Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photon emission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Stellar Calibration of the WIC and SI Imagers and the GEO Photometers on IMAGE/FUV

The FUV instrument on the IMAGE spacecraft comprises three wide-field imagers, the Wide-Band Imaging Camera (WIC) of observing N2 Lyman-Birge-Hopfield (LBH) (140-190 nm) emissions and the Spectrographic Imager (SI), which has a 121.8 nm channel for observing red-shifted HI Lya photons and a 135.6 run channel for observing 01 135.6 nm emissions. In addition, three HI Lya photometers (GEO) are used to monitor the geocorona. The fields of view are 17 degrees x 17 degrees for the WIC imagers, 15 degrees x 15 degrees for the two SI imagers, and 10 diameter for the three GEO photometers. As the IMAGE spacecraft spins every 120 seconds, the GEO photometers sweep out circles on the sky (at 0 degrees and plus or minus 30 degrees with respect to the spacecraft spin plane), and the WIC and SI imagers use the Time Delay Integration (TDI) method to construct images centered on the Earth. Many FUV-bright stars are seen in the WIC, SI and even the GEO data. WE have used archived International Ultraviolet Explorer (IUE) far-ultraviolet flux spectra for 22 of the brightest of these stars to help refine the FUV instrumental sensitivities. The stars chosen range in spectral type form B0V to A11V, with magnitudes ranging from V- 1.3 (a Cru) to V=4.7 (G Cen) (although many more fainter stars are also seen). The initial results of this stellar calibration will be presented and compared with the pre-flight and dayglow modeling results.

Gladstone, R.↗

Tunable, Homoepitaxial Hyperbolic Metamaterials Enabled by High Mobility CdO

We report propagating light exhibits hyperbolicity in strongly anisotropic materials where the principal components of the dielectric tensor are opposite in sign. While hyperbolicity occurs naturally in anisotropic polar dielectrics, wherein optical phonons along orthogonal crystal axes are nondegenerate, such optical anisotropy can also be engineered in hyperbolic metamaterials (HMMs): thin film superlattices of alternating dielectric and metallic layers. Contrasted with the severely limited tunability of natural hyperbolic materials, the hyperbolic behavior of HMMs can be tailored significantly both through superlattice design and material selection. However, so far HMMs have suffered from high optical losses, hindering their performance. In this report, broadly tunable (λ = 2–5 µm) Type I and II hyperbolic modes with low losses (quality (Q)-factors up to 19.7) are observed through attenuated total reflectance measurements of monolithic, homoepitaxial superlattices of high- and low-doped cadmium oxide (CdO). Further, the low losses offered by CdO enable the first demonstration of real-space imaging of hyperbolic plasmon polaritons in nanoresonators by scattering-type scanning near-field optical microscopy—previously only possible for hyperbolic phonon polariton materials. Tunable, low-loss CdO HMMs promise designability for applications such as on-chip photonics, super-resolution imaging (hyperlensing), enhanced emission, novel emitter designs, and possibly quantum nanophotonic and time variant metasurfaces.

36 MATERIALS SCIENCE↗

Resonance Effect in Brunel Harmonic Generation in Thin Film Organic Semiconductors

Abstract Nonlinear optical properties of organic semiconductors (OSCs) have been extensively investigated in the perturbative regime, while strong light induced high‐order processes in solid‐state OSCs are less studied. Here, below‐threshold harmonic generation is examined, both experimentally and theoretically, in two solid‐state thin film OSCs, that is, tetraphenylporphyrin and zinc tetraphenylporphyrin. Results show that the π–π* excitations of the porphyrin ring system generate the harmonic emission. The contribution of the Brunel harmonic to the 5th harmonic emission is uncovered, where the resonant 5‐photon transition ( S 0 → S 2 transition) is found to lead to an early onset of non‐perturbative behavior. A similar resonance effect is expected in Brunel harmonic generation in other organic materials.

