Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Investigation of magnetic-pole-enhanced inductively coupled nitrogen-argon plasmas

This article presented the features of the mixed mode and H mode in magnetic pole enhanced, inductively coupled Ar-N{sub 2} plasmas using RF-compensated Langmuir probe measurements. To fully characterize plasma parameters and electron energy probability functions (EEPFs), the gas pressure and argon content were varied. It was observed that with increasing the nitrogen content and gas pressure, the critical RF power to sustain H mode increases; this increase was more prominent for pure nitrogen discharge at higher pressure. The electron number density (n{sub e}) shows increasing trend with increasing RF power, while at higher gas pressures, the electron number density decreases at fixed RF power. Mostly, the EEPFs show a Maxwellian distribution even at low RF power (for higher argon content in the discharge) and at moderate RF power (for higher or pure nitrogen content in the discharge) for pressures of 15-60 mTorr. With increasing the nitrogen content in the mixture, the low energy part of the EEPF is more Druyvesteyn with a distorted high energy tail at low RF power. At fixed RF power, the slope of EEPF changes sharply with increasing pressure. It was observed that in hybrid mode, the EEPF at higher gas pressure (75 mTorr) in a pure nitrogen discharge shows a flat hole near the average electron energy of 3 eV and changes to Maxwellian distribution in H mode. The skin depth versus RF power shows that the skin depth is smaller than the critical dimension of the chamber, regardless of the gas type and the gas pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space Flight Plasma Data Analysis

This slide presentation reviews a method to analyze the plasma data that is reported on board the International Space station (ISS). The Floating Potential Measurement Unit (FPMU), the role of which is to obtain floating potential and ionosphere plasma measurements for validation of the ISS charging model, assess photo voltaic array variability and interpreting IRI predictions, is composed of four probes: Floating Potential Probe (FPP), Wide-sweep Langmuir Probe (WLP), Narrow-sweep Langmuir Probe (NLP) and the Plasma Impedance Probe (PIP). This gives redundant measurements of each parameter. There are also many 'boxes' that the data must pass through before being captured by the ground station, which leads to telemetry noise. Methods of analysis for the various signals from the different sets are reviewed. There is also a brief discussion of LP analysis of Low Earth Orbit plasma simulation source.

Wright, Kenneth H.↗

The radio-frequency fluctuation effect on the floating harmonic method

The radio-frequency (RF) plasma diagnostics with an electrical probe facing a challenge, because the RF fluctuation oscillates the plasma potential and distorts the current-voltage (I-V) curve. As Langmuir probe is widely used in plasma diagnostics, many researchers have been studying the effect of RF fluctuation on probe and compensation methods. On the other hand, there have not been enough studies on the fluctuation effect on the floating harmonic method. Therefore, we investigated the impact of RF fluctuation on the floating harmonic method theoretically and experimentally. When the electrons are in ideal Maxwellian distribution, the floating potential is negatively shifted by the RF fluctuation, but the fluctuation does not distort I-V curve around the floating potential. However, in practical plasmas, the I-V curve and their harmonic components are distorted. This RF fluctuation effect becomes more significant in a low density plasma with a high impedance sheath. The second harmonic current decreases with the RF fluctuation while the first harmonic current is merely affected. Therefore, the electron temperatures measured with the floating harmonic method under low density plasma with uncompensated probe are overestimated than the results obtained with the compensated probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: Application of laser produced plasma K{alpha} x-ray probe in radiation biology

A dedicated radiation biology x-ray generation and exposure system has been developed. 8.0 keV in energy x-ray pulses generated with a femtosecond-laser pulse was used to irradiate sample cells through a custom-made culture dish with a silicon nitride membrane. The x-ray irradiation resulted in DNA double-strand breaks in the nucleus of a culture cell that were similar to those obtained with a conventional x-ray source, thus demonstrating the feasibility of radiobiological studies utilizing a single burst of x-rays focused on single cell specimens.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

A direct Vlasov code to study the non-stationary current collection by a cylindrical Langmuir probe

