Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

The EPIC-MOS Particle-Induced Background Spectrum

We have developed a method for constructing a spectrum of the particle-induced instrumental background of the XMM-Newton EPIC MOS detectors that can be used for observations of the diffuse background and extended sources that fill a significant fraction of the instrument field of view. The strength and spectrum of the particle-induced background, that is, the background due to the interaction of particles with the detector and the detector surroundings, is temporally variable as well as spatially variable over individual chips. Our method uses a combination of the filter-wheel-closed data and a database of unexposed-region data to construct a spectrum of the "quiescent" background. We show that, using this method of background subtraction, the differences between independent observations of the same region of "blank sky" are consistent with the statistical uncertainties except when there is clear evidence of solar wind charge exchange emission. We use the blank sky observations to show that contamination by SWCX emission is a strong function of the solar wind proton flux, and that observations through the flanks of the magnetosheath appear to be contaminated only at much higher solar wind fluxes. We have also developed a spectral model of the residual soft proton flares, which allows their effects to be removed to a substantial degree during spectral fitting.

Kuntz, K. D.↗

A Search for Meteor Shower Signatures in the LDEF IDE Data

For 346 days after the deployment of the LDEF satellite on April 7, 1984, the tape recorder belonging to the Interplanetary Dust Experiment (DE) stored information on over 15,000 impacts made by submicron and larger-size particles on its metal oxide silicon (MOS) detectors. These detectors were mounted on trays facing in six orthogonal directions - LDEF ram and trailing edge, the poles of the LDEF orbit (north and south), and radially inward (towards the Earth) and outward (towards space). The 13.1 second time resolution provided by the IDE electronics, combined with the high sensitivity of the MOS detectors and large collecting area (approximately 1 sq.m) of the experiment, conclusively showed that the small particle environment at the LDEF altitude of 480 km was highly time-variable, with particle fluxes spanning over four orders of magnitude. A large number of the 15,000 impacts recorded by IDE occurred in groups, which were of two types - the spikes, single, isolated events of high intensity and the multiple orbit event sequences (MOES), which were series of events separated in time by integer multiples of the LDEF orbital period. Even though the spikes were generally more intense, the MOES could be quite long-lived, some lasting for many days. A previous paper by Cooke et al. attributed the MOES to impacts by man-made debris particles in orbits intersecting that of LDEF. The 20 day longevity of one of these events - termed the May Swarm - led to the suggestion that the debris particles must be con- stantly replenished by their source, as the orbits of micron sized particles will rapidly decay under the influence of radiation pressure and other non-gravitational forces, entering Earth's atmosphere after only a few revolutions. However, the date of onset of the May Swarm (May 22) and the long duration of this event may indicate a possible correlation with the annual Arietid meteor shower, which peaks around June 8. As this seemed to hold the promise of a less artificial explanation than a satellite or rocket body continuously dribbling debris, it was decided to take a fresh look at parts of the IDE data set in an attempt to detect meteor showers within the impact record.

Cooke, William J.↗

Determination of the geometrical factor and of the spatial distributions of particles for a cosmic ray telescope using a Monte Carlo approach

A program is presented which uses a Monte Carlo technique to compute the geometrical factor of a detector, and the spatial and angular distributions of simulated particles at designated layers within the detector. As the program is written, each layer is assumed to be rectangular, parallel to every other layer with its edges parallel to the edges of every other layer, and centered about a common axis. This program is written in Fortran 4 for the IBM 360 computers and is currently being run under the Fortran 4 (h) compiler. Same features such as the subroutine ERRSET, RANDU, and REMTIM and the type declarations REAL *8 and LOGICAL *1 may need to be changed for use with a different computer system. The use of input data cards, and a sample data set are presented. Lists of the symbol definition, card images of the FORTRAN object deck and subroutines are included along with a flow diagram.

Hemmer, M.↗

Recent progress in the development of transition radiation detectors

Transition-radiation detectors have been used in several recent cosmic-ray experiments for particle identification at energies E/mc-squared of at least about 1000. In order to optimize the design of such detectors and to use them for energy measurements over a broad energy range, it is necessary to study the details of the transition-radiation process. Experimental results are presented which test the theoretical predictions more precisely and at higher energies than in previous experiments. The dependence of the interference pattern in the frequency spectrum on the radiator dimensions is studied, and the total transition-radiation yield generated by electrons in various radiators is measured over a very wide energy range, from 5 to 300 GeV. The significance of the individual experimental parameters in the design of transition radiation detectors is reviewed, and the characteristics of transition-radiation detectors capable of measuring particle energies over the range E/mc-squared from about 300 to 100,000 are discussed.

Cherry, M. L.↗

Particle concentration in the asteroid belt from Pioneer 10

The spatial concentration and size distribution for particles measured by the asteroid/meteoroid detector on Pioneer 10 between 2 and 3.5 AU are presented. The size distribution is from about 35 micrometers to 10 centimeters. The exponent of the size dependence varies from approximately -1.7 for the smallest to approximately -3.0 for the largest size measured.

