Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Plant Engineers Solar Energy Handbook: Southern California Region

Discussed in order after the introduction are solar components and systems (collectors, storage, service hot water systems, space heating with liquid and air systems, space cooling, heat pumps and controls); computer programs for system optimization; local solar and weather data; a description of buildings and plants in Southern California applying solar technology; current Federal and California solar legislation; standards, codes and performance testing information; a listing of manufacturers, distributors, and professional services available in Southern California region; and information access. Finally, solar design check lists for those engineers who wish to design their own systems. The program for the Solar Workshop for the Plant Engineer, March 30, 1978, Los Angeles, California is included.

14 SOLAR ENERGY↗

Assuring the Quality of Test Results in the Field of Nuclear Techniques and Ionizing Radiation. The Practical Implementation of Section 5.9 of the EN ISO/IEC 17025 Standard

The paper aims to present a practical approach for testing laboratories to ensure the quality of their test results. It is based on the experience gained in assessing a large number of testing laboratories, discussing with management and staff, reviewing results obtained in national and international PTs and ILCs and exchanging information in the EA laboratory committee.According to EN ISO/IEC 17025, an accredited laboratory has to implement a programme to ensure the quality of its test results for each measurand. Pre-analytical, analytical and post-analytical measures shall be applied in a systematic manner. They shall include both quality control and quality assurance measures.When designing the quality assurance programme a laboratory should consider pre-analytical activities (like personnel training, selection and validation of test methods, qualifying equipment), analytical activities ranging from sampling, sample preparation, instrumental analysis and post-analytical activities (like decoding, calculation, use of statistical tests or packages, management of results).Designed on different levels (analyst, quality manager and technical manager), including a variety of measures, the programme shall ensure the validity and accuracy of test results, the adequacy of the management system, prove the laboratory's competence in performing tests under accreditation and last but not least show the comparability of test results.Laboratory management should establish performance targets and review periodically QC/QA results against them, implementing appropriate measures in case of non-compliance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing the Benefit of the Chemical Mixture Methodology: A Report on Methodology Testing and Potential Approaches for Improving Performance

Extensive testing shows that the current version of the Chemical Mixture Methodology (CMM) is meeting its intended mission to provide conservative estimates of the health effects from exposure to airborne chemical mixtures. However, the current version of the CMM could benefit from several enhancements that are designed to improve its application of Health Code Numbers (HCNs) and employ weighting factors to reduce over conservatism.

chemical mixture methodology↗

Residential Vehicle-to-Home Backup Power Capabilities: Key Findings from a ComEd Beneficial Electrification R&D Pilot

This report summarizes key findings from a collaborative technical study of residential, non-grid-tied vehicle-to-home (V2H) backup power systems in Commonwealth Edison’s (ComEd’s) service territory. The work integrates (1) a feeder-level technoeconomic analysis (TEA) using historical outage-event data and simulated electric-vehicle (EV) driving/charging profiles to estimate potential reliability and customer interruption-cost impacts under V2H and vehicle-to-grid (V2G) adoption scenarios; (2) controlled laboratory performance testing of a representative V2H backup ecosystem to characterize transfer-to-backup behavior, sustained power delivery, efficiency trends, and repeatable reliability limitations; and (3) a cybersecurity assessment aligned with NIST Cybersecurity Framework (CSF) 2.0 and ISO/SAE 21434 to evaluate interface-level risk drivers and identify program-relevant mitigations. Results indicate that V2H can provide measurable resilience value, but outcomes are strongly context dependent on outage patterns and the share of events that are “V2H-applicable.” Typical transfer-to-backup behavior clustered on the order of minutes, but rare long-delay edge cases were observed (including an event approaching 30 minutes) and should be treated as a reliability risk. High-power testing showed that peak-rated output is not necessarily continuously deliverable; stable operation may require operation below nameplate ratings and attention to thermal and installation constraints. The cybersecurity assessment highlights a broad attack surface spanning commissioning, home networks, embedded services, and cloud/OTA pathways, motivating minimum controls for secure onboarding, signed updates, patch cadence, and coordinated vulnerability response for any scaled deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization of 244 Cm Neutron Sources

