Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PMMA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Exploiting Molecular Weight Distribution Shape to Tune Domain Spacing in Block Copolymer Thin Films

We report a method for tuning the domain spacing ( D sp ) of self-assembled block copolymer thin films of poly(styrene-block-methyl methacrylate) (PS- b -PMMA) over a large range of lamellar periods. By modifying the molecular weight distribution (MWD) shape (including both the breadth and skew) of the PS block via temporal control of polymer chain initiation in anionic polymerization, we observe increases of up to 41% in D sp for polymers with the same overall molecular weight ( M n ≈ 125 kg mol –1 ) without significantly changing the overall morphology or chemical composition of the final material. In conjunction with our experimental efforts, we have utilized concepts from population statistics and least-squares analysis to develop a model for predicting D sp based on the first three moments of the MWDs. This statistical model reproduces experimental D sp values with high fidelity (with mean absolute errors of 1.2 nm or 1.8%) and provides novel physical insight into the individual and collective roles played by the MWD moments in determining this property of interest. As a result, this work demonstrates that both MWD breadth and skew have a profound influence over D sp , thereby providing an experimental and conceptual platform for exploiting MWD shape as a simple and modular handle for fine-tuning D sp in block copolymer thin films.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-Assembly of Metal–Organic Framework (MOF) Nanoparticle Monolayers and Free-Standing Multilayers

Here, we report the first self-assembled porous monolayer and free-standing multilayer films composed of metal–organic framework (MOF) nanoparticles. Self-assembled MOF monolayers (SAMMs) were assembled at a liquid–air interface to produce films that are 87 wt % (89 vol %) MOF. Monolayer self-assembly was aided by growing a layer of poly(methyl methacrylate) (PMMA) on the particle surface using a histamine anchor. SAMMs could be stacked to obtain MOF multilayers, including alternating MOF/polymer heterostructures. SAMMs were coated on silicon microparticles, and a MOF film constructed of only five stacked layers could be manipulated as a free-standing, opalescent film. These monolayers are a great advancement for obtaining highly functional porous membranes and coatings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of Surface Interactions in the Synergizing Polymer/Clay Flame Retardant Properties

The absorption of resorcinol di(phenyl phosphate) (RDP) oligomers on clay surfaces has been studied in detail and is being proposed as an alternative method for producing functionalized clays for nanocomposite polymers. The ability of these clays to be exfoliated or intercalated in different homopolymers was investigated using both transmission electron microscopy and small-angle X-ray scattering results, compared with contact angle measurements on Langmuir-Blodgett clay monolayers, where the interfacial energies were used as predictors of the polymer/clay interactions. We found that the contact angle between PS/RDP clay monolayer substrates was {approx}2.5{sup o}, whereas the angle for polystyrene (PS)/Cloisite 20A clays substrates was {approx}32{sup o}, consistent with the large degree of exfoliation observed in PS for the RDP-coated clays. The interfacial activity of these clays was also measured, and we found that the RDP-coated clays segregated to the interfaces of PC/poly(styrene-co-acrylonitrile) blends, while they segregated into the poly(methyl methacrylate) (PMMA) domain of PS/PMMA blends. This morphology was explained in terms of the relative energy advantage in placing the RDP versus the Cloisite clays at the interfaces. Finally, we demonstrated the effects of the relative surface energies of the clays in segregating to the blend air interface when heated to high temperatures. The segregation was shown to affect the composition and mechanical properties of the resulting chars, which in turn could determine their flame retardant response.

36 MATERIALS SCIENCE↗

Hierarchical Self-Assembled Structures from POSS-Containing Block Copolymers Synthesized by Living Anionic Polymerization

Two kinds of polyhedral oligomeric silsesquioxane (POSS)-containing block copolymers (BCPs), namely PS-b-PMAPOSS and PMMA-b-PMAPOSS, were synthesized by living anionic polymerization. A wide range of molecular weights were obtained with a very narrow polydispersity index of less than 1.09. The bulk samples prepared by slow evaporation from a polymer solution in chloroform exhibit well-defined microphase-separated structures with long-range order. Thermal annealing induced hierarchical structures consisting of a smaller length scale ordered crystalline POSS domains within the larger microphase-separated structures. We report detailed structural characterization of these hierarchical structures in bulk and thin films by transmission electron microscopy and grazing incidence wide-angle X-ray scattering (GIWAXS). On the basis of this structural analysis, we propose a model for the formation of an orthorhombic lattice structure through the aggregation of POSS segments which formed a helix-like structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rheological Evidence of Composition Fluctuations in an Unentangled Diblock Copolymer Melt near the Order-Disorder Transition

Rheological and small-angle X-ray scattering (SAXS) measurements were conducted on a symmetric, low molar mass (M n = 17.6 kg/mol), poly(tert-butylstyrene-block-methyl methacrylate) (PtBS-PMMA) diblock copolymer near the order–disorder transition temperature (T ODT = 193 ± 1 °C). Evidence of composition fluctuations is apparent in the low frequency elastic (G') and loss (G") moduli and in the temperature dependence of the peak scattering intensity, I(q*), up to 50 °C above the T ODT . These findings demonstrate that chain entanglements are not responsible for the well-documented fluctuation mode in the terminal viscoelastic regime of block copolymer melts.

