Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Quantification of retained austenite by X-ray diffraction and saturation magnetization in a supermartensitic stainless steel

The good performance of supermartensitic stainless steels is strongly dependent on the volume fraction of retained austenite at room temperature. The present work investigates the effect of secondary tempering temperatures on this phase transformation and quantifies the amount of retained austenite by X-ray diffraction and saturation magnetization. The steel samples were tempered for 1 h within a temperature range of 600–800 °C. The microstructure was characterized using scanning electron microscopy and electron backscatter diffraction. Results show that the amount of retained austenite decreased with increasing secondary tempering temperature in both quantification methods. - Highlights: • The phase transformation during secondary tempering temperatures was observed. • Phases were quantified by X-ray diffraction and DC-saturation magnetization. • More retained austenite forms with increasing secondary tempering temperature. • The retained austenite is mainly located at the grain and lath boundaries.

36 MATERIALS SCIENCE↗

Indentation size effect in tungsten: Quantification of geometrically necessary dislocations underneath the indentations using HR-EBSD

Highlights: • Revealed the dislocation structure below nanoindentations via ECCI and HR-EBSD. • Experimentally quantification of GND densities, with higher GND densities at lower depths. • Qualitative validation of the Nix-Gao model on the indentation size effect. - Abstract: During indentation testing of the low defect density crystalline materials, higher hardness values are found at lower indentation depths, which is referred to as an indentation size effect. The depth-dependence of hardness can be described by the Nix-Gao model, which is based on the concept of Geometrically Necessary Dislocations (GNDs). The underlying dislocation mechanism remains, however, unclear and requires independent measurement of GND density below the indentation. In the present work, the depth-dependency of the GND density is quantified underneath the Berkovich indentations in tungsten via high-resolution electron backscatter diffraction. There a higher GND density is found for lower indentation depths, resulting in a higher Taylor hardness for measured GND density.

36 MATERIALS SCIENCE↗

Uncertainty quantification for competing failure mechanisms in unidirectionally reinforced carbon–carbon composites

Microstructure-informed finite element models play a key role in the carbon–carbon composite design process. Variability in manufacturing process parameters and experimental limitations introduce model parameter uncertainty. This study quantifies the effect of model parameter uncertainty on transverse tensile fracture behavior and proposes a methodology to predict the failure mode based on competing microscale damage mechanisms. Finite element simulations incorporate fiber–matrix interface debonding with cohesive zones and matrix damage with a smeared crack band approach in a unidirectional carbon–carbon composite. Results from a variance-based global sensitivity analysis identifies interfacial and matrix damage parameters as the primary source of variability in fracture behavior. Sobol’ indices indicate that matrix and cohesive zone strengths contribute 94% of the variance in the effective ultimate stress. A local analysis elucidates the relationship between these constituent strength parameters and failure mode by estimating the probability of cohesive, matrix, and mixed-mode dominated failure. Based on the results for 4000 simulations, 93% exhibit mixed-mode or interfacial dominated failure, which underscores the crucial role of fiber–matrix interface debonding in the transverse tensile failure of carbon–carbon composites. These uncertainty quantification results facilitate more efficient model calibration and provide a framework for microstructure-informed failure predictions in the face of manufacturing-induced uncertainty.

36 MATERIALS SCIENCE↗

Uncertainty Quantification, Sensitivity Analysis, and Data Assimilation for Nuclear Systems Simulation

Reliable evaluation of nuclear data will play a major role in reduction of nuclear systems simulation uncertainties via the use of advanced sensitivity analysis (SA), uncertainty quantification (UQ), and data assimilation (DA) methodologies. This follows since nuclear data have proven to constitute a major source of neutronics uncertainties. This paper will overview the use of the Efficient Subspace Method (ESM), developed at NCSU, to overcome one of the main deficiencies of existing methodologies for SA/UQ/DA, that is the ability to handle codes with large input and output (I/O) data streams, where neither the forward nor the adjoint approach alone are appropriate. We demonstrate the functionality of ESM for an LWR core, a boiling water reactor, and a fast reactor benchmark experiment, the ZPR6/7A assembly. This work demonstrates the capability of adjusting cross section data thereby providing guidance to cross section evaluation efforts by identification of key cross sections and associated energy ranges that contribute the most to the propagated core attributes uncertainties.

