Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase change”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Differential scanning calorimetric survey of brominated PAN, pitch-based and vapor-grown fibers

A differential scanning calorimetric survey of brominated PAN, pitch-based and vapor-grown fibers revealed that only vapor-grown fibers heat-treated to temperatures of 2250 C or above exhibited the phase change at 100 C associated with the two-dimensional melting of bromine, similar to that observed in HOPG. All the pitch-based fibers tested, as well as vapor-grown fibers annealed to 2250 C, showed a substantial decrease in resistivity upon bromination but gave no indication of a phase change, suggesting that the bromine in these fibers does not have the long-range order needed to undergo two-dimensional melting. The brominated PAN fibers and unannealed vapor-grown fibers showed no phase change and no change in resistivity, indicating that these fibers do not intercalate bromine.

Jaworske, D. A.↗

CFD Model Development of a Cryogenic Storage Tank Self-Pressurization in Normal Gravity and Validation against SHIIVER Experiment

Two-Phase flow and heat transfer simulations with interfacial phase change of the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) self-pressurization experiment were conducted using storage tank CFD model in the framework of the ANSYS Fluent CFD code. The simulations were performed for the 70% fill level case with MLI on domes and no vapor cooling. All the phase change calculations in these simulations were generated by in-house Schrage-based evaporation-condensation model. The calculations were performed using both the VOF and Sharp Interface multiphase 2Daxisymmetric models. A number of parametric and sensitivity studies were performed to check the various aspects of the CFD model. These studies helped to understand the effects of varying several parameters on the tank pressure and temperature during self-pressurization. These parameters include: the effect of turbulence modeling and turbulence damping at the interface; the effect of constant vs. temperature dependent fluid properties; the effect of accommodation coefficient; the effect of modeling phase change at the interface and the effect of the fill level.

Computational Fluid Dynamics↗

Numerical Study and Validation of Melting and Solidification in PCM Embedded Heat Exchangers with Straight Tube

Latent heat thermal energy storage (LHTES) systems have shown great potential to enable reliable use of renewable energy and load shifting. LHTES offer high storage density and release energy at near constant temperature because of its use of phase change materials (PCMs). The cylindrical PCM heat exchangers (PCMHX) are one of the most used technologies due to their simplicity. Numerical models for such PCMHX enable engineers to estimate their performance for different design parameters and operating conditions without having to test them all. However, modeling the phase change phenomena can be challenging. To better understand the difficulties involving accurate modeling of PCMHX, a cylindrical latent storage unit filled with PCM and water as in-tube heat transfer fluid (HTF) is numerically investigated. This paper presents a study based on a 2D-axisymmetric model of a straight tube embedded in PCM in a cylindrical container. CFD is used to study the charging (melting) and discharging (solidification) phenomena. The models are validated against experimental and numerical data from the literature. The predicted local PCM temperature profile over time agrees within 2K compared to the experimental values. The paper also presents a simple method to estimate the melting and solidification phase change temperature range from limited data provided by PCM manufacturers.

PCM, melting, solidification, CFD, heat exchanger↗

CFD Model Development of a Cryogenic Storage Tank Self-Pressurization in Normal Gravity and Validation against SHIIVER Experiment

Two-phase flow and heat transfer simulations with interfacial phase change of the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) self-pressurization experiment were conducted using storage tank CFD model in the framework of the ANSYS Fluent CFD code. The simulations were performed for the 70% fill level case with MLI on domes and no vapor cooling. All the phase change calculations in these simulations were generated by in-house Schrage-based evaporation-condensation model. The calculations were performed using both the Volume of Fluid (VOF) and Sharp Interface multiphase 2D axisymmetric models. A number of parametric and sensitivity studies were performed to check the various aspects of the CFD model. These studies helped to understand the effects of varying several parameters on the tank pressure and temperature during self-pressurization. Turbulence modeling; turbulence damping at the interface; and using constant vs. temperature dependent fluid properties were shown to have the most profound influence on predicted tank pressures and temperatures. Current study indicates that including phase change at the interface into the computational model is crucial for accurate prediction of the tank self-pressurization process. The effect of accommodation coefficient was also studied. Tank pressure values predicted by the VOF, and Sharp Interface models are within 4% of the experimental ones.

