Fermilab Italian Student Program (Final Report)

I participated to the 2019 Fermilab Italian Student Program under the supervision of Anadi Canepa and Lorenzo Uplegger. I worked with the Fermilab research group that is involved with the R&D of the CMS Outer Tracker. The Compact Muon Solenoid (CMS) is a a general-purpose detector located at the Large Hadron Collider (LHC), the world's most powerful particle accelerator. In the next years LHC will undergo the High-Luminosity LHC upgrade, which will bring its luminosity from 1 × 10 34 cm -2 s -1 to 1.5 × 10 34 cm -2 s -1 . This increase in luminosity will require an upgrade of CMS as well, in order to comply with the augmented rate of particles which will cross the detector. The CMS tracker is a detector, composed of various modules made of silicon pixel trackers and silicon strip trackers, whose aim is to reconstruct the trajectories of the particles produced by the collisions in LHC. The tracker is ideally divided in Inner Tracker and Outer Tracker. The HL-LHC upgrade put important challenges in the designing of the tracker. It will have to withstand the irradiation of a large fluence of particles, without suffering a too severe deterioration of its performance. In addition to this, in order to comply with the increased rate of events that CMS will need to detect, the tracker will be exploited for triggering at the fully hardware Level 1 Trigger, in contrast to the current tracker, whose data are only used for the software High-Level Trigger. This feature is managed by the "stub logic", which will be explained in chapter 2. During the months of August and September at Fermilab I carried out the data analysis of three test beam runs performed in the last two years on the 2S Outer Tracker Minimules. The 2S Minimoule consists of two silicon strip trackers placed one upon the other with the strips kept parallel.

43 PARTICLE ACCELERATORS↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Azimuthal correlation anisotropies in p + p collisions simulated using Pythia

Stimulated by a keen interest in possible collective behavior in high-energy proton-proton and proton-nucleus collisions, we study two-particle angular correlations in pseudorapidity and azimuthal differences in simulated p + p interactions using the Pythia 8 event generator. Multi-parton interactions and color connection are included in these simulations, which have been perceived to produce collectivity in final-state particles. Meanwhile, contributions from genuine few-body nonflow correlations, not of collective flow behavior, are known to be severe in these small-system collisions. We present our Pythia correlation studies pedagogically and report azimuthal harmonic anisotropies analyzed using several methods. We observe anisotropies in these Pythia simulated events qualitatively and semi-quantitatively, similar to experimental data. Furthermore, our findings highlight the delicate nature of azimuthal anisotropies in small-system collisions and provide a benchmark that can aid in improving data analysis and interpreting experimental measurements in small-system collisions.

Pythia↗

Determination of Chemical Freeze-Out Parameters from Net-Kaon Fluctuations at RHIC

We calculate the mean-over-variance ratio of the net-kaon fluctuations in the Hadron Resonance Gas (HRG) Model for the five highest energies of the RHIC Beam Energy Scan (BES) for different particle data lists. We compare these results with the latest experimental data from the STAR collaboration in order to extract sets of chemical freeze-out parameters for each list. We focused on the PDG2012 and PDG2016+ particle lists, which differ largely in the number of resonant states. Furthermore, our analysis determines the effect of the amount of resonances included in the HRG on the freeze-out conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Plasma-assisted catalysis for ammonia synthesis in a dielectric barrier discharge reactor: key surface reaction steps and potential causes of low energy yield

Ammonia synthesis experiments were carried out in a coaxial dielectric barrier discharge (DBD) reactor packed with several different supports and metal catalysts. There was a marked increase in the reaction rate, over that obtained in an empty DBD plasma reactor, upon introduction of a packed bed of γ-Al 2 O 3 , Ru/γ-Al 2 O 3 , or SiO 2 particles. The difference in the reaction rates over γ-Al 2 O 3 and Ru/γ-Al 2 O 3 was minimal. Complementary zero-dimensional plasma kinetic model analysis was also performed using inputs from experimental data. This kinetic analysis allowed for gas phase reactions, Eley–Rideal (E–R) reactions, and direct adsorption of radical species on the γ-Al 2 O 3 surface. On the metal surface, dissociative adsorption of N 2 and H 2 , and Langmuir–Hinshelwood reactions were also included. This analysis revealed that, under the conditions of our experiments, ammonia synthesis proceeds principally by the formation of reactive radicals in the gas phase, which then adsorb and participate in E–R reactions on both the metal and support material surfaces. Furthermore, this finding illustrates a challenge for substantially increasing the energy yield for plasma-assisted ammonia synthesis in typical DBD reactors containing packed catalyst beads.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Leveraging Topological Events in Tracking Graphs for Understanding Particle Diffusion

