Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Arbitrage and Capacity Firming in Coordination with Day-Ahead Bidding of a Hybrid PV Plant

A hybrid PV plant (HPP) combines a photovoltaic (PV) plant with a battery energy storage system (BESS), which is considered a promising step towards the future of renewable power plants by the U.S. Department of Energy. When the renewable penetration reaches a significant level, a hybrid PV plant can bid in as a controllable thermal plant in the future electricity market. In this study, a bidding and BESS scheduling model is proposed for the HPP. The robust optimization (RO) technique has been utilized to identify the worst-case scenario of uncertainties during the bidding process. To address the overly conservative issue of the single-stage RO, we have decoupled the BESS schedule for arbitrage and PV capacity firming by a two-stage RO formulation. By comparing the output of single-stage RO and two-stage RO, the two-stage RO bids and schedules in a more aggressive manner, which increases the income of HPP. Also, the penalty of under-generation is considered in our model so that the day-ahead bidding decision and arbitrage schedules can be adjusted based on the potential UNDER-GENERATION penalty. Because the proposed model is non-convex and contains multi-stages, the Column-and-Constraint Generation (C&CG) algorithm is applied to the model as the solution. The proposed model has shown better economic performance compared to a state-of-art single-stage bidding method in case studies.

BESS scheduling↗

Susceptibility to polarization type potential induced degradation in commercial bifacial p-PERC PV modules

Potential induced degradation (PID) is a reliability issue affecting photovoltaic (PV) modules, mainly when PV strings operate under high voltages in hot/humid conditions. Polarization-type PID (PID-p) has been known to decrease module performance quickly. PID-p can be reduced or recovered under the light in some cases, but this effect, as expected, would be less pronounced on the rear side of bifacial PV modules receiving lower irradiance. As bifacial PV modules are projected to dominate the PV market within the next 10 years, it is crucial to understand the PID-p issue in bifacial modules better. In this study, we performed indoor PID testing to induce PID-p on 14 commercial bifacial p-PERC modules with three different module constructions from three manufacturers. Here, four rounds (+ve and –ve polarities for front and rear sides) of PID testing are done at 25°C, 54% relative humidity (RH) for 168 h using the aluminum foil method. Each module side (front cell side and back cell side) is tested individually under both negative and positive voltage bias. The results show that the highest degradation of 32% in maximum power (Pmax) at standard test conditions (1000 W/m 2 ) and 51% at low irradiance (200 W/m 2 ) has been observed in some cases. Recovery under sunlight is also done, and outcomes show a near-complete recovery in Pmax. This study presents an extensive experimental methodology and a detailed analysis to systematically and simultaneously/sequentially evaluate multiple construction types of bifacial modules to the PID-p susceptibility and recovery.

14 SOLAR ENERGY↗

Using Artificial Soiling to Rank Anti-Soiling Coatings for Arid Climates

A simple method to evaluate (e.g., screen and rank) the performance of coatings that are fully or partially anti-soiling (AS) is lacking within the PV industry. Artificial soiling may be used as a rapid and economical assessment approach, offering an efficient alternative to time-intensive, site-specific field testing. In this study, we present an artificial soiling method to replicate the anti-soiling performance rankings of two groups of coated glass samples supplied by two manufacturers (group C with CA, CP, and CS coatings; group A with AC coating). These are compared to field aging in two climates: semi-arid Lemoore, California over 4 months, and the hot desert in Mesa, Arizona over 7 months. Both field and indoor performance ranking utilize the transmittance ratio, defined as the optical transmittance between a coated sample and an uncoated reference in each group, as an evaluation metric to assess the effectiveness of the artificial soiling approach in replicating field soiling. It is critical to mimic the dominant field meteorological conditions associated with soiling-prone days and vulnerable times of day during the soiling season. Our results reveal that the use of artificial soiling for field performance ranking among coatings strongly depends on the soil type (composition and particle distribution), dust surface density, and prevalent environmental factors (wetting saturation by humidity, dew condensation extent, and prior weathering history of the coating). The similar rank order relative to the field suggests that the artificial soiling approach presented may be used for down-selecting anti-soiling coatings prior to prolonged field validation.