Computational Fluid Dynamics↗

Design and performance evaluation of a dual-circuit thermal energy storage module for air conditioners

We present experimental results and a validated numerical model of a dual-circuit phase-change thermal energy storage module for air conditioners. The module incorporates a phase-change material encapsulated in compressed expanded natural graphite foam. We used n-tetradecane as the PCM with a transition temperature (~4.5 °C) suitable for air-conditioning applications. Heat exchange to and from the module is accomplished through two fluid loops operating as a heat source and sink embedded inside multiple slabs of the composite material. This dual-circuit design enables easier integration with air-conditioning equipment and provides enhanced flexibility in system operation as compared to the state-of-the-art thermal storage systems. When integrated with an air-conditioner, this design will enable peak-load shaving and enhances operational efficiency. The thermal storage device was designed for a nominal storage capacity of ~ 3.5 kWh. We evaluated the heat transfer and energy storage performance of this device using standalone heat transfer experiments to estimate key thermal resistances and identify design improvements before integration with an air conditioner. The numerical model of the heat exchanger uses a combination of discretized and lumped parameter approaches to maintain a balance between accuracy and computational expense. Our analyses show that the geometric features and integration of fluid tubes are key contributors to the thermal contact resistance between the fluid and the thermal storage material, and consequently, to the overall performance of the thermal storage module. Our standalone experiments also identified important operating scenarios in which this thermal storage module can be used for air-conditioning in buildings.

25 ENERGY STORAGE↗

Ice Particle Analysis of the Honeywell AL502 Engine Booster

A flow and ice particle trajectory analysis was performed for the booster of the Honeywell ALF502 engine. The analysis focused on two closely related conditions one of which produced an icing event and another which did not during testing of the ALF502 engine in the Propulsion Systems Lab (PSL) at NASA Glenn Research Center. The flow analysis was generated using the NASA Glenn GlennHT flow solver and the particle analysis was generated using the NASA Glenn LEWICE3D v3.63 ice accretion software. The inflow conditions for the two conditions were similar with the main differences being that the condition that produced the icing event was 6.8 K colder than the non-icing event case and the inflow ice water content (IWC) for the non-icing event case was 50% less than for the icing event case. The particle analysis, which considered sublimation, evaporation and phase change, was generated for a 5 micron ice particle with a sticky impact model and for a 24 micron median volume diameter (MVD), 7 bin ice particle distribution with a supercooled large droplet (SLD) splash model used to simulate ice particle breakup. The particle analysis did not consider the effect of the runback and re-impingement of water resulting from the heated spinner and anti-icing system. The results from the analysis showed that the amount of impingement for the components were similar for the same particle size and impact model for the icing and non-icing event conditions. This was attributed to the similar aerodynamic conditions in the booster for the two cases. The particle temperature and melt fraction were higher at the same location and particle size for the non-icing event than for the icing event case due to the higher incoming inflow temperature for the non-event case. The 5 micron ice particle case produced higher impact temperatures and higher melt fractions on the components downstream of the fan than the 24 micron MVD case because the average particle size generated by the particle breakup was larger than 5 microns which yielded less warming and melting. The analysis also showed that the melt fraction and wet bulb temperature icing criterion developed during tests in the Research Altitude Test Facility (RATFac) at the National Research Council (NRC) of Canada were useful in predicting icing events in the ALF502 engine. The development of an ice particle impact model which includes the effects of particle breakup, phase change, and surface state is necessary to further improve the prediction of ice particle transport with phase change through turbomachinery.

Ice Accretion Codes↗

An implicit formulation for the one-dimensional two-phase multi-interface Stefan Problem

In recent years there has been an intensified effort in the analysis of the Stefan Problem. Particular interest is directed towards determining the location of the interface between the solid and liquid phases of the substance being analyzed. A method has been developed using an implicit finite difference scheme which provides an accurate calculation of the phase change interface locations for a problem with simultaneous multiple phases. This is achieved through an iterative technique which requires the phase change energy to be correctly distributed within the nodes which are undergoing a phase transition. The new method predicts the interface locations without requiring time step size control or node size modification at the interfaces.