99 GENERAL AND MISCELLANEOUS↗

Subspace-based Inverse Uncertainty Quantification for Nuclear Data Assessment

Safety analysis and design optimization depend on the accurate prediction of various reactor attributes. Predictions can be enhanced by reducing the uncertainty associated with the attributes of interest. An inverse problem can be defined and solved to assess the sources of uncertainty, and experimental effort can be subsequently directed to further improve the uncertainty associated with these sources. In this work a subspace-based algorithm for inverse sensitivity/uncertainty quantification (IS/UQ) has been developed to enable analysts account for all sources of nuclear data uncertainties in support of target accuracy assessment-type analysis. An approximate analytical solution of the optimization problem is used to guide the search for the dominant uncertainty subspace. By limiting the search to a subspace, the degrees of freedom available for the optimization search are significantly reduced. A quarter PWR fuel assembly is modeled and the accuracy of the multiplication factor and the fission reaction rate are used as reactor attributes whose uncertainties are to be reduced. Numerical experiments are used to demonstrate the computational efficiency of the proposed algorithm. Our ongoing work is focusing on extending the proposed algorithm to account for various forms of feedback, e.g., thermal-hydraulics and depletion effects.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Inventory Uncertainty Quantification using TENDL Covariance Data in Fispact-II

The new inventory code Fispact-II provides predictions of inventory, radiological quantities and their uncertainties using nuclear data covariance information. Central to the method is a novel fast pathways search algorithm using directed graphs. The pathways output provides (1) an aid to identifying important reactions, (2) fast estimates of uncertainties, (3) reduced models that retain important nuclides and reactions for use in the code's Monte Carlo sensitivity analysis module. Described are the methods that are being implemented for improving uncertainty predictions, quantification and propagation using the covariance data that the recent nuclear data libraries contain. In the TENDL library, above the upper energy of the resolved resonance range, a Monte Carlo method in which the covariance data come from uncertainties of the nuclear model calculations is used. The nuclear data files are read directly by FISPACT-II without any further intermediate processing. Variance and covariance data are processed and used by FISPACT-II to compute uncertainties in collapsed cross sections, and these are in turn used to predict uncertainties in inventories and all derived radiological data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quality Quantification of Evaluated Cross Section Covariances

Presently, several methods are used to estimate the covariance matrix of evaluated nuclear cross sections. Because the resulting covariance matrices can be different according to the method used and according to the assumptions of the method, we propose a general and objective approach to quantify the quality of the covariance estimation for evaluated cross sections. The first step consists in defining an objective criterion. The second step is computation of the criterion. In this paper the Kullback-Leibler distance is proposed for the quality quantification of a covariance matrix estimation and its inverse. It is based on the distance to the true covariance matrix. A method based on the bootstrap is presented for the estimation of this criterion, which can be applied with most methods for covariance matrix estimation and without the knowledge of the true covariance matrix. The full approach is illustrated on the {sup 85}Rb nucleus evaluations and the results are then used for a discussion on scoring and Monte Carlo approaches for covariance matrix estimation of the cross section evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Water Calibration Measurements for Neutron Radiography: Application to Water Content Quantification in Porous Media

Using neutron radiography, the measurement of water thickness was performed using aluminum (Al) water calibration cells at the High Flux Isotope Reactor (HFIR) Cold-Guide (CG) 1D neutron imaging facility at Oak Ridge National Laboratory, Oak Ridge, TN, USA. Calibration of water thickness is an important step to accurately measure water contents in samples of interest. Neutron attenuation by water does not vary linearly with thickness mainly due to beam hardening and scattering effects. Transmission measurements for known water thicknesses in water calibration cells allow proper correction of the underestimation of water content due to these effects. As anticipated, strong scattering effects were observed for water thicknesses greater than 2 mm when the water calibration cells were positioned close to the face of the detector / scintillator (0 and 2.4 cm away, respectively). The water calibration cells were also positioned 24 cm away from the detector face. These measurements resulted in less scattering and this position (designated as the sample position) was used for the subsequent experimental determination of the neutron attenuation coefficient for water. Neutron radiographic images of moist Flint sand in rectangular and cylindrical containers acquired at the sample position were used to demonstrate the applicability of the water calibration. Cumulative changes in the water volumes within the sand columns during monotonic drainage determined by neutron radiography were compared with those recorded by direct reading from a burette connected to a hanging water column. In general, the neutron radiography data showed very good agreement with those obtained volumetrically using the hanging water-column method. These results allow extension of the calibration equation to the quantification of unknown water contents within other samples of porous media.