There is a need to find a replacement for the 252 Cf sources currently used in Standards-based performance testing of neutron instrumentation. This is a result of its relatively short half-life, concerns about future availability and recent increases in cost. A potential replacement source, 244 Cm is evaluated in this study where two commercially available sources have been acquired and their neutron emission spectra measured using a pair of spectrometers. Both instruments showed the 244 Cm spontaneous neutron spectrum to be fully consistent with a MCNP6®-calculated spectrum using published Watt fission parameters for 244 Cm. In addition, the emission rate of the weaker 244 Cm source was established through a direct count rate comparison against a calibrated and similarly encapsulated 252 Cf source. The 244 Cm source emission rate was found to be in excellent agreement with value stated on the manufacturer's source certificate. It is concluded that 244 Cm would be an ideal replacement for 252 Cf based on its longer half-life (18.1 y) and its essentially identical neutron emission spectrum. In addition, 244 Cm sources are commercially available at reasonable cost.

244Cm↗

Report to Lincoln Labs on TWPAs

This past spring LLNL’s Quantum Sensor’s team received two TWPA amplifiers from Lincoln Labs along with a data-sheet explaining handling, operations and expected performance. Here we will outline some of the initial tests performed on this amplifiers as part of LLNL’s Quantum Sensors Strategic Initiative (QSSI). Initial testing confirmed that both amplifiers worked and provided gain and SNR improvement similar to that called out in the data-sheets provided.

42 ENGINEERING↗

Inspection Report on "Internal Controls over Accountable Classified Removable Electronic Media at Oak Ridge National Laboratory"

The Department of Energy's Oak Ridge National Laboratory (ORNL) conducts cutting edge scientific research. ORNL utilizes removable electronic media, such as computer hard drives, compact disks, data tapes, etc., to store vast amounts of classified information. Incidents involving breakdowns in controls over classified removable electronic media have been a continuous challenge for the Department. The loss of even one piece of such media can have serious national security implications. In 2004, the Department had a complex-wide 'stand-down' of all activities using classified removable electronic media, and such media containing Secret/Restricted Data or higher classified data was designated 'Accountable Classified Removable Electronic Media' (ACREM). As part of the stand-down, sites were required to conduct a 100 percent physical inventory of all ACREM; enter it all into accountability; and conduct security procedure reviews and training. Further, the Department implemented a series of controls, including conducting periodic inventories, utilizing tamper proof devices on ACREM safes, and appointing trained custodians to be responsible for the material. After performance testing and validation that the required accountability systems were in place, ACREM operations at ORNL were approved for restart on August 10, 2004. We conducted a review at ORNL and associated facilities to determine whether ACREM is managed, protected, and controlled consistent with applicable requirements. We found that: (1) Eight pieces of Secret/Restricted Data media had not been identified as ACREM and placed into a system of accountability. Consequently, the items were not subject to all required protections and controls, such as periodic accountability inventories, oversight by a trained custodian, or storage in a designated ACREM safe. (However, the items were secured in safes approved for classified material.) (2) Other required ACREM protections and controls were not implemented as follows: a tamper indicating device was not being used on an ACREM safe; records documenting when a certain safe was opened did not support that a purported inventory had been conducted; and a safe inventory had not been completed in a timely manner. (3) A Personal Digital Assistant and a thumb drive, both capable of recording or transmitting data, were stored in a security area without an analysis to identify vulnerabilities and compensatory measures having been conducted, as required. We also found that an ORNL Cooperative Research and Development Agreement partner had not disabled classified computer ports at the partner's site that were capable of writing classified information to external or removable media, as required. We made several recommendations designed to enhance the security of ACREM, security areas, and computers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Efficient Mesofluidic Separation of Large Particles in nuclear slurries - 20408