Williams, S. D.↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Thermophysical Property Measurements of Indium Iodide Crystals

InI single crystals are a promising room temperature detector material for X-rays and γ-rays. To improve crystal growth of the material by simulations, knowledge of thermophysical properties is essential, and since InI is orthorhombic, the anisotropy has to be taken into account. The temperature dependence of several thermophysical properties have been measured for InI, including the anisotropic thermal expansion, specific heat, and the thermal diffusivity in the b direction. The anisotropic thermal expansion coefficients, determined by X-ray diffraction, were α11=1.03·10-5 K-1, α22= 3.77·10-5 K-1, and α33 = 6.26·10-5 K-1. The specific heat, measured by DSC, was 0.226 J g-1 K-1 at 335K, with a temperature dependence of 9.582·10-5 J g-1 K-2. In the course of the X-ray diffraction and DSC measurements, it was shown that supposed phase changes, reported in older literature, are actually not phase changes but oxidation effects. The thermal diffusivity in the b direction, measured by the Xenon Flash method, was 0.288·10-6 m2s-1 at RT, decreasing to 0.253·10-6 m2 s-1 at 450K. In addition, the volume increase upon melting and the thermal expansion of the melt have been determined.

Martin Volz↗

A Hydraulic Motor-Alternator System for Ocean-Submersible Vehicles

An ocean-submersible vehicle has been developed at JPL that moves back and forth between sea level and a depth of a few hundred meters. A liquid volumetric change at a pressure of 70 bars is created by means of thermal phase change. During vehicle ascent, the phase-change material (PCM) is melted by the circulation of warm water and thus pressure is increased. During vehicle descent, the PCM is cooled resulting in reduced pressure. This pressure change is used to generate electric power by means of a hydraulic pump that drives a permanent magnet (PM) alternator. The output energy of the alternator is stored in a rechargeable battery that powers an on-board computer, instrumentation and other peripherals.The focus of this paper is the performance evaluation of a specific hydraulic motor-alternator system. Experimental and theoretical efficiency data of the hydraulic motor and the alternator are presented. The results are used to evaluate the optimization of the hydraulic motor-alternator system. The integrated submersible vehicle was successfully operated in the Pacific Ocean near Hawaii. A brief overview of the actual test results is presented.

alternator↗

Novel Functional Thermal Energy Storage Materials for Buildings Applications

The leakage of solid-liquid phase change materials (PCMs) tremendously limits their long-term application in thermal energy storage (TES). In this work, we present durable and form-stable shape-stabilized PCMs (ss-PCMs) for TES in building envelopes. These ss-PCMs are fabricated by encapsulating polyethylene glycol (PEG) consisting of different molecular weights within mesoporous magnesium oxide and silica dioxide. For the first time, the phase transition temperature (Tt) of ss-PCMs has been fine-tuned synthetically to be comfortable to building occupants by utilizing PEG blends with molecular weights of 600 and 800 g/mol. Several parameters, including surface hydrophilicity/hydrophobicity, surface area, and PCM loading percentage, have been studied to maximize the latent heat enthalpy for high energy efficiency and maintain form stability. The best ss-PCM candidate with suitable Tt and appreciable latent heat enthalpy exhibits a repeatable phase change behavior for up to 1,000 thermal cycles without leakage, which provides a promising solution for durable TES in buildings. The Tt tunability extends its application over a wider temperature range beyond buildings.