36 MATERIALS SCIENCE↗

Terahertz parametric amplification as a reporter of exciton condensate dynamics

Condensates are a hallmark of emergence in quantum materials with superconductors and charge density wave as prominent examples. An excitonic insulator (EI) is an intriguing addition to this library, exhibiting spontaneous condensation of electron-hole pairs. However, condensate observables can be obscured through parasitic coupling to the lattice. Time-resolved terahertz (THz) spectroscopy can disentangle such obscurants through measurement of the quantum dynamics. We target Ta 2 NiSe 5 , a putative room-temperature EI where electron-lattice coupling dominates the structural transition (T c = 326 K), hindering identification of excitonic correlations. A pronounced increase in the THz reflectivity manifests following photoexcitation and exhibits a BEC-like temperature dependence. This occurs well below the T c , suggesting a novel approach to monitor exciton condensate dynamics. Nonetheless, dynamic condensate-phonon coupling remains as evidenced by peaks in the enhanced reflectivity spectrum at select infrared-active phonon frequencies. This indicates that parametric reflectivity enhancement arises from phonon squeezing, validated using Fresnel-Floquet theory and density functional calculations. In conclusion, our results highlight that coherent dynamics can drive parametric stimulated emission with concomitant possibilities, including entangled THz photon generation.

36 MATERIALS SCIENCE↗

Multi-energy reconstructions, central electron temperature measurements, and early detection of the birth and growth of runaway electrons using a versatile soft x-ray pinhole camera at MST

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 μm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

Delgado-Aparicio, L. F. (ORCID:0000000167394380)↗

Correlated single- and few-electron backgrounds milliseconds after interactions in dual-phase liquid xenon time projection chambers

In this work, we characterize single- and few-electron backgrounds that are observed in dual-phase liquid xenon time projection chambers at timescales greatly exceeding a maximum drift time after an interaction. These instrumental backgrounds limit a detector's sensitivity to dark matter and cosmogenic neutrinos. Using the ~150g liquid xenon detector at Purdue University, we investigate how these backgrounds, produced after 122keV 57 Co Compton interactions, behave under different detector conditions. We find that the rates of single- and few-electron signals follow power-laws with time after the interaction. We observe linearly increasing rates with increased extraction field, and increased rates in the single-electron background with increased drift field. Normalizing the rates to the primary interaction's measured ionization signal, the rates increase linearly with the depth of the interaction. We test the hypothesis that infrared photons (1550nm) would stimulate and accelerate electron emission via photodetachment from impurities, but find that even 1 Watt of infrared light fails to reduce these backgrounds. We thus provide a characterization that can inform background models for low-energy rare event searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hunting extreme BL Lacertae blazars with Fermi-Large Area Telescope

ABSTRACT The emission of very-high-energy (VHE) photons ($E\ \gt\ 100\ \mathrm{GeV}$) in blazars is closely connected to the production of ultra-relativistic particles and the role of these γ-ray sources as cosmic particle accelerators. This work focuses on a selection of 22 γ-ray objects from the 2BIGB catalogue of high-synchrotron-peaked sources, which are classified as blazar candidates of uncertain type in the 4FGL-DR2 catalogue. We study these sources by means of a re-analysis of the first 10 yr of γ-ray data taken with the Fermi-Large Area Telescope, including the attenuation by the extragalactic background light. Their broad-band spectral energy distributions are also evaluated, using multiwavelength archival data in the radio, optical, and X-ray bands, in terms of one-zone synchrotron-self-Compton models, adding an external Compton component when needed. Out of this analysis, we identify 17 new extreme high-synchrotron-peaked (EHSP) candidates and compare their physical parameters with those of prototypical EHSP blazars. Finally, the resulting models are used to assess their detectability by the present and future generation of ground-based Imaging Atmospheric Cherenkov Telescopes. We find two VHE candidates within the reach of the current and next generation of Cherenkov telescopes: J0847.0−2336 and J1714.0−2029.

Nievas Rosillo, M. (ORCID:0000000283219168)↗

Spatial distribution of Compton-produced X-ray flux from rich and regular clusters of galaxies

The spatial distribution of radio and X-ray fluxes from rich and regular clusters of galaxies is discussed. A diffusion model is investigated in which high-energy electrons are ejected from a point source at the center of the cluster. While diffusing out, the electrons lose energy by Compton scattering with the universal blackbody photons, thus producing the X-ray emission. Traversing intracluster magnetic fields, the electrons emit synchrotron radio emission. For the Coma cluster of galaxies good agreement is found between the observed and predicted X-ray counting-rate distribution for the Compton model. From the observed radio data a value of about 3 by 10 to the -8th power gauss is deduced for the average magnetic-field strength in the central region of Coma.