14 SOLAR ENERGY↗

How Should Researchers Measure Perovskite-Based Monolithic Multijunction Solar Cells’ Performance? A Calibration Lab's Perspective

Perovskite multijunctions (PVSK MJs) have made remarkable progress with monolithic PVSK/PVSK tandems surpassing the efficiency of single-junction (1 J) PVSK cells and PVSK/Si cells reported to exceed the 30% efficiency mark. These efficiencies are reported at standard test conditions (STC), established by the photovoltaic (PV) community to facilitate comparison between devices and technologies. Herein, it is discussed why an accurate STC performance measurement for a MJ is more complicated than for a 1 J cell and the special aspects to be considered when measuring the current-voltage characteristics and the performance of PVSK-containing MJ cells are emphasized. It is discussed why a spectrally adjustable solar simulator is needed and the sequence of accurate performance measurement, namely measurement of the spectral response of each junction, adjustment of the spectrum, and appropriate protocols for measuring the power output of the device at STC, is presented. For all these, common errors and pitfalls that sometime lead to misleading interpretation of the results are presented, and the methods to evaluate the accuracy of the data when a spectrally adjustable solar simulator is not available are recommended. Finally, first step is taken toward recommending performance measurement approaches when high throughput is required as will eventually be in a production line.

14 SOLAR ENERGY↗

Evaluating Utility-Scale PV-Battery Hybrids in an Operational Model for the Bulk Power System

Systems that combine solar photovoltaic and battery energy storage technologies (PV-BES) are increasingly being proposed and deployed on the bulk power system. The operations and value of PV-BES systems have been extensively studied from the project developer's perspective through analyses that maximize plant-level revenue. However, PV-BES hybrids' operational characteristics are seldom studied from the perspective of bulk power system operators, who seek to optimize the performance of a suite of generation and storage assets that are connected via the transmission network. This work presents modeling approaches for representing and evaluating PV-BES hybrids in a model that optimizes operations across the bulk power system. Its novel contributions include demonstrating a technique to modify a unit commitment and dispatch model to represent the operational synergies of PV-BES hybrids. In particular, we describe the challenges and an approach for representing so-called DC-coupled PV-BES - which utilize a single bi-directional inverter - as a dispatchable resource in a commercial, production cost model (PCM), PLEXOS. We demonstrate this technique in a PCM study of the Los Angeles Department of Water and Power (LADWP) test system, by replacing existing PV and battery generators on the test system with our PV-BES hybrids. We then pursue scenario analysis that is designed to isolate the various drivers of operational strategies for DC-coupled PV-BES hybrids, including the nature of coupling, PV penetration on the system, and varying inverter loading ratios (or degrees of over-sizing of the PV field). Results from the analysis include utilization profiles for the PV DC energy across available pathways, dispatch profiles for the battery component, and the hybrid technologies' impacts on system-wide production costs. The approach presented in this paper can be used in any PCM that is looking to study PV-BES hybrids as a resource in different power system configurations and services.

14 SOLAR ENERGY↗

AI-Driven Smart Community Control for Accelerating PV Adoption and Enhancing Grid Resilience

The U.S. Department of Energy (DOE) has launched a Connected Communities program that supports projects that expand DOE's network of grid-interactive, efficient building communities nationwide. As an early pilot of Connected Communities, the National Renewable Energy Laboratory (NREL) and its partners have developed and demonstrated a community-scale, hierarchical control solution to address the potential grid issues arising from high penetration of solar photovoltaics (PV) as well as to improve grid reliability and resilience in this residential community. A field pilot study has been performed at an affordable housing development called the Basalt Vista Community, which was built for school teachers and other professionals in the local workforce and represents an autonomous energy grid with all-electric, energy-efficient homes. With no natural gas line in the community, this is the first all-electric net-zero community in rural Colorado. In the field pilot study, NREL has validated the performance of the hierarchical control solution, which consists of NREL's foresee home energy management systems (HEMS) and community aggregators, in increasing demand flexibility and self-consuming PV, reducing potential over-voltages, and supporting critical loads during emergency events. In this presentation, we will present the methodology, simulation and field pilot results, and lessons learned from the project.