building envelope↗

Solar Steam on Demand

INTRODUCTION: This Report summarizes the research and development project performed by Sunvapor and the subrecipient National Renewable Energy Laboratory (NREL) during the period of 10/01/2018-9/30/2021. The work was aimed at the economic integration of solar steam with an industrial process, and in particular, the advantages that a novel type of thermal energy storage and collector design could bring to the system. The completed work includes experimental research on the storage material, design of the collector, engineering of a complete solar steam plant, and economic analysis. The plant was, in the end, not constructed, due to COVID-19 impacts to the project host. PURPOSE: The purpose of the project was to test the hypothesis that a levelized cost of heat (LCOH) of 2¢/kWh delivered to a steam-consuming process, including energy discharged from storage, could be feasibly achieved. PROJECT OBJECTIVES: For Budget Period 1 our objectives were to engineer a prototype industrial solar steam generation system, and design and test a Latent Heat Energy Storage (LHES) lab-scale system. For Budget Period 2 our objectives were to construct and test the solar steam prototype plant, and to build and factory-test a full LHES module. For Budget Period 3 our objective was to integrate the storage module with the solar steam generator, show successful long duration energy tests of the combined system, and use the results to project the LCOH of delivered steam to a second-generation plant. PROJECT OUTCOMES: Various phase change materials (PCMs) for the LHES were tested for compatibility with industrial steam uses as measured by phase change temperature, stability of latent heat of fusion, and their corrosive effects on steel (the heat exchanger material). Two of these materials (sodium formate and sodium/ potassium) showed potential to meet the technical criteria. The estimated cost of a complete LHES module with these materials did not meet economic targets. The developmental collector design builds from previous work to exploit the potential cost advantages of a spaceframe of lumber construction. Design improvements were achieved in assembly efficiency and structural performance. A complete engineering package was completed for the solar steam system without storage that included the developmental as well as commercial arrays. The plant was permitted for construction. The storage CAPEX for a reference plant was estimate to be greater than $\$ 57$/kWh. The LCOH of the system without storage and with developmental collectors of lumber construction was projected to be 2¢/kWh, assuming a FCR of 8.2% over thirty years. PROJECT MILESTONES: The Milestones fully achieved in the first Budget Period includes obtaining a Letter of Intent from an industrial steam-consuming project host, issuance of a construction permit, and corrosion resistance. The Milestone that was partly achieved was the degradation in the latent heat of fusion. Milestones associated with Budget Periods 2 and 3, related to the construction and operation of the plant were not achieved as a result of the host shutting down the plant due to COVID-19 impacts. CONCLUSIONS: Sunvapor was able to secure an agreement with a host to build a fully engineered and permitted solar steam plant that met the host’s economic goals. As a basis for comparison, the solar field design was comprised of eight commercial collector arrays and one developmental Green Parabolic Trough Collector (GPTC) array. The projected LCOH with a solar field entirely populated with a second generation GPTC met the goal of 2¢/kWh. The experimental program concerning the PCM indicated the feasibility of meeting their technical requirements for industrial steam uses. The cost of the complete LHES exceeded its $\$ 14$/kWh target, and therefore the inclusion of LHES could not be economically justified. Due to COVID-19 impacts on the host, the solar steam plant was not constructed.

14 SOLAR ENERGY↗

Transformations in crystals of DNA-functionalized nanoparticles by electrolytes

Colloidal crystals have applications in water treatments, including water purification and desalination technologies. It is, therefore, important to understand the interactions between colloids as a function of electrolyte concentration. We study the assembly of DNA-grafted gold nanoparticles immersed in concentrated electrolyte solutions. Increasing the concentration of divalent Ca 2+ ions leads to the condensation of nanoparticles into face-centered-cubic (FCC) crystals at low electrolyte concentrations. As the electrolyte concentration increases, the system undergoes a phase change to body-centered-cubic (BCC) crystals. This phase change occurs as the interparticle distance decreases. Molecular dynamics analysis suggests that the interparticle interactions change from strongly repulsive to short-range attractive as the divalent-electrolyte concentration increases. A thermodynamic analysis suggests that increasing the salt concentration leads to significant dehydration of the nanoparticle environment. We conjecture that the intercolloid attractive interactions and dehydrated states favour the BCC structure. Our results gain insight into salting out of colloids such as proteins as the concentration of salt increases in the solution.

Chemistry↗

The seasonal variation of the D region as inferred from propagation characteristics of LF radio waves

The propagation data of JG2AS 40 kHz (Japanese Standard Frequency), Loran C 100 kHz radio waves, and meteorological data were analyzed to study the association of propagation characteristics of LF radio waves with the atmospheric circulation in the mesosphere. The monthly averaged electric fields were depicted on the complex plane for typical summer and winter months, June and November. The locus traced out by the electric field vector during daytime is nearly circular. This is because during daytime the amplitude of the sky wave remains nearly constant while its phase changes in accord with the height change of the reflection layer, and thus the electric field vector traces out a circular locus with its center at the tip of the supposed ground wave vector. The locus has a loop during the sunrise or sunset period, which seems to arise from interference of two waves reflected by two different layers. In June the amplitude of the sky wave decreases rapidly before the dawn or increases after the dusk. In November such rapid change is not observed. During nighttime, the sky wave phase changes in such a way as to suggest that the reflection height moves upwards with time before midnight or lowers after midnight in November. In June it changes similarly before midnight, but after midnight it varies erratically. These characteristics are closely related to the structure of the D region, which is clearly shown by simulating the loci traced out by electric fields.

