demonstrate the technical validity of new dataset generation methods, and to quantify improved accuracy.

54 ENVIRONMENTAL SCIENCES↗

Measurement of coherence length and incoherent source size of hard x-ray undulator beamline at Pohang Light Source-II

We measured the spatial coherence length and incoherent source size of a hard x-ray undulator beamline at Pohang Light Source-II, the stored electron energy of which has been increased from 2.5 GeV to 3 GeV. The coherence length was determined by single-slit measurement of the visibility of the Fresnel diffraction pattern. The correlated incoherent source size was cross-checked for three different optics: the single slit, beryllium parabolic compound refractive lenses, and the Fresnel zone plate. We concluded that the undulator beamline has an effective incoherent source size (FWHM) of 540 μm (horizontal) × 50 μm (vertical)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of electron current extraction from a radio frequency plasma cathode designed as a neutralizer for ion source applications

Plasma cathodes are insert free devices that are developed to be employed as electron sources in electric propulsion and ion source applications as practical alternatives to more commonly used hollow cathodes. Inductively coupled plasma cathodes, or Radio Frequency (RF) plasma cathodes, are introduced in recent years. Because of its compact geometry, and simple and efficient plasma generation, RF plasma source is considered to be suitable for plasma cathode applications. In this study, numerous RF plasma cathodes have been designed and manufactured. Experimental measurements have been conducted to study the effects of geometric and operational parameters. Experimental results of this study show that the plasma generation and electron extraction characteristics of the RF plasma cathode device strongly depend on the geometric parameters such as chamber diameter, chamber length, orifice diameter, orifice length, as well as the operational parameters such as RF power and gas mass flow rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a high efficiency relativistic backward wave oscillator with low guiding magnetic field

A high efficiency relativistic backward wave oscillator working at a low guiding magnetic field is designed and simulated. A trapezoidal resonant reflector is used to reduce the modulation field in the resonant reflector to avoid overmodulation of the electron beam which will lead to a large momentum spread and then low conversion efficiency. The envelope of the inner radius of the slow wave structure (SWS) increases stepwise to keep conformal to the trajectory of the electron beam which will alleviate the bombardment of the electron on the surface of the SWS. The length of period of the SWS is reduced gradually to make a better match between phase velocity and electron beam, which decelerates continually and improves the RF current distribution. Meanwhile the modulation field is reduced by the introduction of nonuniform SWS also. The particle in cell simulation results reveal that a microwave with a power of 1.8 GW and a frequency of 14.7 GHz is generated with an efficiency of 47% when the diode voltage is 620 kV, the beam current 6.1 kA, and the guiding magnetic field 0.95 T.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single and double photoionization of Ne 8+

A direct solution of the time-dependent Dirac equation is used to calculate the single and double photoionization cross sections for Ne 8+ . Expansion of a two-electron wavefunction in coupled spin–orbit eigenfunctions yields time-dependent close-coupled equations for quad-spinor radial wavefunctions. The repulsive interaction between electrons includes both Coulomb and Gaunt interactions. The fully-correlated ground state radial wavefunction is obtained by solving a time-independent inhomogeneous set of close-coupled equations instead of a relaxation of the time-dependent close-coupled equations in imaginary time. A Bessel function expansion is used to include both dipole and quadrupole effects in the radiation field interaction for both the ‘velocity’ and ‘length’ gauges. Propagation of the time-dependent close-coupled equations in real time yields single and double photoionization cross sections for Ne 8+ at energies easily accessible at advanced free electron laser facilities.

74 ATOMIC AND MOLECULAR PHYSICS↗

Delayed reheating and the breakdown of coherent oscillations

We analyze the evolution of the perturbations in the inflaton field and metric following the end of inflation. We present accurate analytic approximations for the perturbations, showing that the coherent oscillations of the post-inflationary condensate necessarily break down long before any current phenomenological constraints require the universe to become radiation dominated. Further, the breakdown occurs on length-scales equivalent to the comoving post-inflationary horizon size. This work has implications for both the inflationary ''matching'' problem, and the possible generation of a stochastic gravitational wave background in the post-inflationary universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic diffusion effects on the ultra-high energy cosmic ray spectrum and composition

We discuss the effects of diffusion of high energy cosmic rays in turbulent extra-galactic magnetic fields. We find an approximate expression for the low energy suppression of the spectrum of the different mass components (with charge Z) in the case in which this suppression happens at energies below ∼ Z EeV, so that energy losses are dominated by the adiabatic ones. The low energy suppression appears when cosmic rays from the closest sources take a time comparable to the age of the Universe to reach the Earth. This occurs for energies E < Z EeV (B/nG)√(l{sub c}/Mpc)(d{sub s}/70Mpc) in terms of the magnetic field RMS strength B, its coherence length l{sub c} and the typical separation between sources d{sub s}. We apply this to scenarios in which the sources produce a mixed composition and have a relatively low maximum rigidity (E{sub max} ∼ (2–10)Z EeV), finding that diffusion has a significant effect on the resulting spectrum, the average mass and on its spread, in particular reducing this last one. For reasonable values of B and l{sub c} these effects can help to reproduce the composition trends observed by the Auger Collaboration for source spectra compatible with Fermi acceleration.

79 ASTRONOMY AND ASTROPHYSICS↗