Efficient and effective particle separation is essential to cleanup of many nuclear wastes. For example, particle separation may be used to accelerate settle-decant bottlenecks that limit the throughput necessary to achieve the U.S. Department of Energy waste cleanup mission in a timely manner. Particle separation may be used to protect downstream processing equipment from pulses of solids that may be encountered near (within a few feet of) liquid-solid interfaces during waste transfer operations, thereby preventing work stoppages. Effective particle separation may permit efficient sludge washing. These are only a few of the ways in which particle separation is important. Yet, efficient and effective particle separation in nuclear processing environments remains challenging. For example, settle-decant operations permit larger and heavier particles to settle, leaving smaller, lighter particles suspended. However, settle-decant operations are slow, convection currents may resuspend solids, hindered settling of multicomponent slurries remains incompletely understood, and predictive models for settling in graduated cylinders fail to match limited observations of settling in large waste tanks. Additionally, pumping operations can cause turbulent resuspension of particles when the pump intake is close to the settled solids layer. Filtration techniques that use membranes or partially permeable barriers retain larger particles, permitting smaller particles to permeate. However, filters, including dead-end filtration, are prone to clogging and caking, operate at elevated pressures due to minimal void volume, and increase in pressure during operations, which require more control systems. Therefore, the need for high throughput particle separation techniques that operate with modest pressure drops persists. A novel mesofluidic separator presents the opportunity to effectively and efficiently accelerate the waste cleanup mission. The separator separates large particles from process streams across a broad range of particle sizes and has no moving parts or media to replace, regenerate, or clean. This separator design has an unusually large void volume, permitting operation at much higher flow rates (and lower pressures) than traditional filtration (e.g., dead-end filtration). Industrial-scale flow rates have been demonstrated. In performance testing, mesofluidic separators operate at might flow rates (>90 gpm (0.0006 m{sup 3}/s) in piping 3 inches (0.08 m) in diameter; Re>10{sup 5}), with modest pressure drop (∼25 psi (170 KPa) in testing). In complex, aggregating waste simulants, the separator loses <25% of flow projected over months without back pulsing or chemical cleaning. Mesofluidic separation presents infrastructure advantages, reduces risk, and provides mission impact. Infrastructure advantages include implementation within existing transfer systems, plug and play without facility modifications to safety systems, and operation at low pressures. The separator is flexible in location, may be positioned within or outside of waste tanks, and may replace or augment dead-end and cross-flow filters. Mesofluidic separation reduces risk by minimizing waste (no media to replace or regenerate and no cleaning chemicals to handle and dispose) and by minimizing filter change-out consistent with as low as reasonably achievable (ALARA) exposure to workers. The potential mission impact of these separators is substantial. The separator has potential to support, simplify, and accelerate in-farm transfers and waste feed delivery. Furthermore, the separator can free up settling and holding tanks in the Direct Feed Low-Activity Waste (DFLAW) mission by reducing or eliminating post-transfer settling and wait times with the potential to free up 1 Mgal (4000 m{sup 3}) of double-shell tank space. This paper quantitatively compares mesofluidic separation to dead-end filtration, discusses scale-up results, and considers the separator's potential to efficiently and effectively reduce the long-term environmental ability of particulate-rich nuclear wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of an autonomous sensor to evaluate the biological performance of the advanced turbine at Wanapum Dam