The time-dependent current collection by a cylindrical Langmuir probe, whose bias is suddenly changed from zero to a positive or negative finite value, is studied with a novel direct Vlasov code. The numerical algorithm is based on finite-difference formulas to approximate spatial and velocity derivatives and the time integration is carried out with an explicit Runge-Kutta method, or in the case of probe radius small compared with the Debye length, by using the unconditionally stable backward Euler scheme. Both electrons and ions are treated kinetically by the code, which implements initial and boundary conditions that are consistent with the presence of the probe. Within the considered parameter range, the plasma sheath around the probe exhibited an overshoot and it later recovered a steady state. Phase space diagrams of the particle trajectories revealed the presence of a trapped population of particles. The dependence of this population as a function of the probe radius is presented as well as a comparison with the stationary theory. The performance of the code and a comparison with previously used particle-in-cell algorithms are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma characterization of the superconducting proton linear accelerator plasma generator using a 2 MHz compensated Langmuir probe

The CERN study for a superconducting proton Linac (SPL) investigates the design of a pulsed 5 GeV Linac operating at 50 Hz. As a first step towards a future SPL H{sup -} volume ion source, a plasma generator capable of operating at Linac4 or nominal SPL settings has been developed and operated at a dedicated test stand. The hydrogen plasma is heated by an inductively coupled RF discharge e{sup -} and ions are confined by a magnetic multipole cusp field similar to the currently commissioned Linac4 H{sup -} ion source. Time-resolved measurements of the plasma potential, temperature, and electron energy distribution function obtained by means of a RF compensated Langmuir probe along the axis of the plasma generator are presented. The influence of the main tuning parameters, such as RF power and frequency and the timing scheme is discussed with the aim to correlate them to optimum H{sup -} ion beam parameters measured on an ion source test stand. The effects of hydrogen injection settings which allow operation at 50 Hz repetition rate are discussed.

43 PARTICLE ACCELERATORS↗

Negative plasma potential in a multidipole chamber with a dielectric coated plasma boundary

Negative plasma potentials with respect to a grounded wall that was coated with a dielectric have been achieved in an electropositive plasma confined by a multidipole device. A Langmuir probe was used to measure the density and temperatures of the bi-Maxwellian distribution electrons and an emissive probe was used to measure the plasma potential profile near the plasma boundary. For many discharge parameters, the potential profile was that of a typical electropositive sheath, but it was shifted negative due to negative charge accumulated on the plasma-surface boundary. A virtual cathode was observed near the boundary when the neutral pressure, primary electron energy, and/or discharge current were low ({approx}2 x 10{sup -4} Torr, {approx}60 eV, and 80 mA, respectively). The behavior of the sheath potential was shown to be consistent with that predicted by particle balance and a qualitative mechanism for wall charging is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Area influences and floating potentials in Langmuir probe measurements.

Analysis of the influence of a relatively small reference electrode on a Langmuir probe measurement of plasma density and temperature. The analysis employs the collisionless theory of Laframboise for spherical and cylindrical probes and in a completely general way includes a broad range of electron densities and temperatures, as well as all possible values of ion mass and multiplicity of ionization. It is shown that a ratio alpha of reference-electrode area to probe area of 10,000 will guarantee no distortion of the measurement as a result of a shifting reference-electrode potential. It is further shown that the constraint on alpha can be relaxed by approximately two orders of magnitude when the charge-normalized ion mass is decreased from 200 to 1 amu and the ratio of reference-electrode radius to Debye length is decreased from 100 to 0. An additional result of the analysis is the dependence of a probe's floating potential on its geometry and radius, as well as on the properties of the plasma. A discussion of the latter result reveals in a striking manner the significant differences between the ion-current responses of spherical and cylindrical probes.

Szuszczewicz, E. P.↗

A Langmuir probe diagnostic for time-of-flight measurements of transient plasmas produced by high-energy laser ablation

We discuss here the development of a Langmuir probe (LP) diagnostic to examine high-density, high-temperature inhomogeneous plasmas such as those that can be created at the University of Rochester's Laboratory for Laser Energetics OMEGA facility. We have configured our diagnostic to examine the velocity of the plasma expanding from the target. We observe velocities of approximately 16-17 cm/{mu}s, with individual LP currents displaying complex structures, perhaps due to the multiple atomic species and ionization states that exist.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New model for the ion collection by cylindrical probes over a wide range of collisionality

