Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power distribution systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

DLMP of Competitive Markets in Active Distribution Networks: Models, Solutions, Applications, and Visions

Traditionally, the electric distribution system operates with uniform energy prices across all system nodes. However, as the adoption of distributed energy resources (DERs) propels a shift from passive to active distribution network (ADN) operation, a distribution-level electricity market has been proposed to manage new complexities efficiently. In addition, distribution locational marginal price (DLMP) has been established in the literature as the primary pricing mechanism. The DLMP inherits the LMP concept in the transmission-level wholesale market but incorporates characteristics of the distribution system, such as high $R/X$ ratios and power losses, system imbalance, and voltage regulation needs. The DLMP provides a solution that can be essential for competitive market operation in future distribution systems. This article first provides an overview of the current distribution-level market architectures and their early implementations. Next, the general clearing model, model relaxations, and DLMP formulation are comprehensively reviewed. The state-of-the-art solution methods for distribution market clearing are summarized and categorized into centralized, distributed, and decentralized methods. Then, DLMP applications for the operation and planning of DERs and distribution system operators (DSOs) are discussed in detail. Finally, visions of future research directions and possible barriers and challenges are presented.

42 ENGINEERING↗

Seasonal Reconfiguration of Electrical Distribution Systems to Mitigate the Impact of Electric Vehicle Charging

Power grids face challenges in their infrastructure related to the integration of electric vehicles (EV). In particular, EV charging stations may induce instability in key system parameters such as substantial voltage drops, active power losses, and transformer overload due to high demand during charging periods. This article presents a seasonal reconfiguration strategy based on the differential evolution (DE) algorithm, aimed at enhancing system performance under highly variable and stochastic load profiles, particularly those driven by EV charging. The DEA algorithm is hybridized with the find-union (FU) algorithm to efficiently ensure network radiality throughout the optimization process. The proposed methodology is validated on a hybrid distribution system composed of the IEEE 33-bus network, a modified IEEE 13-bus system, and a specific 13-bus microgrid. Results have demonstrated that seasonal reconfiguration significantly reduces active power losses and mitigates transformer loading during critical demand hours, thereby quantifiably increasing the system’s performance. As an integral component of the proposed approach, an analysis of CO2 emissions associated with energy losses is included, allowing a contextualized assessment of the environmental benefits of seasonal reconfiguration in various geographical areas.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Energy Dispatch of Distributed PVs for the Next Generation of Distribution Management Systems

Advanced Distribution Management Systems (ADMS) are being widely adopted by electric utilities for managing and optimizing the operations of their distribution systems. Distributed photovoltaic (DPV) systems with smart inverters can be controlled to adjust active power and reactive power outputs, and they are envisioned to become a part of (centrally or distributed) controllable assets managed by the ADMS for optimizing grid operations. This paper proposes an optimal energy dispatch strategy controlling DPV systems for regulating distribution voltages and achieving conservation voltage reduction. A convex optimization model is proposed with the use of linearized power flow, and the gradient projection algorithm is used to solve the optimal active power and reactive power outputs of smart inverters. The proposed optimal energy dispatch is implemented using an open-source ADMS platform, and simulation results have demonstrated the effectiveness of the proposed approach on improving distribution grid operations.

42 ENGINEERING↗

Extracting Resilience Metrics From Distribution Utility Data Using Outage and Restore Process Statistics

Resilience curves track the accumulation and restoration of outages during an event on an electric distribution grid. We show that a resilience curve generated from utility data can always be decomposed into an outage process and a restore process and that these processes generally overlap in time. We use many events in real utility data to characterize the statistics of these processes, and derive formulas based on these statistics for resilience metrics such as restore duration, customer hours not served, and outage and restore rates. The formulas express the mean value of these metrics as a function of the number of outages in the event. We also give a formula for the variability of restore duration, which allows us to predict a maximum restore duration with 95% confidence. Overall, we give a simple and general way to decompose resilience curves into outage and restore processes and then show how to use these processes to extract resilience metrics from standard distribution system data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data: Preprint

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Characterizing Current THD’s Dependency on Solar Irradiance and Supraharmonics Profiling for a Grid-Tied Photovoltaic Power Plant

