Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE SHIFT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Topography, complex refractive index, and conductivity of graphene layers measured by correlation of optical interference contrast, atomic force, and back scattered electron microscopy

The optical phase shift by reflection on graphene is measured by interference contrast microscopy. The height profile across graphene layers on 300 nm thick SiO{sub 2} on silicon is derived from the phase profile. The complex refractive index and conductivity of graphene layers on silicon with 2 nm thin SiO{sub 2} are evaluated from a phase profile, while the height profile of the layers is measured by atomic force microscopy. It is observed that the conductivity measured on thin SiO{sub 2} is significantly greater than on thick SiO{sub 2}. Back scattered electron contrast of graphene layers is correlated to the height of graphene layers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Picometer sensitivity metrology for EUV absorber phase

With growing interest in EUV attenuated phase-shift masks due to their superior image quality for applications such as dense contact and pillar arrays, it is becoming critical to model, measure, and monitor the intensity and relative phase of multilayer and absorber reflections. We present a solution based on physical modeling of reflectometry data, which can achieve single picometer phase precision and sensitivity to changes in average film thickness below one atomic monolayer. We measure absorber and multilayer reflectivity to determine thin-film parameters with a multidimensional optimization and then acquire a new measurement of either multilayer or absorber to determine perturbations in surface contamination thickness. While it is difficult to assess the accuracy of the first step, the simplicity of the second step allows us to characterize our sensitivity to changes in contamination thickness. Thus, we apply this analysis using an initial set of measurements and repeated measurements after a period of storage. For the multilayer, the total contamination growth was 1068 pm, which occurred almost exclusively during storage (1085 pm) and decreased very slightly during repeated measurements (-17 pm). For the absorber, the behavior was quite different, with a total growth of 126 pm, which occurred much less during storage (28 pm) and primarily during repeated measurements (98 pm). Ultimately, the change in relative phase (absorber minus multilayer) was -0.86 deg for the multilayer and -1.12 deg for the absorber. We estimate the precision of the surface contamination measurement to be 3σ < 6 pm for measuring thickness and 3σ < 0.2 deg for measuring phase.

36 MATERIALS SCIENCE↗

Shear horizontal surface acoustic wave microsensor for Class A viral and bacterial detection.

The rapid autonomous detection of pathogenic microorganisms and bioagents by field deployable platforms is critical to human health and safety. To achieve a high level of sensitivity for fluidic detection applications, we have developed a 330 MHz Love wave acoustic biosensor on 36{sup o} YX Lithium Tantalate (LTO). Each die has four delay-line detection channels, permitting simultaneous measurement of multiple analytes or for parallel detection of single analyte containing samples. Crucial to our biosensor was the development of a transducer that excites the shear horizontal (SH) mode, through optimization of the transducer, minimizing propagation losses and reducing undesirable modes. Detection was achieved by comparing the reference phase of an input signal to the phase shift from the biosensor using an integrated electronic multi-readout system connected to a laptop computer or PDA. The Love wave acoustic arrays were centered at 330 MHz, shifting to 325-328 MHz after application of the silicon dioxide waveguides. The insertion loss was -6 dB with an out-of-band rejection of 35 dB. The amplitude and phase ripple were 2.5 dB p-p and 2-3{sup o} p-p, respectively. Time-domain gating confirmed propagation of the SH mode while showing suppression of the triple transit. Antigen capture and mass detection experiments demonstrate a sensitivity of 7.19 {+-} 0.74{sup o} mm{sup 2}/ng with a detection limit of 6.7 {+-} 0.40 pg/mm{sup 2} for each channel.

