Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV System Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Updated sustainability status of cadmium telluride thin‐film photovoltaic systems and projections

This paper provides a comprehensive assessment of the up-to-date life-cycle sustainability status of cadmium-telluride based photovoltaic (PV) systems. Current production modules (Series 6 and Series 7) are analyzed in terms of their energy performance and environmental footprint and compared with the older series 4 module production and current single-crystalline Silicon (sc-Si) module production. For fixed-tilt systems with Series 6 modules operating under average US irradiation of 1800 kWh/m 2 /year, the global warming potential (GWP) is reduced from 16 g CO 2eq /kWh in Series 4 systems to 10 CO 2 eq /kWh in Series 6 systems. For operation in US-SW irradiation of 2300 kWh/m 2 /year, the GWP is reduced from 11 to 8 CO 2eq /kWh and for 1-axis tracking systems operating in Phoenix, Arizona, with point-of array irradiation of 3051 kWh/m 2 /year the GWP is reduced to 6.5 CO 2eq /kWh. Similar reductions have happened in all environmental indicators. Energy payback times (EPBT) of currently installed systems range from 0.6 years for fixed–tilt ground–mounted installations at average US irradiation at latitude tilt installations to 0.3 years for one-axis trackers at high US-SW irradiation, considering average fossil-fuel dominated electricity grids with fuel to electricity conversion efficiency of 0.3. The resulting energy return on energy investment (EROI) also depends on the conversion efficiency of the electricity grid and on the operation life expectance. For a 30-year operational life and grid conversion efficiency of 0.3, EROI ranges from 50 (at US average irradiation) to 70 for US-SW irradiation. The EROI declines with increased grid conversion efficiency; for CdTe PV operating in south California with grid conversion efficiency of 49%, the EROI is about 50 and is projected to fall to 30 when the state's 2030 target of 80% renewable energy penetration materializes. Material alternatives that show a potential of further reductions in degradation rates and materials for enhanced encapsulation that would enable longer operation lives have also been investigated. A degradation rate of 0.3%/year, which has been verified by accelerated testing, is assumed in 30-year scenarios; this is projected to be reduced to 0.2%/year in the near-term and potentially to 0.1%/year in the longer term. With such low degradation rates and enhanced edge-sealing, modules can last 40- to 50-years. Consequently, all impact indicators will be proportionally reduced while EROI will increase. This detailed LCA was conducted according to ISO standards and IEA PVPS Task 12 guidelines. Furthermore, the study revealed that the choices of system models, methods and temporal system boundaries can significantly impact the results and points out to the need to include assumptions regarding these choices in the “transparency in reporting” requirements listed in the IEA PVPS Task 12 Guidelines.

14 SOLAR ENERGY↗

Duty-Cycle Predictive Control of Quasi-Z-Source Modular Cascaded Converter Based Photovoltaic Power System

A duty-cycle predictive control is proposed for dc grid integration of front-end isolated quasi-Z-source modular cascaded converter (qZS-MCC) photovoltaic (PV) power system. The post-stage qZS half-bridge dc-dc converter deals with PV maximum power point tracking, dc grid integration, and dc-link voltage balance; whereas, the front-end isolation converters operate at a constant duty cycle of 50%. Thus, it saves control hardware resources while overcoming challenges from PV-panel voltage variations and dc-bus voltage limit. The proposed control uses the derived circuit model to predict the global active-state duty cycle for grid-connected current control and predict the shoot-through duty cycles for dc-link voltage balance, achieving a fast and accurate tracking target. The proposed control method has advantages of: i) eliminating weighting factors that exist in conventional model predictive control (MPC), ii) no sophisticated loop parameters design that exists in proportional-integral (PI) control, iii) operating at constant switching frequency that is different from the conventional MPC with variable switching frequency. Simulation and experimental tests are carried out to verify the effectiveness of the proposed control method and compare with the PI-based control system.

