Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Measurements of the Υ ( 10860 ) and Υ ( 11020 ) resonances via σ ( e + e - → Υ ( n S ) π + π - )

In this work, we report new measurements of the total cross sections for e + e - → Υ ( n S ) π + π - ( n = 1 , 2, 3) and e + e - → b b ¯ from a high-luminosity fine scan of the region s = 10.63 – 11.05 GeV with the Belle detector. We observe that the Υ ( n S ) π + π - spectra have little or no nonresonant component and extract from them the masses and widths of Υ ( 10860 ) and Υ ( 11020 ) and their relative phase. We find M 10860 = ( 10891.1 ± 3. 2 - 1.7 + 0.6 ) MeV / c 2 and Γ 10860 = ( 53. 7 - 5.6 - 5.4 + 7.1 + 1.3 ) MeV and report first measurements M 11020 = ( 10987. 5 - 2.5 - 2.1 + 6.4 + 9.0 ) MeV / c 2 , Γ 11020 = ( 6 1 - 19 - 20 + 9 + 2 ) MeV , and Φ 11020 - Φ 10860 = ( - 1.0 ± 0.4 - 0.1 + 1.4 ) rad .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low Emittance, High Brilliance Relativistic Electron Beams from a Laser-Plasma Accelerator

Progress in laser wakefield accelerators indicates their suitability as a driver of compact free-electron lasers (FELs). High brightness is defined by the normalized transverse emittance, which should be less than 1{pi} mm mrad for an x-ray FEL. We report high-resolution measurements of the emittance of 125 MeV, monoenergetic beams from a wakefield accelerator. An emittance as low as 1.1{+-}0.1{pi} mm mrad is measured using a pepper-pot mask. This sets an upper limit on the emittance, which is comparable with conventional linear accelerators. A peak transverse brightness of 5x10{sup 15} A m{sup -1} rad{sup -1} makes it suitable for compact XUV FELs.

43 PARTICLE ACCELERATORS↗

Demonstration of Ignition Radiation Temperatures in Indirect-Drive Inertial Confinement Fusion Hohlraums

We demonstrate the hohlraum radiation temperature and symmetry required for ignition-scale inertial confinement fusion capsule implosions. Cryogenic gas-filled hohlraums with 2.2 mm-diameter capsules are heated with unprecedented laser energies of 1.2 MJ delivered by 192 ultraviolet laser beams on the National Ignition Facility. Laser backscatter measurements show that these hohlraums absorb 87% to 91% of the incident laser power resulting in peak radiation temperatures of T{sub RAD}=300 eV and a symmetric implosion to a 100 {mu}m diameter hot core.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-similar structure and experimental signatures of suprathermal ion distribution in inertial confinement fusion implosions

The distribution function of suprathermal ions is found to be self-similar under conditions relevant to inertial confinement fusion hot spots. By utilizing this feature, interference between the hydrodynamic instabilities and kinetic effects is for the first time assessed quantitatively to find that the instabilities substantially aggravate the fusion reactivity reduction. Thus, the ion tail depletion is also shown to lower the experimentally inferred ion temperature, a novel kinetic effect that may explain the discrepancy between the exploding pusher experiments and rad-hydro simulations and contribute to the observation that temperature inferred from DD reaction products is lower than from DT at the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of C P Violation in B 0 → D + D – Decays

The CP violation observables S and C in the decay channel B 0 →D + D – are determined from a sample of proton-proton collisions at center-of-mass energies of 7 and 8 TeV, collected by the LHCb experiment and corresponding to an integrated luminosity of 3 fb –1 . The observable S describes CP violation in the interference between mixing and the decay amplitude, and C parametrizes direct CP violation in the decay. The following values are obtained from a flavor-tagged, decay-time-dependent analysis: S = –0.54 +0.17 –0.16 (stat)±0.05(syst), C = 0.26 +0.18 –0.17 (stat)±0.02(syst). These values provide evidence for CP violation at a significance level of 4.0 standard deviations. The phase shift due to higher-order standard model corrections is constrained to a small value of ΔΦ = –0.16 +0.19 –0.21 rad.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental Demonstration of a Cheap and Accurate Phase Estimation