The rapidly increasing distributed energy resources (DERs) in power systems are now getting interconnected to set community grid structures, where power quality will be a major concern. The grid-to-grid (G2G) bidirectional power transfer among the distribution microgrid will not be considered commercially feasible unless the upstream harmonics are under the limits. The aggregation of such harmonics, measured as total harmonic distortion (THD), is feared to be beyond tolerable limits with the progression of rooftop grid-tied PV-like installations. Hence, this THD needs to be characterized with DER generation end variables. In this work, the photovoltaic (PV) DERs’ dependency on environment variables such as irradiance was profiled in the context of generating and injecting harmonics into the grid. A mathematical model of a grid-tied three-phase PV DER was developed as part of this correlation characterization, matching the fundamental unit structure of a 1.4 MW solar canopy located on the Florida International University (FIU) Miami campus. To determine the qualitative association with produced THD patterns, the model was evaluated with various irradiance settings. A real-time digital simulation (RTDS) platform was used to verify it. Following this confirmation, sets of data from power quality meters at the point of common coupling and FIU field sensors were utilized to validate further the correlation model. The results showed that the grid current’s THD exhibited a high correlation with the irradiance profile and its variation over time. The early morning and late afternoon periods of the day, associated with a low irradiance, constantly had higher harmonics generated from the PV DER. The midday THD was rather rational with partial shadings, hence a geolocation-dependent factor. These findings were verified by an RTDS and validated by real field data. In quantifying the THD injected by a single DER at a high-frequency (2–150 kHz) supraharmonics (SH) level, a 3% peak increment in magnitude was observed from the high-fixed to the low-fixed irradiance profile. The correlation characteristics depicted that the hybrid microgrid suffered from a daytime-dependent harmonic insertion from the grid-tied DER. This is a global problem unless specific measures are taken to mitigate the harmonics. The electrically notorious higher-frequency SH was found to increase proportionally. The G2G power transfer can be limited because of the higher THD in the early morning and late afternoon, which will also worsen because the numbers of grid-tied PV DERs (i.e., rooftop solar and industrial solar) are likely to increase rapidly soon. The community grid structure can thus have a controlled harmonics filtration setup purposefully designed to address the findings of this work, which also fall within the scope of our future research.

14 SOLAR ENERGY↗

A Relaxed PV Bus Model in Linear Power Flow

The emerging multimodal active energy resource units make it necessary to introduce constant voltage amplitude buses (PV bus) in the operation of modern distribution systems. To enable the analysis of PV bus using linear power flow models, this letter proposes a relaxed PV bus model for solving power flow related problems using an indirect modeling approach. The developed PV bus model can be applied to linear power flow models in both rectangular and polar coordinates. Besides, the approximation error of the relaxed PV bus model can also be controlled and quantified. Lastly, the proposed relaxed PV bus model is validated using different test systems. According to the numerical studies, the maximum error on the PV bus approximation in all case studies is only 0.61%, and the maximum error of the supporting power at the PV buses is 6.5%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Emergency Voltage Regulation in Power Systems via Ripple-Type Control

With increasing penetrations of volatile renewable generation and cyber-physical disruptions, ensuring the safe operation of bulk power systems has become unprecedentedly challenging. Because communication and computational costs restrict centralized system dispatch to being called upon every few minutes, and because purely local schemes are shown to be insufficient, distributed controls have been advocated for handling unanticipated system conditions in real time. The applicability of distributed control schemes, however, is fundamentally limited by their need for widespread communication and model cognizance. In this context, we put forth a hybrid, low-communication, saturation-driven protocol for the coordination of control agents that are distributed over a physical system and are allowed to communicate with peers over a "hotline" communication network. Under this protocol, when agents observe a constraint violation based on local measurements, they respond locally until their control resources saturate, in which case they send a beacon for assistance to peer agents. The scheme ensures that minor violations are efficiently mitigated via fast local controls, whereas severe violations can be handled by collaboration among a relatively small set of agents. We evaluate the performance of this scheme via numerical tests on the IEEE 14-bus test feeder, where agents act upon noisy measurements under diverse scenarios of load variations and severe low-/high-voltage events.

collaboration↗

Multidisciplinary Design, Analysis, and Optimization (MDO) for Co-Designed Transmission & Distribution Electric Grid Planning

This paper describes early experiences and example use cases applying multi-disciplinary design analysis and optimization (MDO) to the integrated design of power grids. Adapted from aerospace, MDO enables combining multiple existing tools into a coordinated optimization. Here we use MDO to simultaneously capture integrated transmission-distribution and investment-engineering trade-offs in an automated framework. Example use cases showcase prototype interactions among existing grid models using MDO and hint at the types of integrated analyses enabled by this approach. In addition, we share experiences and thoughts on grid-specific challenges and opportunities to help advance further work in this area.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Fast and Scalable Genetic Algorithm-Based Approach for Planning of Microgrids in Distribution Networks: Preprint

