Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA DIAGNOSTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Energy resolved actinometry for simultaneous measurement of atomic oxygen densities and local mean electron energies in radio-frequency driven plasmas

A diagnostic method for the simultaneous determination of atomic oxygen densities and mean electron energies is demonstrated for an atmospheric pressure radio-frequency plasma jet. The proposed method is based on phase resolved optical emission measurements of the direct and dissociative electron-impact excitation dynamics of three distinct emission lines, namely, Ar 750.4 nm, O 777.4 nm, and O 844.6 nm. The energy dependence of these lines serves as basis for analysis by taking into account two line ratios. In this frame, the method is highly adaptable with regard to pressure and gas composition. Results are benchmarked against independent numerical simulations and two-photon absorption laser-induced fluorescence experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Brewster angle-cavity ringdown spectroscopy for low temperature plasma measurements in multiphases

Here we report on the development of a Brewster angle-cavity ringdown spectroscopy (BA-CRDS) system for low temperature plasma diagnostics. The system can measure gas species in solutions, with a detection limit (minimum detectable absorbance) of 9.1 × 10 -5 , which is equivalent to a detection limit of 0.04 parts per billion for measuring OH radicals in water at 308 nm. With higher reflectivity ringdown mirrors and improved design of a Brewster angle cell, the detection limit can potentially be up to 10 -6 or lower. In this exploratory study, the absorption cross sections of HgBr 2 and H 2 O 2 in the aqueous phase at 256 nm are measured to be (1.8 ± 0.1) × 10 -18 cm 2 and (5.2 ± 0.5) × 10 -20 cm 2 , respectively. Furthermore, temporal profiles of absorbance from distilled water, HgBr 2 , and H 2 O 2 solutions when interacting with a helium atmospheric plasma jet are individually characterized at different plasma powers, gas flow rates, and/or solute concentrations. The observed linear temporal profiles of absorbance from the plasma-interacted water suggest formation of H 2 O 2 from plasma-generated OH radicals, while the nonlinear temporal profiles from the plasma-treated HgBr 2 solutions reveal possible removal of HgBr 2 by OH radicals. Our results demonstrate that the new BA-CRDS system is a powerful tool for quantification of reactive plasma species in multiphases or other complex settings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional simulation of whistler mode excited by the Spacelab 2 electron beam

During the Spacelab 2 mission, while an electron beam was being ejected from the Shuttle, the Plasma Diagnostics Package (PDP) detected a clear funnel-shaped emission that is believed to be caused by whistler-mode emission from the electron beam. In order to understand the mechanism of this emission, simulations with a three-dimensional partially magnetostatic code have been performed. The simulation results show that whistler-mode and lower hybrid waves are excited by the electron beam, which is initially localized in the column in the three-dimensional simulation system, and that they propagate away from the beam. The wave spectra of the electric and magnetic fields diagnosed at some points show several peaks due to the waves excited by the electron beam. The frequency range of these spectra is in qualitative agreement with the PDP data. The intense narrowband electrostatic emission near the electron plasma frequency is observed by the simulations. The simulation results show that the beam instability is responsible for the generation mechanism of these emissions.

Nishikawa, K.-I.↗

X-ray Pump-Probe Measurements using a Laser-Plasma Accelerator (Final Report)

This project funded one graduate student, Mario Balcazar, to perform experiments on high power laser facilities to study the application of X-rays generated by laser wakefield accelerated electrons for advanced radiography, in particular X-ray phase contrast imaging of hydrodynamic shocks/instabilities. The work made use of the DOE’s LaserNetUS facilities. We performed dynamic phase-contrast X-ray imaging of the shock generated by a 200 ps duration laser pulse (E = 1 J, I = 10 15 Wcm –2 ) with a 30 µm diameter liquid target, with unprecedented spatio-temporal resolution. This includes multi-shock generation within the liquid jet and plasma instability formation. Innovative electron-beam radiography was used to probe the laser-plasma interplay finding evidence of bilateral heating of the water followed by strong electric field generation. These measurements help explain some of the discrepancies between simulation and experiment and pave the way to better plasma diagnostic systems in HED and ICF physics experiments. This work was performed in collaboration with researchers from Michigan, LLNL, LBL and Sandia National Laboratories, Queen’s University Belfast and Imperial College.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion Thruster Used to Propel the Deep Space 1 Spacecraft to Comet Encounters