42 ENGINEERING↗

Iterative and Self-Consistent Estimation of Degradation and Soiling Loss in PV Systems - A Case Study

In many parts of the world, soiling is a significant loss mechanism for PV energy production. Methods for accurately quantifying historical and current soiling losses are needed. Furthermore, state-of-the-art methods to estimate degradation rates based on production data do not handle soiling in a satisfactory manner. In order to accurately estimate either of these quantities, it is in many cases helpful to consider their combined effect on PV system performance. In this work we make use of the Combined Degradation and Soiling (CODS) algorithm, which iteratively decomposes time series of daily normalized energy yield into four components: a soiling ratio, a degradation trend, seasonal variations, and noise. We demonstrate the use of the model on field performance data from a utility-scale power plant in a high-soiling environment in the Middle East. We apply the algorithm to the temperature-corrected performance index of the DC power on inverter level, quantifying how soiling varies over time and through the plant. The irradiation-weighted average soiling loss in this plant is 2.3 %, with a median soiling rate of -0.086 %/day. Between the inverters in the site in study, estimated degradation rates range between -0.86 %/year and -0.15 %/year, with a mean rate of -0.48 %/year.

41 EE - Solar Energy Technologies Office (EE-4S)↗

International collaboration framework for the calculation of performance loss rates: Data quality, benchmarks, and trends (towards a uniform methodology)

Abstract The IEA PVPS Task 13 group, experts who focus on photovoltaic performance, operation, and reliability from several leading R&D centers, universities, and industrial companies, is developing a framework for the calculation of performance loss rates of a large number of commercial and research photovoltaic (PV) power plants and their related weather data coming across various climatic zones. The general steps to calculate the performance loss rate are (i) input data cleaning and grading; (ii) data filtering; (iii) performance metric selection, corrections, and aggregation; and finally, (iv) application of a statistical modeling method to determine the performance loss rate value. In this study, several high‐quality power and irradiance datasets have been shared, and the participants of the study were asked to calculate the performance loss rate of each individual system using their preferred methodologies. The data are used for benchmarking activities and to define capabilities and uncertainties of all the various methods. The combination of data filtering, metrics (performance ratio or power based), and statistical modeling methods are benchmarked in terms of (i) their deviation from the average value and (ii) their uncertainty, standard error, and confidence intervals. It was observed that careful data filtering is an essential foundation for reliable performance loss rate calculations. Furthermore, the selection of the calculation steps filter/metric/statistical method is highly dependent on one another, and the steps should not be assessed individually.

14 SOLAR ENERGY↗

Seminar 13 - Advanced Methods for Grid Integration of High-Performance Residential Communities

High-performance residential communities such as net-zero energy (NZE) and NZE-ready communities are emerging across the United States as many cities and states have committed to achieve ambitious energy efficiency and renewable energy goals between now and 2050. The achievement of these goals will transform the nation's communities into the holistic paradigms consisting of pervasive solar photovoltaics (PVs) and other renewable distributed energy resources, energy storage and flexible loads. However, integrating residential communities with high PV penetration may bring many challenges to the grid. For example, during many hours of the year, electric power is flowing out of PV-enabled homes and back into the grid. When this happens simultaneously in many nearby homes, distribution feeder voltage can be raised significantly. Intermittent solar power can also cause voltage flickers, leading to potential damages on both distribution feeder and home appliances. Existing solutions, such as PV curtailment, battery storage, and direct load control, are not able to address all the challenges in a cost-effective way. Better understanding is needed on how to deploy rooftop PV, how to predict building loads, and how to coordinate the homes in a community to enhance grid reliability. This seminar consists of four integral presentations that cover different aspects of a solution to these challenges. First, we will present an automated method to identify the best surfaces to deploy PV and size PV according to the PV penetration goals in a community. Second, we will present a streamlined way to create gray-box building models that are suitable for large-scale building-grid co-simulation. Next, we will present a data-driven method to estimate the end-use energy consumption to better coordinate the behind-the-meter resources to reduce utility cost, provide grid services, and improve renewable energy integration. Lastly, we will present a hierarchical control system that integrates the building models and the estimated non-dispatchable loads into the decision-making process to enhance the reliability and resilience of the residential community. Simulation results from an NZE-ready community in Fort Collins, Colorado will be presented in all four presentations and the guidelines on better grid integration of residential communities will be provided.

