At least 559 records · Page 31

Compression mass gauge testing in a liquid hydrogen dewar

This paper describes testing that was conducted using a mass gauge in a liquid hydrogen environment. The mass gauge, herein referred to as the 'compressibility gauge,' is being developed as a means to accurately determine the mass of liquid contained in a tank in a low-gravity environment. The concept is based on the thermodynamic principle that the pressure of gas or vapor changes when its volume changes. Previous work has been conducted by Southwest Research Institute in collaboration with NASA Lewis Research Center. This consisted of testing the concept with water and other cryogenic simulant fluids. The purpose of conducting liquid hydrogen tests is to test the concept in actual cryogenic conditions, and address hardware issues that arise in fabricating a test article for use in liquid hydrogen.

Jurns, J. M.↗

Cosmic microwave background constraints on secret interactions among sterile neutrinos

Secret contact interactions among eV sterile neutrinos, mediated by a massive gauge boson X (with M X &NestedLessLess; M W ), and characterized by a gauge coupling gX, have been proposed as a mean to reconcile cosmological observations and short-baseline laboratory anomalies. We constrain this scenario using the latest Planck data on Cosmic Microwave Background anisotropies, and measurements of baryon acoustic oscillations (BAO). We consistently include the effect of secret interactions on cosmological perturbations, namely the increased density and pressure fluctuations in the neutrino fluid, and still find a severe tension between the secret interaction framework and cosmology. In fact, taking into account neutrino scattering via secret interactions, we derive our own mass bound on sterile neutrinos and find (at 95 % CL) m s < 0.82 eV or m s < 0.29 eV from Planck alone or in combination with BAO, respectively. These limits confirm the discrepancy with the laboratory anomalies. Moreover, we constrain, in the limit of contact interaction, the effective strength G X to be < 2.8 (2.0) × 10 10 G F from Planck (Planck+BAO). This result, together with the mass bound, strongly disfavours the region with M X ~ 0.1 MeV and relatively large coupling g X ~ 10 -1 , previously indicated as a possible solution to the small scale dark matter problem.

79 ASTRONOMY AND ASTROPHYSICS↗

One dimensional shock initiation of hot isostatically pressed composition B

Twelve one dimensional shock experiments have been carried out on the UK isostatically pressed Composition B (59.5% RDX, 39.5% TNT, 1% wax) comprising of seven sustained pulse experiments and three short shock experiments using the embedded gauge technique at the Los Alamos National Laboratory gas gun facility. The evolution of the reactive growth at and behind the shock front has been measured along with the run to detonation distance. Two low pressure experiments have also been carried out to obtain non-reactive equation of state data. These data have been used to create the Pop plot and Hugoniot states for the UK Comp B. The shock initiation behavior of the UK Comp B has been compared to that of the equivalent US composition. The reactive growth shows a feature that was observed in the US composition in which the wave profiles display a high level of pre-detonation noise. This was hypothesized to be due to a piezoelectric effect in the RDX crystals. The results of these experiments have shown that this effect may be localized in the ε phase at shock pressures in the region of 4.15 GPa and above.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Vehicle-Level Oxygen/Methane Propulsion System Hotfire Testing at Thermal Vacuum Conditions