all-electric community↗

Hardware-in-the-Loop Testbed for Cyber-Physical Security of Photovoltaic Farms

In the last decades, modem grids with distributed energy resources, such as photovoltaic (PV) farms, are increasingly vulnerable to cyber-attacks that seriously affect the stability and performance of the power system. While cyber-physical security of smart grids is extensively studied, most of the existing work focuses on the grid level and neglects the modeling and features of device-level power electronics converters (PECs). Furthermore, establishing a high-fidelity simulation testbed that can simulate harmonic frequencies of the PV farm is in urgent need. In this paper, a high-fidelity and real-time hardware-in- the-loop testbed is built to simulate the harmonics of power electronics converters for cyber-physical security of PEC-enabled PV farms. Based on this testbed, the impact of typical cyber-attacks and physical faults on the PV converter can be analyzed, thus providing a foundation for cyber-attack detection, root cause diagnosis, and resilient control to mitigate the adverse effects of cyber-attacks.

14 SOLAR ENERGY↗

Flat-plate solar array project. Volume 1: Executive summary

In 1975, the U.S. Government contracted the Jet Propulsion Lab. to develop, by 1985, in conjunction with industry, the photovoltaics (PV) module and array technology required for widespread use of photovoltaics as a significant terrestrial energy source. As a result, a project that eventually became known as the Flat Plate Solar Array (FSA) Project was formed to manage an industry, university, and Government team to perform the necessary research and development. The original goals were to achieve widespread commercial use of PV modules and arrays through the development of technology that would allow them to be profitably sold for $1.07/peak watts (1985 dollars). A 10% module conversion efficiency and a 20 year lifetime were also goals. It is intended that the executive summary provide the means by which one can gain a perspective on 11 years of terrestrial photovoltaic research and development conducted by the FSA Project.

Callaghan, W.↗

Flexible copper-indium-diselenide films and devices for space applications

With the ever increasing demands on space power systems, it is imperative that low cost, lightweight, reliable photovoltaics be developed. One avenue of pursuit for future space power applications is the use of low cost, lightweight flexible PV cells and arrays. Most work in this area assumes the use of flexible amorphous silicon (a-Si), despite its inherent instability and low efficiencies. However, polycrystalline thin film PV such as copper-indium-diselenide (CIS) are inherently more stable and exhibit better performance than a-Si. Furthermore, preliminary data indicate that CIS also offers exciting properties with respect to space applications. However, CIS has only heretofore only produced on rigid substrates. The implications of flexible CIS upon present and future space power platforms was explored. Results indicate that space qualified CIS can dramatically reduce the cost of PV, and in most cases, can be substituted for silicon (Si) based on end-of-life (EOL) estimations. Furthermore, where cost is a prime consideration, CIS can become cost effective than gallium arsenide (GaAs) in some applications. Second, investigations into thin film deposition on flexible substrates were made, and data from these tests indicate that fabrication of flexible CIS devices is feasible. Finally, data is also presented on preliminary TCO/CdS/CuInSe2/Mo devices.

