Harvesting Wave Energy to Power Acoustic Transmitters Using Triboelectric Nanogenerator

Wave energy has the largest reserves and widest distribution among blue energy sources. However, the conversion and utilization of ocean wave energy are challenging. In this work, we developed a contact-separation mode triboelectric nanogenerator (TENG) with a simple structure for harvesting wave energy and powering marine sensors and transmitters and performed detailed electrical characterization under controlled laboratory conditions. A prototype power management circuit (PMC) was implemented to improve the output performance of the TENG. The output from the PMC could charge up a storage capacitor for powering sensors and electronics. Eventually, the TENG was integrated within a water-proof enclosure and tested using a custom-built wave simulator to evaluate the device performance in a more representative scenario. The device sustainably powered up an array of 27 LEDs and was able to charge up a capacitor up to 1.8 V for driving an acoustic transmitter. The results demonstrate that TENG technology shows great promise in harvesting low-frequency ocean wave energy.

Yang, Yang↗

Riemannian Optimization Applied to AC Optimal Power Flow: Preprint

The nonlinear, nonconvex AC optimal power flow problem is of growing importance as the nature of the power grid evolves. This problem can be difficult to solve for interior point methods. However, the advent of optimization algorithms over smooth Riemannian manifolds presents an alternative approach. The nonlinear, nonconvex constraints in the AC power flow problem form an embedded submanifold of Euclidean space. In this paper, the authors explore the performance of Riemannian optimization algorithms for the ACOPF problem where the optimization is performed directly on the AC power flow manifold. They demonstrate that these are viable computational alternatives to interior point methods. This is done by using Julia and the packages PowerModels.jl and Manopt.jl.

manifold optimization↗

Examination of Semi-Analytical Solution Methods in the Coarse Operator of Parareal Algorithm for Power System Simulation

With continuing advances in high-performance parallel computing platforms, parallel algorithms have become powerful tools for development of faster than real-time power system dynamic simulations. In particular, it has been demonstrated in recent years that parallel-in-time (Parareal) algorithms have the potential to achieve such an ambitious goal. Here, the selection of a fast and reasonably accurate coarse operator of the Parareal algorithm is crucial for its effective utilization and performance. This paper examines semi-analytical solution (SAS) methods as the coarse operators of the Parareal algorithm and explores performance of the SAS methods to the standard numerical time integration methods. Two promising time-power series-based SAS methods were considered; Adomian decomposition method and Homotopy analysis method with a windowing approach for improving the convergence. Numerical performance case studies on 10-generator 39-bus system and 327-generator 2383-bus system were performed for these coarse operators over different disturbances, evaluating the number of Parareal iterations, computational time, and stability of convergence. All the coarse operators tested with different scenarios have converged to the same corresponding true solution (if they are convergent) and the SAS methods provide comparable computational speed, while having more stable convergence to the true solution in many cases.

97 MATHEMATICS AND COMPUTING↗

PWR Core Analysis for Cycle Extension and Uprates with LEU+ Accident Tolerant Fuel and 80 GWd/Tonne Burnup Limit

The U.S. Nuclear Regulatory Commission has recently drafted a rule enabling fuel burnup increase in light water reactors up to 80 GWd/t. In conjunction with use of fuel enrichment up to 10%, and accident tolerant fuel (ATF), this is anticipated to facilitate 24-month cycles in PWRs, along with further power uprates. In this paper, PWR core analysis is performed for 20% increased PWR power output along with cycle extension up to 24 months, in combination with use of chromia-doped fuel and chromium-coated clad, considered to be the most near-term ATF concepts. In combination, these lead to challenging conditions with a core average discharge burnup of up to ~74 GWd/t, challenging even the 80 GWd/t burnup limit. Analysis is performed using the 2-step method with POLARIS (within SCALE) used for the lattice calculations and PARCS for the core calculations. Core designs are first baselined for current operating conditions (LEU, 62 GWd/t discharge burnup limit) and then derived that meet cycle constraints on power distribution and the updated lead pin discharge burnup limit while maintaining at least two batches of fuel in the core. Gadolina loadings in fuel pins of up to 8% are used, with enrichment zoning both within the core and, to a limited extent, within assemblies. Here, doped fuel with coated cladding can utilize the same core designs as the reference UOX cores, exhibiting slightly lower burnup due to higher fuel density, which also offsets the slight reactivity penalty from the doping and coating. For the analysis performed here, doped fuel enabled a core with 24-month cycle and 20% uprate to stay within the 80 GWd/t lead pin discharge burnup limit.