Kennemur, Justin G.↗

Trapping light in air with membrane metasurfaces for vibrational strong coupling

Optical metasurfaces can manipulate electromagnetic waves in unprecedented ways at ultra-thin engineered interfaces. Specifically, in the mid-infrared (mid-IR) region, metasurfaces have enabled numerous biochemical sensing, spectroscopy, and vibrational strong coupling (VSC) applications via enhanced light-matter interactions in resonant cavities. However, mid-IR metasurfaces are usually fabricated on solid supporting substrates, which degrade resonance quality factors (Q) and hinder efficient sample access to the near-field electromagnetic hotspots. Besides, typical IR-transparent substrate materials with low refractive indices, such as CaF 2 , NaCl, KBr, and ZnSe, are usually either water-soluble, expensive, or not compatible with low-cost mass manufacturing processes. Here, we present novel free-standing Si-membrane mid-IR metasurfaces with strong light-trapping capabilities in accessible air voids. We employ the Brillouin zone folding technique to excite tunable, high-Q quasi-bound states in the continuum (qBIC) resonances with our highest measured Q-factor of 722. Leveraging the strong field localizations in accessible air cavities, we demonstrate VSC with multiple quantities of PMMA molecules and the qBIC modes at various detuning frequencies. Our new approach of fabricating mid-IR metasurfaces into semiconductor membranes enables scalable manufacturing of mid-IR photonic devices and provides exciting opportunities for quantum-coherent light-matter interactions, biochemical sensing, and polaritonic chemistry. The authors introduce a mid-IR metasurface fabricated by decorating a free-standing Si-membrane with air holes. The enhanced light-matter interactions in such air cavities enable vibrational strong coupling and advanced biochemical sensing.

infrared spectroscopy↗

Silicon Surface Tethered Polymer as Artificial Solid Electrolyte Interface

Here, we have developed a proof of concept electrode design to covalently graft poly(methyl methacrylate) brushes directly to silicon thin film electrodes via surface-initiated atom transfer radical polymerization. This polymer layer acts as a stable artificial solid electrolyte interface that enables surface passivation despite large volume changes during cycling. Thin polymer layers (75 nm) improve average first cycle coulombic efficiency from 62.4% in bare silicon electrodes to 76.3%. Average first cycle reversible capacity was improved from 3157 to 3935 mAh g -1 , and average irreversible capacity was reduced from 2011 to 1020 mAh g -1 . Electrochemical impedance spectroscopy performed on silicon electrodes showed that resistance from solid electrolyte interface formation increased from 79 to 1508 Ω in untreated silicon thin films over 26 cycles, while resistance growth was lower – from 98 to 498 Ω – in silicon films functionalized with PMMA brushes. The lower increase suggests enhanced surface passivation and lower electrolyte degradation. This work provides a pathway to develop artificial solid electrolyte interfaces synthesized under controlled reaction conditions.

36 MATERIALS SCIENCE↗

Quantifying motion blur by imaging shock front propagation with broadband and narrowband X-ray sources

Time-integrated radiography using MeV Bremsstrahlung X-ray sources is the norm for imaging during system-level testing of components and structures under dynamic condition. One source of error in the analysis of the time-integrated radiography data sets stems from motion blur which smears out sharp interfaces to a greater degree with longer exposure times, which become necessary to provide sufficient signal-to-noise with low X-ray penetration of objects of interest. To quantify motion blur, a 1D shock wave through PMMA was investigated experimentally at The Dynamic Compression Sector at The Advanced Photon Source (DCS@APS) with tapered broadband and 25.46 ± 1.06 keV narrowband X-rays. Four cameras with different exposure times were used for each experiment to compare the effect that exposure time has on motion blur. In addition, our methodology to accurately simulate motion blur in terms of transmission and shape is presented and compared to our experimental results and quantified. There is a high level of agreement between the experimental and simulation results across the range of data sets investigated in this study with a percent difference range of 0.29–1.31% for the four shots. The methodology of this work serves as a steppingstone towards a physically validated model that could be used in conjunction with experimental results to deconvolve physical parameters, densities, and interfaces of interest in a way that would not be possible with experimental results alone.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-particle chemical analysis reveals organic-rich detonation soot products