14 SOLAR ENERGY↗

A Convolution Neural Network for Voltage Event Classification at a Photovoltaic Inverter

This paper presents a convolutional neural network (CNN) developed to identify voltage events in photovoltaic (PV) inverters. The CNN is trained on synthetic data generated using the IEEE 13-bus distribution feeder model and evaluated on field measured data collected from Energy Northwest’s Horn Rapids Solar, Storage, and Training (HRSST) facility. The study focuses on two common voltage events: faults and voltage sags. The CNN is configured to analyze voltage and current waveforms from three-phase PV systems, demonstrating excellent accuracy during training. Field data from the HRSST facility is employed to assess its real-world performance, where the CNN achieves perfect identification of faults and voltage sags in a sample of nine events. This work highlights the potential of the proposed method to enhance PV protection schemes, providing a robust foundation for improved voltage event detection and grid reliability.

Cornachione, Matthew A.↗

Solar Industry Update (Q2/Q3 2020) [Slides]

Each quarter, the National Renewable Energy Laboratory (NREL) conducts the Quarterly Solar Industry Update, a presentation of technical trends within the solar industry, to the solar office staff. Each presentation focuses on global and U.S. supply and demand, module and system price, investment trends and business models, and updates on U.S. Government programs supporting the solar industry.

14 SOLAR ENERGY↗

Influence of Hybridization on the Capacity Value of PV and Battery Resources

Utility-scale systems that combine solar photovoltaic and battery (PV+battery) technologies are growing in popularity on the U.S. bulk power system. The business case for PV+battery systems depends on both their ability to reduce costs and their ability to generate value synergies associated with the provision of energy, capacity, and ancillary services. Capacity value can constitute a significant portion of the value PV+battery hybrids provide to the grid (e.g., through avoided or deferred capacity) and receive through revenues. Throughout this report, we define capacity value as the monetary value of a plant's contribution towards the planning reserve margin, which ultimately depends on market rules and structures. PV+battery hybrids do not always fit into current market structures because of the interactions between the PV and battery components. Unique considerations for the capacity value of PV+battery hybrids include the disparate nature of participation models for PV and battery technologies in existing market rules and the potential influence of a shared interconnection capacity; limitations imposed by a shared inverter; limited ability to charge the battery in advance of capacity events if charging must be sourced from the coupled PV; and challenges or uncertainties associated with co-optimizing the operations of the PV and battery components. Grid operators are currently considering how market structures can be modified to optimally determine the capacity value provided by PV+battery systems, and the rules of how they are integrated into markets are still being written. As with any resource, poorly designed rules could increase the cost of energy and reduce system reliability, while well-designed rules could allow markets to receive the full benefits hybrid systems can offer without overcompensating them for the services they provide. Well-designed rules for PV+battery systems must consider the unique aspects listed above, while leveraging the commonalities with existing resource types. In this report, we summarize the technical capability and market rules that influence the capacity value of PV+battery systems. We further discuss the potential tradeoffs between computational complexity and accuracy for the various ways in which grid operators can credit PV+battery systems for capacity. Finally, we describe markets for capacity, survey current wholesale market rules applying to PV+battery systems, and provide a snapshot of the current regulatory landscape for PV+battery systems.

14 SOLAR ENERGY↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 99% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

Real-Time Regional PV Spinning Reserve Estimator with AGC Look-Ahead Windows: Preprint

Curtailed PV generation is a zero-marginal cost spinning reserve that can be used for a number of active power control services. However, unlike the traditional spinning reserve providers, i.e., fossil-fueled generators, who have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate forecasts of the PV PHL are essential. A novel reference-control grouping based scaling method has been proposed by NREL to estimate the PV PHL in real-time. This work further enhances the methodology by: 1) improving the model accuracy through machine learning; 2) considering look-ahead windows introduced by the computation and communication latencies; 3) applying the method to regional spinning reserve estimation. A significant performance improvement, over 1.6% of estimation error reduction, has been observed based on real-world data collected by CAISO and PV plant operators.

potential high limit↗

Assessing the New Home Market Opportunity: Case Study and Cost Modeling for Solar and Storage in 2030

In 2020, the United States had a cumulative 19 gigawatts (GWdc) of residential solar photovoltaic (PV) capacity. A growing percentage of these solar installations are paired with battery storage, up from 0.1% in 2015 to 8.1% in 2020. Some states are considering or have already adopted policy mandates to require solar and storage systems. The cost of installing residential solar and battery storage projects remains a barrier to widespread adoption nationwide. For example, the cost of a typical residential retrofit solar and storage system ranges from $\$ 26,153$ to $\$ 37,909$, which is 38% to 100% higher than a standalone PV system.