Hydropower is the largest renewable energy resource in the United States and the world. However, hydropower dams have adverse ecological impacts because migrating fish may be injured or killed when they pass through hydroturbines. In the Columbia and Snake River basins, dam operators and engineers are required to make those hydroelectric facilities more fish-friendly through changes in hydroturbine design and operation after fish population declines and the subsequent listing of several species of Pacific salmon under the Endangered Species Act of 1973 . Public Utility District No. 2 of Grant County, Washington, requested authorization from the Federal Energy Regulatory Commission to replace the ten turbines at Wanapum Dam with advanced hydropower turbines designed to improve survival for fish passing through the turbines while improving operation efficiency and increasing power generation. As an additional measure to the primary metric of direct injury and mortality rates of juvenile Chinook salmon using balloon tag-recapture methodology, this study used an autonomous sensor device - the Sensor Fish - to provide insight into the specific hydraulic conditions and physical stresses experienced by the fish as well as the specific causes of fish biological response. We found that the new hydroturbine blade shape and the corresponding reduction of turbulence in the advanced hydropower turbine were effective in meeting the objectives of improving fish survival while enhancing operational efficiency of the dam. The frequency of severe events based on Sensor Fish pressure and acceleration measurements showed trends similar to those of fish survival determined by the balloon tag-recapture methodology. In addition, the new turbine provided a better pressure and rate of pressure change environment for fish passage. Altogether, the Sensor Fish data indicated that the advanced hydroturbine design improved passage of juvenile salmon at Wanapum Dam.

13 HYDRO ENERGY↗

Secondary ion mass spectrometry for superconducting radiofrequency cavity materials

Historically, many advances in superconducting radio frequency (SRF) cavities destined for use in advanced particle accelerators have come empirically, through the iterative procedure of modifying processing and then performance testing. However, material structure is directly responsible for performance. Understanding, the link between processing, structure, and performance will streamline and accelerate the research process. In order to connect processing, structure, and performance, accurate and robust materials characterization methods are needed. Here in this paper, one such method, SIMS, is discussed with focus on analysis of SRF materials. In addition, several examples are presented, showing how SIMS is being used to further understanding of materials based SRF technologies.

43 PARTICLE ACCELERATORS↗

Heat and Mass Transfer Study to Understand Thermal-Cycling Absorption Process (TCAP) Scale-Up Issues

TCAP was invented by SRNL and is a world-leading technology in hydrogen isotope separation, a critical process for fusion energy development and scientific research. External interests inquiries have been received for as high as a 1000-fold throughput increase over the currently available TCAP system. This study determined a major factor impacting TCAP column scale-up. A model derived by J. Calvin Giddings indicates that the combination of a coiled packed column and an increase in the column tube radius results in reduction of column separative performance. Reevaluation of data from SRNL TCAP column testing performed in 2004 indicates that the results are consistent with the Giddings model. Work with the Auburn University Center for Microfibrous Materials Manufacturing indicates that microfibrous entrapped sorbents (MFES) made from copper microfibers and Pd K could resolve issues with channeling and improve heat transfer and cycle time in TCAP columns.

36 MATERIALS SCIENCE↗

Hybrid Analytics Solution to Improve Coal Power Plant Operations

This project focused on developing advanced methods for thermal performance monitoring of a coal-fueled power plant. The specific goal was to develop and demonstrate a new thermal performance monitoring approach using a hybrid model that integrates a physics-based heat balance model with a machine learning-based pattern recognition model. The hybrid model enables increased accuracy and scope of the thermal analysis and an improved ability to monitor and detect changes in plant operation. This new approach takes full advantage of the individual model capabilities and creates an important new set of capabilities not previously possible using the two types of models separately. Using the heat balance model, a rich set of derived parameters (virtual sensors) are calculated from the measured plant operating data at each time point. The combined measured and derived data values are used by machine learning algorithms to create pattern recognition models over the range of normal unit operation. To create the monitoring models, historical data from normal operation of the plant is first processed by the heat balance model to compute the derived parameter data. The result is a greatly expanded set of normal operating data that can be used as input to create the pattern recognition model. Once the models are calibrated for normal operation, the hybrid model is suitable for use in continuous online monitoring. During online monitoring, new plant operating data is processed first by the heat balance model and then by the pattern recognition model. Results from the pattern recognition model quantify the deviation of each measured or derived parameter from its expected value in normal operation. The hybrid models can detect abnormal changes in plant operating data with very high accuracy and sensitivity. When abnormal behavior is detected, alerts are generated automatically for evaluation by the plant monitoring staff. The new hybrid solution product was developed and verified in the performance of the project. The hybrid solution was tested first in a simulation environment that mimicked the plant data systems and infrastructure used by U.S. power generating plants and utilities. The hybrid solution was then deployed for real-time, online monitoring of an operating coal-fueled power plant at a field test site. Field testing demonstrated that all hybrid solution development objectives were accomplished. The project work was based on combining the capabilities of two existing software products to create the new hybrid solution product. One of these was the existing MapEx® heat balance product and the other was the existing SureSense® advanced pattern recognition product. Each of these separate products was assessed to be at a Technology Readiness Level (TRL) of 9 at the start of the effort. The hybrid solution product was assessed to be at a TRL of 2 at the start of the project based on early feasibility work by the project team. At completion of the field testing performed in the project, the hybrid solution product was assessed to be at a TRL of 7. The project team expects that the hybrid solution product will be deployed commercially and will achieve a TRL of 9 within one year after completion of the project.