Armstrong, J. H.↗

Analysis and Validation of Spectral Irradiance Simulations for 75 kW Bifacial Solar Test Field

This work investigates how the spectrum of irradiance incident on the rear of bifacial modules impacts their performance. Light incident on the rear of bifacial modules can be reflected from the ground, mounting structures, and other nearby objects, causing both the intensity and spectrum to be modified. As a result, PV cells and sensors with different spectral responses report different values for the rear irradiance, leading to increased uncertainty when modeling performance. Here, we calculate the spectral irradiance incident on the rear of modules through raytrace simulations and validate with measured field data collected from a 75kW single-axis-tracked bifacial test site. Spectral responses for different sensors and PV cells are applied and compared with field measurements for four days. Based on these results, a method for improving non-spectral simulations is proposed. In addition, a linear regression is applied to the modeled spectral results as a method to gain insight into the contributions of ground reflected light to total rear irradiance.

bifacial photovoltaics↗

Optimizing Bifacial PV Systems (Q3 FY2020 Project Report)

This project has four main technical objectives. Develop and improve bifacial performance models by adding the capability to evaluate electrical behavior and performance of bifacial modules and arrays under realistic field conditions including irradiance variability caused by racking, module frame, and position in the array. Instrument and monitor performance of fielded bifacial systems to validate performance models and to measure, analyze and publish on bifacial energy gain. These should include both research and commercial bifacial systems and cover a variety of deployment applications. Evaluate optimal bifacial system designs using simulations leveraging high performance computing, and also using full sized and miniaturized experimental field deployments. Establish and contribute to international test standards for bifacial system performance, testing, and safety, and work with the community to establish installation and siting best practices.

14 SOLAR ENERGY↗

Evaluating Cell Temperature Models and the Effect of Wind Speed in PV System Capacity Testing: Preprint

Capacity testing is a routine procedure for assessing a photovoltaic system's performance relative to expectations. The most common test method involves fitting a regression model that predicts system output power using operating weather conditions including wind speed. Structural modifications to the regression model to incorporate wind in different ways improved the model's ability to fit measured system performance, but the observed improvements were small and unlikely to change the result of a capacity test. However, the results showed that the choice of reporting wind speed and inclusion or exclusion of wind speed in the performance model used as the test benchmark can significantly change the test result.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Collaborative R&D with First Solar on Understanding Performance Limitations in CdTe (Project 1 "CdTe" - Mods 0-10, 13, 14-A1, 17)

This CRADA involves analyses on a variety of CdTe and CdTe-PV related materials, test structures, and solar cells produced at FSLR or NREL. Single-crystal (sx) material will be primarily MBE grown and provided by FSLR. Joint activities are focused on establishing the appropriate quality metrics as a basis for high performing sx devices and to study the dopability of the material. Polycrystalline (px) materials will be provided by NREL, FSLR, or fabricated jointly. Px activities are focused on the characterization of performance limiting mechanisms including bulk defects, grain boundaries, and the hetero-interface. A combination of growth, characterization, and theory will be applied. Analysis will include techniques that are well established in CdTe research at NREL (e.g., LIV/DIV/CV, AS/DLTS, LTPL, TRPL) as well as techniques that have not been widely applied to the PV part of CdTe technology (e.g., PCD, CL, uPL, SE).

14 SOLAR ENERGY↗

Comparative study on the overall energy performance between photovoltaic and Low-E insulated glass units

In this report a novel semi-transparent building integrated photovoltaic (BIPV) laminate was developed and introduced in this paper. It was produced by cutting standard mono-crystalline silicon solar cells into small strips and then making electrical connections between each strip before laminating the cells between two layers of glass. The overall energy performance and energy saving potential of the BIPV insulated glass unit (IGU) under real world conditions were identified through a side by side comparative study. Compared to the reference IGU, the BIPV IGU had lower solar heat gain coefficient (SHGC) but much higher U-factor. The average HVAC electricity saving of the BIPV IGU was about 10% relative to the reference IGU. Daylighting measurement and analysis were carried out to evaluate the trade-offs associated with the BIPV IGU between daylight, glare, and lighting energy use. The results indicated that the BIPV IGU is better than the reference IGU in reducing discomfort glare. However, if the most conservative viewpoint near the window is used for the assessment, a lower transmittance BIPV IGU is required to bring the overall discomfort levels below the perceptible level. Lastly, the net energy saving potential associated with the novel BIPV IGU was identified based on the power, thermal and daylighting performance. On average, the BIPV IGU saved 16.8% of the total electricity use of the room. Further studies and improvement on the energy conversion efficiency of solar cells, the optimal transmittance as well as the thermal properties would make this technology more energy-efficient and affordable.