14 SOLAR ENERGY↗

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frequency Nadir Constrained Unit Commitment for High Renewable Penetration Island Power Systems

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar Industry Update (Q1/Q2 FY2020) [Slides]

Each quarter, the National Renewable Energy Laboratory (NREL) conducts the Quarterly Solar Industry Update, a presentation of technical trends within the solar industry, to the solar office staff. Each presentation focuses on global and U.S. supply and demand, module and system price, investment trends and business models, and updates on U.S. government programs supporting the solar industry.

14 SOLAR ENERGY↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaic Systems

Faults in photovoltaic (PV) systems can seriously affect the efficiency, energy yield, cost, safety, and reliability of PV plants. Condition monitoring of PV plants is, therefore, a very important approach to estimating the health condition of PV modules and power electronics in the system. However, additional hardware for PV system monitoring adds cost to the system's operation; delayed maintenance service also causes additional energy production loss. The Center for Power Electronics Systems (CPES) at the Virginia Polytechnic Institute and State University and Siemens Cooperate Research developed the online impedance measurement for a PV panel self-monitoring and diagnosing technology using the DC-DC converter connected to the panel. Small-signal impedances of a monocrystalline silicon PV panel were modeled and simulated to reflect fault conditions such as the short-circuit, hot-spot, and junction box faults. Modeling and simulation results were validated firstly using a test setup consisting of a solar simulator, a network analyzer, small-signal injectors, and a monocrystalline PV panel rated at 300 W.

14 SOLAR ENERGY↗

Solar and Storage Integration in the Southeastern United States: Economics, Reliability, and Operations

Solar energy has the potential to be a core energy resource for the southeastern United States. To better understand the implications of higher levels of solar PV (27%-43% of total generation capacity) and electricity storage (13%-49% of peak load) would affect electricity system reliability, costs, and operations in the U.S. Southeast, this study sought to address two main questions. First, how would higher levels of solar PV and electricity storage impact the costs, reliability, and operations of electricity systems in the Southeast in 2035? Second, at different levels of solar PV and electricity storage, what are the benefits of operational coordination among utilities in the Southeast, through more efficient regional dispatch and sharing operating reserves? To answer these questions, the study used detailed capacity expansion and dispatch modeling to develop and examine 15 scenarios with different levels of solar PV, electricity storage, and operational coordination, focusing on the year 2035. The study also evaluates the benefits of operational coordination among utilities through more efficient regional dispatch and reserve sharing, at different levels of solar and storage. The study focuses on five balancing regions that cover Alabama, Georgia, Kentucky, North Carolina, South Carolina, Tennessee, and parts of Mississippi and Missouri.

14 SOLAR ENERGY↗

Solar and Storage Integration in the Southeastern United States: Economics, Reliability, and Operations

Solar energy has the potential to be a core energy resource for the southeastern United States. To better understand the implications of higher levels of solar PV (27%-43% of total generation capacity) and electricity storage (13%-49% of peak load) would affect electricity system reliability, costs, and operations in the U.S. Southeast, this study sought to address two main questions. First, how would higher levels of solar PV and electricity storage impact the costs, reliability, and operations of electricity systems in the Southeast in 2035? Second, at different levels of solar PV and electricity storage, what are the benefits of operational coordination among utilities in the Southeast, through more efficient regional dispatch and sharing operating reserves? To answer these questions, the study used detailed capacity expansion and dispatch modeling to develop and examine 15 scenarios with different levels of solar PV, electricity storage, and operational coordination, focusing on the year 2035. The study also evaluates the benefits of operational coordination among utilities through more efficient regional dispatch and reserve sharing, at different levels of solar and storage. The study focuses on five balancing regions that cover Alabama, Georgia, Kentucky, North Carolina, South Carolina, Tennessee, and parts of Mississippi and Missouri.

14 SOLAR ENERGY↗

Frequency-Nadir-Constrained Unit Commitment for Low-Inertia, High-IBR Island Power Systems [Slides]

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

14 SOLAR ENERGY↗