The NASA Solar Electric Propulsion Technology Applications Readiness (NSTAR) Project provided a xenon ion propulsion system to the Deep Space 1 (DS1) spacecraft to validate the propulsion system as well as perform primary propulsion for asteroid and comet encounters. The On-Board Propulsion Branch of the NASA Glenn Research Center at Lewis Field developed engineering model versions of the 30-cm-diameter ion thruster and the 2.5-kW power processor unit (PPU). Glenn then transferred the thruster and PPU technologies to Hughes Electron Dynamics and managed the contract, which supplied two flight sets of thrusters and PPU s to the Deep Space 1 spacecraft and to a ground-based life verification test at the Jet Propulsion Laboratory (JPL). In addition to managing the DS1 spacecraft development, JPL was responsible for the NSTAR Project management, thruster life tests, the feed system, diagnostics, and propulsion subsystem integration. The ion propulsion development team included NASA Glenn, JPL, Hughes Electronics, Moog Inc., and Spectrum Astro Inc. The overall NSTAR subsystem dry mass, including thruster, PPU, controller, cables, and the xenon storage and feed system, is 48 kg. The mass of the xenon stored onboard DS1 was about 81 kg, and the spacecraft wet mass was approximately 500 kg.The DS1 spacecraft was launched on October 24, 1998, and on July 29, 1999, it flew within 16 miles of the small asteroid Braille (formerly 1992KD) at a relative speed of 35,000 mph. As of November 1999, the ion propulsion system had performed flawlessly for nearly 149 days of thrusting. NASA has approved an extension to the mission, which will allow DS1 to continue thrusting to encounters with two comets in 2001. The DS1 optical and plasma diagnostic instruments will be used to investigate the comet and space environments. The spacecraft is scheduled to fly past the dormant comet Wilson- Harrington in January 2001 and the very active comet Borrelly in September 2001, at which time approximately 500 days of ion engine thrusting will have been completed.

Sovey, James S.↗

Change in Ion Distribution Function While Crossing the Space Shuttle Wake

During the space shuttle/Spacelab 2 mission (STS-5]F) the Plasma Diagnostic Package (PDP) was placed in free flight in the vicinity of the Orbiter and provided the first opportunity to measure the midwake and far-wake regions of an orbiting spacecraft. During this period the PDP crossed the wake 4 times at downstream distances ranging from 40 m to 240 m. During each crossing a definite change in the ion-retarding potential curves was measured when the PDP was in the shuttle wake compared to the ambient ionosphere. These measurements were obtained by both the differential ion flux probe and the retarding potential analyzer instruments on the PDP. The temperature of the ions, derived from fitting the data to a Maxwellian distribution, are consistent with an enhancement during each wake crossing of as much as a factor of 2.5 (from about 0.08 eV to 0.2 eV). Such studies of plasma wakes were never before performed.

Sorensen, J. E.↗

Performance of Laser Megajoule’s x-ray streak camera

A prototype of a picosecond x-ray streak camera has been developed and tested by Commissariat à l’Énergie Atomique et aux Énergies Alternatives to provide plasma-diagnostic support for the Laser Megajoule. We report on the measured performance of this streak camera, which almost fulfills the requirements: 50-μm spatial resolution over a 15-mm field in the photocathode plane, 17-ps temporal resolution in a 2-ns timebase, a detection threshold lower than 625 nJ/cm{sup 2} in the 0.05–15 keV spectral range, and a dynamic range greater than 100.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new diagnostic of the plasma density profile near the edge transport barrier from measurements of the radial profile of the H{sub {alpha}} line intensity

An edge transport barrier is now one of the most important subjects of controlled fusion research. The edge transport barrier is located in the plasma region where hydrogen atoms readily penetrate, so the intensity of the H{sub {alpha}} (D{sub {alpha}}) line is high enough. A new diagnostic method uses the well-known property of hydrogen atoms that the ratio of the ionization rate S{sub i} to the excitation rate S{sub v} for the H{sub {alpha}} line is nearly constant over a wide range of plasma temperatures and densities. An expression has been derived that relates the radial profiles of the plasma density and H{sub {alpha}} intensity. The use of charge coupled device detectors makes it possible to measure the radial profile of H{sub {alpha}} line intensity with a resolution {approx}0.1 cm; a high intensity of the H{sub {alpha}} line ensures a high time resolution {approx}1 ms. A high resolution is thus achieved for the density profile calculated from the H{sub {alpha}} intensity profile. The method was tested when studying the plasma density profile in the region of edge transport barrier in the L-2M stellarator. It has been shown that the density gradient varies during the barrier formation and that a fine structure of the density profile correlates with a character of the plasma transport near resonance magnetic flux surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of the microcalorimeter spectrometer on-board the Hitomi (Astro-H) observatory (invited)