60 APPLIED LIFE SCIENCES↗

GLOBAL SAUSAGE OSCILLATION OF SOLAR FLARE LOOPS DETECTED BY THE INTERFACE REGION IMAGING SPECTROGRAPH

An observation from the Interface Region Imaging Spectrograph reveals coherent oscillations in the loops of an M1.6 flare on 2015 March 12. Both the intensity and Doppler shift of Fe xxi 1354.08 Å show clear oscillations with a period of ∼25 s. Remarkably similar oscillations were also detected in the soft X-ray flux recorded by the Geostationary Operational Environmental Satellites ( GOES ). With an estimated phase speed of ∼2420 km s{sup −1} and a derived electron density of at least 5.4 × 10{sup 10} cm{sup −3}, the observed short-period oscillation is most likely the global fast sausage mode of a hot flare loop. We find a phase shift of ∼ π /2 (1/4 period) between the Doppler shift oscillation and the intensity/ GOES oscillations, which is consistent with a recent forward modeling study of the sausage mode. The observed oscillation requires a density contrast between the flare loop and coronal background of a factor ≥42. The estimated phase speed of the global mode provides a lower limit of the Alfvén speed outside the flare loop. We also find an increase of the oscillation period, which might be caused by the separation of the loop footpoints with time.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of conformational molecular dynamics on matter wave interferometry

We investigate the influence of thermally activated internal molecular dynamics on the phase shifts of matter waves inside a molecule interferometer. While de Broglie physics generally describes only the center-of-mass motion of a quantum object, our experiment demonstrates that the translational quantum phase is sensitive to dynamic conformational state changes inside the diffracted molecules. The structural flexibility of tailor-made organic particles is sufficient to admit a mixture of strongly fluctuating dipole moments. These modify the electric susceptibility and through this the quantum interference pattern in the presence of an external electric field. Detailed molecular dynamics simulations combined with density-functional theory allow us to quantify the time-dependent structural reconfigurations and to predict the ensemble-averaged square of the dipole moment which is found to be in good agreement with the interferometric result. The experiment thus opens a different perspective on matter wave interferometry, as we demonstrate here that it is possible to collect structural information about molecules even if they are delocalized over more than 100 times their own diameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kinetic contrast in atomic force microscopy

The mechanism of the formation of phase contrast in atomic force microscopy (AFM) is studied for various conditions of an oscillating tip interacting with the surface. A phase shift is detected in oscillations of the resonating AFM tip during its interaction with the substrate surface when the AFM tip moves over the surface. We substantiate kinetic mechanism of the formation of phase contrast in AFM, which is initiated when the velocity of the AFM tip moving over the substrate surface increases as a result of increasing friction force. A dependence of the kinetic contrast in AFM on the effective roughness of the surface is discovered. Images of the distribution of copper impurity over the silicon surface under atmospheric conditions are obtained using the method of kinetic phase contrast in AFM.

36 MATERIALS SCIENCE↗

High-accuracy waveforms for binary black hole inspiral, merger, and ringdown

The first spectral numerical simulations of 16 orbits, merger, and ringdown of an equal-mass nonspinning binary black hole system are presented. Gravitational waveforms from these simulations have accumulated numerical phase errors through ringdown of < or approx. 0.1 radian when measured from the beginning of the simulation, and < or approx. 0.02 radian when waveforms are time and phase shifted to agree at the peak amplitude. The waveform seen by an observer at infinity is determined from waveforms computed at finite radii by an extrapolation process accurate to < or approx. 0.01 radian in phase. The phase difference between this waveform at infinity and the waveform measured at a finite radius of r=100M is about half a radian. The ratio of final mass to initial mass is M{sub f}/M=0.951 62{+-}0.000 02, and the final black hole spin is S{sub f}/M{sub f}{sup 2}=0.686 46{+-}0.000 04.

39↗

Kinematics of and emission from helically orbiting blobs in a relativistic magnetized jet

We present a general relativistic (GR) model of jet variability in active galactic nuclei due to orbiting blobs in helical motion along a funnel or cone-shaped magnetic surface anchored to the accretion disk near the black hole. Considering a radiation pressure driven flow in the inner region, we find that it stabilizes the flow, yielding Lorentz factors ranging between 1.1 and 7 at small radii for reasonable initial conditions. Assuming these as inputs, simulated light curves (LCs) for the funnel model include Doppler and gravitational shifts, aberration, light bending, and time delay. These LCs are studied for quasi-periodic oscillations (QPOs) and the power spectral density (PSD) shape, and yield an increased amplitude (∼12%), a beamed portion and a systematic phase shift with respect to that from a previous special relativistic model. The results strongly justify implementing a realistic magnetic surface geometry in Schwarzschild geometry to describe effects on emission from orbital features in the jet close to the horizon radius. A power-law-shaped PSD with a typical slope of −2 and QPOs with timescales in the range of (1.37–130.7) days consistent with optical variability in blazars, emerges from the simulations for black hole masses M{sub ∙}=(0.5−5)×10{sup 8} M{sub ⊙} and initial Lorentz factors γ{sub jet,i}=2−10. The models presented here can be applied to explain radio, optical, and X-ray variability from a range of jetted sources including active galactic nuclei, X-ray binaries, and neutron stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of far-infrared three-wave polarimeter-interferometer system for the J-TEXT tokamak