As a result of climate change, extreme weather events are occurring more frequently and with increasing impact. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks; thus, the level of proactive preparation of the distribution system to be able to handle severe impacts of extreme weather events represents the system's resilience. One method that distribution systems use to prepare for extreme events is to form multiple microgrids and thereby isolate themselves from the grid supply by using local generation as much as possible to supply critical loads. But partitioning an existing system into multiple feasible islands capable of supporting critical loads is still challenging for distribution systems - first, because of the size of the graph partitioning problem and, second, because of the difficulty in properly formulating the desired attributes of such islands or microgrids. Therefore, this paper presents a genetic algorithmbased approach that facilitates incorporating multiple objectives for grid partitioning by formulating two types of problems - node allocation and edge elimination - and it considers multiple topological and resilience-enhancing objectives. The performance of the proposed genetic algorithm-based approach is numerically evaluated on multiple test systems as well as on a real distribution feeder in Colorado, USA.

edge elimination↗

Modeling of Grid-Forming and Grid-Following Inverters for Dynamic Simulation of Large-Scale Distribution Systems

Historically, distribution system planning studies mainly focused on steady state and quasi-steady state analysis, with limited attention paid to dynamic analysis. This paper develops three-phase, electromechanical models for both grid-forming and grid-following inverters, and integrates them into an open source, three-phase distribution network solver, thereby enabling dynamic simulation of large-scale, three-phase unbalanced distribution systems with high penetration of inverter-based DERs. The proposed inverter models are validated against electromagnetic simulation and field test data from the CERTS/AEP microgrid testbed, and simulated in an islanded 5252 node distribution system in the GridLAB-D simulation environment. Simulation verifies the effectiveness of the proposed inverter models for large-scale distribution system analysis. Finally, study results show that compared to traditional grid-following inverters, the high penetration of grid-forming inverters can improve the voltage and frequency stability of islanded distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Volt-VAR Optimization in Distribution Networks Using Twin Delayed Deep Reinforcement Learning

Modern distribution grids are undergoing new challenges due to the stochastic nature of distributed energy resources (DERs). High penetration of DERs has a significant impact on Volt-VAR profile and system power losses. This work proposes a deep reinforcement learning (DRL)-based Volt-VAR optimization approach for improving voltage profile and reducing system power loss under high penetration of distributed energy resources, such as battery energy storage and solar photovoltaic units in distribution grids. The twin delayed deep deterministic policy gradient (TD3) method-based DRL agent is proposed to configure optimal set-points of reactive power outputs of fast responding smart inverters. The agent schedules the reactive power of inverters according to their physical capabilities, such as minimum allowed power factor, e.g., 0.9 leading/lagging. The reward function of the proposed DRL scheme is designed carefully to ensure a proper voltage profile of the grids with effective scheduling of reactive power outputs from inverters. The performance of the proposed model is verified on modified IEEE 34- and 123-bus systems and compared with base case with no reactive supply by inverters, and local droop Volt-VAR control approach. The results show that the proposed method performs better than the local droop control and deep deterministic policy gradient (DDPG)-based DRL method for reducing voltage fluctuation and minimizing power loss.

Hossain, Rakib↗

Autonomous Intelligence Measurements and Sensor Systems (AIMS): Gaussian Processes in Remote Sensing: Literature Review

Power grid resilience and reliability is crucial to supporting critical infrastructure. Service interruptions can have devastating consequences to communication, emergency, and transportation services, just to name a few. In addition to infrastructure, power services are crucial to everyday life. Nearly every element of modern-day living relies on a stable and functioning power grid - heating and cooling systems to lighting, refrigeration, telecommunications, and internet access. Interruptions in the power supply can range from minor inconveniences, such as the temporary loss of internet or television services, to more significant problems, like the inability to access medical equipment or emergency services during critical situations. As climate conditions worsen, the reliability of the power grid becomes even more significant. Extreme weather events, such as hurricanes, wildfires, or severe storms, can cause serious damage to power infrastructure, leading to prolonged power outages. Rising temperatures and changing weather patterns can strain the grid, resulting in increased demand for electricity, stressing transmission and distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