The Hitomi Soft X-ray Spectrometer (SXS) was a pioneering non-dispersive imaging x-ray spectrometer with 5 eV FWHM energy resolution, consisting of an array of 36 silicon-thermistor microcalorimeters at the focus of a high-throughput soft x-ray telescope. Here, the instrument enabled astrophysical plasma diagnostics in the 0.3–12 keV band. We introduce the SXS calibration strategy and corresponding ground calibration measurements that took place from 2012–2015, including both the characterization of the microcalorimeter array and measurements of the x-ray transmission of optical blocking filters.

47 OTHER INSTRUMENTATION↗

Development of an accelerator-based diagnostic for plasma-facing surfaces in magnetic confinement devices

The focus of this work was the development of the Accelerator-based In-situ Material Surveillance (AIMS) diagnostic. The understanding of plasma-material interaction processes in fusion devices has been greatly hampered by the lack of ability to measure the surface ~micron layers of solid surfaces that are in contact with and greatly modified by the boundary fusion plasma. AIMS was the first diagnostic developed and deployed that allowed non-destructive surface measurements with adequate spatial and time resolution. The deployment was primarily carried out on the Alcator C-Mod tokamak. AIMS diagnostic goal is to remotely generate isotopic concentration maps on a plasma shot-to-shot timescale that cover a large fraction of the plasma-facing surface inside of a magnetic fusion device without the need for vacuum breaks or physical access to the material surfaces. The diagnostic used a compact (~ 1 m), high-current (~ 1 milliamp) radio-frequency quadrupole accelerator to inject 0.9 MeV deuterons into the Alcator C-Mod tokamak. The tokamak magnetic fields were controlled – in between plasma shots – to steer the deuterons to material surfaces where the deuterons cause high-Q nuclear reactions with low-Z isotopes up to 5 microns into the material. The induced neutrons and gamma rays are measured with scintillation detectors; energy spectra analysis provides quantitative reconstruction of surface compositions. Experimental validation showed that low-Z isotopes such as deuterium and boron can be quantified on the material surfaces, and that magnetic steering provides access to different measurement locations. AIMS measurements of D retention on inner wall PFCs were acquired during diverted and limited plasma operations and during wall conditioning experiments om Alcator C-Mod. Intershot measurements demonstrate the local erosion and co-deposition of boron films on PFC surfaces with a constant D-B ratio. This is consistent with previous results suggesting that D co-=deposition with boron is insufficient to account for the net retention observed in Alcator C-Mod. Changes in deuterium concentration during boronization, electron cyclotron and glow cleanings were also measured. These initial results were limited to studying low-Z surface properties, because the Coulomb barrier precludes nuclear reactions between high-Z elements and the ~1 MeV AIMS deuteron beam. In order to measure the high-Z erosion of interest in Alcator C-Mod and future fusion devices, a new technique using deuteron-induced gamma emission and a low-Z depth marker was developed using implanted depth markers as a method of measuring bulk erosion and redeposition. This method is dubbed DEA: Depth marker Erosion with AIMS. DEA simulations and experiments were used to validate this technique, both in the laboratory and via experiments in the EAST tokamak. Based on these results, the DEA technique, using ion beam implanted depth markers as a reference to the surface in order to monitor surfaces for erosion and redeposition, is a viable option as a diagnostic, both in and ex situ. These markers show stability to temperature, the tokamak environment, and multiple probing beams. The ex-situ (eDEA) method, which uses resonances in the cross sections of gamma producing reactions to track the surface, was used to successfully measure erosion in samples that were exposed in the EAST tokamak. The in-situ (iDEA) method, which uses the gamma yield ratio to monitor changes to the surface, was used to differentiate between markers implanted to different depths. Both techniques were successfully simulated, and both presented unique challenges experimentally and in data analysis. In particular, the eDEA probing beam was found to have energy variations leading to initial experimental uncertainty, and the iDEA gamma spectra had conflicting gamma peaks which make data analysis difficult. However, the end result is a promising framework for a diagnostic technique that supplements the abilities of AIMS and expands the possibilities of surface diagnostics in fusion devices. While the results of this work are overwhelmingly encouraging for further development of AIMS in general, and the DEA technique specifically, several areas require significant development before this diagnostic is as robust and widely applicable as a surface diagnostic ought to be. Recommended future work includes the development of a cross section/yield measurement database, erosion tests with secondary verification of results using a fiducial mark from a focused ion beam, and acquiring a new accelerator with a more reliable high energy proton and deuterium beam The project resulted in 14 publications, including the PhD theses of three MIT graduate students, cited in the included bibliography.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-energy x-ray detector calibration for T e and impurity density (n Z ) measurements of MCF plasmas