Ishimine, T.↗

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Changer Material Heat Capacitor

Effective Thermal management is essential for the safety and performance of human spacecraft, especially during long-duration missions with fluctuating heat loads. Phase Change Material (PCM) heat exchangers offer a compact, efficient solution by storing and releasing thermal energy through latent heat during phase transitions. This allows PCM systems to buffer transient thermal loads without immediate heat rejection, reducing the need for oversized radiators – particularly critical during ascent and re-entry when radiators are stowed. By maintaining stable temperatures in crew cabins and equipment bays, PCM technology enhances crew comfort, protects sensitive systems, and supports long-term mission sustainability with minimal mass and volume impact. A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, utilizes a laser welding microtube manufacturing process that promises increased reliability and performance over current manufacturing methods like brazing. This heat exchanger was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft, the crewed spacecraft taking NASA astronauts to the moon under the Artemis Program. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements.

Active Thermal Control Systems↗

Toward High-Endurance Nonvolatile Reconfigurable Metasurfaces

The applications of adaptive optics extend across multiple sectors, encompassing areas such as LiDAR, biological and chemical sensing, and free-space optical communications. The advent of metasurfaces optics with reconfigurability has offered a versatile platform for the design of compact optical components, offering a compelling alternative to their conventional bulky counterparts. In this study, we introduce the PROWESS (Phase change Reconfigurable Optical WavEfront Synthesis System project at NASA LaRC), electrically reconfigurable metasurfaces using low-loss, high-contrast phase change material (PCM), Ge2Sb2Se4Te integrated with IR-transparent silicon microheater for various practical applications. The talk covers a reliable platform for switching large-scale PCM-based devices utilizing a microheater and an architecture for the metasurface switching within an integrated circuit configuration, which is compatible with standard foundry fabrication processes. The utilization of near- to midinfrared transparent silicon microheater in the proposed architecture opens possibilities for the development of reconfigurable transmissive optics such as filters, zoom lenses, and beam steering modules. We demonstrated switching of 140 µm × 140 µm PCM pixel, on a 200 µm × 200 µm silicon microheater for several thousand cycles. Further, we performed an in-depth investigation into the failure mechanism utilizing techniques such as transmission electron microscopy and thermal modeling. Guidelines for device performance improvement are proposed, and an improved design with larger endurance is shown in progress. With further progress, we aim to unlock the full potential of PCM-based devices and advance the field of adaptive optics with demonstrable examples including a reconfigurable beam steerer for ocean surface flash LiDAR and Navigation Doppler LiDAR for precise lunar landing missions.

metasurface optics↗

Anomalous lattice thermal conductivity increase with temperature in cubic GeTe correlated with strengthening of second-nearest neighbor bonds

Understanding thermal transport mechanisms in phase change materials is critical to elucidating the microscopic picture of phase transitions and advancing thermal energy conversion and storage. Experiments consistently show that cubic phase germanium telluride (GeTe) has an unexpected increase in lattice thermal conductivity with rising temperature. Despite its ubiquity, resolving its origin has remained elusive. In this work, we carry out temperature-dependent lattice thermal conductivity calculations for cubic GeTe through efficient, high-order machine-learned models and additional corrections for coherence effects. We corroborate the calculated phonon properties with our inelastic X-ray scattering measurements. Our calculated lattice thermal conductivity values agree well with experiments and show a similar increasing trend. Through additional bonding strength calculations, we propose that a major contributor to the increasing lattice thermal conductivity is the strengthening of second-nearest neighbor interactions. The findings herein serve to deepen our understanding of thermal transport in phase-change materials.

36 MATERIALS SCIENCE↗

Programmable temperature control system for biological materials

A system was constructed which allows programmable temperature-time control for a 5 cu cm sample volume of arbitrary biological material. The system also measures the parameters necessary for the determination of the sample volume specific heat and thermal conductivity as a function of temperature, and provides a detailed measurement of the temperature during phase change and a means of calculating the heat of the phase change. Steady-state and dynamic temperature control is obtained by supplying heat to the sample volume through resistive elements constructed as an integral part of the sample container. For cooling purposes, this container is totally immersed into a cold heat sink. Using a mixture of dry ice and alcohol at 79 C, the sample volume can be controlled from +40 to -60 C at rates from steady state to + or - 65 C/min. Steady-state temperature precision is better than 0.2 C, while the dynamic capability depends on the temperature rate of change as well as the mass of both the sample and the container.

Anselmo, V. J.↗