The detonation of high explosives produces a wide variety of particulate matter (PM) with distinct properties, not all of which are traditionally studied for chemical composition, formation processes, and forensic applications. We report particle-resolved measurements of Composition B detonation soot using soot particle aerosol mass spectrometry (SP-AMS), identifying carbonaceous species and metals not previously characterized on a single-particle basis. Results are combined with scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS) to enhance source-dependent signatures. Black carbon, including graphitic carbon and detonation nanodiamonds, contributed 50.5-71.4% of PM 2.5 mass, while 22.5-43.4% was non-refractory organic carbon, a previously overlooked component that exhibited a complex and varying composition. Detonations were performed with and without PMMA confinement and under steady and overdriven conditions. Distinct particles enriched with polycyclic aromatic hydrocarbons (PAHs) were observed in experiments utilizing confinement, with quantities dependent on manufacturing method. SEM-EDS validated SP-AMS findings of metals internally mixed with carbonaceous species and extended the particle size range to 100 µm. This work makes detecting non-refractory organics using single-particle techniques more feasible for detonation forensics and understanding high-energy soot formation. While this analysis uses offline sample collection, SP-AMS could be deployed for in-situ measurements of detonation PM 2.5 transported in the atmosphere.

36 MATERIALS SCIENCE↗

A new strategy to engineer polymer bulk heterojunction solar cells with thick active layers via self-assembly of the tertiary columnar phase

Here, we report that the addition of a non-photoactive tertiary polymer phase in the binary bulk heterojunction (BHJ) polymer solar cell leads to a self-assembled columnar nanostructure, enhancing the charge mobilities and photovoltaic efficiency with surprisingly increased optimal active blend thicknesses over 300 nm, 3–4 times larger than that of the binary counterpart. Using the prototypical poly(3-hexylthiophene) (P3HT):fullerene blend as a model BHJ system, we discover that the inert poly(methyl methacrylate) (PMMA) added in the binary BHJ blend self-assembles into vertical columns, which not only template the phase segregation of electron acceptor fullerenes but also induce the out-of-plane rotation of the edge-on-orientated crystalline P3HT phase. Using complementary interrogation methods including neutron reflectivity, X-ray scattering, atomic force microscopy, transmission electron microscopy, and molecular dynamics simulations, we show that the enhanced charge transport originates from the more randomized molecular stacking of the P3HT phase and the spontaneous segregation of fullerenes at the P3HT/PMMA interface, driven by the high surface tension between the two polymeric components. The results demonstrate a potential method for increasing the thicknesses of high-performance polymer BHJ solar cells with improved photovoltaic efficiency, alleviating the burden of stringently controlling the ultrathin blend thickness during the roll-to-roll-type large-area manufacturing environment.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Block copolymer self-assembly to pattern gold nanodots for site-specific placement of DNA origami and attachment of nanomaterials

Directed placement of DNA origami could play a key role in future integrated nanoelectronic devices. Here we demonstrated the site-selective attachment of DNA origami on gold dots formed using a pattern transfer method through block copolymer self-assembly. First, a random copolymer brush layer is grafted on the Si surface and then poly (styrene-b-methylmethacrylate) block copolymer is spin-coated to give a hexagonal nanoarray after annealing. UV irradiation followed by acetic acid etching is used to remove the PMMA, creating cylindrical holes and then oxygen plasma etching removes the random copolymer layer inside those holes. Next, metal evaporation, followed by lift-off creates a gold dot array. We evaluated different ligand functionalization of Au dots, as well as DNA hybridization to attach DNA origami to the nanodots. DNA-coated Au nanorods are assembled on the DNA origami as a step towards creating nanowires and to facilitate electron microscopy characterization of the attachment of DNA origami on these Au nanodots. The DNA hybridization approach showed better DNA attachment to Au nanodots than localization by electrostatic interaction. Here, this work contributes to the understanding of DNA-templated assembly, nanomaterials, and block copolymer nanolithography. Furthermore, the work shows potential for creating DNA-templated nanodevices and their placement in ordered arrays in future nanoelectronics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Potential High Resolution Dosimeters For MRT

Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow ({approx}25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 {mu}m microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric Quantities for Computed Tomography Examinations of Paediatric Patients on the Thoracic and Abdominal Regions