Kang, Misun↗

Simulation of a TRISO MiniFuel irradiation experiment with data-informed uncertainty quantification

An irradiation experiment using tristructural isotropic (TRISO) fuel particles and the miniature fuel (MiniFuel) irradiation vehicle was performed in Oak Ridge National Laboratory’s High Flux Isotope Reactor (HFIR) to support development of the Kairos Power fluoride salt–cooled, high-temperature reactor (KP-FHR). Here, this paper describes modeling predictions of temperatures and fuel burnup for the as-built experiment. An uncertainty quantification (UQ) analysis was performed to determine the effect of TRISO particle volume and position on the temperature predictions at various fuel heat generation rates (HGRs). This UQ study utilized fuel kernel position and volume measurements previously collected using X-ray computed tomography (XCT) techniques and Monte Carlo sampling methods to generate fuel compact cases that were then analyzed using a finite element thermal model. The UQ analysis indicated that uncertainty in calculated temperatures caused by varying TRISO particle arrangement is relatively small, even at high fuel HGR. Final predictions of particle temperatures throughout the irradiation are shown to be relevant to KP-FHR normal and off-normal operating conditions and to previous TRISO irradiation experiments. The combination of XCT with UQ analyses will inform post-irradiation examination (PIE) of the irradiated fuel compacts, and these analyses can be used to develop fuel performance models for coated particle fuel forms. Both PIE of separate-effects irradiation data and enhanced fuel performance modeling support accelerated qualification of TRISO fuels for a broad range of advanced reactor applications. The novel approach demonstrated here of measuring TRISO particle configurations with XCT methods and generating representative fuel compacts for finite element modeling and UQ analysis could be leveraged by the broader particle fuel community in the development of other TRISO fuel experiments in which these variables may have a significant impact on key outcomes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An automated isotope identification and quantification algorithm for isotope mixtures in low-resolution gamma-ray spectra

There is a need to develop an automated isotope identification and quantification algorithm that can perform well using low-resolution gamma-ray detectors. The algorithm should be able to perform well on spectra that contain a mixture of many isotopes as well as in cases where spectral features are difficult to analyze. Due to the low resolution of these detectors, spectra of isotope mixtures becomes complicated to identify when features overlap. Previous research applying machine learning algorithms to isotope identification has been promising. Further work is needed to demonstrate the limits of machine learning algorithms when applied to identifying mixtures of isotopes and spectra where features are not obvious. Because machine learning algorithms use abstract features of the spectrum, such as the shape of overlapping peaks and Compton continuum, they are a natural choice for analyzing isotope mixtures. In this work, an artificial neural network (ANN) has be trained to calculate the relative activities of 29 isotopes in a spectrum. The ANN is trained with simulated gamma-ray spectra, allowing custom datasets to be generated for specific identification tasks. The algorithms performance on simulated spectra without apparent features and on simulated isotope mixtures are both analyzed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Physics-informed machine learning assisted uncertainty quantification for the corrosion of dissimilar material joints

Jointing techniques like the Self-Piercing Riveting (SPR), Resistance Spot Welding (RSW) and Rivet-Weld (RW) joints are used for mass production of dissimilar material joints due to their high performance, short cycle time, and adaptability. However, the service life and safety usage of these joints can be largely impacted by the galvanic corrosion due to the difference in equilibrium potentials between the metals with the presence of electrolyte. Here, in this paper, we focus on Al-Fe galvanic corrosion and develop physics-informed machine learning based surrogate model for statistical corrosion analysis, which enables the reliability analysis of dissimilar material joints under corrosion environment. In this study, a physics-based finite element (FE) corrosion model has been developed to simulate the galvanic corrosion between a Fe cathode and an Al anode. Geometric and environmental factors including crevice gap, roughness of anode, conductivity, and the temperature of the electrolyte are investigated. Further, a thorough Uncertainty Quantification (UQ) analysis is conducted for the overall corrosion behavior of the Fe-Al joints. It is found that the electrolyte conductivity has the largest effects on the material loss and needs to be managed closely for better corrosion control. This will help in designing and manufacturing joints with improved corrosion performance.