A multichannel three-wave far-infrared polarimeter-interferometer will be constructed on the J-TEXT tokamak (R=1.05 m, a=0.27 m, B{sub T}{<=}3 T, and I{sub P}{<=}350 kA) for current density profile and electron density profile measurements. The system will adopt the three-wave polarimeter configuration which was first introduced on RTP. Three 432.5 {mu}m HCOOH lasers pumped by three CO{sub 2} lasers separately will be adopted, which could generate high output power, nearly 50 mW at each cavity. Two of them will be counter-rotating circularly polarized to probe the Faraday angle, while the third laser will be used as a local oscillator to get the phase shift caused by electron density. Excellent port access (600x76 mm{sup 2}) and high laser power would promise a profile measurement across the whole plasma section with good signal quality. A high-speed digital phase comparator with a few ({approx}2) {mu}s temporal resolution will be developed, so that fast changes of current or density profile could be measured. Six channels will be installed in the first stage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Invited Review Article: Methods for imaging weak-phase objects in electron microscopy

Contrast has traditionally been produced in electron-microscopy of weak phase objects by simply defocusing the objective lens. There now is renewed interest, however, in using devices that apply a uniform quarter-wave phase shift to the scattered electrons relative to the unscattered beam, or that generate in-focus image contrast in some other way. Renewed activity in making an electron-optical equivalent of the familiar “phase-contrast” light microscope is based in part on the improved possibilities that are now available for device microfabrication. There is also a better understanding that it is important to take full advantage of contrast that can be had at low spatial frequency when imaging large, macromolecular objects. In addition, a number of conceptually new phase-plate designs have been proposed, thus increasing the number of options that are available for development. The advantages, disadvantages, and current status of each of these options is now compared and contrasted. Experimental results that are, indeed, superior to what can be accomplished with defocus-based phase contrast have been obtained recently with two different designs of phase-contrast aperture. Nevertheless, extensive work also has shown that fabrication of such devices is inconsistent, and that their working lifetime is short. The main limitation, in fact, appears to be electrostatic charging of any device that is placed into the electron diffraction pattern. The challenge in fabricating phase plates that are practical to use for routine work in electron microscopy thus may be more in the area of materials science than in the area of electron optics.

36 MATERIALS SCIENCE↗

Image segmentation of nanoscale Zernike phase contrast X-ray computed tomography images

Zernike phase contrast is a useful technique for nanoscale X-ray computed tomography (CT) imaging of materials with a low X-ray absorption coefficient. It enhances the image contrast by phase shifting X-ray waves to create changes in amplitude. However, it creates artifacts that hinder the use of traditional image segmentation techniques. We propose an image restoration method that models the X-ray phase contrast optics and the three-dimensional image reconstruction method. We generate artifact-free images through an optimization problem that inverts this model. Though similar approaches have been used for Zernike phase contrast in visible light microscopy, this optimization employs an effective edge detection method tailored to handle Zernike phase contrast artifacts. We characterize this optics-based restoration method by removing the artifacts in and thresholding multiple Zernike phase contrast X-ray CT images to produce segmented results that are consistent with the physical specimens. We quantitatively evaluate and compare our method to other segmentation techniques to demonstrate its high accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-dose phase contrast tomography with conventional x-ray sources