Rephaeli, Y.↗

The transfer of cyclotron lines through the magnetospheric shell of Hercules X-1

Cyclotron emission from a strong magnetic field, has been proposed to identify line feature observed in the hard X-ray spectrum of the neutron star Hercules X-1. If this interpretation is indeed correct, and if the model wherein the 1.24 second hard X-ray pulse is due to the occultation of a more isotropic X-ray flux by an opaque magnetospheric shell is accepted then these observations can be used to place strict limits on the total source luminosity of the cyclotron emission. The observational fate of cyclotron line photons that have emerged from the region near the neutron star surface, but have yet to encounter an opaque shell at the magnetosphere is discussed. It is shown that if a narrow line is incident on such a shell, then a residual narrow feature can emerge from the shell.

Weave, R. P.↗

Compton scattering of microwave background radiation by gas in galaxy clusters

Based on data on the X-ray spectrum of the Coma cluster, interpreted as thermal bremsstrahlung, the expected brightness depletion from Compton scattering of the microwave background in the direction of the cluster is computed. The calculated depletion is about one-third that recently observed by Gull and Northover, and the discrepancy is discussed. In comparing the observed microwave depletion in the direction of other clusters which are X-ray sources it is found that there is no correlation with the cluster X-ray luminosity. Consequently, the microwave depletion observations cannot yet be taken as good evidence for a thermal bremsstrahlung origin for the X-ray emission. The perturbation from Compton scattering of photons on the high-frequency (Wien) tail of the blackbody distribution is computed and found to be much larger than predicted in previous calculations. In the Wien tail the effect is a relative increase in the blackbody intensity that is appreciably greater in magnitude than the depletion in the Rayleigh-Jeans domain.

Gould, R. J.↗

Quantum/classical mode evolution in free electron laser oscillators

The problem of oscillator evolution and mode competition in free electron lasers is studied. Relativistic quantum field theory is used to calculate electron wave functions, the angular distribution of spontaneous emission, and the transition rates for stimulated emission and absorption in each mode. The photon rate equation for the weakfield regime is presented. This rate equation is applied to oscillator evolution with a conventional undulator, a two-stage optical klystron, and a tapered undulator. The effects of noise are briefly discussed.

Bosco, P.↗

Scanning Photoelectron-Emission Inspection Equipment

Surfaces to be bonded tested for cleanliness. Equipment includes commercial photoelectron-emission sensor. Inspected surface irradiated with ultraviolet photons from source in sensor head while anode in sensor head collects photoelectrons ejected from surface by absorbed photons. If intensity and spectrum of ultraviolet light and distance between sensor and surface held constant, then photocurrent varies according to amount and type of contamination.

Gause, Raymond L.↗

Fast molecular shocks. I - Reformation of molecules behind a dissociative shock

The physical and chemical processes that operate in the cooling gas behind a fast, dissociative, single-fluid shock propagating in a dense interstellar cloud are discussed. The treatment extends previous theoretical work on fast molecular shocks by including the effects of the conversion of Ly-alpha photons into radiation of the two-photon continuum and into H2 Lyman band emission lines, the effects of CO photodissociation following line absorption, and the formation and destruction of molecules containing the elements nitrogen, silicon, and sulphur, and of the complex hydrocarbons. Abundance profiles for the molecular species of interest are presented. After molecular hydrogen begins to reform, by means of gas phase and grain surface processes, the neutral species OH, H2O, O2, CO, CN, HCN, N2, NO, SO, and SiO reach substantial abundances. The molecular ions HeH(+), OH(+), SO(+), CH(+), H2(+), and H3(+), are produced while the gas is still hot and partially ionized. Emissions from them provide a possible diagnostic probe of fast molecular shocks.

Neufeld, David A.↗

Correcting x ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters correcting for the reflectivity of the mirror and convolving with the detector response.

Chartas, G.↗

Correcting X-ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters, correcting for the reflectivity of the mirror and convolving with the detector response.

Chartas, G.↗

Renormalization Group Tutorial

Complex physical systems sometimes have statistical behavior characterized by power- law dependence on the parameters of the system and spatial variability with no particular characteristic scale as the parameters approach critical values. The renormalization group (RG) approach was developed in the fields of statistical mechanics and quantum field theory to derive quantitative predictions of such behavior in cases where conventional methods of analysis fail. Techniques based on these ideas have since been extended to treat problems in many different fields, and in particular, the behavior of turbulent fluids. This lecture will describe a relatively simple but nontrivial example of the RG approach applied to the diffusion of photons out of a stellar medium when the photons have wavelengths near that of an emission line of atoms in the medium.

Bell, Thomas L.↗