42 ENGINEERING↗

Ensemble methods for quantification of potassium oxide in ChemCam Mars and laboratory spectra

In this paper we test new approaches for predicting the amount of element oxides in rock samples from the ChemCam instrument suite onboard the NASA Curiosity rover by focusing on K 2 O. Using the expanded dataset compiled by Gasda et al. (2021) with and without the Earth to Mars (E2M and NoE2M) transformation discussed in Clegg et al. (2017) we trained blended submodels using the “double blending” technique and compared these to ensemble methods (Random Forest, ExtraTrees, and Gradient Boosting Regression). We found that ensemble methods performed similar to blended submodels when looking at RMSE-P on the laboratory spectra and provided significant advantages when looking at spectra coming from Mars. For the full model, blended submodels achieved an RMSE-P of 0.62 and 0.60 (E2M and NoE2M respectively) while Gradient Boosting Regression resulted in a slightly improved RMSE-P of 0.59 and 0.60. More importantly, by employing a local RMSE-P estimation technique where model performance is evaluated based on nearby test samples we found that using ensemble methods can lower the quantification limit for K 2 O from the current value of ≈0.6 wt% to ≈0.08 wt% using Extra Trees and Random Forest. This would allow for a much larger range of K 2 O values to be quantified on Mars with greater certainty given that most targets seen on Mars tend to have <1 wt% K2O. Finally, we used both Mean Decrease in Impurity (MDI) and permutation importance techniques to investigate the wavelengths used by the ensemble methods and found that they correspond to known potassium emission lines. This suggests that ensemble methods can provide an easier to train and improved alternative to blended submodels for predicting potassium compositions from Laser Induced Breakdown Spectroscopy (LIBS) data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methodology for quantification of waste generated in Spanish railway construction works

Highlights: Black-Right-Pointing-Pointer Two equations for C and D waste estimation in railway construction works are developed. Black-Right-Pointing-Pointer Mixed C and D waste is the most generated category during railway construction works. Black-Right-Pointing-Pointer Tunnel construction is essential to quantify the waste generated during the works. Black-Right-Pointing-Pointer There is a relationship between C and D waste generated and railway functional units. Black-Right-Pointing-Pointer The methodology proposed can be used to obtain new constants for other areas. - Abstract: In the last years, the European Union (EU) has been focused on the reduction of construction and demolition (C and D) waste. Specifically, in 2006, Spain generated roughly 47 million tons of C and D waste, of which only 13.6% was recycled. This situation has lead to the drawing up of many regulations on C and D waste during the past years forcing EU countries to include new measures for waste prevention and recycling. Among these measures, the mandatory obligation to quantify the C and D waste expected to be originated during a construction project is mandated. However, limited data is available on civil engineering projects. Therefore, the aim of this research study is to improve C and D waste management in railway projects, by developing a model for C and D waste quantification. For this purpose, we develop two equations which estimate in advance the amount, both in weight and volume, of the C and D waste likely to be generated in railway construction projects, including the category of C and D waste generated for the entire project.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantification of greenhouse gas emissions from a biological waste treatment facility