Langmuir probes remain one of the most important diagnostic tools for plasma processing applications. Modern probe analysis usually relies on the electron current part of the Langmuir probe characteristic using the Druyvesteyn method. However, for electronegative plasmas or for discharges containing dust the analysis of the ion current attracted by the probe can be desirable to determine the ion density. But, even at low pressures of a few Pa, the ion current is affected by collisions due to the large cross section for charge exchange. Available theories for collisional or collision-enhanced ion currents onto probes are complex and not well validated. Thus, in this contribution, we compare available collisional probe theories for the ion current to results of particle-in-cell (PIC) simulations. To this end, the probe surrounded by a semi-infinite plasma is simulated using a modified version of the open-source code EDIPIC. A dataset of currents for different neutral gas pressures is obtained and compared to the different theories from the literature. Based on these results, we propose a simpler and more intuitive model for the ion current collected by the probe, based on the model of Gatti and Kortshagen (Phys. Rev. E 78, 046402, 2008), developed for the charging of dust particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Composition of Plasma inside Geostationary Orbit Based on Van Allen Probes Observations

The composition of the inner magnetosphere is of great importance for determining the plasma pressure, and thus the currents and magnetic field configuration. In this study, we perform a statistical survey of equatorial plasma pressure distributions and investigate the relative contributions of ions and electron with different energies inside of geostationary orbit under two AE levels based on over sixty months of observations from the HOPE and RBSPICE mass spectrometers on board Van Allen Probes. We find that the total and partial pressures of different species increase significantly at high AE levels with Hydrogen (H + ) pressure being dominant in the plasmasphere. The pressures of the heavy ions and electrons increase outside the plasmapause and develop a strong dawn-dusk asymmetry with ion pressures peaking at dusk and electron pressure peaking at dawn. In addition, ring current H + with energies ranging from 50 keV up to several hundred keV is the dominant component of plasma pressure during both quiet (> 90%) and active times (> 60%), while Oxygen (O + ) with 10 < E < 50 keV and electrons with 0.1 < E < 40 keV become important during active times contributing more than 25% and 20% on the nightside, respectively, while the Helium (He + ) contribution is generally small. The results presented in this study provide a global picture of the equatorial plasma pressure distributions and the associated contributions from different species with different energy ranges, which advance our knowledge of wave generation and provide models with a systematic baseline of plasma composition.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray radiography and scattering diagnosis of dense shock-compressed matter

Highly coupled Boron plasma has been probed by spectrally resolving an x-ray source scattered by the plasma. Electron density was inferred from the inelastic feature in the collective scattering regime. In addition, the mass density inferred from the noncollective x-ray Thomson scattering has been tested with independent characterization using x-ray radiography in the same drive condition. High-intensity laser produced K-alpha radiation was used as a backlighter for these dynamically compressed plasma experiments providing a high temporal resolution of the measurements. Mass density measurements from both methods are in good agreement. The measurements yield a compression of 1.3 in agreement with detailed radiation-hydrodynamic modeling. From the charge state measured in the noncollective regime and the electron density measured in the collective regime mass density can then be constrained to 3.15+-0.7.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time and space resolved interferometry for laser-generated fast electron measurements

A technique developed to measure in time and space the dynamics of the electron populations resulting from the irradiation of thin solids by ultraintense lasers is presented. It is a phase reflectometry technique that uses an optical probe beam reflecting off the target rear surface. The phase of the probe beam is sensitive to both laser-produced fast electrons of low-density streaming into vacuum and warm solid density electrons that are heated by the fast electrons. A time and space resolved interferometer allows to recover the phase of the probe beam sampling the target. The entire diagnostic is computationally modeled by calculating the probe beam phase when propagating through plasma density profiles originating from numerical calculations of plasma expansion. Matching the modeling to the experimental measurements allows retrieving the initial electron density and temperature of both populations locally at the target surface with very high temporal and spatial resolution ({approx}4 ps,6 {mu}m). Limitations and approximations of the diagnostic are discussed and analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing the fields in an ultracold plasma by microwave spectroscopy

By observing the Stark shift of the Rb 42s{sub 1/2}-42p{sub 1/2} microwave transition we have measured the electric fields in an ultracold plasma formed by photoionizing Rb atoms in a magneto-optical trap. Using this approach and a model of the electron charge distribution we have been able to measure both the microscopic fields due to nearest-neighbor ions and the macroscopic fields due to the charge imbalance in the plasma.

74 ATOMIC AND MOLECULAR PHYSICS↗