Abstract Single particle tracking (SPT) of fluorescent molecules provides significant insights into the diffusion and relative motion of tagged proteins and other structures of interest in biology. However, despite the latest advances in high‐resolution microscopy, individual particles are typically not distinguished from clusters of particles. This lack of resolution obscures potential evidence for how merging and splitting of particles affect their diffusion and any implications on the biological environment. The particle tracks are typically decomposed into individual segments at observed merge and split events, and analysis is performed without knowing the true count of particles in the resulting segments. Here, we address the challenges in analyzing particle tracks in the context of cancer biology. In particular, we study the tracks of KRAS protein, which is implicated in nearly 20% of all human cancers, and whose clustering and aggregation have been linked to the signaling pathway leading to uncontrolled cell growth. We present a new analysis approach for particle tracks by representing them as tracking graphs and using topological events – merging and splitting, to disambiguate the tracks. Using this analysis, we infer a lower bound on the count of particles as they cluster and create conditional distributions of diffusion speeds before and after merge and split events. Using thousands of time‐steps of simulated and in‐vitro SPT data, we demonstrate the efficacy of our method, as it offers the biologists a new, detailed look into the relationship between KRAS clustering and diffusion speeds.

McDonald, T.↗

Final Report: A Multi-Channel Fusion Product

The goal of this project was to measure charged fusion products from the d(d,p)t reaction in MAST-U plasmas as a function of time and position with good energy resolution using a system of up to six charged particle detectors. The data from this new diagnostic will make it possible to determine the neutral beam ion density profile as a function of R, z, and t with reduced model dependency and contribute new information to a global analysis of fast ion diagnostic data needed for the determination of the fast ion distribution function (velocity space tomography).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Liquid lithium divertor analysis using coupled plasma material interaction model

A liquid lithium divertor can improve performance of future fusion devices by creating efficient power exhaust and improving the energy confinement via pumping of the hydrogen isotopes. In addition, significantly higher heat fluxes can be handled if controlled vapor shielding is used to redistribute the divertor heat flux over a wider area. Design and optimization of such a system calls for an analysis model which includes a strong two-way coupling between the plasma and divertor material. The incoming plasma heat and particle flux will affect the divertor surface temperature, which is a defining factor of the lithium evaporative and sputtered flux going into the plasma. Results of the coupled model based on the plasma edge code SOLPS-ITER and the computational fluid dynamics (CFD) code ANSYS-CFX will be presented for different configurations. An analytical slab flow model is used as a heat transfer boundary condition for SOLPS, defining particle flux from the wall via calculation of the surface temperature. At the final step, results of the SOLPS analysis are verified using a 3D CFD magnetohydrodynamics (MHD) analysis which uses heat and particle flux from SOLPS as a boundary condition. In addition to plasma heat flux, both analytical and CFD temperature models include several plasma material interaction effects, such as lithium evaporation, condensation and sputtering based on deuterium target flux. New adatom sputtering model based on the available experimental data is presented. Analytical model is expanded to include free surface axisymmetric configurations. Results of parametric studies of the divertor configurations with different lithium inlet temperature and velocity will be presented leading to the optimal design resulting in the lowest possible lithium contamination in the core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rapid Inverse Parameter Inference Using Physics-Informed Neural Network

As Li-ion batteries become more essential in today's economy, tools need to be developed to accurately and rapidly diagnose a battery's internal state-of-health. Using a Li-ion battery's (high-rate) voltage response, it is proposed to determine a battery's internal state through Bayesian calibration. However, Bayesian calibration is notoriously slow and requires thousands of model runs. To accelerate parameter inference using Bayesian calibration, a surrogate model is developed to replace the underlying physics-based Li-ion model. Developing a surrogate model for rapid Bayesian calibration analysis is discussed for both the single particle model (SPM) and the pseudo two-dimensional (P2D) model. Surrogate models are constructed using physics-informed neural networks (PINNs) that encode the influence of internal properties on observed voltage responses. In practice, a neural network can be trained by: 1) using simulation results of the physics-based model (i.e., a data-loss approach); 2) using the residuals of the governing equations themselves (i.e., a physics-loss approach); or 3) using a combination of simulation results and governing equation residuals. In the present work, PINNs are developed using a variety of training losses and neural network architectures. In this analysis, it is shown that a PINN surrogate model can be reliably trained with only physics-informed loss. However, using a coupled data-informed and physics-loss approach produced the most accurate PINNs.