Purpose: The edge illumination (EI) x-ray phase contrast imaging (XPCi) method has been recently further developed to perform tomographic and, thus, volumetric imaging. In this paper, the first tomographic EI XPCi images acquired with a conventional x-ray source at dose levels below that used for preclinical small animal imaging are presented. Methods: Two test objects, a biological sample and a custom-built phantom, were imaged with a laboratory-based EI XPCi setup in tomography mode. Tomographic maps that show the phase shift and attenuating properties of the object were reconstructed, and analyzed in terms of signal-to-noise ratio and quantitative accuracy. Dose measurements using thermoluminescence devices were performed. Results: The obtained images demonstrate that phase based imaging methods can provide superior results compared to attenuation based modalities for weakly attenuating samples also in 3D. Moreover, and, most importantly, they demonstrate the feasibility of low-dose imaging. In addition, the experimental results can be considered quantitative within the constraints imposed by polychromaticity. Conclusions: The results, together with the method's dose efficiency and compatibility with conventional x-ray sources, indicate that tomographic EI XPCi can become an important tool for the routine imaging of biomedical samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-integral method for the radial Dirac equation

A phase-integral (WKB) solution of the radial Dirac equation is calculated up to the third order of approximation, retaining perfect symmetry between the two components of the wave function and introducing no singularities except at the zeroth-order transition points. The potential is allowed to be of scalar, vector, or tensor type, or any combination of these. The connection problem is investigated in detail. Explicit formulas are given for single-turning-point phase shifts and single-well energy levels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermodynamics of Bose-Einstein-condensed clouds using phase-contrast imaging

Phase contrast imaging is used to observe Bose-Einstein condensates at finite temperature in situ. The imaging technique is used to accurately derive the absolute phase shift of a probe laser beam due to both the condensate and the thermal cloud. The accuracy of the method is enhanced by using the periodicity of the intensity signal as a function of the accumulated phase. The measured density profiles can be described using a two-relevant-parameter fit, in which only the chemical potential and the temperature are to be determined. This allows us to directly compare the measured density profiles to different mean-field models in which the interaction between the condensed and the thermal atoms is taken into account to various degrees.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Aharonov-Bohm interactions of a vector unparticle

Recently Georgi argued that a hypothetical conformally invariant hidden sector weakly interacting with ordinary particles will have unusual manifestations at low energies in terms of effective degrees of freedom called unparticles. In this paper we consider Aharonov-Bohm type of interactions due to the vector unparticle coupled to elementary fermions. We have found that the quantum mechanical phase shift is path dependent.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton scattering by a hydrogen atom in an effectively two-body model

It is assumed that the total potential of proton interaction with a hydrogen atom is the sum of the short-range nuclear soft-core Reid potential and the long-range Thomas-Fermi potential. A quantum mechanical analysis of low-energy features of the phase shift and cross section for elastic proton scattering on a hydrogen atom is given for the case of zero total angular momentum. The calculations performed in the present study within a nonlinear version of the variable-phase approach ultimately revealed that, because of a long-range character of the asymptotic behavior of the Thomas-Fermi potential, the respective cross section at low energies oscillates but has a finite number of zeros.

74 ATOMIC AND MOLECULAR PHYSICS↗

Coherent production of the K{sup +}π{sup 0} system by K{sup +} mesons on copper nuclei in the OKA detector

In a sample of ∼5 × 10{sup 9} positive kaon collisions with copper nuclei, the events of coherent production of K{sup +}π{sup 0} pairs are selected, the contributions of the Coulomb and strong production mechanisms are discriminated, and the corresponding cross sections are determined. The phase shift difference between the Coulomb and strong amplitudes is obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Faraday-effect polarimeter-interferometer system for current density measurement on EAST

A multichannel far-infrared laser-based POlarimeter-INTerferometer (POINT) system utilizing the three-wave technique is under development for current density and electron density profile measurements in the EAST tokamak. Novel molybdenum retro-reflectors are mounted in the inside wall for the double-pass optical arrangement. A Digital Phase Detector with 250 kHz bandwidth, which will provide real-time Faraday rotation angle and density phase shift output, have been developed for use on the POINT system. Initial calibration indicates the electron line-integrated density resolution is less than 5 × 10{sup 16} m{sup −2} (∼2°), and the Faraday rotation angle rms phase noise is <0.1°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