We demonstrate an experimental implementation of robust phase estimation (RPE) to learn the phase of a single-qubit rotation on a trapped Yb + ion qubit. Here, we show this phase can be estimated with an uncertainty below 4 × 10 -4 rad using as few as 176 total experimental samples, and our estimates exhibit Heisenberg scaling. Unlike standard phase estimation protocols, RPE neither assumes perfect state preparation and measurement, nor requires access to ancillae. We crossvalidate the results of RPE with the more resource-intensive protocol of gate set tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved Measurement of C P Violation Parameters in B s 0 → J / ψ K + K − Decays in the Vicinity of the ϕ ( 1020 ) Resonance

The decay-time-dependent C P asymmetry in B s 0 → J / ψ ( → μ + μ − ) K + K − decays is measured using proton-proton collision data, corresponding to an integrated luminosity of 6 fb − 1 , collected with the LHCb detector at a center-of-mass energy of 13 TeV. Using a sample of approximately 349 000 B s 0 signal decays with an invariant K + K − mass in the vicinity of the ϕ ( 1020 ) resonance, the C P -violating phase ϕ s is measured, along with the difference in decay widths of the light and heavy mass eigenstates of the B s 0 − B ¯ s 0 system, Δ Γ s , and the difference of the average B s 0 and B 0 meson decay widths, Γ s − Γ d . The values obtained are ϕ s = − 0.039 ± 0.022 ± 0.006 rad , Δ Γ s = 0.0845 ± 0.0044 ± 0.0024 ps − 1 , and Γ s − Γ d = − 0.005 6 − 0.0015 + 0.0013 ± 0.0014 ps − 1 , where the first uncertainty is statistical and the second systematic. These are the most precise single measurements to date and are consistent with expectations based on the Standard Model and with the previous LHCb analyses of this decay. These results are combined with previous independent LHCb measurements. The phase ϕ s is also measured independently for each polarization state of the K + K − system and shows no evidence for polarization dependence. © 2024 CERN, for the LHCb Collaboration 2024 CERN

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Harnessing Plasmonic Interference for Nanoscale Ultrafast Electron Sources

In this Letter we demonstrate the use of plasmonic focusing in conjunction with nonlinear photoemission to develop geometrically flat nanoscale electron sources with less than 40 pm-rad root mean squared (rms) normalized transverse emittance. Circularly polarized light is incident on a gold Archimedean spiral structure to generate surface-plasmon polaritons that interfere coherently at the center resulting in a 50 nm rms emission area. Furthermore, such a nanostructured flat surface enables simultaneous spatiotemporal confinement of emitted electrons at the nanometer and femtosecond level and can be used as an advanced electron source for high-repetition-rate ultrafast electron diffraction and microscopy experiments as well as the next generation of miniaturized particle accelerators.

43 PARTICLE ACCELERATORS↗

Optimizing MeV photon dose generation in laser-solid interactions via stable beam propagation

Bremsstrahlung MeV x rays with high doses are essential for radiography of dense objects. Intense, short-pulse laser-driven MeV x-ray sources offer a promising solution, but understanding how the dose scales with laser intensity is crucial for their development. While theory predicts a square root scaling with laser intensity, experimental verification has been hindered by significant shot-to-shot variations, often exacerbated by long preplasma scale lengths from low laser contrast. Here, we demonstrate low shot-to-shot dose variation and confirm the theoretical scaling using high-contrast OMEGA EP laser interactions with millimeter-thick tantalum foils, achieving MeV x-ray doses up to 5.4 rad at 1 m for E photon > 500 keV. Simulations reveal that the unique focal spot of the OMEGA EP laser enables efficient x-ray generation and reduced variability by facilitating deeper laser penetration into dense plasma, even with shorter preplasma scale lengths. Published by the American Physical Society 2025