LEU+↗

Tuning the electronic structure of Ag-Pd alloys to enhance performance for alkaline oxygen reduction

Alloying is a powerful tool that can improve the electrocatalytic performance and viability of diverse electrochemical renewable energy technologies. Herein, we enhance the activity of Pd-based electrocatalysts via Ag-Pd alloying while simultaneously lowering precious metal content in a broad-range compositional study focusing on highly comparable Ag-Pd thin films synthesized systematically via electron-beam physical vapor co-deposition. Cyclic voltammetry in 0.1 M KOH shows enhancements across a wide range of alloys; even slight alloying with Ag (e.g. Ag 0.1 Pd 0.9 ) leads to intrinsic activity enhancements up to 5-fold at 0.9 V vs. RHE compared to pure Pd. Based on density functional theory and x-ray absorption, we hypothesize that these enhancements arise mainly from ligand effects that optimize adsorbate–metal binding energies with enhanced Ag-Pd hybridization. This work shows the versatility of coupled experimental-theoretical methods in designing materials with specific and tunable properties and aids the development of highly active electrocatalysts with decreased precious-metal content.

25 ENERGY STORAGE↗

Evaluation of Distributed Power Apportioning with Net Load Management Engine in Microgrids Using Power Hardware-in-the-Loop Simulation

This article presents the performance evaluation of ratio consensus-based distributed power apportioning engine along with centralized net load management (NLM) engine that ensures viable and stable operation of an islanded microgrid. Managing net load variability in a microgrid with high penetrations of uncertain renewable generation and ever-changing load demands is a crucial need in order to ensure viable and stable operation of the microgrid. Centralized “dispatch-rule”-based and/or multi-agent-based distributed control of distributed energy resources (DERs) in microgrid are well accepted for microgrid by adapting ANSI/ISA-95-based hierarchical control architecture. In the application where microgrid network has large geographical span with multiple DERs dispersed in the network, high penetration of uncertain renewable energy resources, and ever-changing load demands, a judicious selection of techniques/solutions for managing net-load resources for maintaining viability and stability is required. With this motivation, this article proposes a novel solution to mitigate the challenges by incorporating a mixed centralized NLM engine and distributed power apportioning control of DERs and loads. A power-hardware-in-the-loop (PHIL) -based experiment is conducted with the centralized NLM engine and the distributed power apportioning engine along with two commercial inverters. The experimental results validates the efficacy of the proposed method in ensuring viability and stability of a microgrid.

hardware-in-the-loop simulation↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Performance CO 2 Capture from Air by Harnessing the Power of CaO- and Superbase-Ionic-Liquid-Engineered Sorbents

Direct air capture (DAC) of CO 2 by solid porous materials represents an attractive “negative emission” technology. However, state-of-the-art sorbents based on supported amines still suffer from unsolved high energy consumption and stability issues. For this work, taking clues from the CO 2 interaction with superbase-derived ionic liquids (SILs), high-performance and tunable sorbents in DAC of CO 2 was developed by harnessing the power of CaO- and SIL-engineered sorbents. Deploying mesoporous silica as the substrate, a thin CaO layer was first introduced to consume the surface-OH groups, and then active sites with different basicities (e. g., triazolate and imidazolate) were introduced as a uniformly distributed thin layer. The as-obtained sorbents displayed high CO 2 uptake capacity via volumetric (at 0.4 mbar) and breakthrough test (400 ppm CO 2 source), rapid interaction kinetics, facile CO 2 releasing, and stable sorption/desorption cycles. Operando diffuse reflectance infrared Fourier transformation spectroscopy (DRIFTS) analysis under simulated air atmosphere and solid-state NMR under 13 CO 2 atmosphere demonstrated the critical roles of the SIL species in low-concentration CO 2 capture. The fundamental insights obtained in this work provide guidance on the development of high-performance sorbents in DAC of CO 2 by leveraging the combined advantages of porous solid scaffolds and the unique features of CO 2 -philic ionic liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The cosmological evolution of self-interacting dark matter

We study the evolution of cosmological perturbations in dark-matter models with elastic and velocity-independent self interactions. Such interactions are imprinted in the matter-power spectrum as dark acoustic oscillations, which can be experimentally explored to determine the strength of the self scatterings. Models with self interactions have similarities to warm dark matter, as they lead to suppression of power on small scales when the dark-matter velocity dispersion is sizable. Nonetheless, both the physical origin and the extent of the suppression differ for self-interacting dark matter from conventional warm dark matter, with a dark sound horizon controlling the reduction of power in the former case, and a free-streaming length in the latter. We thoroughly analyze these differences by performing computations of the linear power spectrum using a newly developed Boltzmann code. We find that while current Lyman-α data disfavor conventional warm dark matter with a mass less than 5.3 keV, when self interactions are included at their maximal value consistent with bounds from the Bullet Cluster, the limits are relaxed to 4.4 keV. Lastly, we make use of our analysis to set novel bounds on light scalar singlet dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

National Ignition Facility 192 beam 3w power sensor

NIF requires additional laser diagnostic capabilities to support existing missions and drive performance of the laser to higher powers and energies. There exists a current gap in laser power data on the facility due to the subset of beamlines that are measurement capable. Additionally, as NIF increases the radiation yield on target experiments, the performance of the current laser diagnostic 3w power sensor system has been steadily decreasing. The degradation of the current system is not well understood and needs to be characterized to facilitate any new system design.