Highlights: • Whole-site fugitive emissions were measured at a biowaste treatment facility. • Methane and nitrous oxide were quantified using a tracer gas dispersion technique. •The daily average whole-site methane emission was 25.6 kg CH{sub 4} h{sup −1}. • Whole-site fugitive emissions were up to eight times higher than on-site emissions. • The emissions had a significant influence on the overall environmental impact - Abstract: Whole-site emissions of methane and nitrous oxide, from a combined dry anaerobic digestion and composting facility treating biowaste, were quantified using a tracer dispersion technique that combines a controlled tracer gas release from the treatment facility with time-resolved concentration measurements downwind of the facility. Emission measurements were conducted over a period of three days, and in total, 80 plume traverses were obtained. On-site screening showed that important processes resulting in methane emissions were aerobic composting reactors, anaerobic digester reactors, composting windrows and the site’s biofilter. Average whole-site methane emissions measured during the three days were 27.5 ± 7.4, 28.5 ± 6.1 and 30.1 ± 11.4 kg CH{sub 4} h{sup −1}, respectively. Turning the windrows resulted in an increase in methane emission from about 26.3–35.9 kg CH{sub 4} h{sup −1}. Lower emissions (21.5 kg CH{sub 4} h{sup −1}) were measured after work hours ended, in comparison to emissions measured during the facility’s opening hours (30.2 kg CH{sub 4} h{sup −1}). Nitrous oxide emission was too small for a downwind quantification. Direct on-site measurements, however, suggested that the main part of the emitted nitrous oxide came from the biofilter (about 1.4 kg N{sub 2}O h{sup −1}). Whole-site emissions were compared to emissions previously measured at different point sources on-site. Whole-site fugitive emissions were three to eight times higher than the sum of emissions measured at on-site sources. The magnitude of the emissions had a significant influence on the overall environmental impact of the treatment facility, assessed by consequential life cycle assessment. Including the higher whole-site fugitive emissions led to an increase in global warming potential, from a saving of 97 kg CO{sub 2}-eq. tonne{sup −1} of treated waste (wet weight) to a loading of 71 kg CO{sub 2}-eq. tonne{sup −1}, ultimately flipping the environmental profile of the treatment facility.

09 BIOMASS FUELS↗

Integrated Lateral Flow Test Strip with Electrochemical Sensor for Quantification of Phosphorylated Cholinesterase: Biomarker of Exposure to Organophosphorus Agents

An integrated lateral flow test strip with electrochemical sensor (LFTSES) device with rapid, selective and sensitive response for quantification of exposure to organophosphorus (OP) pesticides and nerve agents has been developed. The principle of this approach is based on parallel measurements of post-exposure and baseline acetylcholinesterase (AChE) enzyme activity, where reactivation of the phosphorylated AChE is exploited to enable measurement of total amount of AChE (including inhibited and active) which is used as a baseline for calculation of AChE inhibition. Quantitative measurement of phosphorylated adduct (OP-AChE) was realized by subtracting the active AChE from the total amount of AChE. The proposed LFTSES device integrates immunochromatographic test strip technology with electrochemical measurement using a disposable screen printed electrode which is located under the test zone. It shows linear response between AChE enzyme activity and enzyme concentration from 0.05 to 10 nM, with detection limit of 0.02 nM. Based on this reactivation approach, the LFTSES device has been successfully applied for in vitro red blood cells inhibition studies using chlorpyrifos oxon as a model OP agent. This approach not only eliminates the difficulty in screening of low-dose OP exposure because of individual variation of normal AChE values, but also avoids the problem in overlapping substrate specificity with cholinesterases and avoids potential interference from other electroactive species in biological samples. It is baseline free and thus provides a rapid, sensitive, selective and inexpensive tool for in-field and point-of-care assessment of exposures to OP pesticides and nerve agents.

59 BASIC BIOLOGICAL SCIENCES↗

Long-Gradient Separations Coupled with Selected Reaction Monitoring for Highly Sensitive, Large Scale Targeted Protein Quantification in a Single Analysis