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation-driven rotational motion of nanoparticles

Focused synchrotron beams can influence a studied sample via heating, or radiation pressure effects due to intensity gradients. The high angular sensitivity of rotational X-ray tracking of crystalline particles via their Bragg reflections can detect extremely small forces such as those caused by field gradients. By tracking the rotational motion of single-crystal nanoparticles embedded in a viscous or viscoelastic medium, the effects of heating in a uniform gradient beam and radiation pressure in a Gaussian profile beam were observed. Changes in viscosity due to X-ray heating were measured for 42 µm crystals in glycerol, and angular velocities of 10 −6 rad s −1 due to torques of 10 −24 N m were measured for 340 nm crystals in a colloidal gel matrix. These results show the ability to quantify small forces using rotation motion of tracer particles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FMX – the Frontier Microfocusing Macromolecular Crystallography Beamline at the National Synchrotron Light Source II

Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425 , 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493 , 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015 , 1741 , 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 × 10 12 photons s −1 at 1 Å into a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 10 12 photons s −1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods – serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25 , 1362–1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ , 5 , 238–246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5 , 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IRIXS Spectrograph: an ultra high-resolution spectrometer for tender RIXS

The IRIXS Spectrograph represents a new design of an ultra-high-resolution resonant inelastic X-ray scattering (RIXS) spectrometer that operates at the Ru L 3 -edge (2840 eV). First proposed in the field of hard X-rays by Shvyd'ko [(2015), Phys. Rev. A, 91, 053817], the X-ray spectrograph uses a combination of laterally graded multilayer mirrors and collimating/dispersing Ge(111) crystals optics in a novel spectral imaging approach to overcome the energy resolution limitation of a traditional Rowland-type spectrometer [Gretarsson et al. (2020), J. Synchrotron Rad. 27, 538–544]. In combination with a dispersionless nested four-bounce high-resolution monochromator design that utilizes Si(111) and Al 2 O 3 (110) crystals, an overall energy resolution better than 35 meV full width at half-maximum has been achieved at the Ru L 3 -edge, in excellent agreement with ray-tracing simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of source emittance and beam coherence properties of the upgraded Advanced Photon Source

The Advanced Photon Source (APS) has been upgraded with a multi-bend achromat lattice, achieving significantly reduced electron beam emittance and enhanced X-ray coherence. Precise characterization of these properties is essential for optimizing beamline performance and enabling new experiments that take full advantage of the upgraded source. We report on measurements of source size and transverse coherence properties using grating interferometry at two beamlines: the APS 3-ID-B undulator beamline and the 1-BM-B bending magnet beamline. The results confirm the world-record horizontal emittance of the upgraded APS below 30 pm rad and validate the theoretical design parameters. We further investigate the impact of optical aberrations and mechanical vibrations at the 12-ID-C beamline on coherence preservation. These measurements establish a benchmark for future beamline enhancements and demonstrate the effectiveness of grating interferometry for high-precision beam characterization. Our findings provide critical insights into synchrotron beam dynamics, coherence degradation mechanisms, and strategies for optimizing beamline X-ray optics at next-generation light sources.

Advanced Photon Source↗

Analysis of multicrystal pump–probe data sets. I. Expressions for the RATIO model

The RATIO method in time-resolved crystallography [Coppens et al. (2009). J. Synchrotron Rad. 16 , 226–230] was developed for use with Laue pump–probe diffraction data to avoid complex corrections due to wavelength dependence of the intensities. The application of the RATIO method in processing/analysis prior to structure refinement requires an appropriate ratio model for modeling the light response. The assessment of the accuracy of pump–probe time-resolved structure refinements based on the observed ratios was discussed in a previous paper. In the current paper, a detailed ratio model is discussed, taking into account both geometric and thermal light-induced changes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental development of rod pinch diode radiographic source using modified KALI 1000 pulsed power system