14 SOLAR ENERGY↗

LCOE*: Re-Thinking LCOE for Photovoltaic Systems

Solar industry is working towards reducing the levelized cost of energy (LCOE). The LCOE formulation includes various implicitly connected cost and physical design parameters. This entails complex cost analyses by economists, and electrical analysis and energy yield calculations of solar farms by device physicists/technologists. The standard formulation requires a constant exchange of information to optimize the design of a specific farm. In this paper, we present a fundamental reformulation of LCOE (in terms of LCOE*) to deconvolve the cost vs. energy yield analysis so that economists and technologists can work independently towards minimizing LCOE. We validate our LCOE* formulation by comparing LCOE calculated by the traditional vs. new method. We further provide a global analysis of LCOE* as an illustrative example. This LCOE* will accelerate new technology development (e.g. bifacial PV) by allowing a rapid and transparent analysis of its cost-performance trade-off.

14 SOLAR ENERGY↗

Spectral Rear Irradiance Testing and Modeling for Degradation and Performance of Solar Fields

This work investigates how the spectrum of irradiance incident on the rear of solar modules impacts the degradation and performance of backsheets. We model the spectral irradiance incident on the rear of modules through raytrace simulations and validate with measured field data collected from a 75kW single axis-tracked bifacial test site. A generic equation to estimate relative degradation is proposed, and we show that current acceleration factors for UV damage in chambers can be sub-estimate up to 4.5% absolute from the usually assumed 10% dosage on the rear surfaces.

bifacial performance↗

Demonstration of a modeling toolkit for the design of building electrical distribution systems

The deployment of building equipment (e.g., lighting, security) and miscellaneous electrical loads that fundamentally require DC power for operation is increasing. Powering these DC loads has traditionally required an AC/DC converter, but the installation of photovoltaic (PV) and battery energy storage systems that primarily produce DC power eliminates the need for AC/DC converters at each end-device. However, analyzing system energy efficiency and cost for different electrical distribution architectures can be challenging as software tools that support this are not readily available. This paper presents preliminary results from a laboratory verification of the Building Electrical Efficiency Analysis Model (BEEAM) toolkit that was developed to address this gap. Three different eight-luminaire lighting systems comprised of market-available products were designed and modeled: one that used traditional AC distribution, a second that used a hybrid AC -to- centralized DC electrical distribution architecture, and a third that used a hybrid AC -to- distributed DC architecture. Notably, AC/DC conversions are required in all three systems. BEEAM models for LED drivers as well as Power-over-Ethernet (PoE) switches were created using laboratory characterization data. The lighting systems were simulated in Modelica, and the results were compared with each other and physics-based expectations. Simulation results show that PoE system energy efficiency is highly dependent on both device specification (e.g., LED driver and PoE switch efficiency) and system architecture (e.g., PoE switch loading) choices, as expected. For the products and system architectures selected for this study, the two DC systems were found to be less efficient than the AC system over the course of typical operation. In future work, simulation results will be compared with laboratory measurements to validate the usefulness of this software for design, and lighting systems with integrated PV and battery energy storage will be simulated to quantify the energy performance improvements that result from the elimination of some AC/DC converters.

Waghale, Anay S.↗

Testing Asoleyo Decorative Solar Cell and Modules: Cooperative Research and Development, CRADA Number CRD-20-16732 (Final Report)

Team Asoleyo is transforming the utilitarian rectangular grid that dominates the visual style of standard solar panels by re-designing solar cells’ silver contact grid using principles of symmetry, rhythm, and line. Our designs use well-established manufacturing equipment, techniques, and materials, achieving similar manufacturing costs but far superior aesthetic effect- without the need for additional layers or occlusion. This project will test new decorative PV Cell front contact designs, individually and interconnected within modules, for their performance characteristics.

14 SOLAR ENERGY↗