42 ENGINEERING↗

Modeling the effect of wind speed and direction shear on utility‐scale wind turbine power production

Abstract Wind speed and direction variations across the rotor affect power production. As utility‐scale turbines extend higher into the atmospheric boundary layer (ABL) with larger rotor diameters and hub heights, they increasingly encounter more complex wind speed and direction variations. We assess three models for power production that account for wind speed and direction shear. Two are based on actuator disc representations, and the third is a blade element representation. We also evaluate the predictions from a standard power curve model that has no knowledge of wind shear. The predictions from each model, driven by wind profile measurements from a profiling LiDAR, are compared to concurrent power measurements from an adjacent utility‐scale wind turbine. In the field measurements of the utility‐scale turbine, discrete combinations of speed and direction shear induce changes in power production of −19% to +34% relative to the turbine power curve for a given hub height wind speed. Positive speed shear generally corresponds to over‐performance and increasing magnitudes of direction shear to greater under‐performance, relative to the power curve. Overall, the blade element model produces both higher correlation and lower error relative to the other models, but its quantitative accuracy depends on induction and controller sub‐models. To further assess the influence of complex, non‐monotonic wind profiles, we also drive the models with best‐fit power law wind speed profiles and linear wind direction profiles. These idealized inputs produce qualitative and quantitative differences in power predictions from each model, demonstrating that time‐varying, non‐monotonic wind shear affects wind power production.

Energy & Fuels↗

A Medium Voltage Testbed for the Performance and Function Tests of a 13.8 kV Power Conditioning System Converter

Medium voltage SiC devices facilitate the development of medium voltage grid-connected power electronics converters. However, it is difficult to test these converters directly on the real medium voltage grid, especially considering abnormal grid conditions, such as grid voltage and frequency variation, and different converter operation modes, such as grid-connected mode and islanded mode. This paper introduces the design and implementation of a medium voltage testbed, which supports tests of medium voltage converters in both grid-connected and islanded mode tests. In the grid-connected mode, the testbed can provide up to 13.8 kV grid voltage, can support the four-quadrant operation, and can emulate different grid conditions, such as voltage and frequency variation. In the islanded mode, the converter under test works as a voltage source and the testbed emulates a three-phase balanced or unbalanced load. Experiment test results are provided to validate the design and capability of the testbed.

Li, Haiguo↗

Performance Comparison of Clipping Detection Techniques in AC Power Time Series

In this research, a variety of methods were developed to detect clipping periods in AC power time series. AC power data streams associated with 36 unique systems across the United States were collected, and data points representing clipping periods were manually labeled by experts. Using this data set for training and validation, novel logic-based and machine learning (ML) approaches were developed to classify time series values as clipping or non-clipping. These approaches were compared to the RdTools method for detecting clipping periods. The logic-based and ML XGBoost approaches achieved F-scores of 85.0 and 77.6, respectively, when cross-validated against the manually labeled data, as compared to the current RdTools approach (F-score of 56.4), indicating a significant improvement at detecting clipping periods. Additionally, the effects of each clipping filter when evaluating system degradation rates were assessed, using 31 unique systems across the United States. Results indicate that estimated system degradation rate can vary based on the type of clipping filter used, by up to 0.6% degradation rate for some cases.

clipping↗

Performance Comparison of Clipping Detection Techniques in AC Power Time Series: Preprint

In this research, a variety of methods were developed to detect clipping periods in AC power time series. Novel logic-based and machine learning (ML) approaches were developed to classify time series values as clipping or non-clipping. These approaches were compared to the RdTools method for detecting clipping periods. The logic-based and ML XGBoost approaches achieved F-scores of 82.6 and 74.4, respectively, as compared to the current RdTools approach (F-score of 56.4), indicating a significant improvement at detecting clipping periods. Additionally, the effects of using more accurate clipping filters when evaluating system degradation rates will be assessed in our final manuscript.

clipping↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998–2018

This report presents an enhanced performance evaluation of emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES) data from 1998 through 2018 and (2) maintenance unavailability (UA) performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2018. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in NRC probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. Engineering analyses were performed with respect to time period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed are: sub-component, failure cause, detection method, recovery, manufacturer, and EDG rating. A statistically significant increasing trend was identified in the frequency of FTLR demands for emergency power system (EPS) and high pressure core spray (HPCS) EDGs and a statistically significant decreasing trend was identified in the frequency of run > 1H hours for EPS and HPCS EDGs.

99 GENERAL AND MISCELLANEOUS↗