Soberman, R. K.↗

Systematics of heavy ion enhancements in solar flares

Using Lexan and glass detectors, the composition of solar particles with atomic number 2 or greater was determined as a function of energy from approximately 0.2 to 50 MeV/nucleon in four flares of quite different intensity and during a time when the sun was nearly quiet. Fe is nearly completely stripped. The enhancement factor increases with atomic number at a given energy but decreases with energy. Heavy element enhancements are detectable at higher energies in stronger flares. They occurred in ancient as well as in present-day flares. We have observed Li and Be in one flare. Incomplete ionization, preferential leakage of heavy ions, energy loss by ionization, and nuclear reactions appear to be involved in solar particle production.

Price, P. B.↗

Change of calibration of diffraction-based particle sizers in dense sprays

A calibration procedure for diffraction-based particle-sizing instruments using multielement detectors is briefly reviewed. The effects of multiple scattering due to dense sprays on the calibration of these instruments are then examined over a range of sprays with Sauter mean diameters from 20 to 55 microns. An empirical scheme to correct for changes in calibration due to dense sprays or other scattering media is presented.

Dodge, L. G.↗

Manipulator For A Vacuum Chamber

Rotary seal provides for external actuators. Positioner in vacuum employs four actuators; up/down, horizontal rotary, horizontal, and vertical rotary. External up/down and azimuthal actuators drives shaft entering vacuum chamber through sliding and rotating seal. Placement of actuator motors outside vacuum chamber reduces heat-removal load on system. Atop 2.5-cm-diameter shaft is stage supporting masses as great as 15 kg. Small motors on stage provide horizontal translation and rotation in vertical plane. Manipulator developed for calibrating plasma detectors by subjecting them to particle beams in vacuum. Standard, commercially available parts used.

Hunsaker, F.↗

The Ulysses dust experiment

The Ulysses dust experiment is intended to provide direct observations of dust grains with masses between 10 exp -16 g and 10 exp -6 g in interplanetary space, to investigate their physical and dynamical properties as functions of heliocentric distance and ecliptic latitude. Of special interest is the question of what portion is provided by comets, asteroids, and interstellar particles. The investigation is performed with an instrument that measures the mass, speed, flight direction, and electric charge of individual dust particles. It is a multicoincidence detector with a mass sensitivity 10 exp 6 times higher than that of previous in situ experiments which measured dust in the outer solar system. The instrument weighs 3.8 kg, consumes 2.2 W, and has a normal data transmission rate of 8 bits/s in nominal spacecraft tracking mode. On 27 October 1990 the instrument was switched-on. The instrument was configured to flight conditions and science data collection started immediately. In the period to 13 January 1991, at least 44 dust impacts have been recorded. Flux values are given covering the heliocentric distance range from 1.04 to 1.7 AU.

Gruen, E.↗

The Ulysses dust experiment

The Ulysses dust experiment is intended to provide direct observations of dust grains with masses between 10(exp -16) g and 10(exp -6) g in interplanetary space, to investigate their physical and dynamical properties as functions of heliocentric distance and ecliptic latitude. Of special interest is the question of what portion is provided by comets, asteroids and interstellar particles. The investigation is performed with an instrument that measures the mass, speed, flight direction, and electric charge of individual dust particles. It is a multicoincidence detector with a mass sensitivity 10(exp 6) times higher than that of previous in-situ experiments which measured dust in the outer solar system. The instrument weighs 3.8 kg, consumes 2.2 W, and has a normal data transmission rate of 8 bits/s in nominal spacecraft tracking mode. On 27 Oct. 1990 the instrument was switched on. The instrument was configured to flight conditions, and science data collection started immediately. At least 44 dust impacts had been recorded by 13 Jan. 1991. Flux values are given covering the heliocentric distance range from 1.04 to 1.7 AU.

Gruen, E.↗

Simulation of the ATIC-2 Silicon Matrix for Protons and Helium GCR Primaries at 0.3, 10, and 25 TeV/Nucleon

The energy deposition distribution for protons and helium galactic cosmic ray primaries at 0.3, 10, and 25 TeV/nucleon in the ATIC-2 silicon matrix detector are simulated with GEANT4. The GEANT3 geometrical model of ATIC developed by the University of Maryland was combined with a GEANT4 application developed for the Deep Space Test Bed (DSTB) detector package. The new code included relatively minor modifications to completely describe the ATIC materials and a more detailed model of the Silicon Matrix detector. For this analysis all particles were started as a unidirectional beam at a single point near the center of the Silicon Matrix front surface. The point was selected such that each primary passed through at least two of the overlapping silicon pixels.