Long-gradient separations coupled to tandem MS were recently demonstrated to provide a deep proteome coverage for global proteomics; however, such long-gradient separations have not been explored for targeted proteomics. Herein, we investigate the potential performance of the long-gradient separations coupled with selected reaction monitoring (LG-SRM) for targeted protein quantification. Direct comparison of LG-SRM (5 h gradient) and conventional LC-SRM (45 min gradient) showed that the long-gradient separations significantly reduced background interference levels and provided an 8- to 100-fold improvement in LOQ for target proteins in human female serum. Based on at least one surrogate peptide per protein, an LOQ of 10 ng/mL was achieved for the two spiked proteins in non-depleted human serum. The LG-SRM detection of seven out of eight endogenous plasma proteins expressed at ng/mL or sub-ng/mL levels in clinical patient sera was also demonstrated. A correlation coefficient of >0.99 was observed for the results of LG-SRM and ELISA measurements for prostate-specific antigen (PSA) in selected patient sera. Further enhancement of LG-SRM sensitivity was achieved by applying front-end IgY14 immunoaffinity depletion. Besides improved sensitivity, LG-SRM offers at least 3 times higher multiplexing capacity than conventional LC-SRM due to ~3-fold increase in average peak widths for a 300-min gradient compared to a 45-min gradient. Therefore, LG-SRM holds great potential for bridging the gap between global and targeted proteomics due to its advantages in both sensitivity and multiplexing capacity.

Shi, Tujin↗

Electrochemical Branched-DNA Assay for Polymerase Chain Reaction-Free Detection and Quantification of Oncogenes in Messenger RNA

We describe a novel electrochemical branched-DNA (bDNA) assay for polymerase chain reaction (PCR)-free detection and quantification of p185 BCR-ABL leukemia fusion transcript in the population of messenger RNA (mRNA) extracted from cell lines. The bDNA amplifier carrying high loading of alkaline phosphatase (ALP) tracers was used to amplify targets signal. The targets were captured on microplate well surfaces through cooperative sandwich hybridization prior to the labeling of bDNA. The activity of captured ALP was monitored by square-wave voltammetric (SWV) analysis of the electroactive enzymatic product in the presence of 1-napthyl-phosphate. The specificity and sensitivity of assay enabled direct detection of target transcript in as little as 4.6 ng mRNA without PCR amplification. In combination with the use of a well-quantified standard, the electrochemical bDNA assay was capable of direct use for a PCR-free quantitative analysis of target transcript in total mRNA population. The approach thus provides a simple, sensitive, accurate and quantitative tool alternate to the RQ-PCR for early disease diagnosis.

59 BASIC BIOLOGICAL SCIENCES↗

Quantification of Technetium-99 in Complex Groundwater Matrixes using a Radiometric Preconcentrating Minicolumn Sensor in an Equilibration-based Sensing Approach

A preconcentrating minicolumn sensor for pertechnetate detection in water consists of a packed bed containing a mixture of anion exchange resin and scintillating plastic beads. The column materials are contained in a transparent plastic flow cell placed between two photomultiplier tubes for radiometric detection. Upon retention of pertechnetate anions, the radioactive decay of Tc-99 results in detectable scintillation pulses that are counted in coincidence. In equilibration-based sensing mode, the sample is pumped through the packed bed until complete chromatographic equilibrium is achieved between the activity concentration in the water sample and the concentration on the anion exchange resin. The analytical signal is the observed steady state count rate at equilibrium. The sensitivity is related to a measurement efficiency parameter that is the product of the retention volume and the absolute radiometric detection efficiency. This sensor can readily detect pertechnetate to levels ten times below the drinking water standard of 0.033 Bq/mL. The potential for other anions in natural groundwater and contaminated groundwater plumes to interfere with pertechnetate detection and quantification have been examined in detail, with reference to the groundwater chemistry at the Hanford Site in Washington State. Individual anions such as nitrate, carbonate, chloride and iodide, at natural or elevated concentrations, do not interfere significantly with pertechnetate uptake on the anion exchange resin. Elevated chromate or sulfate anion concentrations can interfere with pertechnetate uptake by the resin, but only at levels substantially higher than typical concentrations in groundwater or contamination plumes. Nevertheless, elevated anion concentrations may reduce pertechnetate uptake and sensitivity of the sensor when present in combination. Chromate is retained on the anion exchange resin from water at ppb levels, leading to an orange stain that interferes with pertechnetate detection by the absorption of scintillation light pulses (color quench). Radioactivity from radioiodine, tritium, and uranium are not expected to create a significant positive bias in groundwater analyses. A method of automated fluidic standard addition is demonstrated that corrects for matrix interferences leading to accurate analyses over a wide range of groundwater compositions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