A prototype integrated liquid oxygen/liquid methane propulsion system was hot-fire tested at a variety of simulated altitude and thermal conditions in the NASA Glenn Research Center Plum Brook Station In-Space Propulsion Thermal Vacuum Chamber (formerly B2). This test campaign served two purposes: 1) Characterize the performance of the Plum Brook facility in vacuum accumulator mode and 2) Collect the unique data set of an integrated LOX/Methane propulsion system operating in high altitude and thermal vacuum environments (a first). Data from this propulsion system prototype could inform the design of future spacecraft in-space propulsion systems, including landers. The test vehicle for this campaign was the Integrated Cryogenic Propulsion Test Article (ICPTA), which was constructed for this project using assets from the former Morpheus Project rebuilt and outfitted with additional new hardware. The ICPTA utilizes one 2,800 lbf main engine, two 28 lbf and two 7 lbf reaction control engines mounted in two pods, four 48-inch propellant tanks (two each for liquid oxygen and liquid methane), and a cold helium system for propellant tank pressurization. Several hundred sensors on the ICPTA and many more in the test cell collected data to characterize the operation of the vehicle and facility. Multiple notable experiments were performed during this test campaign, many for the first time, including pressure-fed cryogenic reaction control system characterization over a wide range of conditions, coil-on-plug ignition system demonstration at the vehicle level, integrated main engine/RCS operation, and a non-intrusive propellant mass gauging system. The test data includes water-hammer and thermal heat leak data critical to validating models for use in future vehicle design activities. This successful test campaign demonstrated the performance of the updated Plum Brook In-Space Propulsion thermal vacuum chamber and incrementally advanced the state of LOX/Methane propulsion technology through numerous system-level and subsystem experiments.

Morehead, Robert L.↗

Fabrication and Test of a 3.7 m Long Support Structure for the LARP Nb3Sn Quadrupole Magnet LQS01

The 3.7 m long quadrupole magnet LQS01 represents a major step of the US LHC Accelerator Research Program (LARP) towards the development of long Nb{sub 3}Sn accelerator quadrupole magnets for a LHC Luminosity upgrade. The magnet support structure is a scale up of the 1 m long Technology Quadrupole TQS design with some modifications suggested by TQS model test results. It includes an aluminum shell pre-tensioned over iron yokes using pressurized bladders and locking keys (bladder and key technology). The axial support is provided by two stainless steel end plates compressed against the coil ends by four stainless steel rods. The structure, instrumented with strain gauges, has been fabricated and assembled around four aluminum 'dummy coils' to determine pre-load homogeneity and mechanical characteristics during cool-down. After presenting the main magnetic and mechanical parameters of LQS01, we report in this paper on the design, assembly, and test of the support structure, with a comparison between strain gauges data and 3D finite element model results.

43 PARTICLE ACCELERATORS↗

Shock tunnel measurements of heat transfer in a model scramjet

The results of heat transfer measurements to the walls of a two dimensional scramjet combustion chamber in a shock tunnel are presented. Thin film heat transfer gauges on a ceramic glass substrate were used. The range of experimental conditions covered produced boundary layers ranging from laminar to transitional, as was independently checked by flow visualization. Empirical flat plate correlations, corrected for local pressure disturbances were used to make a comparison with the experimental results. In the fully laminar regime the heating rates were found to give approximate agreement with the empirical estimates. In the nonlaminar tests the heating rate is found to be well below the fully turbulent levels. It is not known at present if this is a transition effect, or if the pressure corrected flat plate turbulent correlations do not apply to the configuration used.

Morgan, R. G.↗

Introduction to total- and partial-pressure measurements in vacuum systems

An introduction to the fundamentals of total and partial pressure measurement in the vacuum regime (760 x 10 to the -16th power Torr) is presented. The instrument most often used in scientific fields requiring vacuum measurement are discussed with special emphasis on ionization type gauges and quadrupole mass spectrometers. Some attention is also given to potential errors in measurement as well as calibration techniques.

Outlaw, R. A.↗

CFD Code Validation of Wall HeatFluxes for a GO2/GH2 Single Combustor

Computational Fluid Dynamics (CFD) is becoming an important component of injector design in the rocket industry. Injector designers who use CFD in the design process need to understand the accuracy level of the particular code being used for certain aspects of the design. This paper represents a recent effort to demonstrate the accuracy of two CFD codes to calculate the wall heat flux for a single element injector. The FDNS and Loci- CHEM codes currently in use at NASA Marshall Space Flight Center were evaluated. The test case was a single shear coaxial element with gaseous oxygen and hydrogen in a chamber instrumented with coaxial heat flux gauges on the chamber wall down the axis. The data were taken at Penn State University. Measured wall temperatures were used as boundary conditions for the CFD calculations. Calculations were compared to experimental data at chamber pressures of 300,450 600, and 750 psia. The accuracy level of both codes was assessed.