Here, soft x-ray detection with the new "multi-energy" PILATUS3 detector systems holds promise as a magnetically confined fusion (MCF) plasma diagnostic for ITER and beyond. The measured x-ray brightness can be used to determine impurity concentrations, electron temperatures, n 2 e Z eff products, and to probe the electron energy distribution. However, in order to be effective, these detectors which are really large arrays of detectors with photon energy gating capabilities must be precisely calibrated for each pixel. The energy-dependence of the detector response of the multi-energy PILATUS3 system with 100 K pixels has been measured at Dectris Laboratory. X-rays emitted from a tube under high voltage bombard various elements such that they emit x-ray lines from Zr-Lα to Ag-Kα between 1.8 and 22.16 keV. Each pixel on the PILATUS3 can be set to a minimum energy threshold in the range from 1.6 to 25 keV. This feature allows a single detector to be sensitive to a variety of x-ray energies, so that it is possible to sample the energy distribution of the x-ray continuum and line-emission. PILATUS3 can be configured for 1D or 2D imaging of MCF plasmas with typical spatial energy and temporal resolution of 1 cm, 0.6 keV, and 5 ms, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Design Challenges for In-Flight Exposure to an Electric Propulsion Plasma Plume Environment

The use of electric propulsion to carry out NASA in-space propulsion demands has been increasing. A big part of fulfilling this demand is the Power and Propulsion Element (PPE) for NASA's Lunar Gateway. When built, the PPE will have the largest electric propulsion system to ever fly on a spacecraft, which brings new and difficult challenges. The environment created by the electric propulsion system during on-orbit operation of the thrusters has been shown to be different than those measured during operation in terrestrial vacuum facilities. Understanding the on-orbit environment created by the thrusters and its impacts on the spacecraft is the goal of the Plasma Diagnostic Package (PDP). The PDP is a sensor package, which is being developed by NASA GRC (Glenn Research Center), to fly on the PPE. The PDP will measure different aspects of the thruster plume in order to develop higher fidelity modeling of EP (Electric Power) systems. In order to capture quality measurements of the plume the PDP will need to install sensors in close proximity of it. This poses several unique thermal design challenges. Some of these challenges include: the long duration exposure to plume induced heating, the effects of plume induced erosion and sputter deposition on thermal control surfaces, and the extreme environments of a cis-lunar orbit. This paper looks to define the thermal challenges, explain modeling techniques, and offer design solutions for unique challenges of the PDP mission.

Thermal↗

Diagnosing an IFE Power Plant

This white paper for the Basic Research Needs for Plasma Diagnostics workshop lists a selected set of measurements required for normal and off-normal operation of an Inertial Fusion Energy power plant. An Inertial Fusion Energy (IFE) power plant will require instruments that record how well it is performing and, more importantly, sufficient instruments to diagnose failures during routine operation. It is assumed in this white paper that operating specifications and tolerances have been established before the plant begins operation so that only a minimal set of instruments is required. A pilot plant (a DEMO) would require more instrumentation in order to set those requirements and tolerances. This white paper assumes a laser-based IFE plant that operates at up to 20 Hz. Two scenarios are considered below. One is for routine, nominal operation and the other is when an implosion fails to produce energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical Simulations of a 20-kW Class Hall Thruster Using the Magnetic-Field-Aligned-Mesh Code Hall2De

This paper reports on numerical simulations of the NASA-300M, a 20-kW class Hall thruster developed at the NASA Glenn Research Center (GRC). The numerical simulations have been performed with a 2-D axisymmetric, magnetic field-aligned-mesh (MFAM) plasma solver developed at the Jet Propulsion Laboratory (JPL). The main objective of the collaborative effort is to combine physics-based simulation, plasma diagnostics and recent findings on erosion physics to design and demonstrate a high-power, high-performance Hall thruster that exceeds the life of state-of-the-art Hall thrusters by more than one order of magnitude. The thruster simulations have been carried out at a discharge voltage of 500 V and discharge current of 40 A. The results indicate that although the impact energy of ions may attain values that are comparable to the discharge voltage along the downstream portions of the channel, a withdrawn ionization region and significant ion focusing combine to sustain erosion rates below 1 mm/kh. A more extensive evaluation of the baseline NASA-300M configuration and re-design of this thruster with magnetically shielded walls constitute the main focus of our work in the coming months.