01 COAL, LIGNITE, AND PEAT↗

Benchmark Specifications for TREAT Tests M5, M6, and M7

Detailed information describing three TREAT tests performed on metallic fuels has been collected and organized for use as a benchmark in evaluating the performance of metallic fuel models and codes. The tests, designated M5, M6, and M7, subjected EBR-II-irradiated fuel pins to a single type of overpower transient (at prototypical conditions with full coolant flow and an exponential power rise on an 8 second period) in flowing sodium loops. Six fuel pins were tested; five were ternary (U-19Pu-10Zr) alloy fuel clad in D9 with burnup ranging from 0.8 to 9.8 at. %, and one was binary alloy fuel (U-10Zr) clad in HT9 with 2.9 at. % burnup. The information gathered from the test records is expected to be useful for pre-transient characterization of the irradiated fuel pins as well as the transient analysis of the metallic fuel when subjected to severe accident conditions. This report presents benchmark specifications for the M5, M6, and M7 TREAT tests, identifies where primary sources of benchmark-related information can be found, and includes background information to help a user of the data understand their applicability and limitations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Relationship between Particle Size Distribution of Low-Rank Pulverized Coal and Power Plant Performance

The impact of particle size distribution (PSD) of pulverized, low rank high volatile content Alaska coal on combustion related power plant performance was studied in a series of field scale tests. Performance was gauged through efficiency (ratio of megawatt generated to energy consumed as coal), emissions (SO 2 , NO x , CO), and carbon content of ash (fly ash and bottom ash). The study revealed that the tested coal could be burned at a grind as coarse as 50% passing 76 microns, with no deleterious impact on power generation and emissions. The PSD’s tested in this study were in the range of 41 to 81 percent passing 76 microns. There was negligible correlation between PSD and the followings factors: efficiency, SO 2 , NO x , and CO. Additionally, two tests where stack mercury (Hg) data was collected, did not demonstrate any real difference in Hg emissions with PSD. The results from the field tests positively impacts pulverized coal power plants that burn low rank high volatile content coals (such as Powder River Basin coal). These plants can potentially reduce in-plant load by grinding the coal less (without impacting plant performance on emissions and efficiency) and thereby, increasing their marketability.

Ganguli, Rajive↗

Laser-induced breakdown spectroscopy acoustic testing of the Mars 2020 microphone

Here, the SuperCam instrument suite onboard the Mars 2020 rover will include the Mars Microphone, an experiment designed to record the sounds of the SuperCam laser strikes on rocks and also aeolian noise. In order to record shock waves produced by the laser blasts, the Mars Microphone must be able to record audio signals from 100 Hz to 10 kHz on the surface of Mars, with a sensitivity sufficient to monitor a laser impact at distances up to 4 m. We have used the Aarhus planetary simulator facility to test the Mars 2020 rover microphone in a controlled Martian environment. The end-to-end tests performed in a 6 mbar CO 2 atmosphere, with wind, and also with the microphone at –80°C have demonstrated that the SuperCam/Mars Microphone requirements are satisfied. Tests were also performed on Martian soil simulant targets showing that the variation of the acoustic energy of the shock wave depends on the level of compaction of the target.