This paper highlights the development of Rod Pinch (RP) diode for flash X-ray generation as intense radiographic source at BARC, Vizag. The typical RP diode employed used a small diameter (1-2 mm) anode rod extended through a cathode circular aperture (5-6 mm inner diameter). The diode chamber is maintained at 10{sup -5} Torr vacuum by a rotary backed diffusion pump. Experiments performed on a modified Kali 1000 Pulsed Power System (300 kV, 30 kA, 100 ns) were aimed at optimizing the source by maximizing the figure of merit (dose @ 1m in rad/spot diameter{sup 2} in mm{sup 2}) with minimizing of the diode impedance. The typical electron beam parameters used in the experiments are 240-270 kV, 20-25 kA, 100 ns, with a few hundreds of kA/cm{sup 2} current density. The optimization resulted in a configuration with tungsten anode rod having dimensions of a 1.6 mm diameter, tapering extension length 5-25 mm beyond the graphite cathode aperture (Cathode disk ID = 5 mm, thickness = 3mm) to produce a radiation dose of 150-200 milli rad at 1 m distance having an estimated spot-size of 1-2 mm. The radiation emitted from a rod-pinch diode is measured using Thermoluminescence dosimeters (TLDs) at an angular interval of 15° on either side of the rod in horizontal and vertical plane. (author)

43 PARTICLE ACCELERATORS↗

Optical Detection of Phase-Resolved Ferromagnetic Resonance in Epitaxial FeCo Thin Films

We report phased-resolved ferromagnetic resonance (FMR) measurements in an epitaxial Fe50Co50 thin film using a heterodyne, optical detection method. We track the evolution of the precessional phase across the saturated and unsaturated regimes along the FeCo hard axis. For the two regimes, opposite phase evolutions with frequency are observed, which coincide with the negative effective field dependence on the biasing field for the unsaturated modes. In addition, a nonzero phase advance between 0.2 and 0.4 rad is found for the saturated with respect to the unsaturated modes, which indicates an incomplete spatial overlap of the two modes in the film caused by surface pinning effect. The optical method has the advantage of resolving both the spatial and phase information in FMR measurements, which will be closely relevant and adaptable to epitaxial samples with multiple anisotropy axes, and for both flip-chip-based continuous films and spin-torque-based nano-devices.

36 MATERIALS SCIENCE↗

Simulation and Modeling of Time-Resolved X-Ray Detector for the Saturn Accelerator

In this work, we present the technology-aided computer design (TCAD) device simulation and modeling of a silicon p-i-n diode for detecting time-dependent X-ray radiation. We show that the simulated forward and reverse breakdown current–voltage characteristics agree well with the measured data under nonradiation environment by only calibrating carrier lifetimes for the forward bias case and avalanche model critical fields for the reverse bias condition. Using the calibrated parameters and other nominal material properties, we simulated the radiation responses of the p-i-n diode and compared with experimental data when the diode was exposed to X-ray radiation at Sandia’s Saturn facility and the Idaho State University (ISU) TriMeV facility. For Saturn’s Gaussian dose-rate pulses, we show three findings from TCAD simulations. First, the simulated photocurrents are in excellent agreement with the measured data for two dose-rate pulses with peak values of 1.16×10 10 and 1.88×10 10 rad(Si)/s. Second, the simulation results of high dose-rate pulses predict increased delayed photocurrents with longer time tails in the diode electrical responses due to excess carrier generation. Third, simulated peak values of diode radiation responses versus peak dose rates at different bias conditions provide useful guidance to determine the dose-rate range that the p-i-n diode can reliably detect in experiment. For TriMeV’s non-Gaussian dose-rate pulse, our simulated diode response is in decent agreement with the measured data without further calibration. We also studied the effects of device geometry, recombination process, and dose-rate enhancement via TCAD simulations to understand the higher measured response in the time after the peak dose-rate radiation for the p-i-n diode exposed to TriMeV irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