plasma simulations↗

Rhodium coated mirrors deposited by magnetron sputtering for fusion applications

Metallic mirrors will be essential components of all optical spectroscopy and imaging systems for ITER plasma diagnostics. Any change in the mirror performance, in particular, its reflectivity, due to erosion of the surface by charge exchange neutrals or deposition of impurities will influence the quality and reliability of the detected signals. Due to its high reflectivity in the visible wavelength range and its low sputtering yield, rhodium appears as an attractive material for first mirrors in ITER. However, the very high price of the raw material calls for using it in the form of a film deposited onto metallic substrates. The development of a reliable technique for the preparation of high reflectivity rhodium films is therefore of the highest importance. Rhodium layers with thicknesses of up to 2 {mu}m were produced on different substrates of interest (Mo, stainless steel, Cu) by magnetron sputtering. Produced films exhibit a low roughness and crystallite size of about 10 nm with a dense columnar structure. No impurities were detected on the surface after deposition. Scratch tests demonstrate that adhesion properties increase with substrate hardness. Detailed optical characterizations of Rh-coated mirrors as well as results of erosion tests performed both under laboratory conditions and in the TEXTOR tokamak are presented in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental capabilities of the LMJ-PETAL facility

In this study, recent progress in the experimental capabilities of the LMJ-PETAL laser facility is reviewed. Updates on the indirect-drive D 2 implosion experiments and equation-of-state experiments using the LMJ laser are presented, including the commissioning of new plasma diagnostics. Several recent campaigns using the PETAL laser alone are also presented, namely the development of a platform using high-resolution and high-energy X-ray sources for radiography experiments, laser wakefield acceleration studies in the self-modulated regime, and neutron generation using a Target Normal Sheath Accelerated proton beam in a pitcher-catcher configuration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray diagnostics of imploding plasmas from planar wire arrays composed of Cu and few tracer Al wires on the 1MA pulsed power generator at UNR

Tracer aluminum alloyed wires (Al5056) are used to provide additional information for x-ray diagnostics of implosions of Cu planar wire arrays (PWAs). Specifically, the analysis of combined PWA experiments using the extensive set of x-ray diagnostics is presented. In these experiments, which were conducted at the 1MA pulsed power generator at University of Nevada, Reno, the Z-pinch load consisted of several (eight) Cu alloyed (main material) and one to two Al alloyed (tracer) wires mounted in a single plane row or double parallel plane rows, single planar wire array (SPWA) or double planar wire array (DPWA), respectively. The analysis of x-ray spatially resolved spectra from the main material indicates the increase in the electron temperature T{sub e} near the cathode. In general, the axial gradients in T{sub e} are more pronounced for SPWA than for DPWA due to the more 'columnlike' plasma formation for SPWA compared to 'hot-spot-like' plasma formation for DPWA. In addition, x-ray spectra from tracer wires are studied, and estimated plasma parameters are compared with those from the main material. It is observed that the x-ray K-shell Al spectra manifest more opacity features for the case of SPWA with about 18% of Al mass (to the total load mass) compared to the case of DPWA with about 11% of Al mass. The analysis of time-gated spectra shows that the relative intensity of the most intense K-shell Al line, small before the x-ray burst, increases with time and peaks close to the maximum of the sub-keV signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculations for energies, transition rates, and lifetimes in Al-like Kr XXIV

Using the second-order many-body perturbation theory (MBPT) method, a complete and accurate data set of excitation energies, lifetimes, wavelengths, and electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2), and magnetic quadrupole (M2) line strengths, transition rates, and oscillator strengths for the lowest 880 levels arising from the 3l{sup 3} (0≤l≤2), 3l{sup 2}4l{sup ′} (0≤l≤2, 0≤l{sup ′}≤3), 3s{sup 2}5l (0≤l≤4), 3p{sup 2}5l (0≤l≤1), and 3s3p5l (0≤l≤4) configurations in Al-like Kr XXIV is provided. Comparisons are made with available experimental and theoretical results. Our calculated energies are expected to be accurate enough to facilitate identifications of observed lines involving the n=4,5 levels. The complete data set is also useful for modeling and diagnosing fusion plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