Lin, Jeff↗

Calibration of small gauge thermocouples.

A technique has been developed to dynamically calibrate fine wire thermocouples of 0.025 mm diam and smaller to 1625 K in less than 10 sec. In this method, the varying physical parameters present under typical dynamic heating conditions are simulated, and therefore, wire deterioration can be related to time, temperature, pressure, and atmosphere. A description of the equipment and procedures is given along with the preliminary results that correlate well with thermoelectric theory.

Stewart, W. F.↗

Test Results of HD2, A High Field Nb3Sn Dipole with A 36 MM Bore

The Superconducting Magnet Program at Lawrence Berkeley National Laboratory (LBNL) has developed the 1 m long Nb{sub 3}Sn dipole magnet HD2. With tilted (flared) ends to avoid obstructing a 36 mm clear bore, HD2 represents a step towards the use of block-type coils in high-field accelerator magnets. The coil design has been optimized to minimize geometric harmonics and reduce the conductor peak field in the end region, resulting in an expected short sample dipole field of 15 T. The support structure is composed by an external aluminum shell pre-tensioned with pressurized bladders and interference keys, and by two stainless steel end plates compressing the coil ends through four aluminum axial rods. We report on magnet design, assembly, and test results, including training performance, quench locations, and strain gauge measurements.

43 PARTICLE ACCELERATORS↗

Proof Of Concept of Integrated Load Measurement in 3D Printed Structures

Currently, research on structural health monitoring systems is focused on direct integration of the system into a component or structure. The latter results in a so-called smart structure. One example of a smart structure is a component with integrated strain sensing for continuous load monitoring. Additive manufacturing, or 3D printing, now also enables such integration of functions inside components. As a proof-of-concept, the Fused Deposition Modeling (FDM) technique was used to integrate a strain sensing element inside polymer (ABS) tensile test samples. The strain sensing element consisted of a closed capillary filled with a fluid and connected to an externally mounted pressure sensor. The volumetric deformation of the integrated capillary resulted in pressure changes in the fluid. The obtained pressure measurements during tensile testing are reported in this paper and compared to state-of-the-art extensometer measurements. The sensitivity of the 3D printed pressure-based strain sensor is primarily a function of the compressibility of the capillary fluid. Air- and watertightness are of critical importance for the proper functioning of the 3D printed pressure-based strain sensor. Therefore, the best after-treatment procedure was selected on basis of a comparative analysis. The obtained pressure measurements are linear with respect to the extensometer readings, and the uncertainty on the strain measurement of a capillary filled with water (incompressible fluid) is ±3.1 µstrain, which is approximately three times less sensitive than conventional strain gauges (±1 µstrain), but 32 times more sensitive than the same sensor based on air (compressible fluid) (±101 µstrain).

42 ENGINEERING↗

Apparatus for absolute pressure measurement

An absolute pressure sensor (e.g., the diaphragm of a capacitance manometer) was subjected to a superimposed potential to effectively reduce the mechanical stiffness of the sensor. This substantially increases the sensitivity of the sensor and is particularly useful in vacuum gauges. An oscillating component of the superimposed potential induced vibrations of the sensor. The phase of these vibrations with respect to that of the oscillating component was monitored, and served to initiate an automatic adjustment of the static component of the superimposed potential, so as to bring the sensor into resonance at the frequency of the oscillating component. This establishes a selected sensitivity for the sensor, since a definite relationship exists between resonant frequency and sensitivity.