Bayesian calibration↗

Normalizing flows for domain adaptation when identifying Λ hyperon events

Here this study focuses on the application of a normalizing flow as a method of domain adaptation when classifying physics data. Normalizing flows offer a way to transform data points between two different distributions. The present study investigates a novel method of transforming latent representations of physics data to a normal distribution and then to a physics distribution again. The final distribution models a simulated distribution. After being transformed, the data can be classified by a neural network trained on labeled simulation data. The present study succeeds in training two normalizing flows that can transform between data (or simulation) and a Gaussian distribution.

47 OTHER INSTRUMENTATION↗

Investigating high-energy proton-induced reactions on spherical nuclei: Implications for the preequilibrium exciton model

A number of accelerator-based isotope production facilities utilize $100-200$ MeV proton beams due to the high production rates enabled by high-intensity beam capabilities and the greater diversity of isotope production brought on by the long range of high-energy protons. However, nuclear reaction modeling at these energies can be challenging because of the interplay between different reaction modes and a lack of existing guiding cross section data. A Tri-lab collaboration has been formed between the Lawrence Berkeley, Los Alamos, and Brookhaven National Laboratories to address these complexities by characterizing charged-particle nuclear reactions relevant to the production of established and novel radioisotopes. In the inaugural collaboration experiments, stacked-targets of niobium foils were irradiated at the Brookhaven Linac Isotope Producer ($E_p=200$ MeV) and the Los Alamos Isotope Production Facility ($E_p=100$ MeV) to measure $^{93}$Nb(p,x) cross sections between $50-200$ MeV. The results were compared with literature data as well as the default calculations of the nuclear model codes TALYS, CoH, EMPIRE, and ALICE. The default code predictions largely failed to reproduce the measurements. Therefore, we developed a standardized procedure, which determines the reaction model parameters that best reproduce the most prominent reaction channels in a physically justifiable manner. Overall, the primary focus of the procedure was to determine the best parameterization for the pre-equilibrium two-component exciton model. This modeling study revealed a trend towards a relative decrease for internal transition rates at intermediate proton energies ($E_p=20-60$ MeV) in the current exciton model as compared to the default values. The results of this work are instrumental for the planning, execution, and analysis essential to isotope production.

43 PARTICLE ACCELERATORS↗

Cu Doping Increases Capacity Retention in LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) by Altering the Potential of the Ni-Based Redox Couple and Inhibiting Particle Pulverization

To discern the influence of Cu 2+ as a dopant on both the structural and electrochemical characteristics of LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622), Cu 2+ (aq) was added to the coprecipitation synthesis from the constituent ions. At 5 mol % Cu 2+ , a single-phase Cu-NMC product results, evidenced by an increase in d-spacing along the [003] and [104] directions and a slight increase in the crystal volume of the R–3m hexagonal (rock-salt superstructure) lattice. XRD data and high-resolution TEM imaging support Cu 2+ doping primarily on the transition metal 3b Wyckoff sites. Here, galvanostatic cycling of Cu-NMC shows a reversible gravimetric capacity of 102 mAh/g compared to 136 mAh/g for undoped NMC. Despite the lower capacity, the discharge capacity retention of Cu-NMC is 89% after 100 cycles compared to only 70% for NMC. XPS analysis reveals that this lower capacity is due to an increase in the concentration of Ni 3+ ions at the surface, while XRD data collected at the top and bottom of charge show a smaller decrease in crystalline domain size for Cu-NMC (40.5% decrease) compared to NMC (74.7% decrease), translating to pulverization of the secondary particles.

25 ENERGY STORAGE↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 uBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment and Performance of Flexible Quench Antenna Array Diagnostics for Superconducting Magnets

FNAL has been developing multiple versions of flexible quench antennas (flex-QA), including some specially optimized for high sensitivity and/or high resolution, to characterize quench events and transients during current ramping in superconducting magnets. A fundamental feature in our use of these is the creation of grid-like structures of sensitive elements to cover coil surfaces, with the aim of getting precise localization of magnetic flux-change events. The flex-QA are coupled with fast data-acquisition, allowing comprehensive analysis of signals at the relevant fine time scales. In addition to arrays of various flex-QA types being used during cryogenic testing of superconducting magnets, we also are utilizing a newly developed room temperature test stand to better understand QA response characteristics. The data from actual superconducting magnet tests, warm test stand measurements, and simulation data on the same QA designs allows us to draw conclusions on operational feasibility and plan better for improvements of our sensors. In this paper we present data from the multiple tests performed and analysis results. Flex-QA designs are compared, and their features, options, and optimization discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