Watts, J.↗

Characterization of the RaD-X Mission Instruments

The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission, launched on 25 September 2015, provided dosimetric measurements above the Pfotzer maximum. The goal of taking these measurements is to improve aviation radiation models by providing a characterization of cosmic ray primaries, which are the source of radiation exposure at aviation altitudes. The RaD-X science payload consists of four instruments. The main science instrument is a tissue-equivalent proportional counter (TEPC). The other instruments consisted of three solid state silicon dosimeters: Liulin, Teledyne total ionizing dose (TID) and RaySure detectors. To properly interpret the measurements, it is necessary to evaluate how the payload affects the radiation environment of the detectors. In addition, it is necessary to evaluate how the detectors react to the different particles impacting them. We present the results of the Geant-4 simulations of the interaction of the different radiations with the payload and the instruments. We show how it affect the measurements, and which instruments are better suited for future missions

Gronoff, Guillaume↗

The Moon Burst Energetics All-sky Monitor (MoonBEAM)

MoonBEAM is a SmallSat concept placed in cislunar orbit developed to study the progenitors and multimessenger/multiwavelength signals of transient relativistic jets and outflows and determine the conditions that lead to the launching of a transient relativistic jet. The distinguishing advantage of MoonBEAM is the instantaneous all-sky coverage, maximizing the gamma-ray transients observations and providing upper limits for nondetections. Gamma-ray observatories in low Earth orbit are not able to survey the entire sky at a given time due to Earth blockage as well as detector downtime from the high particle activity in the South Atlantic Anomaly region. The long baseline provided from a cislunar orbit, allows MoonBEAM to constrain the localization annulus when combined with a gamma-ray instrument in low Earth orbit utilizing the timing triangulation technique. Improving the localization precision of a gamma-ray burst aids the gravitational wave follow-up community in reducing the region needed to be searched to locate and identify the afterglow and kilanova emission. Furthermore, by providing a different vantage point for a gamma-ray detection, MoonBEAM can help extend the gravitational wave detection horizon by increasing the confidence of a simultaneous marginal gravitational wave signal. Through the all-sky coverage, MoonBEAM will also provide insight into the conditions that lead to a successful relativistic jet, instead of a shock breakout event, or a completely failed jet in the case of core collapse supernovae.

Gamma-ray Bursts↗

High Energy Particle Excitations as a Measure of Electronic Crosstalk in MODIS and VIIRS VIS/NIR Bands

The MODIS instruments aboard the Terra and Aqua satellites and the VIIRS instruments aboard the SNPP and NOAA-20 satellites each contain several arrays of Si detectors that measure Earth-reflected radiance in the visible and near-infrared spectral range. Even in the absence of incident light, the Si detectors are occasionally excited by high energy charged particles that pass through the spacecraft. These particle radiation events are, fortunately, infrequent enough that they do not lead to significant degradation of the detectors and they do not have a significant impact on the Earth scene radiance images. On the other hand, they are frequent enough that the cumulative data from many years on orbit may provide valuable diagnostic information about the sensors. In this paper, we provide some basic statistics on the frequency and magnitude of the particle excitation events for MODIS and VIIRS and explore the usefulness of this data as a measure of electronic crosstalk. Large amounts of crosstalk can degrade the quality of the Earth images, so it is crucial to have methods to characterize and correct for it on-orbit, which has previously been done for MODIS using lunar image analysis. The particle excitations can manifest as single-pixel spikes in the otherwise dark space view background, which may be an ideal source for evaluating crosstalk. We derive crosstalk coefficients between the NIR band detectors of Terra MODIS, and compare them to coefficients previously derived from lunar observations. The same approach is applied to SNPP VIIRS, which does not show any significant electronic crosstalk. While the HgCdTe detectors used in the MODIS and VIIRS infrared bands can also be excited by particle radiation, the magnitudes of the excitations are much smaller compared to the Si detectors and in general are not large enough to be useful for examining crosstalk.

MODIS↗

Studies of the ionization states of solar and galactic cosmic ray heavy nuclei

Enhancement of abundances of heavy nuclei (e.g., Mg, Si, and Fe) at low energies relative to solar photospheric abundances and anomalously high abundances of iron relative to oxygen nuclei at low energies were recently discovered in solar energetic particles studied at low energy. These phenomena are not understood at present. The proposed experiment is designed to study the recently discovered anomalous component of low energy galactic cosmic ray ions of C, N, O, Ne, and Ca to Fe of energy 5- to 10-million electron volts per atomic mass unit in regard to their ionization states, composition, and intensity, and to study the ionization states of heavy elements from oxygen to iron in energetic solar particles emitted during flare events. The same detector system will serve for both studies, with the second objective being given priority if there are any solar particle events during the mission.

Biswas, S.↗

Proton-induced radiation damage in germanium detectors

High-purity germanium (HPGe) detectors will be used in future space missions for gamma-ray measurements and will be subject to interactions with energetic particles. To simulate this process, several large-volume n-type HPGe detectors were incrementally exposed to a particle fluence of up to 10 to the 8th protons/sq cm (proton energy: 1.5 GeV) at different operating temperatures (90 to 120 K) to induce radiation damage. Basic scientific and engineering data on detector performance were collected. During the incremental irradiation, the peak shape produced by the detectors showed a significant change from a Gaussian shape to a broad complex structure. After the irradiation, all detectors were thoroughly characterized by measuring many parameters. To remove the accumulated radiation damage, the detectors were stepwise-annealed at temperatures below 110 C, while kept in their specially designed cryostats. This study shows that n-type HPGe detectors can be used in charged-particle environments as high-energy resolution devices until a certain level of radiation damage is accumulated and that the damage can be removed at moderate annealing temperatures and the detector returned to operating condition.

Brueckner, J.↗