Hecht, R.↗

Erosive burning research

A status report is given on the results for the completed tests in a series of motor firings being carried out to measure the effects of the parameters that are considered to most strongly influence the scaling to larger rocket motor sizes of the transition to/or threshold conditions for erosive burning rate augmentation. Propellant burning rates at locations along the axis of the test motors are measured with a newly developed plasma capacitance gauge technique. The measured results are compared with erosive-burning predictions from a supporting ballistics analysis. The completed motor firings have successfully demonstrated response to the designed test variables. The trends with varying propellant burning rate, chamber pressure, and mass flow rate are consistent with existing results, but no pronounced effect of surface roughness has been observed. Rather, the influence of propellant oxidizer particle size on erosive burning is through its effect on the base, no-corssflow burning rate.

Strand, L.↗

Dynamics and thermodynamics of a nonlocal Polyakov--Nambu--Jona-Lasinio model with running coupling

A nonlocal covariant extension of the two-flavor Nambu and Jona-Lasinio model is constructed, with built-in constraints from the running coupling of QCD at high-momentum and instanton physics at low-momentum scales. Chiral low-energy theorems and basic current algebra relations involving pion properties are shown to be reproduced. The momentum-dependent dynamical quark mass derived from this approach is in agreement with results from Dyson-Schwinger equations and lattice QCD. At finite temperature, inclusion of the Polyakov loop and its gauge invariant coupling to quarks reproduces the dynamical entanglement of the chiral and deconfinement crossover transitions as in the (local) Polyakov-loop-extended Nambu and Jona-Lasinio model, but now without the requirement of introducing an artificial momentum cutoff. Steps beyond the mean-field approximation are made including mesonic correlations through quark-antiquark ring summations. Various quantities of interest (pressure, energy density, speed of sound, etc.) are calculated and discussed in comparison with lattice QCD thermodynamics at zero chemical potential. The extension to finite quark chemical potential and the phase diagram in the (T,{mu})-plane are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of vacuum pressure with a magneto-optical trap: A pressure-rise method

The lifetime of an atom trap is often limited by the presence of residual background gases in the vacuum chamber. This leads to the lifetime being inversely proportional to the pressure. Here, we use this dependence to estimate the pressure and to obtain pressure rate-of-rise curves, which are commonly used in vacuum science to evaluate the performance of a system. We observe different rates of pressure increase in response to different levels of outgassing in our system. Therefore, we suggest that this is a sensitive method which will find useful applications in cold atom systems, in particular, where the inclusion of a standard vacuum gauge is impractical.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quadrupole ion pump performance characteristics.

A new nonmagnetic ion pump is described that resembles a quadrupole ionization gauge. The dimensions are larger, and hyperbolically shaped electrodes replace the four rods. Pumping speeds (4-100 liters per sec) for different gases at various peak voltages (1000-3000 V) at corresponding frequencies (57-100 MHz) and at different pressures (10 microtorr to 1 nanotorr) are reported.

Schwarz, H.↗

Critical energy barrier for capillary condensation in mesopores: Hysteresis and reversibility

Capillary condensation in the regime of developing hysteresis occurs at a vapor pressure, P{sub cond}, that is less than that of the vapor-like spinodal. This is because the energy barrier for the vapor-liquid transition from a metastable state at P{sub cond} becomes equal to the energy fluctuation of the system; however, a detailed mechanism of the spontaneous transition has not been acquired even through extensive experimental and simulation studies. We therefore construct accurate atomistic silica mesopore models for MCM-41 and perform molecular simulations (gauge cell Monte Carlo and grand canonical Monte Carlo) for argon adsorption on the models at subcritical temperatures. A careful comparison between the simulation and experiment reveals that the energy barrier for the capillary condensation has a critical dimensionless value, W{sub c}{sup *} = 0.175, which corresponds to the thermal fluctuation of the system and depends neither on the mesopore size nor on the temperature. We show that the critical energy barrier W{sub c}{sup *} controls the capillary condensation pressure P{sub cond} and also determines a boundary between the reversible condensation/evaporation regime and the developing hysteresis regime.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inducer Hydrodynamic Load Measurement Devices

Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher-frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

Skelley, Stephen E.↗