LAMP Emittance Budget, Rev. 1

This report summarizes the performance limits of the LANSCE Coupled-Cavity Linac (CCL). These results are captured or summarized directly from the references cited. This report was written in support of the LANSCE Modernization Project (LAMP). This brief report summarizes the emittance budget for the LANSCE Modernization Project (LAMP). While the project Key Performance Parameters (KPPs) specify threshold and objective requirements for charge delivered to each experimental area, no upper limits on beam emittances are specified. To maintain low losses in the high-energy section of the LANSCE linac and hands-on maintenance, some upper limits on beam emittance need to be specified for the new LAMP front-end performance. The scope of the LAMP project replaces the injector section and drift-tube linac (DTL) up to 100 MeV of the existing LANSCE linac. This new design replacement will be integrated with the remaining coupled cavity linac (CCL) which makes up most of the accelerator at LANSCE and accelerates the beam to a final energy of 800 MeV. The initial approach that has been used to define an emittance budget for the new LAMP front end is based on recent and historical measured beam emittances at 100 MeV for the three beam types accelerated at LANSCE: H+ (protons for isotope production), LBEG (H- beam for delivery to proton radiography and to the Lujan neutron spallation target, and MPEG (H- beam for delivery to the Weapons Neutron Research facility). The emittance budget (upper limit) for each beam type has been selected to maintain the losses in the CCL to a level approximately equivalent to those observed in present operations to first order. However, the goal of the LAMP project is to improve the quality of the beams injected into the CCL, if possible, thus allowing for higher average current operation while also lowering beam losses and activation at high beam energies. The table below summarizes the beam measurements evaluated and used to establish a conservative emittance budget for LAMP based on known historical beam losses and activation. However, based on estimates of the CCL admittance and the Isotope Production Facility (IPF) beamline acceptance, a more relaxed transverse emittance upper limit of 0.095 π-cm-mrad, rms, normalized may be acceptable at 100 MeV while still meeting the LAMP performance requirements for charge delivery to each LANSCE experimental area and maintaining hands-on maintenance. This upper limit is supported by a recent analysis of operational data. Additionally, the present conceptual LAMP front-end design meets this requirement.

43 PARTICLE ACCELERATORS↗

New Perspectives on Spectroscopic Factor Quenching from Reactions

The evolution of single-particle strengths as the neutron-to-proton asymmetry changes informs us of the importance of short- and long-range correlations in nuclei and has therefore been extensively studied for the last two decades. Surprisingly, the strong asymmetry dependence of these strengths and their extreme values for highly asymmetric nuclei inferred from knockout reaction measurements on a target nucleus are not consistent with what is extracted from electron-induced, transfer, and quasi-free reaction data, constituting a two-decade old puzzle. This work presents the first consistent analysis of one-nucleon transfer and one-nucleon knockout data, in which theoretical uncertainties associated with the nucleon-nucleus effective interactions considered in the reaction models are quantified using a Bayesian analysis. Here, our results demonstrate that, taking into account these uncertainties, the spectroscopic strengths of loosely bound nucleons extracted from both probes agree with each other and, although there are still discrepancies for deeply bound nucleons, the slope of the asymmetry dependence of the single-particle strengths inferred from transfer and knockout reactions are consistent within 1 σ . Both probes are consistent with a small asymmetry dependence of these strengths. The uncertainties obtained in this work represent a lower bound and are already significantly larger than the original estimates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New dark matter analysis of milky way dwarf satellite galaxies with madhatv2

We obtain bounds on dark matter annihilation using 14 years of publicly available Fermi-LAT data from a set of 54 dwarf spheroidal galaxies, using spectral information from 16 energy bins. We perform this analysis using our updated and publicly available code , which can be used to test a variety of models for dark matter particle physics and astrophysics in an accessible manner. In particular, we note that including Carina III in the analysis strengthens constraints on s -wave annihilation into two-body Standard Model final states by a factor of ∼ 3 but broadens the error on the constraint due to the large uncertainty of its J -factor. Our findings illustrate the importance of verifying if Carina III is in fact a dwarf spheroidal galaxy and measuring more precisely its J -factor. More generally, they highlight the significance of forthcoming discoveries of nearby ultrafaint dwarfs for dark matter indirect detection. Published by the American Physical Society 2024

Astronomy & Astrophysics↗