47 OTHER INSTRUMENTATION↗

Diesel Oxidation Catalyst Performance with Biodiesel Formulations

Biodiesel (i.e., mono-alkyl esters of long chain fatty acids derived from vegetable oils and animal fats) is a renewable diesel fuel providing life-cycle greenhouse gas emission reductions relative to petroleum-derived diesel. With the expectation that there would be widespread use of biodiesel as a substitute for ultra-low sulfur diesel (ULSD), there have been many studies looking into the effects of biodiesel on engine and aftertreatment, particularly its compatibility to the current aftertreatment technologies. The objective of this study was to generate experimental data to measure the effectiveness of a current technology diesel oxidation catalysts (DOC) to oxidize soy-based biodiesel at various blend levels with ULSD. Biodiesel blends from 0 to 100% were evaluated on an engine using a conventional DOC. In the steady-state performance test where fuel dosing rate was increased at fixed DOC inlet temperature, B20 performed similarly to ULSD at the lowest flow rate or exhaust temperature over 340 degrees C for medium and high flows. B50 blends performed nearly as well under most conditions. Higher blends exhibited reduced thermal efficiency and DOC outlet temperature with increasing dosing rate under most conditions and required exhaust temperatures over 400 degrees C to achieve or nearly achieve performance similar to ULSD. In the steady-state light of test where fuel dosing rate is fixed but exhaust temperature is increased incrementally, B20 generally performed similarly to ULSD at the highest inlet temperature, with only minor deficiencies at lower temperatures. Higher blends exhibited lower thermal efficiency and did not achieve as high DOC outlet temperatures. In the transient light-off test light-off temperature for ULSD was typically less than 225 degrees C, while for B100 it ranged from 290 degrees C to 330 degrees C. Based on the data set, it can be concluded that biodiesel fuels have a higher light-off temperature primarily because of their higher boiling points, with a minor secondary impact of their lower energy content.

ADVANCED PROPULSION SYSTEMS,BIOMASS FUELS↗

Impact of Porous Transport Layer Morphology on the Performance of Proton Exchange Membrane Water Electrolyzers with Ultra-Low Iridium Loadings

Reducing Ir loadings in proton exchange membrane water electrolyzer anodes is critical for lowering capital expenses. Loading reduction could be achieved by improving the Ir activity via doping/alloying and/or the development of advanced microstructures. However, the anode porous transport layer (PTL) is a comparatively simple component whose properties also impact Ir utilization. Therefore, well-designed PTLs may also enable reduced Ir loadings. In this work, we survey eight PTLs from various manufacturers to observe their impact on cell performance at low (0.4 mg Ir cm -2 ) and ultralow (0.1 mg Ir cm -2 ) Ir loadings. The PTLs were characterized by their microstructural properties, including porosity, particle size distribution, and pore size distribution. Electrochemical cell performance was correlated to PTL morphology, and it was found that PTLs with lower porosities and smaller particle and pore radii enabled good performance even at ultralow Ir loadings. 1000-h durability testing indicated that using lower porosity PTLs can significantly improve durability behavior. A runaway voltage phenomenon was observed during durability testing of cells with ultralow Ir loadings, which was caused by increases in both anode and cathode overpotentials. Furthermore, we observed that the beginning of test performance of 0.1 mg Ir cm -2 cells correlates to the 1000-h degradation rates of 0.4 mg Ir cm -2 cells, suggesting that for the Ir catalyst used in this work, short-term testing at ultralow loadings can be used as an indicator of long-term degradation at higher loadings.

08 HYDROGEN↗