Computed Tomography (CT) is a high dose X ray imaging procedure and its use has rapidly increased in the last two decades fueled by the development of helical CT. The aim of this study is to present values of the dosimetric quantities for CT paediatric examinations of thoracic and abdominal regions. The protocols studied were those of chest, lung-mediastine, chest-abdomen, pulmonary high resolution and mediastine-abdomen, which are the more common examinations performed at ''Hospital Infantil de Mexico Federico Gomez'' in the thoracic-abdominal region. The measurements were performed on a Siemens SOMATOM Sensation 16 CT Scanner and the equipment used was a CT pencil ionization chamber, connected to an electrometer. This system was calibrated for RQT9 CT beam quality. A PMMA head phantom with diameter of 16 cm and length of 15 cm was also used. The dosimetric quantities measured were the weighted air kerma index (C{sub w}), the volumetric dose index (C{sub vol}) and the CT air kerma-length product. It was found that the pulmonary high resolution examination presented the highest values for the C{sub w}(31.1 mGy) and C{sub vol}(11.1 mGy). The examination with the lowest values of these two quantities was the chest-abdomen protocol with 10.5 mGy for C{sub w} and 5.5 mGy for C{sub vol}. However, this protocol presented the highest value for P{sub KL,CT}(282.2 mGy cm) when considering the average clinical length of the examinations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Scanning Lens Instrument for Evaluating Fresnel Lens Performance: Equipment Development and Initial Results (Presentation)

A system dedicated to the optical transmittance characterization of Fresnel lenses has been developed at NREL, in collaboration with the UPM. The system quantifies the optical efficiency of the lens by generating a performance map. The shape of the focused spot may also be analyzed to understand change in the lens performance. The primary instrument components (lasers and CCD detector) have been characterized to confirm their capability for performing optical transmittance measurements. Measurements performed on SoG and PMMA lenses subject to a variety of indoor conditions (e.g., UV and damp heat) identified differences in the optical efficiency of the evaluated lenses, demonstrating the ability of the Scanning Lens Instrument (SLI) to distinguish between the aged lenses.

14 SOLAR ENERGY↗

Femtosecond lasers for microsurgery of cornea

The review of femtosecond laser installations for medical applications is given and a new femtosecond ophthalmologic system for creation of a flap of corneal tissue during the LASIK operation is described. An all-fibre femtosecond laser emitting {approx}400-fs pulses at 1067 nm is used. The pulse repetition rate can vary from 200 kHz up to 1 MHz. The output energy of the femtosecond system does not exceed 1 {mu}J. A specially developed objective with small spherical and chromatic aberrations is applied to focus laser radiation to an area of an eye cornea. The size of the focusing spot does not exceed 3 {mu}m. To process the required area, scanning by a laser beam is applied with a speed no less than 5 m s{sup -1}. At a stage of preliminary tests of the system, the {Kappa}8 glass, organic PMMA glass and specially prepared agarose gels are used as a phantom of an eye. The femtosecond system is successfully clinically tested on a plenty of eyes of a pig and on several human eyes. The duration of the procedure of creation of a corneal flap does not exceed 20 s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crystal structures of (Mg1;#8722;x,Fex)SiO[subscript 3] postperovskite at high pressures

X-ray diffraction experiments on postperovskite (ppv) with compositions (Mg{sub 0.9}Fe{sub 0.1})SiO{sub 3} and (Mg{sub 0.6}Fe{sub 0.4})SiO{sub 3} at Earth core-mantle boundary pressures reveal different crystal structures. The former adopts the CaIrO{sub 3}-type structure with space group Cmcm, whereas the latter crystallizes in a structure with the Pmcm (Pmma) space group. The latter has a significantly higher density ({rho} = 6.119(1) g/cm{sup 3}) than the former ({rho} = 5.694(8) g/cm{sup 3}) due to both the larger amount of iron and the smaller ionic radius of Fe{sup 2+} as a result of an electronic spin transition observed by X-ray emission spectroscopy (XES). The smaller ionic radius for low-spin compared to high-spin Fe{sup 2+} also leads to an ordered cation distribution in the M1 and M2 crystallographic sites of the higher density ppv structure. Rietveld structure refinement indicates that approximately 70% of the total Fe{sup 2+} in that phase occupies the M2 site. XES results indicate a loss of 70% of the unpaired electronic spins consistent with a low spin M2 site and high spin M1 site. First-principles calculations of the magnetic ordering confirm that Pmcm with a two-site model is energetically more favorable at high pressure, and predict that the ordered structure is anisotropic in its electrical and elastic properties. These results suggest that interpretations of seismic structure in the deep mantle need to treat a broader range of mineral structures than previously considered.

36 MATERIALS SCIENCE↗